Low Profile J Series Power Unit with Vane Pump

Rancher Hydraulic Chute Owner s Manual.

H2000 Hydraulic Chute

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Standard Power Units Start-Up and Maintenance

CIRCLE SEAL CONTROLS

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

CIRCLE SEAL CONTROLS

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

Operating instructions Form no safety definitions

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Instruction Manual. Maximum Operating Pressure 510 bar

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

Operating Instructions - Electric Pow'r-Riser Models

Troubleshooting the Transmission Hydraulic System

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

M-1115S Series Fuel Pump

Excellence In Fluid Control Since 1975

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Hydraulic Chassis Lift System Operating and Maintenance Manual

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

OPERATION AND PARTS MANUAL

M-3025CB-AV Fuel Pump

Air / Hydraulic Pump

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

PED SERIES HYDRAULIC & MECHANICAL POWER ELECTRIC DUMP PUMPS. Operating & Maintenance Instructions Electric Dump Pumps.

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

High Lift Transmission Jack

20 Series. Simplify your pumping needs. s Adhesive Supply Servo Pump:

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

Electric Airless Sprayers Operating Instructions

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

NECO Pumping Systems

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

Vane Pumps. Single Stage Single and Double Vane Pumps. Vickers. Overhaul Manual

SINGLE ACTION FLUID PUMP

Hydraulic and Commissioning Mannual Module 2A

CAB TILT HYDRAULIC SYSTEM

Monarch D.C. Hydraulic Power Systems. Comprehensive information may be found on the page referenced below each selection category.

OPERATION AND PARTS MANUAL

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

THE TRACTOR AND/OR LOADER (IF EQUIPPED)

KLW4000D Multi-Port Power Pack

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

Dodge Cool Lube 2 for Sleevoil Pillow Blocks Part Numbers , , ,

Hydraulic Pump Troubleshooting P & BDP Series Models

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model Repair Parts Sheet SPECIFICATIONS. Stake threads lightly after assembly. Note: Pump base is not available as a service item.

PE 20 SERIES ELECTRIC POWER PUMPS

Starting up hydraulic systems

Lecture 32 MAINTENANCE OF FLUID POWER SYSTEMS

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

LIPPERTCOMPONENTS, INC. HYDRAULIC SLIDEOUT AND HYDRAULIC LANDING GEAR (HLG) SYSTEM OPERATION AND SERVICE MANUAL

WALKIE HIGH LIFT HYDRAULIC SYSTEM

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

CONTENTS. EMERGENCY PUMP USE Electric Pump...H-3 Manual Pump...H-5

Hydraulic Hand Pallet Trucks

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

DP33 Pump. 60:1, 3+3, Air-operated, Grease. General. Operation. Technical Data. Installation R2 08/15

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200}

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

END SUCTION CENTRIFUGAL PUMPS

OWNER S TECHNICAL MANUAL

Polypropylene Piston Drum Pumps

TABLE OF CONTENTS. Tow Behind Bulk Bin Brake Release Procedure... H-3. General Hydraulic Repair Procedure... H-4

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

Rev: Flow Max 115V AC Fluid Pump

PE39 Series Compact Torque Wrench Pump

HYDRAULIC STEERING MANIFOLD HM260 TABLE OF CONTENTS. 1. GENERAL INFORMATION... p TECHNICAL SPECIFICATIONS... p. 01

OPERATION AND PARTS MANUAL

Troubleshooting The Transmission Hydraulic System

SERVICE INSTRUCTIONS. Transfer Pump

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

JARVIS. Model HTC -80 Hog Toe Cutter

Cast Iron Rotary Drum Pump

ABSOLUTE EQUIPMENT PTY LTD

M16, 20, 25, 30 MLB16, 20, 25, 30 OWNERS MANUAL/PARTS LIST

Arctic Equipment Manufacturing Corporation M3551 Hydraulic Power Unit. Table of Contents

LC I LIPPERT COMPONENTS HYDRAULIC FULL WALL SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL

ABSOLUTE EQUIPMENT PTY LTD

Heavy Duty Sprayer Owners Manual Model MS-O

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

50 Gallon Skid Sprayer

Routine Compressor Maintenance

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

Transcription:

Operating Instructions & Parts Manual Grainger Part No. 36NE08 Bucher Hydraulics Part No. M-3504-0239 Please read the instructions carefully and always operate this equipment in a safe manner. Unit Description: This hydraulic power unit is designed specifically to run on DC electric power. Each power unit is a custom assembly consisting of a high performance hydraulic pump, DC motor, internal relief valve, load holding check valve and reservoir. This power unit can be coupled to suit a wide variety of hydraulic actuating devices. The pump contains hardcoated end plates for unmatched durability in demanding environments and severe duty applications. Package Contents and Handling Instructions: Before opening, please check for any shipping damage. The container will include (1) DC hydraulic power unit with breather cap for the reservoir. If components are missing, or if there is any visible damage, please contact the office in which you purchased this unit. Schematic: Content: Power unit contains: Pump / Motor / Reservoir Unit 12 VDC Motor Check Valve Externally Adjustable Relief Valve preset at Factory. Adjustable range not to exceed the Maximum Operating Pressure listed in the performance table 9/16-18, SAE #6 outlet ports Hardcoated pump ends Fixed displacement, external tooth pump Horizontal or Vertical Mounting Dual-layered mesh inlet strainer Performance: Model No. Nominal Flow Maximum Operating Pressure Motor Voltage Reservoir Capacity Control Valve 36NE08 2.5 GPM 3000 PSI 12 VDC 1.0 GALLON N/A

Dimensions: -ATTACH TO POSITIVE TERMINAL ON DC BATTERY -ATTACH TO DC POWER FROM CUSTOMER SWITCH CONNECTION (TORQUE NUT BETWEEN 50-60 IN-LBS.) -ATTACH TO DC POWER FROM CUSTOMER SWITCH. STARTS ELECTRIC MOTOR. (TORQUE NUT BETWEEN 15-20 IN-LBS.) Model No. A Length B Width C Height 36NE08 18 3/8 7 1/8 7 1/2 Mounting Information:

bh READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. : THIS INSTRUCTION MANUAL IS INTENDED FOR USE BY QUALIFIED INDIVIDUALS WITH A WORKING KNOWLEDGE OF HYDRAULIC AND ELECTRICAL PRINCIPLES. PROFESSIONAL INSTALLATION IS RECOMMENDED. Assembly All the power units are packaged fully assembled. Customer is responsible to fill the reservoir with proper level of a quality hydraulic fluid suitable for use in the intended environment. 5. Use of a filter cart to add fluid to the reservoir is highly recommended. Do not pour hydraulic fluid directly from a pail or drum as this can result in debris entering the reservoir. 6. Re-install the breather on the reservoir. Avoid dusty conditions that could clog the reservoir breather. 1. This hydraulic power unit is designed for horizontal or vertical mounting with the reservoir feet down and the reservoir breather on the top. Choose a flat, level mounting surface to bolt the reservoir feet to. See unit dimensions for reservoir base bolt pattern. The hydraulic unit is plumbed for horizontal or vertical mounting as noted above. Mounting the unit in an inclined plane or any other position will greatly reduce available usable oil in the reservoir. This can cause the hydraulic oil to foam resulting in erratic movement of hydraulic components, and pump failure. To minimize contamination problems, do not remove plastic shipping plugs from hydraulic unit until you are ready to install hoses and fittings. 2. HYDRAULIC INSTALLATION Make sure that the work area and the hydraulic components are clean and free from dirt, lint, etc. 3. Connect your hoses and fittings to the hydraulic actuator (hydraulic cylinder, hydraulic motor, or other devise) and when ready to connect the hydraulic power unit ports, remove and discard all plastic shipping plug from ports of the aluminum manifold. Do not use Teflon tape. This unit is equipped with SAE O- ring type ports. Do not over-tighten fittings. 4. Remove the reservoir breather and fill the hydraulic unit reservoir with a good quality hydraulic fluid. It is recommended that hydraulic fluids have a viscosity of 100 SUS to 350 SUS when operating between 10 F and 140 F. Electrical wiring 1. When wiring the power unit, follow all local electrical and safety codes as well as the National electrical and safety codes in your jurisdiction (i.e. NEC, ESA, etc) and all Occupational Safety and Health Act (OSHA) requirements, or similar. 2. Make certain that wire size is adequate for voltage requirements. 3. Proper grounding should be supplied to the 5/16-18 GND threaded hole. NOTE: Voltage drop increases with the length of power cord. Larger wire diameter may be required. 4. Motor nameplate voltage must be available at the motor when it is operating under load. Avoid voltage drop by using adequate wire size. 5. On start-up, ensure an open flow path for the hydraulic circuit and jog the motor to prime the pump to ensure adequate lubrication. After the fluid is moving freely, motor may be operated at full speed. Never run the system without adequate levels of hydraulic fluid in the reservoir. New installations will require additional fluid to fill the lines, cylinders etc. so check the reservoir fluid levels frequently during initial operation to ensure the fluid level does not go below the minimum level. 6. Keep all electrical lines as short as practical. 7. Never exceed the maximum operating pressure. 8. Do not over-tighten fittings, bolts, etc., as this can damage the units. 9. Provide adequate cooling for the hydraulic oil so as not to allow oil and/or component damage due to excessive temperatures. Excessively high operating temperatures will be hazardous and may cause property damage and/or personal injury.

REPLACE OR REPAIR DAMAGED OR WORN POWER CORDS IMMEDIATELY. DO NOT OPERATE UNITS WITHOUT PROPER GROUNDING. DO NOT RUN THE HYDRAULIC UNIT DRY AS THIS WILL CAUSE SEVERE PUMP DAMAGE. Prior to Operation: 1. Double check all hydraulic and electric connections. 2. Confirm that reservoir is filled with hydraulic fluid. 3. Put all equipment guards in place 4. Clear all persons from work area 5. Check for loose tools, equipment, or anything that might interfere with operation of equipment. Operation bh Do not overfill the reservoir as foaming of the oil may occur. Maintenance 1. Keep the reservoir filled to the proper level with hydraulic fluid. Use a good quality hydraulic fluid that is suitable for use in the intended environment. 2. Check the reservoir fluid level on a regular basis and use new, filtered hydraulic fluid when adding fluid. Most pump/fluid motor failures, valve malfunctions, and short unit life can be traced directly or indirectly to dirt or other foreign materials (water, chips, lint, etc.) entering or already in the hydraulic system. 3. Make a frequent inspection of hydraulic fluid and change if contaminated. 4. Regularly inspect hydraulic hoses and fittings for wear or leakage. 5. Keep the unit and surrounding area clear of dirt and foreign materials. 6. Keep electrical connections clean. 1. Start Up When initially starting unit up, be sure to jog the unit (intermittently run unit) several times. This will prime the pump and fill the hydraulic lines. Troubleshooting Chart: Symptom Possible cause(s) Corrective action Motor won t start 1. Loose connection 1. Check wiring 2. Circuit breaker tripped 2. Reset circuit breaker 3. Voltage drop 3. Use heavier gauge wire 4. Seized pump 4. Replace pump 5. Start switch 5. Replace start switch Will not pump oil (Motor runs but cylinder does not move, or moves slowly) 1. No oil in reservoir 2. Oil level low 3. Relief valve is held open 4. Suction strainer is clogged 5. Hydraulic cylinder (or motor etc.) seals are cut or worn out. 6. Reservoir breather is dirty or clogged. Pump motor unit is noisy 1. Low oil level 2. Air in system 3. Suction strainer or inlet filter is clogged Unit does not develop full pressure 1. System relief valve set too low, or leaking 2. Pump worn out 3. Air in system 4. Oil temperature is too high 1. Check oil level, refill 2. Add oil as needed 3. Flush relief valve 4. Clean suction strainer 5. Replace or repair cylinder (or motor etc.) 6. Clean reservoir breather and reinstall 1. Add oil as needed 2. Bleed air from highest fitting in system by loosening fitting very slightly and operating unit until bubbling of air stops, then tighten 3. Clean suction strainer or inlet filter 1. Check system relief valve for proper setting 2. Replace the pump 3. Bleed air from systems 4. Let oil cool below 140 F

Exploded View:

Parts List: Description Part No. 1.* P ASSY,MOD,DC,BRGS BLED RESV. 500246312171270 1.1 P ASSY,QM,MDLR,DC,BRGS BLD RSV 500216312171270 1.2 O-RING,3.75 X 4.00 X 0.13-240 500205302352 1.3 SEAL,SHAFT,HEAVY DUTY(B&M SER) 500207002159 1.4 O-RING,0.50 X 0.63 X 0.06-014 500205300120 1.5 SCREW,SHC,1/4-20 X 3.0,BLK OX 500206907818 2.* PARTS KIT,RESV,PLSTC,6.75X6.75 500205523790 2.1 RESV,PLSTC,6.75X6.75X11,V/MT 500206414185 2.2 CLAMP,HOSE,WORM GEAR,RSV,M-SER 500201707900 2.3 O-RING,3.75 X 4.00 X 0.13-240 500205302352 2.4 FILTER,SCREEN M-SERIES SUCT. 500203201134 2.5 PLUG,RESEV,BREATHER-FILLER 500205901143 3. TUBE,45 DEG,3/8 NPTF 500208321877094 4. TUBE,30 DEG,3/8 NPTF 500208322015066 5. VALV MAX.SPEC.-ROT-95/210B 200787402710 6. MOTOR,DC,12V,4.5in,1 TERM 500205008111 7.* SOL.SW.,KIT,12VDC,3P,PSEAL,GND 500248017757 7.1 SWITCH,SOL ACT MTR ST,12 VDC 500208017757 7.2 STRAP,MOTOR-SOLENOID CONNECTNG 500207813155 8. SCREW,PAN HD,TORX,10-32 X 5/16 500206917071 *KITS CONTAIN ALL SUBCOMPONENTS LISTED BELOW EACH KIT NUMBER