Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

Similar documents
Concealite Life Safety Products Model: F5000 Series. Save These Instructions. Read and Follow All Safety Instructions

Installation Instructions Central Battery Units

MIRRORLITE RECESSED EMERGENCY LIGHTING

Self-Testing Industrial Series

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

Spectron Industrial Series

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

The Da-Lite Difference.

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

The Da-Lite Difference.

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

IMPORTANT SAFEGUARDS

INSTRUCTION BOOK FOR. Dual Masking Electrol

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

The Da-Lite Difference.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

MOTORIZED FOLDING CAMPER WINCH

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

LED Downlight Ceiling Fixtures

When using electrical equipment, basic safety precautions should always be followed including the following:

SAVE THESE INSTRUCTIONS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Installation Documentation ID-2663

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

Installation and Operation Instructions 10/04/13

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Advanced Netbook Charging Carts for 10 laptops or 20 netbooks

LED Recessed Troffer Retrofit Kit

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

MaxLite LED UTILITY WRAP FIXTURES

EMIU 720W Mini Inverter

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

SURE-LITES FBP140XLP Instruction Manual

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Installation Instructions Electric Heaters 5 20 kw

Utility Distribution Systems Installation, Operation, and Maintenance Manual

SAVE THESE INSTRUCTIONS

The Da-Lite Difference.

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

Installation Instruction

Follow product label information and instructions. Qualified Personnel must perform all servicing or relamping of this product.

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

STEP-BY-STEP INSTALLATION GUIDE

UL AND CODE COMPLIANCE

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

INSTRUCTION BOOK FOR. Tensioned Large Advantage Deluxe Electrol

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

Illuminator System Series CM

Electric Vehicle Charging Station

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

The POWER. In PRESENTATION PRODUCTS. Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC.

3875 Cypress Drive Petaluma, CA Fax

Installation Instructions For Motor Control Center (MCC) Units

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

Instruction Book for. ContouR ElECtRol

MOTORIZED FOLDING CAMPER WINCH

Swing Arm Magnifying Lamp

Installation Instructions and User Manual For. 100 Watt Inverter Power System

E.S.P. Embedded Sensing Probes for Motor Brushes

Solstice Electric Fryers SE Series Service Manual

ALL W INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTALLATION GUIDE AND USER MANUAL

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION GUIDE AND USER MANUAL

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

CVR-625. Compact Vibrating Rod Instruction Manual

The Da-Lite Difference.

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

IBT Series Square Drive Torque Wrenches

Transcription:

Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions Important Safeguards When using electrical equipment, basic safety precautions should always be followed: Read and Follow All Safety Instructions 1. Do not use outdoors. 2. Do not let power cords touch hot surfaces. Do not mount units where they will be exposed to direct sunlight, radiators, gas or electric heaters. 3. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 4. CAUTION: Halogen lamps are used in this equipment. To avoid shattering, do not operate lamp in excess of rated voltage, protect lamp against abrasion, scratches and liquids when lamp is operating. Dispose of lamp with care. 5. Halogen lamps operate at high temperatures. Do not store or place flammable materials near lamps. 6. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 7. Do not use this equipment for other than intended use. 8. Qualified service personnel should perform servicing of this equipment. Model: R4000 Series AC Supply Voltage: 120/277 Volts (+ /-10%) Power Consumption: R4-20 = 40 Watts R4-35 = 70 Watts R4-50 = 100 Watts R4-75 = 150 Watts 358 degrees universal swivel rotation. 180 degree tilt position adjustment. Instructions for Installation Operation Service 202 Elk Street PO Box 160 Elkton, SD 57026 Phone: 605-542-4444 Fax: 605-542-3333 Website: www.concealite.com Copyright, Inc. All Rights Reserved Specifications subject to change without notice. Printed in U.S.A. 1

Step #1: Back box Installation The recessed back box is standard. If your installation requires the Surface Mount or Retrofit Back box, please refer to the separate instructions for back box installation. Minimum 5/8" wall or ceiling material required for flush mounting Back box is designed for recessed mounting In gypsum board or plaster wall or ceiling. When used in plaster wall or ceiling, install plaster trim option. Back Box Side View Total Depth of 4.1/8" required for flush mounting Provide 6.75 wide by 7.25 high area opening in wall or ceiling material to accept fixture head assembly. Dimension matches opening area of back box enclosure. 6.75"wide by 7.25"high fixture head opening Back Box Front View 1. Securely fasten back box to stud, joist or blocking material using tabs at top and bottom of back box with screws (not furnished). 2. For Wall Mounting-Mount with knockouts at top end. Attach Tinnerman 3. For Ceiling Mounting-Mount ClipHere with opening of back box downwards. 4. Route branch circuiting in metallic raceway. Securely terminate into enclosure by KO's provided. 5. Install tinnerman clips over oblong holes in sides of back box and screw bolts halfway in. 6. Install gypsum board or plaster wall or ceiling material. 7. Provide a 6.75"wide by 7.25" opening in wall or ceiling material to accept fixture head assembly. Dimension matches opening area of back box enclosure. ChargerBoard Secton Fixture Head Secton Plaster Trim Mounting Detail Note: Plaster trim is only needed for actual plaster material installation. Backbox Interior Slide plaster trim into back box opening Step #2: Branch Circuit Installation Verify primary input voltage as either 120VAC or 277VAC. Please confirm that the primary voltage is the same as what is labeled on the transformer cradle. The transformer board shipped with the unit is designed specifically for the emergency and normal voltage and the wattage specified on your order. NOTE: The color of the positive and negative wires for both normal and emergency power are noted on the transformer cradle. If the fixture is specified with generator only leads, only emergency power leads are provided. Provide each unit with a single unswiitched supply from (normal power) 120 VAC / 277 VAC branch circuit used for normal lighting in the area to be protected. The wiring should be a permanent installation using metal enclosed raceway. A 13/16" diameter knockout is provided on the top of the recessed or retrofit backbox. 120V/277V Transformer Cradle Connect to fixture head (Number of wires & color will vary depending on the wattage&. voltage, Connector wilt correspond ID Wiring on the fixture head) Normal Power Black - Positive White - Negative Emergency Power Red - Positive Yellow - Negative 2

Provide Grounding Verify Primary input voltage prior to termination : Step #3: Transformer Board Installation Carefully slide transformer board assembly into the top fo the back box. Step #4: Place tab in back box lance. Primary Input Wires Step #5: Fixture Head Installation Connect the Molex connector from the transformer board to the connector on the fixture head. The number of wires between the transformer board and fixture head are determined by the voltage and wattage of the ordered unit. Transformer Board Cradle Connect Fixture Head connector to transfromer board connector To Fixture Carefully place transformer board cradle in back box. Make primary AC connections Fixture Head Assembly Step #6: Fixture Head Mounting Screw the socket head screws partially in the tinnerman clip on the side of the back box. If not already done. Slide fixture head onto the heads of the two socket head bolts until flush with wall or ceiling surface. With the door in a half open position, securely tighten the socket head screws evenly to each side of the back box with the allen wrench provided. 3

Step #7: Lamp Installation Insert the locking bi-pin lamps by inserting the lamp into the lamp socket and rotate clockwise until locks in place. Step #8: Energize primary branch circuit. Troubleshooting Symptom Unit does not operate when power is lost. Lamp(s) does not energize when in Emergency mode, but door rotates open Possible Corrective Measure(s) Verify AC power is energized to the unit. Verify wiring connection between Power source & fixture. Remove lamp(s) and check lamp with resistance meter to verify condition. Resistance indicated good lamp. Open (no) resistance indicates bad lamp, replace lamp & retest. Taking a Unit Out of Service If there is any chance that a unit taken out of service may later be used on a different VAC circuit, tag the unite s current primary input selection as either 120VAC or 277VAC. Warranty All Concealite fixtures are tested and are guaranteed to be free from defective materials and workmanship for a period of three years from date of shipment under normal operations and proper use. Correction of all defects shall be by replacement or repair (at our option) and shall constitute fulfillment of all manufacturer s obligations. We will not allow any charge for labor, materials, etc that does not have our written approval before the work is begun. Damage incurred in handling or in transit are not covered by this guarantee. Any other warranty, expressed or implied, is hereby void. Modification to the product or failure to follow installation instructions will void the warranty. On Site Painting Instructions 1. The door and frame of the unit have been factory painted with a powder-coated paint with a hard finish. This finish should be roughened with a coarse steel wool or sandpaper before a new finsh is applied to ensure the paint adheres to the factory finish. 2. When the new finish is applied, extreme care should be taken that a seal is not formed between the door and the frame, which would prevent the door from opening. Also, assure that the paint is not so heavy that it runs into the gearing mechanism. This damage will void the warranty on the unit. 3. If the finish is sprayed on, we suggest that a thin cardboard or plastic strip be inserted between the door and the frame to prevent a paint seal from being formed. 4. After the new finish is applied, a sharp edge such as a single edge razor or utility knife may be inserted in the opening between the door and frame and run around the circumference of the unit to ensure that no seal has been formed. The finish should be completely dry before this step is performed. 5. If the unit is being covered with material (wallpaper, cloth, laminate, etc.), allow the mastic used to apply the covering to completely set up. Use a sharp edge such as single edge razor or a utility knife held at a 20 to 30 degree angle against the frame and run the blade around the frame. Repeat this procedure holding the edge against the door. This will provide a beveled edge that will prevent the material from fraying as the unit operates. 4

Information Bulletin Power Requirements for the R4000 Series There are two ways to power the R4000 Series Emergency Fixture. Method #1 (one circuit) Provide one emergency power circuit that is energized during the operation of the generator. This can be sourced from the emergency panel circuit breakers typically located on the generator itself. Dedicated circuit breakers must be called out as part of the generator specifications. The emergency circuit voltage must be specified and can be either 120 Volt or 277 Volt AC. Item # Example: Concealite R4 Wattage 120E/Generator Leads Only or R4 Wattage 277E/Generator Leads Only Method #2 (two circuits) The R4000 only needs to be powered during the emergency mode. The R4000 automatically returns to the closed position when the emergency circuit is de-energized. However, monitoring what is actually happening within the area and supply sources available dictates whether one or two input circuits are needed. Provide one emergency power circuit from a building emergency panel. This is typically a panel that is constantly supplied by normal power & backed up by emergency power via an automatic transfer switch from a generator. This emergency circuit would basically serve the R4000 with a constant hot emergency source, so we need to notify the R4000 when an actual emergency condition is occurring. Provide one normal power circuit from a building normal power panel that is not backed up by an emergency source. This circuit would power a relay in the R4000 that would sense the loss of normal power and close the contact on the emergency circuit serving the R4000 during emergency mode. The emergency and the normal branch circuit voltages must be specified and can be any combination of 120 Volt or 277 Volt AC. Item # Example: R4 Wattage 120N/120E or R4-wattage 277N/277E R4 Wattage 120N/277E or R4-wattage 277N/120E Copyright, Inc. All Rights Reserved Specifications subject to change without notice. Printed in U.S.A. 5