BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

Similar documents
MDC Series

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

MDCSL V, 30A

BSC Series

MDC Series

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

MDC Series

MDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

BLY34MDA Series. 50V, 30A Brushless Controller / Motor. User s Guide E Landon Drive, Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

BLWS23MDAxS-160 Offline Series 110VAC, 3A Brushless Controller / Motor

MDC Series

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide E. Landon Drive Anaheim, CA

MDC Series

MBDC V, 30A Brush Controller. User s Guide E. Landon Drive Anaheim, CA

BLY17MDA Series. 24V, 10A Brushless Controller/Motor. User s Guide E. Landon Drive Anaheim, CA

MBDC Series

MBDC V, 10A Brush Controller. User s Guide East Landon Drive, Anaheim, CA

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

BLY17MDA-2W Series. 24V, 10A Brushless Controller/Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

DPS32001 and DPS32PS1

MBC01081 Series. Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

USER'S MANUAL MODEL DPS32PG1 DRIVER PACK

MBL600 Bilevel Step Motor Driver

MLA Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

USER'S MANUAL MODEL DPD60001 MICROSTEP DRIVER PACK

MBC15081 Bipolar Microstep Driver

ACP-MxI Series AC Induction Motor

ACP-MxI Series, AC Induction Gear Motor

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

Filtered PWM Speed Control for Permanent Magnet DC Motors

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

730 CONTROL SERIES. Instruction Manual CONTROLS. Low Voltage DC Brushless Control. Phone (317) Fax (317)

Model A Switching Logic Board. User s Manual. For Use With Minarik Full-Wave Regenerative Drives

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

17429X.00 SERIES MODELS:

700B CONTROL SERIES. Instruction Manual Low Voltage DC Brushless Control CONTROLS. Phone (317) Fax (317)

Operations Manual. Zero Speed Switch Sensor Model ZS09P

User's Manual O

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

LNII Series Motor and Drives

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

SB SWITCH CONTROL BOX

DMX-A2-DRV Integrated Advanced Step Motor Driver

SAFTRONICS DF8 PLUS SERIES

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL

Boston Gear Ratiotrol DC Motor Speed Control

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

Installation & Operation Manual

RHINO MOTION CONTROLS

Panel Mount Digital Tachometer Model

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Adjustable Torque Controls

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

AxCent Servo Drive AB30A200

DR8010 tm. Hardware Reference Manual. Document Revision B4 May 15, 2018

LN3 Series Motor and Drives

Pick and Hold Module Pin Assignment and Description

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

ESC2301. Universal Electronic Governor Controller Operation Manual

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Boston Gear Ratiotrol

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

Type ABL-3906C Low-Voltage Brushless DC Motor Controls (IP-00)

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

Features IN THIS CHAPTER

SMD10 SMD11 SMD15 SMD30

DM320C. User s Manual. Fully Digital Stepping Driver. For. Version All Rights Reserved

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

CD-20A Sample Probe Controller User Manual

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

WHY5690 GENERAL DESCRIPTION: WHY5690 EVALUATION BOARD for WHY5640 Temperature Controller

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

Generator Start Control Module

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Generator Start Control Module

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

RECHARGE STATION OPERATION MANUAL. Version

Overvoltage Suppression F7 Drive Software Technical Manual

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 COMPUTER INPUT BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-225

Transcription:

BLDPN30001 Series 30A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com L010584 1

BLDPN30001 Driver Features Maximum Current Limit Setting from 10.0-30.0 Amps (peak) Internal or External Potentiometer Speed Control 0V to 5V External Voltage Speed Control 2-Quadrant Operation Hall Sensor Feedback Constant Velocity Mode Short Circuit Protection Requires 90-265VAC input power Speed Out Fault Out Run/Stop, Freewheel and Direction Selectable Ramp Up TTL-CMOS Compatible Inputs Compact Size (7.5 x 6.9 x 5.2 ) Works great with 24VDC-36VDC brushless motors 48VDC Bus Detachable, Screw type Terminal Blocks General Description The BLDPN30001 driver is designed to drive DC Brushless Motors at currents of up to 30A (peak) and 50V. Using hall sensor feedback, a constant velocity mode can be selected. The driver is protected against over current (cycle-by-cycle or latched), hall sensor error and under voltage. When an error occurs, a fault light and a fault output are turned on to notify the user. Include on the driver is an internal potentiometer to control the maximum phase current allowed into the motor and an internal potentiometer to control the speed of the motor. An external voltage (0-5VDC) can be used to control the speed as well. The direction of the motor can be preset by the direction control input. Other inputs to the drive include a run/stop and a motor freewheel input. When using the run/stop input, there are three ramp up profiles from standstill to select from. The run/stop input overrides all other inputs into the driver. Fault Protection Over current protection can be provided by means of a cover current latch function by setting the FLT LATCH dip switch on. If a motor current level exceeding the current limit set by the internal or external current limit potentiometer is produced, an over current latch is activated, shutting off the output. When a fault is detected, the driver turns off the motor current, the red FAULT LED alerts the user a fault occurred and the Fault Output (TB3 - Pin 5) goes low. The Fault Output is disabled, logic 1 output, when the FLT LATCH dip switch is in the off position and disabled. This Fault protection alerts the user of the following conditions. 1. Invalid Sensor Input Code 2. Over Current. The driver is equipped with cycle-by-cycle current limiting or over current latch. 3. Undervoltage Lockout activation at 9.1VDC for the input voltage and 4.5VDC for Hall Sensor voltage. Power Supply No power supply is needed as an internal transformer is used. The supplied line cord is all that is needed to power up the unit. The voltage range of the unit is 90VAC to 265VAC. L010584 2

Specifications Control Inputs: (TB1, Pins 1-3) TTL-CMOS Compatible Logic 0 = 0-0.8VDC Logic 1 = OPEN All three inputs (run/stop, freewheel, and direction) are pulled up through 20k Ohm resistors. Direction Control: (TB3, Pin 2) Logic 1 (open) - Clockwise Logic 0 - Counterclockwise Freewheel: (TB3, Pin 3) Logic 1 (open) - Motor is Enabled Logic 0 - Motor is de-energized and will coast Run/Stop: (TB3, Pin 4) Logic 1 (open) - Motor will not run and if running will come to a hard stop Logic 0 - Motor will run and will accelerate according to ramp dip switch setting Vcontrol: (TB1, Pin 4) To control the speed of the motor with an external DC voltage, INT/EXT SPD switch (SW1-POS1) must be switched to the ON position. 0VDC (min) - 5VDC (max) Control Outputs: (TB3, Pin 1 and 5) TTL-CMOS Compatible These outputs are able to sink 50mA Speed Output: (TB3, Pin 1) A 5V signal pulse out is available at a rate of 4 pulses for 1 revolution of an 8-pole motor, 3 pulses for 1 revolution of a 6-pole motor, and 2 pulses for 1 revolution of a 4-pole motor. 8-pole motor RPM = 15 * PG OUT (in Hz) 6-pole motor RPM = 20 * PG OUT (in Hz) 4-pole motor RPM = 30 * PG OUT (in Hz) Fault Output: (TB3, Pin 5) Logic 1 (5V out) - Status good, normal operation. Logic 0 - One of the three fault conditions listed in the Fault Protection section has occurred. When a fault is detected, the Fault Output (pin 5) goes low. Output Current Rating: Adjustable 10.0-30.0 amperes per phase maximum operating peak current (5.0-15.0 amperes per phase maximum operating continuous current) Power Requirements: (TB2, Pins 4 and 5) 90VAC (min) - 265VAC (max). The unit is protected with two 5mmx20mm 5A fuses. Please review the casing for wiring options. Operating Temperature: Heat Sink: 0-70 C L010584 3

Hall Sensor Power Output: 6.25V @ 30mA maximum. Typical current draw from hall sensor is 20mA. All three Hall Sensor inputs are pulled up through 20K ohm resistors. The external speed control potentiometer must be 10K Ohms. Open Loop/Closed Loop (Constant Velocity Mode) The driver can either be set for Open Loop or Closed Loop operation. Open Loop operation is used for applications where the speed of the motor needs to change according to the load. Closed Loop operation is used for applications where speed regulation is needed. Under closed loop operation, the speed is regulated despite changes to the load and the power supply voltage. To operate Open Loop, the O/C LOOP switch (SW2, pin 1) must be in the on position. To operate Closed Loop, the O/C LOOP switch (SW2, pin 1) must be in the off position and hte CLADJ POT (R3) and CLADJ dip switches (SW2, pin 2-4) must be set to optimize the driver for each application. If using an Anaheim Automation DC Brushless motor, the tables shown on the next page are the Close Loop potentiometer and dip switch settings for each motor. The regulated speed of the motor is then controlled by adjusting the internal or external speed pot. The motor speed can be monitored by measuring the pulse rate of PG OUT (TB3 - pin 1). If using a non-anaheim Automation DC Motor. 1. Start with setting the closed loop switches CL1, CL2, and CL3 on the on position. 2. Set CLADJPOT to 0%. 3. Adjust the internal speed pot or external speed pot to 100% The motor at this time should be running at its maximum speed. 4. Increase the closed loop gain by switching CL1, CL2, and CL3 incrementally one stage until the motor speed dips below the maximum speed. Set the switches up one stage to the position before the motor dips below the maximum speed and proceed to step 5. CL1 CL2 CL3 CL Gain On On On Min Off On On On Off On Off Off On On On Off Off On Off On Off Off Off Off Off Max 5. Slowly rotate CLADJPOT toward 100% until the motor speed slightly begins to decrease. At this point, the motor closed loop adjustments are set. * If a slower top motor speed is desired, set CLADJPOT to 0%. Increase the closed loop gain incrementally by setting CL1, CL2, CL3 with respect to the desired top motor speed and re-tune CLADJPOT, as described in step 4 and step 5. L010584 4

Anaheim Automation Motor Closed Loop Settings 4-Pole Motors Motor CL1 CL2 CL3 CL POT L010584 5 MAX SPD (RPM) MIN SPD (RPM) BLWR110S-15V-8000 On On On 80% 8000 500 BLWR111S-24V-10000 On On On 50% 10050 825 BLWR112S-24V-3700 On Off On 100% 3735 450 BLWR231D-36V-4000 On Off On 65% 4010 550 BLWR232D-36V-4000 On Off On 65% 4010 550 BLWR233D-36V-4000 On Off On 65% 4010 550 BLWR234D-36V-4000 On Off On 65% 4010 550 BLWR235D-36V-4000 On Off On 65% 4010 550 BLWR232S-24V-1350 Off Off Off 0% 1600 200 BLWS231D-36V-4000 BLWS231S-36V-4000 BLWS232D-36V-4000 BLWS232S-36V-4000 On Off On 65% 4010 550 On Off On 65% 4010 550 BLWS233S-36V-4000 On Off On 65% 4010 550 BLWS234D-36V-4000 BLWS234S-36V-4000 On Off On 65% 4010 550 BLWS235-36V-4000 On Off On 65% 4010 550 8-Pole Motors Motor CL1 CL2 CL3 CL POT MAX SPD (RPM) MIN SPD (RPM) BLY171S-17V-8000 On On On 0% 7500 500 BLY172S-17V-9500 On On On 0% 9000 500 BLY171S-24V-4000 On On On 80% 4000 250 BLY172D-24V-4000 BLY172S-24V-4000 On On On 80% 4000 250 BLY173D-24V-4000 On On On 80% 4000 250 BLY174D-24V-4000 BLY174S-24V-4000 BLY341D-48V-3200 BLY341S-48V-3200 On On On 80% 4000 250 Off On On 40% 3200 250 BLY342D-24V-3000 Off On On 40% 3000 250 BLY342D-30V-3000 BLY342D-30V-3000 BLY342D-48V-3200 BLY342S-48V-3200 BLY343D-48V-3200 BLY343S-48V-3200 Off On On 40% 3000 250 Off On On 30% 3200 250 Off On On 30% 3200 250 BLY343S-30V-3000 Off On On 40% 3000 250 BLY344D-48V-3200 BLY344S-48V-3200 Off On On 30% 3200 250 BLZ362S-36V-3500 Off On On 10% 3500 330 BLZ362S-160V-3500 Off On On 10% 3500 330 BLZ482S-160V-3500 Off On On 10% 3500 330 BLZ242S-24V-3500 Off On On 10% 3500 330

Commutation Sequence Step Step 1 2 3 4 5 6 1 2 3 4 5 6 Phase A + Z - - Z + Phase A - Z + + Z - Phase B Z + + Z - - Phase B Z - - Z + + Phase C - - Z + + Z Phase C + + Z - - Z Hall A 1 1 0 0 0 1 Hall A 1 1 0 0 0 1 Hall B 0 1 1 1 0 0 Hall B 0 1 1 1 0 0 Hall C 0 0 0 1 1 1 Hall C 0 0 0 1 1 1 120 Hall Spacing Sequence Forward 120 Hall Spacing Sequence Reverse Step Step 1 2 3 4 5 6 1 2 3 4 5 6 Phase A + Z - - Z + Phase A - Z + + Z - Phase B Z + + Z - - Phase B Z - - Z + + Phase C - - Z + + Z Phase C + + Z - - Z Hall A 1 1 1 0 0 0 Hall A 1 1 1 0 0 0 Hall B 0 1 1 1 0 0 Hall B 0 1 1 1 0 0 Hall C 0 0 1 1 1 0 Hall C 0 0 1 1 1 0 60 Hall Spacing Sequence Forward 60 Hall Spacing Sequence Reverse + = Top Transistor ON, Bottom Transistor OFF, Current Flows into this wire - = Top Transistor OFF, Bottom Transistor ON, Current Flows out of this wire Z = Top Transistor OFF, Bottom Transistor OFF, No current into or out of this wire (High Impedance) Motor Connection Refer to the hookup diagram for typical driver applications. When connecting a motor for the first time, connect the hall sensor wires (5 of them) to the driver. DO NOT CONNECT THE PHASES YET. Turn on power and rotate the motor by hand. If the RED FAULT LED comes on, the hall phases are incorrectly wired. If the RED FAULT LED does not come on then the hall wires are connected correctly. Power the unit down and proceed to connect the motor phases. If the motor does not run or runs erratically, power down and check the speed potentiometer and make sure the phases are connected correctly. There are six different ways to connect the phase wires, and normally only two will allow the motor to rotate, but only one is correct. If the direction of the motor is changed and the no-load current of the motor is approximately the same and the motor runs smoothly in both directions then the phase wires are correct. The wiring of the motor phases should be separated from the hall and input connections to not allow a possible source of interference. L010584 6

Terminal and Dip Switch Descriptions Pin # Description 1 Hall Sensor Power 2 Hall Sensor A 3 Hall Sensor B 4 Hall Sensor C 5 Hall Sensor Ground TB1: Motor Hall Terminals Pin # Description 1 Phase A 2 Phase B 3 Phase C TB2: Motor Phase Terminals Pin # Description 1 PG OUT 2 Direction 3 Freewheel 4 Run/Stop 5 Fault Out 6 VControl 7 GND TB3: Control Inputs and Outputs SW # Description 1 INT/EXT SPEED 2 FLT LATCH 3 RAMP 1 4 RAMP 2 5 60/120 SW1: Dip Switch SW # Description 1 O/C LOOP 2 CL1 3 CL2 4 CL3 SW2: Dip Switch Dip Switch Settings Function SW1 SW2 SW3 SW4 SW5 Internal Speed Control (R46) Off --- --- --- --- External Speed Control (TB3 - Pin 6) On --- --- --- --- Over Current Latching --- On --- --- --- Over Current Cycle-by-Cycle --- Off --- --- --- Ramp Profile 1 (4 Sec) --- --- Off Off --- Ramp Profile 2 (2 Sec) --- --- Off On --- Ramp Profile 3 (1 Sec) --- --- On Off --- Ramp Profile 4 (500mSec) --- --- On On --- 60 Hall Sensor Spacing --- --- --- --- Off 120 Hall Sensor Spacing --- --- --- --- On Standard Product (Ready to Ship) Off Off Off Off On SW1: Speed Adjustment, Over Current, and Ramp settings Fault Output The Fault Output is only active when the Fault Latch is enabled, setting the FLT LATCH dip switch on. The TTL level Fault Output indicates an over current or failure in the motor/driver operation. The Fault Output is normally at a TTL logic level 1. If a fault occurs, the Fault Output will go to a TTL logic level 0. L010584 7

Dip Switch Settings (cont.) Function SW1 SW2 SW3 SW4 SW5 Constant Speed Mode (Closed Loop) Off --- --- --- --- Voltage Controlled Speed Mode (Open Loop) On --- --- --- --- Closed Loop Compensation 1 --- --- --- --- --- Closed Loop Compensation 2 --- --- --- --- --- Closed Loop Compensation 3 --- --- --- --- --- Standard Product (Ready to Ship) On Off Off Off Off SW2: Open Loop and Closed Loop. If Closed Loop selected, Closed Loop compensation switches must be set according to motor speed desired. Motor Freewheel The motor freewheel feature allows the de-energizing of the motor phases. A high (open) input at this input causes the motor to run at the given speed, while a low at this input causes the motor to coast to a stop. Motor Run/Stop The motor run/stop feature allows the stopping of a motor by shorting out the bottom drives of the three phases. A low at this input allows the motor to run, while a high (open) input does not allow motor operation and if operating causes rapid deceleration. Motor Direction The motor direction feature allows the changing of the rotation of the motor. This input should not be changed while motion is in progress. A high (open) input causes the motor to turn in the CW direction, while a low at this input causes the motor to turn in the CCW direction. Speed Adjust Setting There are three ways to set the speed on this drive. One is to use the on-board or external potentiometer. To others is to use an external voltage. To use the on-board potentiometer, set INT/EXT SPD switch to the off position (default). To use the external 10K potentiometer or external 0V to 5V voltage speed setting, set INT/EXT SPD switch to the on position. If a voltage is used to control the speed of the motor, the 0V to 5V voltage can be tied on Vcontrol (TB3 - pin 6) with respect to GND (TB3 - pin 7). If an external potentiometer is used to control the speed of the motor, connect the pot wiper to Vcontrol (TB3 - pin 6), the positive end of the potentiometer to Hall Power (TB1 - pin 1) and the negative end to GND (TB3 - pin 7). The maximum voltage that can be placed on Vcontrol is 15V. A voltage exceeding 15V may cause damage to the driver. If a voltage other than 0V to 5V is needed to control the speed of the motor, contact Anaheim Automation for custom tuning of the Vcontrol input. L010584 8

Speed Output The PG OUT terminal (TB3 - pin 1) is used to determine the speed of the motor shaft. A 5V signal pulse out is shown at a rate of 4 pulses for 1 revolution of an 8-pole motor, 3 pulses for 1 revolution of a 6-pole motor, and 2 pulses for 1 revolution of a 4-pole motor. # Poles RPM 8 15 * PG OUT (in Hz) 6 20 * PG OUT (in Hz) 4 30 * PG OUT (in Hz) Heating Considerations The chassis fan shouldn t be blocked in any form as this will cause the unit to overheat. The fan should be placed at least 2 inches away from any surface when being mounted. Also the ventilation holes should have proper clearance from any surface to ensure proper unit ventilation. Typical Wiring Diagram L010584 9

Dimensions L010584 10

COPYRIGHT Copyright 2012 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Anaheim Automation, 4985 E Landon Drive, Anaheim, CA 92807. DISCLAIMER Though every effort has been made to supply complete and accurate information in this manual, the contents are subject to change without notice or obligation to inform the buyer. In no event will Anaheim Automation be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation. Anaheim Automation s general policy does not recommend the use of its products in life support applications wherein a failure or malfunction of the product may directly threaten life or injury. Per Anaheim Automation s Terms and Conditions, the user of Anaheim Automation products in life support applications assumes all risks of such use and indemnifies Anaheim Automation against all damages. LIMITED WARRANTY All Anaheim Automation products are warranted against defects in workmanship, materials and construction, when used under Normal Operating Conditions and when used in accordance with specifications. This warranty shall be in effect for a period of twelve months from the date of purchase or eighteen months from the date of manufacture, whichever comes first. Warranty provisions may be voided if products are subjected to physical modifications, damage, abuse, or misuse. Anaheim Automation will repair or replace at its option, any product which has been found to be defective and is within the warranty period, provided that the item is shipped freight prepaid, with previous authorization (RMA#) to Anaheim Automation s plant in Anaheim, California. TECHNICAL SUPPORT If you should require technical support or if you have problems using any of the equipment covered by this manual, please read the manual completely to see if it will answer the questions you have. If you need assistance beyond what this manual can provide, contact your Local Distributor where you purchased the unit, or contact the factory direct. ANAHEIM AUTOMATION L010584 11