HS5D Miniature Interlock Switches

Similar documents
HS5D Miniature Interlock Switches

Head Removal Detection Function for Safer Performance

Door Interlock Switches

HS5E Miniature Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

HS1C Interlock Switches with Solenoid

HS6B Series Subminiature Interlock Switch

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

Door Interlock Switches

HS1E Series Full Size Solenoid Locking Switches

Standard Interlock Safety Switches

HS1E-K Interlock Switches with Solenoid (3-circuit)

HS5E Series Miniature Solenoid Locking Switches

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Interlock Switches. Safety. Selection Guide HS6B Subminiature HS5D Miniature HS2B Full Size...

HS1E Interlock Swithes with Solenoid

HS5E Miniature Interlock Switches with Solenoid

Door Interlock Switches

HS6E - L 4 4 B 01 - G

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

HS6E Subminiture Interlock Switches with Solenoid

Door Interlock Switches

HS5E Miniature Interlock Switches with Solenoid

HS6E Subminiature Interlock Switches with Solenoid. Double Installation. Part Number. Cable Length (+) ( ) A2 A1

Door Interlock Switches

HS1C-P Interlock Plug Unit with Door Lock

HS1E Series Full Size Interlock Switch with Locking Solenoid

SG-B1 SERIES / SG-A1 SERIES

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS6B HS6E. Angled connection. cable. Compact with three poles of contacts. (HS6B) Small interlock switch with five poles and solenoid.

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Standard Interlock Safety Switches

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

HS6B Subminiature Interlock Switches

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches

Section. Safety Products Selection Guide...B-2

Interlock Switches Interlock Plugs

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples

ø8 A8 Series Miniature Control Units

Safety Limit Switch

ø10 A1 Series Miniature Control Units

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

Enabling Switches Grip Style Enabling Switches

ø12 A2 Series Miniature Control Units

Hinged Safety Door Switch

UP Series Miniature Pilot Lights

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Think Automation and beyond... IDEC Safety Interlock Switches

Safety switches with separate actuator

Manual Reset Limit Switch

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

RU Series Universal Relays

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

2 Specifications and Ratings. Applicable Standards. Operating Condition. Thermal Current Ith 10A Contact Ratings. Operating Speed

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

LK Position Switches TECHNICAL DATASHEET.

HS7A-DMC Non-contact Interlock Switches

Safety-door Switch. Ordering Information

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

Position switches FD series

D4DL. Guard Lock Safety-door Switch. Model Number Structure

LR-LX-LK-LW Safety Switches with separate actuator

22mm XW E-Stops. UL File #E68961 CCC No Specifications

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Enabling Switches. Safety. Selection Guide

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Safety rope switches with reset for emergency stop

Position switches FC series

Switches & Pilot Devices

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Safety rope switch with reset for emergency stop

Safety switches with separate actuator

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

XA Series Emergency Stop Switches (w/removable Contact Block)

Safety Control HR1S-AC. Safety Relay HR1S-AC

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

FL series position switches

XW Series Emergency Stop Switches

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

D4BS CSM_D4BS_DS_E_8_4

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

PRODUCT SPECIFICATION. Stack Lights. Series.

Safety switches for hinged doors

Microswitches MK series

Safety switches with solenoid and separate actuator

D4NH CSM_D4NH_DS_E_7_1

Transcription:

Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B). 3 contact with dual enabling contacts and a monitor contact are available. Can be installed in narrow spaces. (W D H mm) The actuator is interchangeable with HS5B and HS5E. Double insulation structure eliminates the need for grounding. The head orientation can be rotated, allowing 8 different actuator entries. Degree of protection (contacts): IP67 (IEC6059) NC contacts with direct opening action (IEC/EN6097-5-) Proprietary actuators prevent invalidation of the contacts (ISO9, EN088). M3 terminal screws for easy wiring. Gold-plated contacts suitable for small loads. Flush Silhouette Switches & Pilot Lights Lights LED Illumination Safety Products Blocks Comm. s Specifications ISO9 EN088 IEC6097-5- EN6097-5- (TÜV approval) GS-ET-5 (TÜV approval) Applicable Standards UL508 CSA C. No. GB08.5 (CCC approval) IEC60-/EN60- (applicable standards for use) Operating Temperature to +70 C (no freezing) Relative Humidity 5 to 85% (no condensation) Storage Temperature 0 to +80 C (no freezing) Pollution Degree 3 Impulse Withstand kv Voltage Contact Resistance 50 mω maximum (initial value) Insulation Resistance (500V DC megger) Between live and dead metal parts: 00 MΩ minimum Between terminals of different poles: 00 MΩ minimum Electric Shock Protection Class Class II (IEC60) Degree of Protection IP67 (IEC6059) Shock Resistance Damage limits: 000 m/s Vibration Resistance Operating Speed Direct Opening Travel Direct Opening Force Operating Frequency Mechanical Durability Electrical Durability Performance of s - of Removed Head Unit Conditional Short-circuit Current Weight (approx.) Operating extremes: 0 to 55 Hz, amplitude 0.5 mm Damage limits: Hz, amplitude.5 mm 0.05 to.0 m/s 0 mm minimum 50N minimum 900 operations per hour,000,000 operations minimum (GS-ET-5) 00,000 operations minimum (AC- 50V, 6A),000,000 operations minimum (V AC/DC,00 ma) (operation frequency: 900 operations per hour) Mechanical damage limits: 0 operations min. Insulation resistance: 00 MΩ (initial value) Dielectric strength: 000V, minute (initial value) 00A (50V) (note) head: 80g Metal head: 0g Note: Use a 50V/0A fast-blow fuse as a short-circuit protector. Contact Ratings Rated Insulation Voltage (Ui) 0V Thermal Current (Ith) 0A Rated Voltage (Ue) V 5V 50V Rated Current (Ie) AC DC Resistive load (AC-) 0A 0A 6A Inductive Load (AC-5) 0A 5A 3A Resistive load (DC-) 8A.A.A Inductive Load (DC-3) A.A 0.6A Minimum applicable load (reference): 5V AC/DC, ma (Applicable range may vary with operating conditions and load types.) TÜV rating: AC-5 3A/50V, DC-3 A/V Part No. Development Circuit Code : NO-NC 0: NC : NO-NC 03: 3NC Head Material blank: Z : Metal Parts Description - Z RN M Right-angle (SUS) Angle Adjustable (for hinged doors) Straight w/rubber bushing (Use conduits or cable glands which can maintain IP67 protection.) blank: G/ P: PG3.5 M: M Head/Housing Color RN: Red/Gray M3 Screw Straight (SUS) Right-angle w/rubber bushing AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion Protection References 689

Miniature Safety Interlock Switch Package Quantity: NC-NO NC NC-NO 3NC Contact Confi guration 3 33 3 3 Size Part No. Metal Head G/ -RN -ZRN PG3.5 -RNP -ZRNP M -RNM -ZRNM G/ -0RN -0ZRN PG3.5-0RNP -0ZRNP M -0RNM -0ZRNM G/ -RN -ZRN PG3.5 -RNP -ZRNP M -RNM -ZRNM G/ -03RN -03ZRN PG3.5-03RNP -03ZRNP M -03RNM -03ZRNM Package Quantity: Name Part No. Straight HS9Z-A5 Straight w/rubber bushings HS9Z-A5A Right-angle HS9Z-A5 Right-angle w/rubber bushings HS9Z-A5A Angle Adjustable (vertical/horizontal) HS9Z-A55 Arrangement (3) () (33) 3 (3) Head Removal Detection Function All models are equipped with Head Removal Detection Function. When the head is removed, such as when the head is rotated, the main circuit (-) turns OFF. - (example) When the actuator is removed or inserted, the operation of the main circuits (-, -) are the same. However, when the head is removed, disparity is detected (-: OFF, -: ON). The disparity of the contacts detects the removal of the head. Head removal detection function Main circuit (-) is removed is inserted Head is removed - When actuator is removed When actuator is inserted When head is removed Main circuit (NC) OFF ON OFF Main circuit (NC) OFF ON ON Note: Head removal detection function is not a direct opening action mechanism. Disparity Existing Interlock Switches When actuator is removed When actuator is inserted When head is removed Main circuit (NC) 3 OFF ON ON Monitor circuit (NC) OFF ON ON 690

Dimensions and s - ZRN (Metal Head) With HS9Z-A5 Straight Slot Plug (supplied) Stop Metal Head Cover (silver) 6.. 6. 5. 6 ± With HS9Z-A5 Right-angle 9. 5 36 6. 5. 6. Metal Head Cover (silver) (RedI 8 Stop 6 ± to -M Screws : Reference mounting position 5 Flush Silhouette Switches & Pilot Lights Lights LED Illumination Safety Products Blocks Metal Head Cover (silver) 7.7.5 35.3 7.7 Metal Head Cover (silver) Comm. s Cover Stop Slot Plug (supplied) ± 9. 5 8 to -M Screws Cover Stop ± 5 All dimensions in mm. AS-Interface Relays & Timers Sockets Circuit Protectors - RN () With HS9Z-A5 Straight 6. 6.. 5. 36 5. 6. 6. Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion Protection 7.7.5 35.3 7.7 References Stop 6 ± 9. 5 8 to -M Screws Stop 6 ± 5 With HS9Z-A5 Right-angle Cover Stop Slot Plug (supplied) ± 9. 5 8 to -M Screws Cover Stop ± 5 Note: Plug the unused actuator insertion slot using the slot plug supplied with the safety interlock switch. All dimensions in mm. 6

Dimensions Straight (HS9Z-A5) Right-angle (HS9Z-A5) Straight w/rubber bushing (HS9Z-A5A) 6. 3. (6) 33 5. 0.8 7. 7. 7.3 3.8 5.3 0.8 -ø.3 Right-angle w/rubber bushing (HS9Z-A5A) (.) (39.7) 0.8. -R 6. 5 6 Stop.5 0.8 5 Stop -ø..6 0.8 () -ø0 5 Stop Washer (supplied with the actuator) 5 Washer (supplied Rubber Bushing with the actuator) (5) 0.8 A () -ø.3 9 0 (Straight, Right-angle) -M Screw Horizontal Swing 3 Orienting Insert Angle Adjustable (HS9Z-A55) º Cover Angle Adjustment (M3 Hexagon Socket Head Screw) Stop 3 6 38 (5) -ø9 Rubber Bushing 5.8 8.5 -ø9 -ø0 B Stop The mounting center distance is set to mm at factory. When - mm distance is required, adjust the distance by moving the rubber bushings. A B : The actuator has fl exibility to the directions indicated by the arrows. When -mm distance is selected, the actuator swings vertically. (Straight w/rubber bushing) (Right-angle w/rubber bushing) -M Screw 5 7 8.5 9 Vertical Swing Orienting Insert Stop 0.8 º 3.6 R. (M Holes) Angle Adjustment (M3 Hexagon Socket Head Screw) Interlock Switch Mounting centers can be widened to mm by moving the rubber cushions. Mounting Reference Position As shown in the fi gure below, the mounting reference position of the actuator when inserted in the interlock switch is where the actuator stop placed on the actuator lightly touches the interlock switch. Note: After mounting the actuator, remove the actuator stop from the actuator. Door Stop Interlock Switch Stop Interlock Switch Stop (horizontal/vertical swing) -M Screw 38 Note: The actuator stop is supplied with the actuator and used when adjusting the actuator position. Remove the actuator stop after the actuator position is determined. Contact Configuration and Operation Chart Stop HS9Z-A5 Model Contact Confi guration Contact Operation Chart (reference) - -0 - -03-3 3- - - - 33 3-33-3 - - 3-3 0 ( Mounting Reference Position) Approx. Approx..6 6.7 removed completely Door Stop Cover HS9Z-A5 HS9Z-A55 Orientation (Angle Adjustable) The angle of actuator swing can be changed using the orienting insert (white plastic) installed on the back of the actuator. Do not lose the orienting insert, otherwise the actuator will not operate properly. Approx. 6. (Travel: mm) : Contact ON (closed) : Contact OFF (open) inserted completely The operation characteristics shown in the chart above are for the HS9Z-A5. For other actuator types, add.3 mm. The operation characteristics show the contact status when the actuator enters the entry slot of an interlock switch. 69

Safety Precautions In order to avoid electric shock or fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the interlock switch. If relays are used in the circuit between the interlock switch and the load, use only safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the interlock switch. Perform risk assessment and make up a safety circuit which satisfi es the requirements of the safety category. For wiring, use wires of a proper size to meet the voltage and current requirements. Tighten the terminal screws to Instructions Regardless of door types, do not use the interlock switch as a door stop. Install a mechanical door stop at the end of the door to protect the interlock switch against excessive force. Do not apply excessive shock to the interlock switch when opening or closing the door. A shock to the interlock switch exceeding,000 m/s may cause damage to the interlock switch. Do not open the lid of the interlock switch. Loosening the screws may cause damage to the interlock switch. Prevent foreign objects such as dust and liquids from entering the interlock switch while connecting a conduit or wiring. Plug the unused actuator entry slot using the slot plug supplied with the interlock switch. Use proprietary actuators only. When other actuators are used, the interlock switch may be damaged. Safety function of the door interlock switch will be lost if a spare key is inserted into the interlock switch. Make sure that a spare key is not used on the interlock switch. Ensure that the actuator is fi rmly fastened to the door (by welding, rivet, or special screws) in the appropriate location, so that the actuator cannot be removed. Do not cut the actuator. Modifi cation of the actuator may cause damage. Mounting Examples Application on Sliding Doors Door HS9Z-A5 Interlock Switch Door Stop a recommended torque of 0.6 to 0.8 N m. Improper soldering or failure to tighten the terminal screw may cause overheating and fi re. Do not place a PLC in the circuit between the interlock switch and the load. Safety security can be endangered in the event of a malfunction of the PLC. Do not install the actuator in the location where a human body may come in contact. Otherwise injury may occur. Do not disassemble or modify the interlock switch, otherwise a malfunction or an accident may occur. Installing the Head Do not use the plastic and metal head of the HS5B interlock switches and metal head of the HS5E interlock switch on the. When using these and HS5E interlock switches adjacently, ensure that the heads are not interchanged. HS5E HS5B Metal Head Metal Head Metal Head Metal Metal (silver color) (black) (black or gray) of Hinged Door When using the interlock switch for a hinged door, refer to the minimum radius of doors shown below. For the doors with small minimum radius, use angle adjustable actuators (HS9Z-A55). Note: Because deviation or dislocation of hinged door may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A5 When the door hinge is on the extension line of the interlock switch surface: Minimum Radius 0 mm When the door hinge is on the extension line of the actuator mounting surface: Minimum Radius 90 mm Flush Silhouette Switches & Pilot Lights Lights LED Illumination Safety Products Blocks Comm. s AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion Protection References Application on Hinged Doors mm 60 mm HS9Z-A5 Door When using the HS9Z-A55 Angle Adjustable When the door hinge is on the extension line of the interlock switch surface: Horizontal Swing Vertical Swing HS9Z-SH5 Sliding Interlock Switch 50 mm 50 mm 693

When the door hinge is on the extension line of the actuator mounting surface: Horizontal Swing 70 mm Vertical Swing 50 mm Angle Adjustment for the HS9Z-A55 Using the angle adjustment screw, the actuator angle can be adjusted (see figures on page 69). Adjustable angle: 0 to The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the interlock switch. After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not loosen. Rotating the Head The head of the can be rotated by removing the four screws from the corners of the head and reinstalling the head in the desired orientation. When reinstalling the head, make sure that no foreign object enters the interlock switch. Tighten the screws tightly, because loose tightening may cause malfunction. Recommended screw tightening torque: 0.9 to. N m Factory Setting Alternative Head Orientations The above recommended tightening torques of the mounting screws are the values confi rmed with hex socket head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not come loose after mounting. Mounting bolts must be provided by the user. To avoid unauthorized or unintended removal of the interlock switch and the actuator, it is recommended that the interlock switch and the actuator be installed in an unremovable manner, for example using special screws or welding the screws. Applicable Crimping When using crimping terminals, be sure to install insulation tubes on the crimping terminals to prevent electric shocks. When using stranded wires, make sure that loose wires do not cause short circuit. Also do not solder the terminal to prevent loose wires. A.max.. to 5.8 ø3. Recommended manufacturer: JST Part No.: N0.5-3 Applicable wire size (with insulation tube): 0. to 0.5 mm Note: Do not remove screw A during wiring. Removing the screw may cause malfunction or damage. Applicable Wire Size 0.5 to.5 mm Applicable Cable Glands Use a cable gland with a degree of protection IP67. 6. max. G/, PG3.5, M max. 9 max. Head Removal Detection Function Only the NC contact of the main circuit (-) turns OFF (open) when the head is removed, such as when rotating the head. Because NC contacts of other than the main circuit (-) turn ON (closed), be sure to connect the main circuit (-) to the safety circuit. Recommended Tightening Torque Interlock Switch Mounting Screw:.8 ±. N m (two M screws) Housing Lid Screw: 0. to 0. N m (M3 screw) Screw: 0.6 to 0.8 N m (M3 screw) Connector:.7 to 3.3 N m s HS9Z-A5:.8 ±. N m (two M screws) HS9Z-A5: 0.8 ±. N m (two M Phillips screws) HS9Z-A5A/A5A:.0 to.5 N m (two M screws) HS9Z-A55:.0 to.5 N m (two M screws) When Using Flexible Conduits (Example) Flexible conduit example: VF-03 (made by Nihon Flex) Size Cable Gland Metal Cable Gland G/ RLC-03 (Nihon Flex) PG3.5 RBC-03PG3.5 (Nihon Flex) M RLC-03EC (Nihon Flex) When Using Multi-core Cables (Example) Size Cable Gland Metal Cable Gland G/ SCS-0 (Seiwa Electric) ALS-6 (Nihon Flex) PG3.5 ST3.5 (LAPP) ABS- PG3.5 (Nihon Flex) M ST-MX.5 (LAPP) ALS- EC (Nihon Flex) Different cable glands are used depending on the cable sheath diameter. When purchasing a cable gland, confirm that the cable gland is applicable to the cable sheath diameter. When using a /-NPT cable gland, use the interlock switch with M gland port (Part No.: - BM) together with an adaptor (Part No.: MA-M/NPT X.5 50-00, LAPP) and a gasket (Part No.: GP M, LAPP). Install a gasket between the interlock switch and the adaptor. Apply sealing tape between the cable gland and the adaptor to make sure of IP67 protection for the enclosure. 69