HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Generating Rates. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by SCANIA

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

Generating Rates SERVICE PRP STANDBY. HR RANGE Soundproofed rental Powered by YANMAR

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Open Skid Powered by MITSUBISHI

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MITSUBISHI

Power kva Power kw Rated Speed r.p.m Standard Voltage V 400 Available Voltages V 400/230 V Rated at power factor Cos Phi 0,8

Manufacture facilities: SPAIN FRANCE INDIA CHINA USA Subsidiaries: ITALY PORTUGAL POLAND GERMANY I SINGAPORE UAE MEXICO PANAMÁ I ARGENTINA

Manufacture facilities: SPAIN FRANCE INDIA CHINA USA Subsidiaries: ITALY PORTUGAL POLAND GERMANY I SINGAPORE UAE MEXICO PANAMÁ I ARGENTINA

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

Model: HGK-310 T6 LPG INDUSTRIAL RANGE SoundProof Powered by WAUKESHA

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by SCANIA

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by VOLVO

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MTU

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by SCANIA

Generating Rates SERVICE PRP STANDBY. PROFESSIONAL RANGE Soundproof Powered by YANMAR

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

Generating Rates SERVICE PRP STANDBY. HR RANGE Soundproofed rental Powered by FPT_IVECO

Model: HHY 20 C T INDUSTRIAL RANGE Soundproof Powered by YANMAR

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Model: HFW-400 T5. Generating Rates

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

HRYW Yanmar. Industrial Rental Towable Generator. Model: HRYW 25 T6. Genset Ratings. Key features. Ratings Range - 60Hz Operation 1800 rpm Diesel

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

Key features. Genset Ratings. Ratings Range - 60Hz Operation. Standby kw kva Prime kw kva

Key features. Genset Ratings. Ratings Range - 60Hz Operation. Standby kw kva Prime kw kva Sound Attenuation: at 7m / 23 ft

125ºC RISE PRIME RATING kw kva Amps kw kva Amps SJ 55 M6 4045TF UCI 224 G 120/ VOLTAGE L-N L-L

1 / Genset general description

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

1 / Genset general description

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

1 / Genset general description

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

GE.VO.360/325.SS+0_all

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

DIESEL GENERATOR SET MTU 12V1600 DS660

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SET MTU 4R0113 DS80

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

DIESEL GENERATOR SET MTU 10V1600 DS500

Standby Amper VOLTAGE

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SET DG00660D5

GE.PK.022/020.SS+0_all

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GMR - 67P 67P 09/05/2016 GMR - 067P

Transcription:

20FT-HC WATER-COOLED THREE PHASE 50 HZ DIESEL Generating Rates SERVICE PRP STANDBY Power kva 1296 1420 Power kw 1037 1136 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 380/220-415/240 Rated at power factor Cos Phi 0,8 01 HIMOINSA Company with quality certification ISO 9001 HIMOINSA gensets are compliant with EC mark which includes the following directives: 2006/42/CE Machinery safety. 2014/30/UE Electromagnetic compatibility. 2014/35/UE electrical equipment designed for use within certain voltage limits 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by 2005/88/EC) 97/68/EC Emissions of gaseous and particulate pollutants. (amended by 2002/88/EC & 2004/26/EC) EN 12100, EN 13857, EN 60204 Ambient conditions of reference according to ISO 8528-1:2005 normative: 1000 mbar, 25ºC, 30% relative humidity. Prime Power (PRP): According to ISO 8528-1:2005, Prime power is the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output (Ppp) over 24 h of operation shall not exceed 70 % of the PRP. Emergency Standby Power (ESP): According to ISO 8528-1:2005, Emergency standby power is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP G2 class load acceptance in accordance with ISO 8528-5:2013 HIMOINSA HEADQUARTERS: Fábrica: Ctra. Murcia - San Javier, Km. 23,6 30730 SAN JAVIER (Murcia) Spain Tel.+34 968 19 11 28 Fax +34 968 19 12 17 Fax +34 968 19 04 20 info@himoinsa.com www.himoinsa.com Manufacture facilities: SPAIN FRANCE INDIA CHINA USA BRAZIL ARGENTINA Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

Engine Specifications 1.500 r.p.m. ENGINE PRP STANDBY Rated Output kw 1080 1190 Manufacturer Model Engine Type Injection Type Aspiration Type MITSUBISHI S12R PTA 4-stroke diesel Direct Turbocharged and after-cooled Number of cylinders and arrangement 12-V Bore and Stroke mm 170 x 180 Displacement L 49,03 Cooling System Water Lube Oil Specifications API CD or CF SAE 30 or SAE 40 Compression Ratio 14,0:1 Fuel Consumption Standby l/h 287,92 Fuel Consumption 100% PRP l/h 261,31 Fuel Consumption 75 % PRP l/h 201,75 Fuel Consumption 50 % PRP l/h 146,03 Fuel Consumption 25 % PRP l/h 89,67 Lube oil consumption with full load g/kwh 0,8 02 Total oil capacity including tubes, filters L 180 Total coolant capacity L 335 Governor Type Electrical Air Filter Type Dry Inner diameter exhaust pipe mm 304 Generator Generator Manufacturer MECC ALTE Poles No. 4 Connection type (standard) Star - Parallel Mounting type S-00 21" Insulation Class H class Enclosure (according IEC-34-5) Exciter system Voltage regulator Bracket type Coupling system Coating type IP23 Self-excited, brushless A.V.R. (Electronic) Single bearing Flexible disc Standard (Vacuum impregnation)

Application Data Exhaust System Maximum exhaust temperature ºC 520 Exhaust Gas Flow m 3/min 258 Maximum allowed back pressure mm H 2 O 600 Exhaust Flange Size (external diameter) mm 406,4 Heat dissipated by exhaust pipe KCal/Kwh 587,17 Necessary Amount Of Air Intake air flow m 3/h 5880 Cooling Air Flow m 3/s 30 Alternator fan air flow m 3/s 1,5 Starting System Starting power kw 7,5 x 2 Starting power CV 10,2 x 2 Recommended battery Ah 400 Auxiliary Voltage Vdc 24 Starter current peak A 1250 Nominal starter current A 400 03 Fuel System Fuel Oil Specifications Maximum power suction pump mm Hg 75 Diesel Maximum return feed pump mm Hg 150 Fuel Tank L 999

Dimensions Weight and Dimensions (L) (H) (W) Length mm 6.058 Height mm 2.896 Width mm 2.438 Maximum shipping volume m 3 42,77 (*) Weight with liquids in radiator and sump kg 12.863 04 Fuel tank capacity L 999 Autonomy Hours 5 Sound pressure level db(a)@7m 84 ± 2,4 (*) (with standard accessories) STANDARD VERSION Himoinsa has the right to modify any feature without prior notice. Weights and dimensions based on standard products. Illustrations may include optional equipment. Technical data described in this catalogue correspond to the available information at the moment of printing. Industrial design under patent. Local Distributor

CONTROL PANEL MODEL M5 Digital manual Auto-Start control panel and thermal magnetic protection (depending on current and voltage) and differential with CEM7. Digital control unit CEM7 AS5 Automatic panel WITHOUT transfer switch and WITHOUT mains control with CEM7 unit. (*) AS5 as optional with CEA7 unit. Automatic panel without transfer switch and WITH mains control. CC2 Himoinsa Switching cabinet WITH display. Digital control unit CEC7 AS5 + CC2 Automatic panel WITH transfer switch and with mains control. The display will be on the genset and on the cabinet. Digital control unit CEM7+CEC7 AC5 Automatic mains failure control panel. Wall-mounted cabinet WITH transfer switch and thermal magnetic protection (depending on current and voltage). Digital control unit CEA7 05

Controller features (I) : Standard x : Not included : Optional Generator Readings CEM 7 CEA 7 CEC 7 CEM7 + CEC7 Voltage between phases Voltage between neutral and phase Current intensities Frequency Apparent power (Kva) Active power (Kw) Reactive power (kvar) Power factor Mains Readings CEM 7 CEA 7 CEC 7 CEM7 + CEC7 Voltage between phases x Voltage between phases and neutral x Current intensities x Frequency x Apparent power x x x Active power x x x 06 Reactive power x x x Power factor x x x Engine Readings CEM 7 CEA 7 CEC 7 CEM7 + CEC7 Coolant temperature x Oil pressure x Fuel level (%) x Battery voltage x R.P.M. x Battery charge alternator voltage x Engine Protections CEM 7 CEA 7 CEC 7 CEM7 + CEC7 High water temperature x High water temperature by sensor x Low water temperature by sensor x Low oil pressure x Low oil pressure by sensor x Low water level x Unexpected shutdown x

Controller features (II) : Standard x : Not included : Optional Engine Protections CEM 7 CEA 7 CEC 7 CEM7 + CEC7 Fuel storage x Fuel storage by sensor x Stop failure x Battery voltage failure x Battery charge alternator failure x Overspeed x Underspeed x Start failure x Emergency stop Alternator Protections CEM 7 CEA 7 CEC 7 CEM7 + CEC7 High frequency Low frequency High voltage Low voltage Short-circuit x 07 Asymmetry between phases Incorrect phase sequence Inverse power x Overload x Genset signal drop Counters CEM 7 CEA 7 CEC 7 CEM7 + CEC7 Total hour counter Partial hour counter Kilowatt meter Starts valid counters Starts failure counters Maintenance Communications CEM 7 CEA 7 CEC 7 CEM7 + CEC7 RS232 RS485 Modbus IP Modbus

Controller features (III) : Standard x : Not included : Optional Communications CEM 7 CEA 7 CEC 7 CEM7 + CEC7 CCLAN x Software for PC Analogue modem GSM/GPRS modem Remote screen x Tele signal (8 + 4) (8 + 4) x (8 + 4) J1939 x Features CEM 7 CEA 7 CEC 7 CEM7 + CEC7 Alarm history (10) / (opc. +100) (10) / (opc. +100) (10) / (opc. +100) (10) / (opc. +100) External start Start inhibition Mains failure start x Start under normative EJP x Pre-heating engine control x Genset contactor activation 08 Mains & Genset contactor activation x Fuel transfer control x Engine temperature control x Manual override x Programmable alarms x Genset start function in test mode Programmable outputs x Multilingual Special Functions CEM 7 CEA 7 CEC 7 CEM7 + CEC7 GPS Positioning x Synchronisation x Mains synchronization x Second Zero elimination x RAM7 x Remote screen x Programming timer x

Generator set features Engine Standard air filter Standard fuel filter Standard oil filter Oil temperature sensor Coolant level sensor Exhaust gas compensator Diesel engine 4-stroke cycle Water-cooled 24V electrical system Radiator with blower fan Electronic governor HTW sender LOP sender Hot parts protection Moving parts protection Alternator H class insulation version Low level of noise emissions Door with window to visualize control panel, alarms and measurements Reinforced lifting points for crane hoisting and lower ones for transportation by forklift Residential steel silencer with -35dB attenuation and tilting cap in the exhaust Fuel tank integrated in the chassis Anti-vibration shock absorbers Steel chassis Robust construction designed for continuous or emergency applications Stainless steel fittings Emergency stops Easy access to the power connection Reinforced chassis for heavy range Easy access for chassis cleaning Silent-block with anti-corrosion protection between the genset and the chassis Easy access to fill radiator through the roof 09 Electrical System Heating resistor (standard on sets with automatic control panels) Battery charge alternator with ground connection Ground connection electrical installation with connection ready for ground spike (not supplied) Power panel with safety protection in output terminals box (open thermal magnetic protection and alarm) Maintenance-free and anti-explosion battery Battery isolator

PDF Summary Created : 28/02/2018 20:53 Author : Himoinsa Number of pages : 10 Report Type: Data Sheet - Heavy range Generated by: HIMOINSA Engineering Dept. Page 1. Genset data Page 2. Engine Specifications. Generator Specifications. Page 3. Installation Data Page 4. Dimensions Page 5. Control Panel Model Page 6. Controller features (I) Page 7. Controller features (II) Page 8. Controller features (III) Page 9. Generator Features & Options Page 10. PDF Summary 10