Product information: Obel-P Flow Coater

Similar documents
CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

MAJAX-2 GENERAL SPECIFICATION

LEF/MEF LEX/MEX ATEX versions

Shot blasting Machine RHBD 9/22-T

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

ROOFMASTER STEF-HT ROOF FAN

INSTRUCTION MANUAL MAGNA RAIL

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Series description: Wilo-Drain MTC

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Sample gas pumps P2.x ATEX

mono-mix Contents Complete Equipment with Scope of Supplies 3 Accessories 4-5 Spare Parts

Profile Spraying Machine, Makor Model IRIDE 206/W (Modified)

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

MegaBox Product-specific information

Installation & Technical Guide. Domestic & Commercial.

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

F a n t y p e s J K K - J K K

Quality wins through!

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Pressure control for air and water Type CS

Coating systems. Subject to change. Krautzberger GmbH /

Operating manual LPS. Humidifies and Cools. ÁLPS.ENzÈ LPS.EN

Vent-Axia Sabre Sickle Roof Fans (VSR)

APP S pumps APP S / APP S / APP S 21-38

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

RVP-R- VAV controller. In explosion-proof version

ROOFMASTER STEF-HT ROOF FAN

D10 Page. Contents. Complete Equipment with Scope of Supplies 2. Accessories 3

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

Original Spare parts. for SpriMag and aisa internal COating MaChineS and OvenS

Liquid ring vacuum pumps in compact design

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

Max. airflow m 3 /s Diam. min. Diam. max

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Spare parts list GS 640 / GS 650

LAIMET HP-400 L SCREW CHIPPER UNIT

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Liquid ring vacuum pumps

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

Liquid ring vacuum pumps with magnetic coupling

SOLSTART Instruction Manual

HIGH-POWERED VENTILATORS

APP pump instruction APP and APP 16-22

Bifurcated Case Axial Fans (BIFA)

Marking Systems. Paint Spray Systems Marking Blocks Paints & Inks

Centrifugal medium-pressure fans fitted with multi-blade

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

THE INTELIAIR TM. i2m AND i3m FUME EXTRACTION ARMS KEY FEATURES

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Side Channel Pumps CEH CEH 1202/ /7 TECHNICAL DATA. Temperature: max. 180 C Casing pressure: PN 40

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

Powerful centrifugal fans for universal use: The product ranges TEM and REM

APP S 674 pumps APP S / APP S APP S

SECTION DUST COLLECTOR

APP pump instruction APP 21-43

CONTROL UNITS VEHICLE EXHAUST GASES. Pure advantages

Thermoplastic Centrifugal pump, Type NM

ELADOS EMP IV E00 Diaphragm Pump type

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

Feed Pumps VP / VPB / VPBM

Mobile recleanable HEPA filter units for a flow of m 3 / h

ALLWEILER. Block Macerators Series ABM Designs S and I. Design I with controller and seal water unit

HDS 5/11 U. Fine-mesh water filter. Efficiently protects high-pressure pump against contamination. Easy to remove from outside.

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Spare Parts List GS 14 / GS 15 GS 14 E / GS 15 E

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Export Pricelist. Extraction rail type AS Exhaust rail, pipe connections. Extraction rail type AS Exhaust rail, Pipe Connections

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

AXIAL FANS & VANEAXIAL FANS

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Admiss. counterpressure. Admiss. pressure at pump inlet 115 S

Sample gas pumps P 2.3, P 2.3C, P 2.83, P 2.4, P 2.4C, P 2.84

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Bulk Solids Feeding. Distributor for. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC

Improving your workspace

RUJA AUTOMATION June User manual. D R PP Filter - Unit. Page 1 of 10 User manual D-R--P-Filter -Unit

Hison Axial Flow Fans

Transcription:

Product information: Obel-P Flow Coater Obel-P Automation produces a wide range of flow coaters which are shortly described in this product information. The machine described is for windows with max. dimensions up to 1700x2500 mm. The size of the machine will be adapted to the customer s requirements.

Flow Coater, type AFW - 4000. The system is user-friendly and compactly built with pump, piping, and extraction system built into the cabin. Specifications: The cabin is lacquered on the outside and coated with teflon foil on the inside for quick and easy cleaning. Bottom vessel and draining racks in stainless steel. The nozzle strings are made from stainless steel and fastened with a spring coup-ling for easy assembling/disassembling. A compressed-air driven diaphragm pump conveys the liquid internally in the system and to/from the system. An integrated extraction system prevents vapour from oozing into the product-ion room. The control panel is well-arranged and user-friendly with pushbutton activation of the valves. The control is prepared for time operation together with the conveyor. Everywhere we have used quality materials, which do not cause corrosion or discoloration even in connection with water-based products. The pump will normally be delivered with diaphragms and valves in NBRrubber. For liquids aggressive to NBR-rubber we suggest that the pump is equipped with diaphragms and valves in PTFE (teflon). Further information about the aggressivity of the liquid can be obtained at the liquid supplier in question.

Technical data: The outside dimensions of the flow coater: Length : 4,000 mm (excl. draining racks) Width : 1,000 mm Height : 3,550 mm* (excl. supporting bracket) * It is possible to lower the system by max. 500 mm below floor level so that the height above floor level is 3,050 mm. Draining racks: Length/section : 2,250 mm Width : 500 mm Dimensions of the passing zone: Height : 2,900 mm Width : 500 mm Volume of treatment liquid: Min. : 40 l Max. : 200 l Diaphragm pump: Output : 5.5-6 m³/h Air consumption : 20-25 Nm³/h Extraction system: Output : app. 1,500 m³/h Diameter of outlet pipe : 250 mm Electricity connection: Voltage : 3 x 400 V + PE Current : 3.3 A Power : 1.5 kw Frequency : 50 Hz Compressed-air connection: Pressure : 5-10 bar Pump : ½" internal pipe thread Time signal : 4 mm hose coupling Own weight : app. 1,300 kg

Operation conditions: Max. workpiece size approx. 1,700 x 2,500 mm depending on the suspension angle and the height of the draining rack. The workpieces must be suspended so that they lean approx. 20 downwards, so that there is free outflow of the surplus liquid, and so that the workpieces do not shade each other. The feeding speed through the system may not exceed 4 m/min. Nozzles and piping system must be thoroughly flushed after use. Compressed air for the diaphragm pump must be free from water vapour and oil mist. Electric Panel, Type PL Control for paint system complete. For central units, overhead conveyor and exhaust fans, drying room and vacuum room. Plate capsulated panel in tightening class IP54 for fully automatic control and super-vision of the operating and security functions of the central units. Main switch, star-delta starters, motor protection, relays, fuses, start/stop switch, terminal block, emergency stop and automatic anti-freeze of heat battery. In case of frost hazard (an incoming air temperature of approx. +12 ) the fan is stopped, and the motor-operated closing damper is closed at the same time as the heat supply is com-pletely turned on. When the frost hazard has passed over (an incoming air temperature of + 12 C), the fan is restarted, the motor damper is opened and the motor valve will be in balance again. The electric panel is prepared for zero (extra protection), but is excl. phase compensation. The panel is fitted with numbered terminal blocks for external coupling and is sup-plied fully internal coupled. Complete with variable speed control via frequency converter to the conveyor. Energy saving dampers 500 with gun support. For automatic closing of exhaustion and supply air, when the spray gun is put down.

Fan Type ALF - kw. Complete with spark proof inlet. Impeller with backward curved blades, efficiency approx. 75%. Direct driven by 1450 r.p.m. standard motor. Inlet and outlet for ductwork. L x W x H = x x mm Motor = kw, 1450 R.P.M/min. Performance = m³/h at PA The data for the fan are depending of the size of the machine. Console for Type ALF Fan. Complete in strong galvanized execution Ducting Complete. In longitudinally grooved galvanized plate sheets with clamp joints incl. Ducts in standard lengths of 1 or 2 metres. Bends in pressed execution from 80-200 and segment bends from 225. Clamps type Fb - Ebb, flanges, pipe brackets, bolts and mounting parts. From Flow-Coater and let out through the roof/wall and finished by deflector cap. For more information please contact us.. Obel-P Automation A/S, Cypresvej 16, DK 7400 Herning Telefon +45 97217800, E-mail sales@obelp-automation.dk, www.obelp-automation.dk