PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

Similar documents
PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 400 ekw 500 kva

PRIME 225 ekw 281 kva

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Caterpillar 2500 kw 3516C

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

DIESEL FEATURES GENERATOR SET

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Prime 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Mission STANDBY Critical Standby 2000 ekw 2500 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

CONTINUOUS 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

Mission Critical Standby 1800 ekw 2250 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Electronic unit injection

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Voltage 220 to or 1800 RPM

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

3412C Generator Set Electric Power. Specifications. Benefits and Features

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 350 ekw 438 kva 60 Hz 1800 rpm 480 Volts

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

STANDBY 440 ekw 550 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY 200 ekw 250 kva

Specifications. 3406C Generator Set Electric Power

Prime 455 ekw kva 60 Hz 1800 rpm 480 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Transcription:

DIESEL GENERATOR SET PRIME 1825 ekw 2281 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Image shown may not reflect actual package. FEATURES FUEL/EMISSIONS STRATEGY EPA Certified for Stationary Emergency Application (EPA Tier 2 emissions levels) DESIGN CRITERIA The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. UL 2200 / CSA - Optional UL 2200 listed packages CSA Certified Certain restrictions may apply. Consult with your Cat Dealer. FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries The Cat S O S SM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products CAT 3516C TA DIESEL ENGINE Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight CAT GENERATOR Matched to the performance and output characteristics of Cat engines Industry leading mechanical and electrical design Industry leading motor starting capabilities High Efficiency CAT EMCP 4 CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway SEISMIC CERTIFICATION Seismic Certification available Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength. IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 Pre-approved by OSHPD and carries an OSP-0084-10 for use in healthcare projects in California

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Single element canister type air cleaner Service indicator [ ] Dual element & heavy duty air cleaners [ ] Air inlet adapters & shut-off Cooling Radiator with guard [ ] Radiator duct flange Coolant drain line with valve Fan and belt guards Cat Extended Life Coolant Exhaust Dry exhaust manifold Flanged faced outlets [ ] Mufflers and Silencers [ ] Stainless steel exhaust flex fittings [ ] Elbows, flanges, expanders & Y adapters Fuel Generator Power Termination Secondary fuel filters Fuel priming pump Flexible fuel lines Fuel cooler* Cat digital voltage regulator (CDVR) with kvar/pf control, 3-phase sensing Winding temperature detectors Anti-condensation heaters Bus bar (NEMA or IEC mechanical lug holes)- right side standard Top and bottom cable entry [ ] Water separator [ ] Duplex fuel filter [ ] Oversize & premium generators [ ] Bearing temperature detectors Governor ADEM 3 [ ] Load share module [ ] Circuit breakers, UL listed, 3 pole with shunt trip,100% rated, manual or electrically operated [ ] Circuit breakers, IEC compliant, 3 or 4 pole with shunt trip, manual or electrically operated [ ] Bottom cable entry [ ] Power terminations can be located on the right, left and/or rear as an option. Control Panels EMCP 4.2 Genset controller [ ] Digital I/O Module [ ] Generator temperature monitoring & protection Lube Lubricating oil and filter Oil drain line with valves Fumes disposal Gear type lube oil pump [ ] Oil level regulator [ ] Deep sump oil pan [ ] Electric & air prelube pumps [ ] Manual prelube with sump pump [ ] Duplex oil filter Mounting Rails - engine / generator / radiator mounting Rubber anti-vibration mounts (shipped loose) [ ] Spring-type vibration isolator [ ] IBC Isolators Starting/Charging General 24 volt starting motor(s) Batteries with rack and cables Battery disconnect switch Right-hand service Paint - Caterpillar Yellow except rails and radiators are gloss black SAE standard rotation Flywheel and flywheel housing - SAE No. 00 [ ] Battery chargers [ ] Charging alternator [ ] Oversize batteries [ ] Ether starting aid [ ] Heavy duty starting motors [ ] Barring device (manual) [ ] Air starting motor with control & silencer [ ] Jacket water heater [ ] UL 2200 [ ] CSA certification [ ] CE Certificate of Conformance [ ] Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 Note Standard and optional equipment may vary for UL 2200 Listed Packages. UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. 2

SPECIFICATIONS CAT GENERATOR Cat Generator Frame size... 825 Excitation... Permanent Magnet Pitch... 0.6667 Number of poles...4 Number of bearings... Single bearing Number of Leads... 006 Insulation... UL 1446 Recognized Class H with tropicalization and antiabrasion - Consult your Caterpillar dealer for available voltages IP Rating... IP23 Alignment... Pilot Shaft Overspeed capability...150 Wave form Deviation (Line to Line)... 003.00 Voltage regulator... 3 Phase sensing with selectible volts/hz Voltage regulation...less than +/- 1/2% (steady state) Less than +/- 1/2% (w/3% speed change) CAT DIESEL ENGINE 3516C ATAAC, V-16, 4-Stroke Water-cooled Diesel Bore... 170.00 mm (6.69 in) Stroke... 190.00 mm (7.48 in) Displacement...69.00 L (4210.64 in 3 ) Compression Ratio... 14.7:1 Aspiration... TA Fuel System... Electronic unit injection Governor Type... ADEM3 CAT EMCP 4 SERIES CONTROLS EMCP 4 controls including: - Run / Auto / Stop Control - Speed and Voltage Adjust - Engine Cycle Crank - 24-volt DC operation - Environmental sealed front face - Text alarm/event descriptions Digital indication for: - RPM - DC volts - Operating hours - Oil pressure (psi, kpa or bar) - Coolant temperature - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - ekw, kva, kvar, kw-hr, %kw, PF Warning/shutdown with common LED indication of: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level Programmable protective relaying functions: - Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kw) (32) - Reverse reactive power (kvar) (32RV) - Overcurrent (50/51) Communications: - Six digital inputs (4.2 only) - Four relay outputs (Form A) - Two relay outputs (Form C) - Two digital outputs - Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Emergency stop pushbutton Compatible with the following: - Digital I/O module - Local Annunciator - Remote CAN annunciator - Remote serial annunciator 3

TECHNICAL DATA Open Generator Set - - 1800 rpm/60 Hz/480 Volts EPA Certified for Stationary Emergency Application (EPA Tier 2 emissions levels) DM8264 Generator Set Package Performance Genset Power rating @ 0.8 pf Genset Power rating with fan Fuel Consumption 100% load with fan 75% load with fan 50% load with fan Cooling System 1 Air flow restriction (system) Air flow (max @ rated speed for radiator arrangement) Engine Coolant capacity with radiator/exp. tank Engine coolant capacity Radiator coolant capacity 2281.25 kva 1825 ekw 480.9 L/hr 127.0 Gal/hr 378.8 L/hr 100.1 Gal/hr 269.9 L/hr 71.3 Gal/hr 0.12 kpa 0.48 in. water 2480 m³/min 87580 cfm 475.0 L 125.5 gal 233.0 L 61.6 gal 242.0 L 63.9 gal Inlet Air Combustion air inlet flow rate 180.0 m³/min 6356.6 cfm Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator 2 Motor starting capability @ 30% voltage dip Frame Temperature Rise 382.8 º C 721.0 º F 408.1 m³/min 14411.9 cfm 203.2 mm 8.0 in 6.7 kpa 26.9 in. water 715 kw 40662 Btu/min 1645 kw 93551 Btu/min 612 kw 34804 Btu/min 127 kw 7222 Btu/min 96.1 kw 5465.2 Btu/min 4647 skva 825 105 º C 189 º F Lube System Sump refill with filter 466.0 L 123.1 gal Emissions (Nominal) 3 NOx g/hp-hr CO g/hp-hr HC g/hp-hr PM g/hp-hr 5.01 g/hp-hr.27 g/hp-hr.14 g/hp-hr.027 g/hp-hr 1 For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. 2 Generator temperature rise is based on a 40 degree C ambient per NEMA MG1-32. UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. 3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77ºF, 28.42 in HG and number 2 diesel fuel with 35º API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. 4

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: AS1359, CSA, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, UL508A, 72/23/EEC, 98/37/EC, 2004/108/EC Prime - Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand is 100% of prime rated ekw with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year. Prime power in accordance with ISO3046. Prime ambients shown indicate ambient temperature at 100% load which results in a coolant top tank temperature just below the alarm temperature. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Cat representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Cat dealer. 5

DIMENSIONS Package Dimensions Length 6434.6 mm 253.33 in Width 2378.7 mm 93.65 in Height 2958.4 mm 116.47 in NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. (General Dimension Drawing #2846051). Performance No.: DM8264 Feature Code: 516DE7E Gen. Arr. Number: 2628106 Source: U.S. Sourced November 06 2012 20931889 6 www.cat-electricpower.com 2012 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.