Similar documents
F3000-B2B, F3000-B2M FILTRATION SYSTEM INSTRUCTION MANUAL

Full Flow Drinking Water System Model: 3MFF100

FILTER KIT. HWF172 Watersentry VII Kit (Lead, Aesthetic Chlorine Taste & Odor & Particulate Class I Reduction) FOR COMMERCIAL USE ONLY

Owner s Manual WARNING

model 2000SN FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS Recessed Wall-Mount Bottle Filling Station

FILTER KIT EWF172 Watersentry VII KIT (Lead, Aesthetic Chlorine Taste & Odor & Particulate Class I Reduction) FOR COMMERCIAL USE ONLY

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Model 2000SMS/2000SMSN Bottle Filler with Lifecycle Control

PURE WATER. Installation, Operation and Maintenance Manual. 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG. Important.

Installation Instructions AQ-4000 Countertop Water Filter. White, Black, and Brushed Steel finishes

Installation Instructions

GE Infrastructure Water and Process Technologies. Merlin Point of Use Drinking Water System. Installation and Maintenance Manual

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

Installation, Operation and Maintenance Manual

Installation and Operation Manual

INSTALLATION INSTRUCTIONS

MULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation and Operating Instructions

Installation Instructions 1662SG SG.222

NSF MODELS: CTP200, CTP100. This System does not require the services of a plumber. Read and Save these Instructions. Important

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Installation Instructions

Installation Instructions

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

Installation, Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS

Installation Instructions 1662SG SG.224

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Installation Instructions

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Operating Manual for Hands-Free Wall Mounted Sinks Models 607D and 607D-0.5

MIZU QUICK CHANGE DUAL FILTER SYSTEM

Operating Manual for Hands-Free Wall Mounted Sinks Models 504 and

Water Filtration. system. GEAppliances.com. Safety Instructions...2 Operating Instructions Specification Guidelines...3 Using the System...

Use & Care Manual D R I N K I N G W A T E R S Y S T E M S. IMPORTANT: Read and Save these Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions 1662SG SG.223

Water Filtration System

Scale Feeder Manifold Water Filtration System Instruction Manual

INSTALLATION INSTRUCTIONS

The ionpia H 2 Owner s Manual

OWNER S GUIDE. 104 Series ADVANCED MULTI STAGE WATER TREATMENT SYSTEM 104 SERIES

SPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Minimum Working Pressure kg/cm 2 (10 PSI) Maximum Water Temperature C (110 F) Recommended Tap Water Flow Rate LPM (0.

ETF-600 Sensor Operated Lavatory Faucet

Installation and Operation Manual

Water Filtration System

Installation Instructions

INSTALLATION INSTRUCTIONS STUDIO S

Installation Instructions

INSTALLATION INSTRUCTIONS PATIENCE

House Hydrant Installation Instructions

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

Dual Flow Manifold Systems Instruction Manual

MAC FAUCETS FA400 WALL MOUNT FAUCETS

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions Series Series

K5 Drinking Water Station Installation Instructions

FOR TECHNICAL ASSISTANCE

ONE. Cartridge Tank Filters

A1004LV. Polished Chrome Polished Nickel Satin Nickel Ø1 1/32 2 1/8

AQUA2000 From O3PURE

Installation Guidelines

Installation Instructions: Side Delivery Units BDS-2555

Installation Instructions

½ DODGE CUMMINS

Viking Installation Guide

I-799/79V Coil Components

US Water Systems Magna Pre-Filter

Set Up Instructions. Powered Water Filtration System. We re here to help! Quick Start

ONLINE WARRANTY INFORMATION CrystalQuest.com/warranty.html

Installation Instructions

Installation Instructions

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

Dual Port Manifold Water Filtration Systems Instruction Manual

Installation Instructions

INSTALLATION INSTRUCTION & OWNER S MANUAL

RX-AFRO3-AQ Installation Manual

Installation Instructions

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-1000 EYESAVER FAUCET DESCRIPTION

Installation Instructions

Owner s Manual. VZN Water Filtration VZN-421H, VZN-441H. Manufacturing Numbers: P/N /09

INSTALLATION INSTRUCTIONS

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4020B

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

Central Brass REPLACEMENT PARTS. MODEL NOS Three-Valve Bath & Shower Fitting Direct Sweat 8-inch Centers

½ DODGE CUMMINS

Residential R.O. components

Installation and Maintenance Instructions

Installation Instructions

Aplos Single Lever Basin Faucet

Eye Wash Unit S0201 for Scrub Sinks

ALTERNA DECK/BATH-MOUNT BATH FAUCET

Transcription:

Important The Drinking Water Filter with MACguard will not make biologically unsafe water safe to drink since activated carbon will not kill bacteria. When applying the filter to non-chlorinated water supplies, additional treatment steps may be necessary to assure the water s bacterial makeup is compatible with activated carbon final treatment. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Read all steps, guides and rules carefully before installing and using the Kinetico Drinking Water Filter with MACguard. PRE-INSTALLATION CHECKLIST Before starting installation, check the contents of the box for the following components: See Figure 1 Drinking water faucet assembly*, consisting of: Faucet base assembly (1) Faucet spout (1) Small black rubber gasket (1) Chrome escutcheon (1) Large black rubber gasket (1) Black locating washer (1) Metal washer (1) 9/16 brass nut (1) MACguard head with bracket (1). Taste and odor reduction cartridge Product No. 9306B for Model 7000 (1). Lead, VOC, and cyst reduction cartridge Product No. 9308A for Model 7500 (1) Decorative cover with PureMometer indicator window (1) Tubing hook-up kit, consisting of: 5/8 bracket mounting screws (2) 1/4 tube x 1/4 tube faucet connector (1) 3/8 tube x 3/8 tube x 1/4 tube tee (1) 1/4 NPT x 1/4 tube elbow (1) (Model 7500 uses flow control elbow) 1/4 NPT x 1/4 tube elbow shutoff valve (1) 1/4 O.D. tubing (not pictured) * Included with certain models only. Figure 1. Typical Package Contents 1

INSTALLATION INSTRUCTIONS Installation must comply with state and local codes and regulations. Tools/Items Required Utility knife or tubing cutter Teflon tape Pliers Drill Phillips-head screwdriver 9/16 Wrench or basin wrench It is recommended that before purchasing a water treatment unit, you have your water tested to determine your actual water treatment needs. The with MACguard must be mounted in a vertical position, and the total hookup distance should be limited to not more than 15 feet. 1. (For systems installed with a faucet.) Determine the best location for the drinking water faucet on the sink using an existing sprayer hole or other pre-drilled hole. If you have to disconnect and remove your faucet sprayer, follow the instructions provided by the faucet manufacturer. WARNING If you do not have an existing hole that can accommodate the drinking water faucet, you will have to drill one yourself or have one professionally drilled. Do not attempt to drill a hole into your sink unless you have previous experience doing so and have the necessary tools. Contact the manufacturer of your sink for instructions on how to drill a separate hole. If you need further assistance, your local Kinetico dealer can install the system for a nominal charge. Faucet Spout Follow these steps to install the faucet on the sink top. Slide the small black rubber gasket onto the threaded shaft on the faucet base. Slide the chrome escutcheon onto the threaded shaft to the small black rubber gasket. Slide the large black rubber gasket onto the threaded shaft to the escutcheon. Insert these assembled parts into hole in sink top. Note: It will be helpful at this time to have an assistant hold the faucet base on the sink top. Working from under sink, slide plastic locating washer (small diameter up) onto threaded shaft and hold in place. Slide metal washer onto threaded shaft and hold in place against locating washer. Thread the 9/16 brass nut onto the threaded shaft. Hold faucet base on sink top firmly and tighten nut up to the metal washer. Remove plastic tubing insert from top of faucet base. Firmly insert the spout into the faucet base. Faucet Base Small Gasket Chrome Escutcheon Large Gasket Sink Top Locating Washer Metal Washer Brass Nut 2

CAUTION Over tightening of any threaded fitting could result in damage to the fitting or the filter head. 2. Apply Teflon tape to the plastic male elbow (See Figure 2), and install it into the outlet on the right side of the filter head/bracket assembly (See Figure 3). Flow Control Elbow Standard Elbow Figure 2. Elbows Figure 3. Elbow Installation Model 7500 uses a Flow Control elbow to ensure your water has adequate contact time with the carbon inside of the filter cartridge. Model 7000 uses a standard elbow. 3. Apply Teflon tape to the male end of the shutoff valve provided and install it into the inlet on the left side of the filter head (See Figure 4). Hand tighten the valve until it is firmly in place. Figure 4. Shutoff Valve Installation 3

4. Remove the plastic wrapping from the filter cartridge. Remove the small plastic cap from the top of the filter cartridge (See Figure 5). Install the cartridge into the filter head/bracket assembly by firmly inserting it and rotating it counterclockwise until it stops. Figure 5. Filter Cartridge Cap Removal 5. Determine the desired location for the filter system. It should be easily accessible for cartridge replacement. Be sure to leave adequate clearance under the filter to facilitate cartridge changes and allow for easy viewing of the PureMometer filter life indicator. Do not install in direct sunlight. The screws provided are for use with structurally sound wood surfaces. You may need other mounting hardware if you are mounting on other surfaces. Warning Do not use the fittings provided on chrome tubing. If your plumbing type requires different fittings than those provided, you may obtain them at a local hardware store or home improvement center. 6. Using the bracket mounting screws, mount the filter system in the location you have chosen (See Figure 6). 7. Locate the cold water line you will tap into to supply water to the filter system. DO NOT USE THE HOT WATER LINE. Turn off the water to the cold water feed line. Plumb in a hookup with the ability to connect to ¼ tubing (See Figure 77). A tee fitting is provided to accommodate most installations. The installation must comply with state and local codes and regulations. SPECIFICATIONS: Service Flow Rate: Model 7000: 3.75 Lpm (1.0 gpm) Model 7500: 2.84 Lpm (0.75 gpm) Min./Max. Operating Pressure: 137.9-827.4 kpa (20-120 psi) Min./Max. Operating Temperature: 2-38 C (35-100 F) Capacity: 1,892 L (500 gal) 4

Figure 6. Filter Bracket Installation Figure 7. Water Supply Connections 8. Insert one end of the ¼ tubing provided into the ¼ outlet on the fitting plumbed into the cold water line (See Figure8). You may need to trim the length of the tubing to accommodate your installation. Insert the other end into the elbow/shutoff valve fitting on the inlet on the left side of the filter head/bracket assembly (See Figure 9). Figure 8. Cold Water Supply Connection to Tee Fitting Figure 9. Cold Water Supply Connection to Shutoff Valve 9. Push one end of the ¼ tube x ¼ tube faucet connector onto the ¼ tubing that is attached to the faucet assembly (See Figure 10). Note: Depending on the installation, the tubing that is attached to the faucet assembly may reach the outlet elbow of the filter head/bracket assembly without using the faucet adapter and an extra length of tubing. Be sure this line is not pinched or stressed at the fittings. 10. Install a length of ¼ tubing from the faucet connector into the outlet elbow on the right side of the filter head/bracket assembly (See Figure 11). 5

Figure 10. Figure 11. Faucet Connector Installation Filter Head/Bracket Assembly Water Connection 11. Turn on the water to the cold water feed line. Open the shutoff valve on the system (See Figure12). 12. Open the drinking water faucet for approximately 15 minutes to purge any air and carbon fines (particles) from the system. Carbon fines are present in all carbon cartridges and are a result of normal manufacturing. Closed Open Figure 12. Shutoff Valve Operation Figure 13. Decorative Cover Installation 13. Close the drinking water faucet and check all connections for leaks. 14. Place decorative cover onto filter head/bracket assembly (See Figure 13). Replacement filter cartridges are available from your local authorized Kinetico dealer, at www.kinetico.com or by calling 1-800-944-WATER (9283). The (Models 7000 and 7500) with MACguard is tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of aesthetic chlorine, taste and odor. Model 7500 is also tested and certified by NSF International against NSF/ANSI Standard 53 for lead, VOC and MTBE as verified and substantiated by test data. DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM. 6