PST-100. Instruction Manual English Version. Please read carefully before use

Similar documents
VarioDrive C, technical information. VarioDrive C, size 084. VarioDrive C, size 112. VarioDrive C, size 150

Двойной электромагнитный клапан DMV/12, DMV-D/12, DMV-DLE/12 DUNGS

501 series. Aluminium, E-coating treatment

Описание на системы датчиков воздушного зазора. Модель 4000

SHORT STROKE CYLINDERS Ø 8 to 100 mm - single and double acting with single/double rod, antirotation device

Servotronic Digital 615 Series

503 series. Level C to +50 C spool & sleeve metal-to-metal sealing. Aluminium, E-coating treatment

TOPAS PMW-basic Hot water meter

Электромагнитные клапаны для пара Burkert

сайт: почта:

Пневмоострова Burkert

Valve Manifolds. Series сайт: эл. почта:

Kolmeks. Инструкция по эксплуатации (eng)

2012 Series Solenoid Pilot Actuated Valves

Pressure transmitterses. По вопросам продаж и поддержки обращайтесь: Единый адрес для всех регионов:

FESTO. Документация. Линейные приводы DGC-K (eng) По вопросам продаж и поддержки обращайтесь:

Электромагнитные клапаны для агрессивных и чистых сред Burkert

Каталог продукции Buhler

Kolmeks. Инструкция по эксплуатации (eng)

Модульные клапаны Burkert

Каталог продукции DUNGS

DL1000 Electrode Mountings

HONDA. Инструкция по эксплуатации (eng.)

FESTO Документация Поворотные приводы DRRD

сайт: эл. почта:

Регулирующие клапаны с электроприводом Burkert

Hydraulic Flanges SAE J 518 С & ISO 6164

english Technology in the future SL800 Series

По вопросам продаж и поддержки обращайтесь:

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

MT4-024/MT4-230 MT8-024/MT8-230

Sartolab P The new way for reliable sterile filtration of cell culture media

Каталог продукции. Гидравлические борты и подъемники. Единый адрес для всех регионов:

FESTO. Документация. Стандартные распределители VSVA с индивидуальным подключением. По вопросам продаж и поддержки обращайтесь:

Combics Weighing Platforms CAAPP...

По вопросам продаж и поддержки обращайтесь:

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

Каталог продукции SULZER

80 Series V Digital Multimeter Safety Information

Switching DC Power Supply

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

3-Year Limited Warranty. See the Users Manual for the full warranty.

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

362 Clamp Meter. Users Manual

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Electronic Ignition Module

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Tina 11A Connection block

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Tina 10A/B/C Adaptor unit

Electronic Ignition Equipment

2-Year Limited Warranty. See the Users Manual for the full warranty.

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

i3000s/i2000 Flex AC Current Probe

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

OPERATION & MAINTENANCE INSTRUCTIONS

190M. Medical ScopeMeter. Safety Information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

OPERATION & MAINTENANCE INSTRUCTIONS

FMC-1/2 Tina Muting unit

Battery Power Inverters

c-go 24V/6A 24V/8A 24V/12A

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS

Rental Industry Safety Tester Safe Check 5s

28W WORK LAMP Model: CTL28 Part No:

EStrong-series Emergency Stop

Tina 4A Connection block

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

SLA Battery Capacity Analyzer

KD1E Range Potential Indicators

OPERATION & MAINTENANCE INSTRUCTIONS

Megohmmeter Test Probe

Operator s Handbook for Compact High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS

1000FLT. Users Manual. Fluorescent Light Tester

Go to to register your product and find more information.

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Users Manual. Phase Rotation Indicator

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

High Frequency SineWave Guardian TM

Operator s Handbook for. Compact. High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS. Can be used in accordance with: Australian Standard AS3894.


PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

3/2-Way Valve DN 15 up to DN 40. Technical Information. normal function, normally closed. distributing, mixing function and shut - off function

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Operator Instructions for Tension Links

Transcription:

PST-100 Instruction Manual English Version Please read carefully before use http://leister.nt-rt.ru

По вопросам продаж и поддержки обращайтесь: Архангельск (8182)63-90-72 Астана +7(7172)727-132 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249-28-31 Волгоград (844)278-03-48 Вологда (8172)26-41-59 Воронеж (473)204-51-73 Екатеринбург (343)384-55-89 Иваново (4932)77-34-06 Ижевск (3412)26-03-58 Казань (843)206-01-48 Калининград (4012)72-03-81 Калуга (4842)92-23-67 Кемерово (3842)65-04-62 Киров (8332)68-02-04 Краснодар (861)203-40-90 Красноярск (391)204-63-61 Курск (4712)77-13-04 Липецк (4742)52-20-81 Магнитогорск (3519)55-03-13 Москва (495)268-04-70 Мурманск (8152)59-64-93 Набережные Челны (8552)20-53-41 Нижний Новгород (831)429-08-12 Новокузнецк (3843)20-46-81 Новосибирск (383)227-86-73 Орел (4862)44-53-42 Оренбург (3532)37-68-04 Пенза (8412)22-31-16 Пермь (342)205-81-47 Ростов-на-Дону (863)308-18-15 Рязань (4912)46-61-64 Самара (846)206-03-16 Санкт-Петербург (812)309-46-40 Саратов (845)249-38-78 Смоленск (4812)29-41-54 Сочи (862)225-72-31 Ставрополь (8652)20-65-13 Тверь (4822)63-31-35 Томск (3822)98-41-53 Тула (4872)74-02-29 Тюмень (3452)66-21-18 Ульяновск (8422)24-23-59 Уфа (347)229-48-12 Челябинск (351)202-03-61 Череповец (8202)49-02-64 Ярославль (4852)69-52-93 сайт: www.leister.nt-rt.ru эл. почта: ets@nt-rt.ru

PST-100 Contents Page General Description 4 Technical Specification 5 Unpacking 6 Safety precautions and symbols 6 PST-100 Earth Terminal 8 Symbol definitions IEC61010:2010 8 Calculating the test voltage 9 SP-02-74 test voltage formula 10 Operation 11 Setting the Output Voltage 11 Applications 12 Insulation Testing 12 Gas Discharge Lamp Testing 12 Ozone Production 12 Electromagnetic compatibility 13 Electromagnetic Emissions European Union Directive 2004/108/EC 13 Maintenance 15 Disposal information 16 EC Declaration of conformity 17 Contact details 18 Distributor details 18 3

Instruction Manual General Description The PST-100 high voltage spark tester is a lightweight, hand held, sparktest pistol. The PST-100 is primarily used for detecting pinholes or flaws in electrically non-conductive coatings, linings, membranes, pipe wraps and other plastic coated metals. The PST-100 generates a pulsed ring output voltage. The pulse repetition is 20mS @ 50Hz or 16.6mS @ 60Hz mains. The ring frequency is approximately 100kHz. The output voltage is adjustable from 10kV to 55kV. 20ms 100kHz ring Output voltage characteristics at 50hz mains frequency 4

PST-100 Technical Specification Operating temperature range: Storage temperature range: Supply voltage: T50/T51 T52/T53 Supply frequency: Max power consumption: Output voltage: Output: Pistol weight: Altitude: Relative humidity: Installation category: 0 to +30 C -10 to +40 C 220/240V AC 105/120V AC 50 to 60 Hz 30VA 10kV to 55kV Pulsed Ring 1.0kg Up to 2000m 80% Max (Non-Condensing) Category II Note: PST-100 nose cones are user replaceable. The voltage variants are identifiable from the colour of the solid insert as shown. Nose cone colour coding Part No. T52N 110V (T52/T53) Part No. T8B 230V (T50/T51) This product has been manufactured under controls established by a quality management system that meets the requirements of ISO9001:2008 which has been independently certified by BVC under certificate number 3414 5

Instruction Manual Unpacking Remove the PST-100 from its packaging and check for damage. If any part is damaged, the carrier and supplier should be notified immediately. All packing material should be kept for inspection. The PST-100 should not be used. The package contains the following items: 1 x PST-100 pistol unit 1 x Flexible probe Safety precautions and symbols Caution, risk of danger Caution, risk of shock Category II double isolation Earth (ground) terminal Read the information in this manual carefully before using the equipment. Note: The works safety officer should approve the use of this equipment. 6

PST-100 The PST-100 Spark Tester is intended to generate a high voltage discharge, it is only to be used by responsible and authorised personnel that have read and understood this manual. The probe must NEVER be directed at the body. There is a potential risk to those who might have an incipient heart condition. There is also a potential risk from the reflex action when receiving a high voltage shock. Injury could also occur if the spark were discharged to sensitive parts of the body (e.g. eyes). In a reasonably ventilated room of a volume greater than 40m 3, the exposure to ozone produced by the high voltage spark should not present a risk to health. In a confined space situation it is likely that ozone levels will exceed the exposure limit and present some risk to health. Under these conditions adequate ventilation must be provided. WARNING: This equipment must not be used in any combustible atmosphere; the high voltage discharge will cause a spark from which an explosion could result. WARNING: This equipment must not be exposed to damp or wet conditions, or where the amount of conductive dust is greater than would occur in a normal situation. WARNING: Never connect or disconnect the flexible probe electrode with the generator connected to the mains supply. Misuse or failure to comply with the guidelines outlined in this manual may impair the safety provided by the equipment. 7

Instruction Manual PST-100 Earth Terminal The PST-100 has been tested and verified by an authorised, independent third party as meeting the requirements of IEC 61010:2010 - Safety requirements for electrical equipment for measurement, control, and laboratory use. The construction methods employed throughout comply with double insulation. The earth terminal located on the handle is a functional earth terminal, NOT a Protective Conductor Terminal as defined by IEC61010 and is intended as a high voltage return point during the operation of the PST-100. This arrangement also aids suppression of possible EMC interference. Therefore when conducting an electrical safety test (Portable Appliance Test) to the PST-100 it should be considered a class 2 appliance and tested accordingly. Symbol definitions IEC61010:2010 Functional Earth (ground) Terminal Terminal by which electrical connection is made directly to a point of a measuring or control circuit or to a screening part and which is intended to be earthed for any functional purpose other than safety. Double Insulation Insulation comprising both basic insulation and supplementary insulation. 8

PST-100 Below is a pictorial representation of the PST-100, detailing the functional earth terminal arrangement. Output adjustment pot L N L fuse Switch 1 N fuse Switch 2 Control electronics HT terminal + - - + Nose cone Y capacitors PST-100 functional earth terminal arrangement Calculating the test voltage The test voltage needs to be high enough to locate a fault but not so high as to cause one. With reference to BS EN 60052:2002, (measurement of voltage with Sphere-Gaps) it can be seen that 32,000 volts will jump a gap of 1cm between spheres of 5cm diameter, however the same voltage will jump a gap of nearly 3cm between needles. This is because the shape of the electrode affects the point at which corona discharge starts. A spark or arc over, will occur when the voltage is high enough such as to cause localised breakdown of the air between the electrodes, a spark then forms, ionising the air drastically reducing its electrical resistance. For materials with a thickness in the range of 1mm to 30mm, the NACE Standard SP-02-74 voltage calculation formula is normally used. 9

Instruction Manual SP-02-74 test voltage formula Test Voltage = 1250 x T coating Where T coating is the coating thickness in mils (0.001 ). Alternatively Test Voltage = 250 x T coating Where T coating is the coating thickness in microns (0.001mm). After the test voltage is calculated it is necessary to check that the voltage is not so high as to damage the material. The dielectric strength is the voltage at which the material starts to breakdown, this is expressed in volts per mm, normally with D.C. As an example, a 2mm thick sheet of P.V.C. would require a voltage of 11.18kV using the above formula. Referring to the manufacturer s technical data, the dielectric strength is 8.4kV per mm. Therefore, 2mm of such material has a dielectric strength of 16.8kV and is safe to test at 11.18kV. 10

PST-100 Operation WARNING: NEVER connect or disconnect the flexible probe electrode with the generator connected to the mains supply. WARNING: This equipment must not be used in any combustible atmosphere; the high voltage discharge will cause a spark from which an explosion could result. WARNING: This equipment must not be exposed to damp or wet conditions, or where the amount of conductive dust is greater than would occur in a normal situation. Screw the flexible probe electrode into the red end of the PST-100. Set the output control knob on the rear fully anti-clockwise. Connect the plug to the mains supply socket. Setting the Output Voltage Hold the end of the flexible probe at the determined distance for a spark to jump to an earthed metal test piece, squeeze the trigger and turn the output control knob slowly clockwise until the output voltage is high enough to cause a spark to jump the gap. Alternatively - for increased accuracy in setting the output voltage - a Buckleys Spark Gap Setter (part number A2) may be used. The probe should always be kept moving when testing as the high voltage and ring frequency combination may cause heating in the article under test which may result in burning. The output control should be adjusted for the lowest output at which an effective test can be carried out. When testing is complete, release the trigger to switch off the PST-100 s output. Disconnect the PST-100 from the mains supply before attempting to remove the flexible probe. 11

Instruction Manual Applications Insulation Testing The insulation to be tested must have a conductive backing, e.g. if a joint in plastic or rubber is to be tested, it should be laid on a met- al sheet. If this is not practical, aluminium foil or copper wire can be placed behind the joint. Ideally this should be earthed, although this is not necessary if the area of the metal backing is larger than the area of the probe by a ratio of at least 1000:1. Slowly sweep the area to be tested, looking at the probe at all times. When a fault is passed over, the high voltage corona discharge will change to a single spark. Remove the probe from the surface and mark the point where the fault was detected. NOTE: The electrode size has an effect on the output voltage. For this reason we recommend a maximum size of 150mm. Gas Discharge Lamp Testing The PST-100 can be used to excite gas discharge lamps to confirm that the vacuum has not been lost. The lamp/tube should not be fitted, as the high voltage could make contact with the fitting and be passed into the wiring, which may damage other equipment connected to that wiring. Hold the probe against the glass of the lamp and increase the output voltage from minimum, if the lamps vacuum is satisfactory, the lamp will glow where the probe touches the glass. Ozone Production Small quantities of ozone can be produced from the high voltage spark, useful for chemistry lectures, demonstrations etc. 12

PST-100 Electromagnetic compatibility Electromagnetic Emissions European Union Directive 2004/108/EC Before operating this equipment it is essential that the following risk assessment be taken. As this equipment will produce an electromagnetic emission when actually arcing down through a fault to earth, a risk assessment of the area in which the unit will be used should be carried out. For example, the equipment should not be operated where the electromagnetic disturbance generated may hinder the operation of such apparatus as: Domestic radios and television receivers Industrial manufacturing equipment Mobile radio equipment. Mobile radio and commercial radio telephone equipment Medical and scientific apparatus Information technology equipment Domestic appliances and household electronic equipment Aeronautical and marine radio apparatus Educational electronic equipment Telecommunications networks/apparatus Radio & television broadcast transmitters Lights and fluorescent lamps. The Directive also requires the above types of equipment to have an adequate level of electromagnetic immunity from such emissions. However, it should be borne in mind when doing an assessment that the directive applies to equipment supplied or taken into service after 1st January 1996 and that the equipment you are assessing, although legal, because of age, may not have this immunity. Common areas of risk are computers, critical safety equipment (fail/safe electronics), supply cables, control cables, signalling and telephone cables above, below and adjacent to the area where the 13

Instruction Manual tests are being carried out. The wearers of pacemakers and hearing aids should also be considered. Measuring and calibration equipment may also be susceptible. To make a comparison: an arc welder when in use, would create interference far greater than this type of tester. It would, therefore, be reasonable to assume that if an arc welder had been used in the area without problems, then an AC Pinhole Detector would be safe. However, it would be unwise to use both of these equipments on the same site at the same time as they may interfere with each other. The test area itself should also be considered. For example, the layout of the area would affect the distances, which the emissions would travel. Buildings and metal structures would shield against, or reduce, emissions. If the tester was being used inside a metal tank, for example, the tank would act as a very good shield. This would not, however, have the same effect if you were testing a plastic tank. If you were testing the circumference of a metal pipe then the pipe would act as an aerial and transmit the emissions further than expected. Remember that electromagnetic emissions travel in all directions and can even be bent or deflected. Neighbouring works or sites should also be taken into account as there may be equipment in use that could be affected by your tester s emissions. This type of tester will usually be used on outdoor sites and remote from susceptible equipment, but the SITE SAFETY OFFICER should always be consulted before any testing is carried out. This is particularly necessary where electronically controlled equipment is being used. Timing of the testing should also be considered as a means to avoiding interference problems. Consider testing when all susceptible equipment in the test area is switched off. If your tester is only used in one area, then simple tests will ascertain where the tester interferes with other equipment and these can be resolved by scheduling the proper testing accordingly. Again, you should remember neighbouring works. 14

PST-100 The PST-100 has been designed with EMC in mind and therefore all leads are of optimum length. If longer leads are used then they could transmit similar to aerials and cause interference. Always ensure that the tester and test piece is securely earthed because this will reduce any interference generated by the spark. This also prevents static build-up in the operator and thereby avoiding electric shock. Wherever you are intending to use equipment of this type, on your site or on a customers, always obtain clearance from the company safety officer. Maintenance The PST-100 has been designed to be maintenance free, however the PST-100 should be inspected regularly, checking for damage to the unit. If any damage is found, the PST-100 must not be used, and should be returned to the manufacturer for repair. Two operator replaceable fuses are located on the rear panel. Rating: 500mA anti-surge. Before carrying out maintenance ensure the PST 100 has been disconnected from the AC mains supply. To replace the PST 100 nose cone, first remove the small M4 x 6.0mm retaining grub screw from the nose cone locking ring, unscrew the nose cone locking ring and remove the nose cone from the PST 100 by gently pulling on the nose cone to separate it from the PST 100 main body. Fit the replacement nose cone in the reverse order to that described above ensuring that both the nose cone locking ring and retaining grub screw are tightened sufficiently to prevent the nose cone form coming loose. 15

Instruction Manual Locking Ring Nose Cone PST-100 Main Body Retaining Grub Screw Disposal information Producer registration number: WEE/HJ0051TQ This product must be disposed of in accordance with UK WEEE regulations. For further information on UK WEEE regulations click on: www.gov.uk/government/publications/weee-regulations-2013-government- guidance-notes 16

По вопросам продаж и поддержки обращайтесь: Архангельск (8182)63-90-72 Астана +7(7172)727-132 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249-28-31 Волгоград (844)278-03-48 Вологда (8172)26-41-59 Воронеж (473)204-51-73 Екатеринбург (343)384-55-89 Иваново (4932)77-34-06 Ижевск (3412)26-03-58 Казань (843)206-01-48 Калининград (4012)72-03-81 Калуга (4842)92-23-67 Кемерово (3842)65-04-62 Киров (8332)68-02-04 Краснодар (861)203-40-90 Красноярск (391)204-63-61 Курск (4712)77-13-04 Липецк (4742)52-20-81 Магнитогорск (3519)55-03-13 Москва (495)268-04-70 Мурманск (8152)59-64-93 Набережные Челны (8552)20-53-41 Нижний Новгород (831)429-08-12 Новокузнецк (3843)20-46-81 Новосибирск (383)227-86-73 Орел (4862)44-53-42 Оренбург (3532)37-68-04 Пенза (8412)22-31-16 Пермь (342)205-81-47 Ростов-на-Дону (863)308-18-15 Рязань (4912)46-61-64 Самара (846)206-03-16 Санкт-Петербург (812)309-46-40 Саратов (845)249-38-78 Смоленск (4812)29-41-54 Сочи (862)225-72-31 Ставрополь (8652)20-65-13 Тверь (4822)63-31-35 Томск (3822)98-41-53 Тула (4872)74-02-29 Тюмень (3452)66-21-18 Ульяновск (8422)24-23-59 Уфа (347)229-48-12 Челябинск (351)202-03-61 Череповец (8202)49-02-64 Ярославль (4852)69-52-93 сайт: www.leister.nt-rt.ru эл. почта: ets@nt-rt.ru