Trip Circuit and Trip coil supervision Relay

Similar documents
Type DTH 31, 32 DTTM 11, 12 High Speed Biased Differential Relays

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

B kv Gas-insulated Substations

6R MATRIX. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

Tattletale Annunciators and Magnetic Switches

REVISED ATM72 Auto Transfer Module

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

E.S.P. Embedded Sensing Probes for Motor Brushes

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

4.0 OPERATION Type ITH-T Relay

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

Application Engineering

GCU-10. Automatic Engine Control Unit Operators Manual

INSTRUCTION MANUAL A141 High Level Audible Warning System / Battery backup

MRTS Trip Circuit Supervision Relay

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

The X, Y, and Z of Circuit Breaker Control

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Magnetic Overload Relays

(Example) In case of DC24 to 48V, it is operating time for DC24V.

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

Auxiliary Relay. Type P8n, PQ8n, PN8n

Model HEA Multicontact Auxiliary

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

Application Engineering

GENSET CONTROL MODULE A121A / A241A

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Dual Power. Protection. Protection

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

DKG-114 MANUAL AND REMOTE START UNIT

Electronic Circuit Breaker ESS20-0..

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

SDM72 Start on Demand Modules

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Electromagnetic Industries LLP

Bistable Relay. Types PSU6n, PSU14n. Station Automation & Protection. ABB Substation Automation Products

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

Control panel. For 3 three-phase electric pumps with thermal protection and exchanger

LA Motor Protection. A South African Company to be Proud of

KD LV Motor Protection Relay

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

AKM 345 Gen2. Instruction Manual. Oil Temperature Indicator AKM OTI Type 34 Winding Temperature Indicator AKM WTI Type 35. Document ID: IST EN

B kv T&D GAS INSULATED SWITCHGEAR

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

CHAPTER 4 PROTECTION REQUIREMENTS

DeltaV SIS TMAuxiliary Components

CP Automatic capacitor bank

Central Battery Systems Loadstar AC/DC Systems

Auxiliary Relay. Type RXP8n, RXPQ8n

Bistable Relay. Types PSU6n, PSU14n.

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

MODEL No s: PP3, PP3K

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

SECTION MOTOR CONTROL

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Memshield - ACB Ratings & Specifications

GENERATOR & SINGLE-FUNCTION PROTECTION

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

COM Overcurrent Relay

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Auxiliary Relay. Type CV2

Bulletin 825 SMM Smart Motor Manager

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Scheda prodotto Relè Series E

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Breaker-failure protection RAICA

AF40... AF96 3-pole contactors Technical data

RVS-DN Digital Reduced Voltage Motor Starter

N1233 Series Troubleshooting Guide for N Alternator

Motor-drive mechanism, type BUL. Technical guide

INTERPLANT STANDARD - STEEL INDUSTRY

OTEC Transfer switch open transition

Transcription:

PROTECTION Trip Circuit and Trip coil supervision Relay Type VAX Customer Benefits: Trip circuit and trip coil supervision relay Choice of pre closing and post-closing supervision Simple and robust construction Only two variants based on Power Supply option: 110/220 and 24 /48 Completely dust proof by IP5X class protection Standard contact combination with 2NO+2CO, suitable for all possible application

PROTECTION Type VAX Trip circuit supervision relays Features Simple and robust construction Positive action without chatter Choice of pre-closing and post-closing supervision Application Post-closing or continuous supervision of the trip circuit of circuit breakers General Description Type VAX relays are of simple and robust construction. They are arranged to initiate an audible alarm and visual indication if the trip circuit of a circuit breaker fails or the breaker tripping mechanism does not operate Two versions of type VAX relays are available. Type VAX 21 relay monitors the trip circuit only when the circuit breaker is closed (post -closing supervision only) while type VAX 31 relay monitors the trip circuit continuously (both pre-closing and post-closing supervision). Both versions detect the following conditions. Failure of trip supply Open circuit of trip coil of trip circuit wiring Failure of mechanism to complete the tripping operation Type VAX 21 relay consists of two units connected. Under healthy condition with circuit breaker closed, both units are energized. If the trip circuit gets open or the trip supply fails, units A drops-off and opens contacta-1 to de-energize unit C. when the circuit breaker is open the auxiliary switch of the circuit breaker shorts contact A-1 to hold-in unit C. Type VAX 31 relay under healthy conditions with the consist of three units connected, circuit breaker closed, units A and C are energized and the operation is the same as that of type VAX 21 relays. When the circuit breaker is open unit B is also energized via the normally closed auxiliary switch of the circuit- breaker and unit C is held-in by contact B-1 Unit B will detect trip circuit abnormalities with the circuit breaker open in a similar manner as unit A with the circuit breaker closed The C unit in both the versions are delayed on dropoff by means of RC circuit for a total time of 350 to 800 milliseconds, to prevent a false alarm due to collage dips caused by faults in other circuits or during a normal tripping operations, when unit A is momentarily short circuited by the self-reset tripping relay contact. If the trip relay fails to reset possibly due to failure of the circuit breaker tripping mechanism, the alarm is initiated The alarm unit is designed to operate via pilot wires, if required.

Technical data Coil rating Standard voltage variants 24/48 Vdc and 110/220 Vdc. Models with specific voltage rating such as 24, 30, 48, 50, 110/125 or 220/250 volts dc are also available for ordering. Operating band 80% - 120% of rated voltage Maximum loop resistance 50 ohms for nominal alarm supply 24 to 50 V Other alarm supplies 400 ohms When rated for a 100V alarm supply the unit C will not operate at a current less than 25 milliamperes. It is therefore suit able for use with anti-corrosion negative potential blasing device. Burdens Operating time 0.35 to 0.8 sec. at 80% of rated volts (be- tween failure of trip circuit and operation of alarm contact) Thermal rating 120% of rated voltage continuous Operating indicator Hand reset operating indicator provided when required Contacts 2 Normally Open and 2 Changeover contacts available with 24/48 Vdc and 110/220 Vdc variants 3 pairs of self-reset contact one make and two break as standard with other models Insulation The relays meet the requirements of IS 3231/EC 255-5 Series C-2 KV for 1 minute DC Voltage 24 30 48/50 110/125 220/250 Maximum Watts Trip Supply 0.52 0.56 0.62 1.56 3.13 Alarm supply 0.37 0.38 0.44 1.12 2.6 Contact Ratings Make and Carry Continuous Make and Carry for 3 Sec Break AC DC 1250VA with maximum of 5A 1250W with maximum of 5A 7500VA with maximum of 30A 7500W with maximum of 30A 1250VA with maximum of 5A 100W (resistive) 50W (inductive) with maximum of 30A

Dimensions and Weights Relay Case Size Maximum overall dimension Approximate Gross Height (mm) Width (mm) Depth* (mm) weight kg. VAX 21 ½ N Hor 124 153 130 1.8 VAX 31 1 D Vert. 233 170 203 5.2 ½ N Hor 124 153 124 1.8 *Add 76 mm for maximum length of terminal studs, alternatively, 29 mm for terminal screws The approximate gross weights given above are inclusive of cartons, mounting appendages and terminal details. The relays comply fully with requirements of IS 3231 and are suitable for use in normal tropical environments. Information Required to Order 1. Type of Relay (VAX 21 or VAX 31) 2. Aux Voltage rating

ALSTOM T&D INDIA LIMITED Pallavaram Works 19/1, G.S.T. Road, Pallavaram, Chennai - 600 043 Tel: 91-44-2264 8000 Fax: 91-44-2264 0040 ALSTOM T&D Worldwide Contact Centre: http://www.alstom.com/contactcentre/ Tel.: +44 (0) 1785 250 070 www.grid.alstom.com Figure 3: Case and panel cut-out dimensions for case ½ N (all dimensions in mm) Figure 4: Case and panel cut-out dimensions for case 1D (all dimensions in mm) Alstom logo and any alternative version thereof are trademarks and service marks of Alstom. The other names mentioned, registered or not, are the property of their respective companies. The technical and other data contained in the document are provided for information only. Neither ALSTOM, its officers nor employees accept responsibility for or should be taken as making any representation or warranty (whether exp ress or implied) as to the accuracy or completeness of such data or the achievements of any projected performance criteria where these are indicated. No liability is accepted for any reliance placed upon the information contained in this brochure. Alstom reserves the right to revise or change these data at any time without further notice.