COYOTE STP (Service Termination Point)

Similar documents
COYOTE STP (Service Termination Point)

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE LCC (Low Count Closure)

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

COYOTE Terminal Dome Closure 6.5" x 22"

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

INSTALLATION INSTRUCTIONS

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Environmental Distribution Center (EDC-06P-NH)

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

INSTALLATION INSTRUCTIONS

FOG LAMPS INSTALL KIT

Fiber optic splice closure

Fiber Splice Panel Rack Mount User Manual

Section 1 COYOTE Closure Series

INSTALLATION INSTRUCTIONS

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

Fiber Connector Shelf (CCS)

Closure End Plates and Accessories

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

K9-C23 INSTALLATION INSTRUCTIONS K9 Kit for CHEVY TAHOE PPV (9C1)

CS Fiber Optic Splice Case. Instruction

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

INSTALLATION INSTRUCTIONS

8400 Series Fiber Distribution System

SUT-450-I ASSEMBLY REQUIREMENTS

Ford F150 SuperCab A Ford F150 SuperCrew A

Ford F150 SuperCab Ford F150 SuperCrew

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

WRSS Wraparound Repair Sleeve Installation Instructions

INSTALLATION INSTRUCTIONS

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

INSTALLATION INSTRUCTIONS

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

INSTALLATION INSTRUCTIONS

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Conflicts None. TOYOTA TUNDRA 2017 Black Laser Cut Grille. Part Number: Accessory Code: BG3000. General Applicability

- MK7 Mirror Integration Kit - Installation Instructions

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

INSTALLATION INSTRUCTIONS

FL2000 Termination/Splice Panels User Manual

Air Conditioner for M915 A0/A1 Truck

Please read thoroughly before starting installation and check that kit contents are complete.

INSTALLATION INSTRUCTIONS


LEXUS RC 350/RC-F ILLUMINATED DOOR SILLS Preparation

Universal Splice Tray Installation Instructions

TESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

INSTALLATION GUIDE. AMP RESEARCH TECH SUPPORT (Press 2) Monday - Friday, 6:00 AM - 5:00 PM PST

Section 1 COYOTE Closure Series

INSTALLATION & OWNER S MANUAL

w w w. h d o n l i n e s h o p. d e CRUISE CONTROL KIT GENERAL INSTALLATION -J04064 REV Kit Number Models Additional Parts Required

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

FOG-LAMPS INSTALL KIT

INSTALLATION INSTRUCTIONS

The world's first Bolt in Only stress bar for VW Mk 4 Chassis. Installation Manual V1.0.

Installation Guide. Stowe Cargo Management System. Table of Contents

Assembly Instructions

INSTALLATION GUIDE P1000 PRO-CELL CURRENT FORD POLICE UTILITY INTERCEPTOR. pro-gard.com STRONG RELIABLE SECURE

INSTALLATION INSTRUCTIONS

RZ3-5K Polaris RZR XP 1000 & 900 Kicker 5 Speaker Audio Kit

HVS S 15kV Class

INSTALLATION INSTRUCTIONS

CorkSport ort Mazda 3 Adjustable Shifter Mazdaspeed 3, Mazda 3 6-speed and Mazda3 SkyActiv 6-speed

SCION FR-S FOG LIGHTS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

STEP 1 STEP 2. Disconnect the negative terminal from both batteries.

PARTS TOOLS. Set Screw. Washer (2) Blue Bushing (2) Black Bushing (2) B&M Short Throw Shifter. Jam Nut Grease. Retaining Ring (2) Insert (2)

SUT-250-S (These instructions are used for SUT-250-SCLC also)

AM-676, AM , AM-690-R, AM-692, AM-693-R, AM-762, and AM-763

Section 1 COYOTE Closure Series

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

INSTALLATION INSTRUCTIONS

Stowe Cargo Management System

INSTALLATION INSTRUCTIONS

PRELIMINARY INSTALLATION INSTRUCTIONS. PARTS LIST Left front trim piece

Section 3 FIBERLIGN Closure Series

OPTICAL FIBER CLOSURE

Transcription:

March 2019 COYOTE STP (Service Termination Point) Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product before application. 1 2 3 4 5 6 7 8 9 NOMENCLATURE 1. Base (1) 2. Cover (1) 3. Splice Platform (1) 4. Grommet Kit (1) 5. Small Parts Bag (1) OPTIONAL ITEMS 6. Bulkhead Kit (1 7. Pigtail Kit (1) 8. Bonding Kit (1) 9. Direct Cross-Connect Kit (1) TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket wrench Fiber optic cable opening tools Phillips Screwdriver Snips PLP Catalog Number STP-GG-1-N-0-N STP-EE-2-N-0-N STP-GG-3-1-2-2 STP-GG-3-1-1-2 STP-EE-4-1-2-2 STP-HH-5-1-2-N COYOTE STP Kits and Accessories Description COYOTE STP Kit Splice Only: Includes (2) G Grommets COYOTE STP Kit Splice Only with Bonding: Includes (2) E Grommets COYOTE STP Kit Cross-Connect: Includes (2) G Grommets, (2) SCAPC Adapters, and (4) 3 mm Yellow Jacketed Pigtails COYOTE STP Kit Cross-Connect: Includes (2) G Grommets, (1) SCAPC Adapters, and (2) 3 mm Yellow Jacketed Pigtail COYOTE STP Kit Cross-Connect with Bonding: Includes (2) E Grommets, (2) SCAPC Adapters, and (4) 3 mm Yellow Jacketed Pigtails COYOTE STP Kit Direct Cross-Connect: Includes (2) H Grommets and (2) SCAPC Adapters 80061322 COYOTE STP Cable Shroud Kit 80061323 COYOTE STP Pedestal Mounting Bracket Kit for Charles Industries PEDLOCK BD4 and BD5 Buried Cable Pedestals PEDLOCK is a registered trademark of Charles Industries Ltd. 1

Step #1 General Cable Preparation Measure each cable to determine the diameter of the cable and select the proper grommet(s) for your application. Step #2 Insert each cut cable in the appropriate grommet. If the cable is expressing fiber, slit the grommets as shown below before installing the grommets over the cable. (See Step #1 for slit locations for each grommet) For Cut Applications NOTE: The lines on each grommet represent the slit locations for cables expressing fiber or preconnectorized drop cables. For Expressed Applications Small Grommets Cable Diameter Range A B C D E F G H J SOLID / NO HOLE FOR ROUND DROP DIAMETERS.100" -.154" (2.5-3.9 mm) FOR ROUND DROP DIAMETERS.154" -.25" (3.9-6.4 mm) FOR ROUND DROP DIAMETERS.25" -.35" (6.4-8.9 mm) FOR ROUND DROP DIAMETERS.35" -.389" (8.9-9.9 mm) FOR ROUND DROP DIAMETERS.389" -.425" (9.9-10.8 mm) FOR FLAT DROP CABLES FOR ROUND DROP DIAMETERS.100" -.123" (2.5-3.1 mm) FOR ROUND DROP DIAMETERS.154" -.188" (3.9-4.8 mm) For Expressed Applications Use Snips to Slit the Grommet Slit 2 2019 Preformed Line Products Company. All rights reserved.

Step #3 If the cable is a figure 8 style cable or has a tracer wire, remove the ground wire or tracer wire from the portion of the cable that will be positioned in the grommet and insert the cable into the grommet. Remove any burrs left on the cable caused by separating the tracer wire from the sheath. Step #6 Measure, mark, and remove the cable sheath for expressed fiber applications as shown below. 33.5" (85 cm) Cable with Tracer Wire Not Correct Installation Figure 8 Style Cable Correct Installation Preparation of the Drop Cables Flat Drop Cables Not Correct Installation Correct Installation Step #4 Install a plug into any unused hole of each grommet. Step #7 Trim the cable strength members as close to the cable sheath opening as possible and remove the buffer tube 1/2" (13 mm) away from the sheath opening. 1/2" (13 mm) Step #5 Measure, mark, and remove the cable sheath for cut cable applications as shown below. 32.5" (83 cm) 3

Round Drop Cables without Aramid Yarn Installation of Flat Drop Cables in the Splice Platform Step #8 Remove the buffer tube 1/4" (6 mm) away from the sheath opening. 1/4" (6 mm) Step #11 Adjust the cable so that the cable sheath opening is positioned 1" (25.4 mm) from the grommet. 1" (25.4 mm) Round Drop Cables with Aramid Yarn Step #12 Align the cable sheath opening with the edge of the retention tab of the platform and insert the cable retention clip into the retention clip slot. Step #9 Remove the buffer tube 1/4" (6 mm) away from the sheath opening. Braid roughly 2" (51 mm) of aramid yarn. 1/4" (6 mm) Edge of Retention Tab 2" (51 mm) PLP Tip: Use a can wrench to push the cable retention clip down into the slot. Armored Round Drop Cables Step #10 Remove the armor 1" (25 mm) away from the sheath opening. Remove the buffer tube 1/4" (6 mm) away from the end of the armor. Bend the steel strength members 90 degrees and cut them 3/4" (19 mm) from the bend at the sheath opening. 3/4" (19 mm) 1/4" (6 mm) 1" (25 mm) 4

Installation of the Round Drop Cables without Aramid Yarn in the Splice Platform Step #16 Wrap the end of the cable with a piece of felt and secure the cable to the retention tab with the tie wrap. Step #13 Install a tie wrap under the cable retention tab of the platform. Align the end of the buffer tube with the end of this wall before securing the cable. Felt Cable Retention Tabs Step #17 Install a self-tapping screw halfway in the boss next to the cable. Step #14 Wrap the end of the cable with a piece of felt and secure the cable to the retention tab with the tie wrap. Align the end of the buffer tube with the end of this wall before securing the cable. Self-Tapping Screw Felt Step #18 Wrap the braided aramid yarn clockwise around the threads of the screw and tighten the screw down. Installation of the Round Drop Cables with the Aramid Yarn in the Splice Platform Step #15 Install a tie wrap under the cable retention tab of the platform. Cable Retention Tabs 5

Installation of the Round Armored Drop Cables in the Splice Platform Step #19 Place a bolt through the bottom of the platform and place one of the bonding clamp halves on the bolt as shown below. Step #21 Place the other half of the bonding clamp on the bolt as shown below. Install a small hex jam nut on the bolt and tighten the nut to secure the cable. Small Hex Jam Nut Make sure the head of the bolt seats in the hex pocket of the platform Fiber Routing in the Platform Step #22 Route the expressed fi bers. Bonding Clamp Half Step #20 Position the bent steel strength members of the armored drop cable into the side retention pocket of the platform. Side Retention Pockets 6

Straight Splice Applications Step #24 Route the outgoing fibers. Step #23 Route the incoming fibers. OR OR 7

Step #25 Splice the incoming fibers to the outgoing fibers per your accepted company practice. Standard Cross-Connect Applications Step #27 Route the outgoing fibers. Outgoing Fiber 1 Step #26 Route the incoming fibers. Incoming Fiber 1 Outgoing Fiber 2 Incoming Fiber 2 8

Step #28 NID Applications Route the incoming fibers. NOTE: If needed, a fiber pick is included to help maneuver the fibers into the routing channels of the platform. Incoming Fiber 1 Fiber Pick Preparation and Routing of Pigtails for Cross-Connect Applications Step #29 Measure and mark the jacket of the pigtail(s) as shown below. Remove the jacket of the pigtail(s) beyond the marked location. Pigtail with 3 mm Yellow Jacket Jacket Length = 11" (27.9 cm) Incoming Fiber 2 Pigtail with 900um Colored Jacket Jacket Length = 12" (30.5 cm) Step #30 Splice the incoming fiber(s) to the incoming pigtail(s) and the outgoing fiber(s) to the outgoing pigtail(s) per your accepted company practice. 9

Standard Cross-Connect Applications Step #31 Route the incoming pigtail(s) in the platform from the splice to the bulkhead location. Step #32 Route the outgoing pigtail(s) in the platform from the splice to the bulkhead location. Routing for 1st Outgoing Pigtail Routing for 1st Incoming Pigtail Routing for 2nd Outgoing Pigtail Routing for 2nd Incoming Pigtail 10

Step #33 NID Applications Route the incoming pigtail(s) in the platform from the splice to the bulkhead location. Step #34 Install the adapter(s) into the bulkhead bracket. Adapters Routing for 1st Incoming Pigtail Bulkhead Bracket Step #35 Place the bulkhead bracket onto the platform and insert the pigtail connector(s) into the adapter(s). Standard Cross-Connect Routing for 2nd Incoming Pigtail NID 11

Installation of Splice Platform into the Base Standard Straight Splice and Cross-Connect Applications Step #36 Adjust each grommet so that they are positioned 1/4" (6 mm) from the platform. Step #38 Place the platform onto the posts located in the base while inserting the grommets into the grommet pockets of the base. 1/4" (6mm) Grommet Pockets Posts Step #37 Lubricate all four outer surfaces of each grommet. Once the lubricant has been applied, smear it to provide a light coating on each surface. Lubricate sealing surfaces of grommet with silicone lubricant provided. Step #39 Secure the platform to the base with the self-tapping screws that are provided as shown below. Splice Only Platform Self-Tapping Screws Self-Tapping Screws Cross-Connect Platform 12

NID Applications Step #40 Using a hole saw, drill a 7/8" (22 mm) hole through the outside wall of the house/building/structure as shown below. Step #42 For applications where conduit will be used, make sure that the conduit is no larger than.840" (21 mm) O.D. While installing the conduit make sure to adjust the conduit so that when the base is installed on the wall the threaded portion of the conduit protrudes 1/4" (6 mm) through the base. 1/4" (6 mm) Step #43 Place sealant around the pass through port on the back of the base per your standard company practice. Step #41 Using a hole saw, drill a 7/8" (22 mm) hole through the pass through port of the base. Step #44 Align the pass through port with the hole or conduit in the wall and mount the base to the wall of the house/building/structure with screws or bolts (not provided). IMPORTANT NOTE: If cable bonding/grounding is required, see Step 53 prior to securing the base to the wall. Mounting Tab Mounting Tab 13

Step #45 Place the platform onto the posts located in the base while inserting the grommet(s) into the grommet pocket(s) of the base. Step #48 If only one cable is entering the closure, then lubricate (Step 37) and insert either a grommet with a plug or a solid grommet into the empty grommet pocket. Posts Grommet Pockets Solid Grommet Step #49 Route the outgoing pigtails in the platform. Step #46 Secure the platform to the base with the self-tapping screws that are provided as shown below. Self-Tapping Screws Step #47 For applications where conduit is used, secure the conduit to the base with a lock nut (not provided). Lock Nut 14

Step #50 Insert the connectors of the outgoing pigtails into the adapters of the bulkhead. Bonding Armored Drop Cables Step #51 Remove the protective cap from the ground stud. Place the bonding bracket on the bonding clamp bolt(s) and the ground stud of the base. Secure the bracket to each bonding clamp bolt with a small hex jam nut. Ground Stud Bonding Bracket Installation of the Bulkhead Shroud onto the Platform (Standard Cross-Connect and NID Applications) Small Hex Jam Nuts Step #52 Secure the bonding bracket to the ground stud with the large hex nut. OPTIONAL STEP: Angle the shroud and place the tab of the shroud in the slot of the bulkhead. Rotate the shroud downward and secure the shroud to the platform with a self-tapping screw. Large Hex Nut Shroud Tab Slot in Bulkhead Step #53 Attach a ground wire to the ground stud with the large hex jam nut and ground per your standard company practice. Self- Tapping Screw Large Hex Jam Nut 15

Direct Cross-Connect Applications Cable Routing for Standard Application Step #54 Install the adapter(s) into the bulkhead bracket and secure the bulkhead bracket to the base with the self-tapping screws that are provided. Step #57 Route the incoming cable(s) in the platform and install the connector into the adapter. Self-Tapping Screws Step #55 Install the push on routing clips onto the posts of the base as shown below. Push On Routing Clips OR Push On Routing Clips Step #56 For NID applications follow Steps 40 44. If conduit is used, secure the conduit directly to the base with a lock nut (not provided). Lock Nut 16

Step #58 Route the outgoing cable(s) in the platform and install the connector into the adapter. Cable Routing for NID Application Step #59 Route the incoming cable(s) in the platform and install the connector into the adapter. OR OR 17

Step #60 Route the outgoing cable(s) in the platform and install the connector into the adapter. Flat Drop Cables Step #61 Lubricate the grommet(s) (See Step 37) and place them into the grommet pocket(s). If there is an empty grommet pocket, make sure to install a grommet with a plug or a solid grommet in it. Solid Grommet The end of the cable heat shrink should be positioned at least 1/2" (13 mm) away from the grommet. Step #62 Insert the cable retention clip(s) into the retention clip slot(s) of the base. Retention Clip Slots Retention Clip OR PLP Tip: Use a can wrench to push the cable retention clip down into the slot. 18

Round Drop Cables Step #65 Secure the cable(s) to each retention clip with tie wraps. Step #63 Place the tie wrap retention clip(s) into the retention clip slot(s) of the base as shown below. 1 Cable per Port Tie Wraps 1 Cable per Port Retention Clip Slots Tie Wrap Retention Clip 2 Cables per Port Retention Clip Slots 2 Cables per Port Tie Wrap Retention Clip Tie Wraps Step #64 Lubricate the grommet(s) (See Step 37) and place them into the grommet pocket(s). If there is an empty grommet pocket, make sure to install a grommet with a plug or a solid grommet in it. Adjust the cable(s) as needed before placing a piece of felt around the cable(s) where the tie wrap retention clip is located. 1 Cable per Port Installation of the Cover and Latches Step #66 Position the hinges of the cover in the gap between the hinge posts and the outside wall of the base. Solid Grommet Felt 2 Cables per Port Step #67 Rotate the cover down until the hinge posts engage into the hinges of the cover. Solid Grommet Felt Felt 19

Step #67 CONTINUED Step #70 Install the latches onto the base and rotate the cover to the closed position. Secure the cover by pressing down on it while rotating the latches until they snap in place over the cover. The hinge posts are fully engaged when they are captured under the retention tabs of the hinges of the cover Step #68 To lock the cover in the open position, rotate the cover until the retention tabs of the base snap over the edge of the cover. Retention Tabs Step #69 Store the fiber pick in the holder of the cover. Step #71 Secure the cover to the base with the pin-in torx head self-tapping screw that is provided or use the security slot to use some other method that follows your standard company practice. Fiber Pick Retention Holder Security Slot Pin-In Torx Head Self-Tapping Screw SAFETY CONSIDERATIONS This application procedure is not intended to supersede any company construction or safety standards. This procedure is offered only to illustrate safe application for the individual. FAILURE TO FOLLOW THESE PROCEDURES MAY RESULT IN PERSONAL INJURY OR DEATH. Do not modify this product under any circumstances. This product is intended for use by trained technicians only. This product should not be used by anyone who is not familiar with, and not trained to use it. When working in the area of energized lines, extra care should be taken to prevent accidental electrical contact. Be sure to wear proper safety equipment per your company protocol. For proper performance and personal safety, be sure to select the proper size PREFORMED product before application. PREFORMED products are precision devices. To ensure proper performance, they should be stored in cartons under cover and handled carefully. P.O. Box 91129, Cleveland, Ohio 44101 440.461.5200 preformed.com email: inquiries@preformed.com SP3396-2 20