Using the Phoenix MultiPlus to reduce operating cost of a generator

Similar documents
Phoenix Multi Inverter/Chargers

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

QUATTRO. (+34) Skype

OFF-GRID BACK-UP & ISLAND SYSTEMS ENERGY. ANYTIME. ANYWHERE.

ENERGY. ANYTIME. ANYWHERE. AUTOMOTIVE

Marine. Energy. Anytime. Anywhere.

EnErgy. anytime. anywhere. MARINE

:34 1/15 Hub-4 / grid parallel - manual

BMS 12/200 for 12,8 Volt lithium iron phosphate batteries Especially designed for vehicles and boats

Photovoltaic Standalone Plants ECO-FRIENDLY-POWERFUL-SAFE

:43 1/13 Victron & BYD B-Box

Hub-4 / grid parallel - manual

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

ENERGY. ANYTIME. ANYWHERE. AUTOMOTIVE

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

Solar inverter AX-series

MARINE ErE. h yw n E. a ytim n y. a Erg En

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Inverter/Chargers. Off-Grid Inverters. Solar charge controllers

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

Energy Storage Systems by. Positronic. Manufacturing Pty Ltd

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Current Automation Catalogue Page 27

Save Thousands of Dollars Per Year!

SimpliPhi Power PHI Battery

AUTOMOTIVE ErE. h yw n E. a ytim n y. a Erg En

Chapter 3.1: Electrical System

EnErgy. anytime. anywhere. MARINE

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Marine. Energy. Anytime. Anywhere.

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

INVERTER/CHARGERS Off-Grid Power Solutions

SAFE AND RELIABLE POWER FOR MARINE APPLICATIONS MEMBER CERTIFIED. The World Depends on Sensors and Controls

The cement and minerals industry

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Using Inverter Input Modes for Smart Grid Management

Mass Combi Ultra 24/ (230 V)

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

Standby Inverters. Written by Graham Gillett Friday, 23 April :35 - Last Updated Sunday, 25 April :54

ABB n.v Power Quality in LV installations

LEADING BATTERY ENERGY STORAGE SOLUTIONS AVAILABLE FROM FREEDOM WON (DATA SHEETS AVAILABLE UPON REQUEST) Freedom Lite Home & Business

Phoenix Multi 12/1300/70 12/2000/120 24/1300/40 24/2500/70

OFF-GRID BACK-UP & ISLAND SYSTEMS

THE FORGOTTEN BATTERY, LEAD ACID.

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

MERU Solar Off-Grid Inverters

Automotive. Energy. Anytime. Anywhere.

POWER. Inverters.

Application. Battery. Public Grid GS HYBRID INVERTER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

OFF-GRID BACK-UP & ISLAND SYSTEMS

INCREASING THE ELECTRIC MOTORS EFFICIENCY IN INDUSTRIAL APPLICATIONS

Installation Manual for DC Injection Brake Units

White Paper. Application of Resistive/Reactive Load Banks for kva Testing

DYNAMIC BOOST TM 1 BATTERY CHARGING A New System That Delivers Both Fast Charging & Minimal Risk of Overcharge

USER S MANUAL SOLAR POWER INVERTER KW-6KW

Current Automation Catalogue

Common Bus and Line Regeneration

Automotive. Energy. Anytime. Anywhere.

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators

Power Conditioning of Microgrids and Co-Generation Systems

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

Upperlands Coffee: 4kWp PV, 5kWp Wind with 25kWh EMMA Battery Storage with 3kW of EMMA Heat Storage

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

Using OutBack Inverters for 3-Phase 480V Applications

Technical Specification SENTINEL PRO

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Power. There is no denying that motorhome owners

Why array oversizing makes financial sense

100W Basic Kit (GS-100-Basic)

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

CHOOSING THE RIGHT POWER MODULE FOR INVERTER DESIGNS. By Mark Steinmetz, Field Applications Engineer Vincotech GmbH

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Working Principle of Power Saver as per Manufacture:

Power Conversion System The Best Technology for your photovoltaic and storage system

ESS design & installation manual

Solar Inverter Manual

off-grid Solutions Security of supply Basics: Off-grid energy supply

GS-100+ Preconfigured Kits

ESS Design & installation manual

Is Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics

Fachpraktikum Elektrische Maschinen. Experiments with a 400/ 690 V Squirrel Cage Induction Machine

Standby Power Systems

Power Protection Discrete Automation & Motion South Africa

Components for your PV Solar Electric System

When should an Electric Adjustable Speed Drive be used instead of a Gas or Steam Turbine? Paul Blaiklock, Manish Verma, Stephan Bondy

2000 KW / 2500 KVA POWERED by

1/7. The series hybrid permits the internal combustion engine to operate at optimal speed for any given power requirement.

EASY ACCESS TO ENERGY EVERYWHERE

INDIA S FIRST 4 Star Rated Technology Inverter

Residential Solar Electricity in Canada

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

BLUE POWER World quality leader in independent electric power

Power Factor Correction

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Eskisehir Light Train- Correcting Capacitive

String Sizing with SkyBox

Incorporating Real Time Computing in Data Center Power Networks

Transcription:

06/12/2004 Using the Phoenix MultiPlus to reduce operating cost of a generator 1. The traditional AC generator system Per Watt ac-power, an inverter is generally more expensive than a generator. So why would one add an inverter to an ac-generator system? Apart from the obvious advantage of silent ac-power, there are other major considerations why it is attractive to add a Multi inverter/charger to a system with ac-generator: Fuel savings Cost and time savings as a result of reduced maintenance Extended generator life 24/7 availability of ac power Figure 1. shows a typical ac-power requirement schedule. In this example, there is a morning peak of 3 kw for two hours, a 3 kw peak around noon and the evening peak of 6 kw. Between morning- and noon peak and between noon- and evening peak, ac requirement is relatively low, around 500 W on average. After the evening peak, the average requirement is about 1 kw for some hours. With a 7.5 kw ac-generator as the only source of ac-power, the generator needs to run for 17 hours per day. 70% of the time the generator is loaded to less than 15% of its full capacity. Generator hours - 7.5 kw generator only 8000 7000 6000 Power [W] 5000 4000 3000 2000 1000 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time [h] Generator potential Pow er requirement Figure 1. System with 7.5 kw generator only 1

2. Adding a Victron MultiPlus to the system We now introduce a Victron Phoenix MultiPlus 24/3000/70 inverter/charger and a battery bank to the system. (see appendix for MultiPlus schematic) The inverter can supply the required acpower most of the time. During the peak ac-requirement, the generator is started (preferably automatically by the Multi and/or a battery monitor) to supply peak ac demand. At the same time, the MultiPlus will use any ac-power from the generator which is not required by the ac-loads, to re-charge the batteries. Figure 2 shows the same system now with the Victron MultiPlus added. Generator running hours can be reduced to 5 hours/day, while 12 hours of ac-consumption are enjoyed in silence. Whenever the generator is running, it is loaded up to 70% of its capacity. 7.5 kw generator with Victron Multi Inverter / Charger (without PowerControl a 10 kw generator would be needed) 8000 6000 Generator power Inverter / Charger Power requirement 4000 Power [W] 2000 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1819 20 21 22 23 24 Charge current reduces because batteries are nearly fully charged -2000-4000 Time [h] Charge current is automatically reduced in order to prevent overload of the generator, see section 3 Figure 2. System with 7.5 kw generator and Victron MultiPlus. The blue line shows the power through the Victron Multi. When the blue line is above 0, the inverter of the Multi takes power from the batteries to supply ac-power to the ac-loads. When the blue line is below 0, the charger of the Multi takes ac-power from the generator to re-charge the batteries. 2.1 The Battery The battery size needed is smaller than what may be expected. In our example a 24 V battery would be discharged to 166 Ah just before the generator is started in the morning, and to 285 Ah just before the generator is started in the evening. A 24 V / 600 Ah battery would therefore be a good choice, with ample reserve capacity. If a 48 V system is chosen, 300 Ah will be needed. The most rugged battery for the purpose is the type used in forklift trucks. 2

2.2. Fuel consumption The typical 7.5 kw generator will consume about 1.5 l/h diesel at low load and 2.3 l/h at 75% load. So the generator only configuration requires 25.5 liters diesel per day, whereas the generator with the Victron Multi requires 11.5 l/day to provide the same ac power. A savings of 5110 liters diesel per year. At Euro 0.50 per liter, this equates to a savings of about Euro 2555 per year (not counting time and money saved on re-fuelling). 2.3. Periodic maintenance Typical recommendation by the manufacturers is to change oil every 150 h of operation. For the generator-only scenario with 6205 running hours, this equates to 41 oil changes per year. When the Multi inverter / charger is added to the system, running time is reduced to 1825 hours, this equates to 12 oil changes per year. A savings of 29 oil changes per year. At a typical lube oil volume of 5 l, 145 liter of lube oil is saved each year. At Euro 5.00 per liter, this equates to a savings of Euro 725 per year (not counting time involved in performing the oil change and parts such as oil filters). 2.4. Generator life Generators based on a fixed speed diesel engine will last longer when they are run under load compared to being run at no- or low load. Some manufacturers recommend operation at a minimum of 30% load to prevent premature failure. By adding the Multi inverter/charger in our example, the load on the generator went up from less than 15% for 70% of the time, to a loading of 70%. A considerable longer generator life may be expected. 2.5. Summary Generator Only Generator with Multi Savings Running hours/day 17 h 5 h 12 h (silence) Diesel consumption/day 25.5 l/day 11.5 l/day 14 l/day Diesel consumption/yr 9307 l/yr 4197 l/yr 5110 l/yr Oil changes/yr 41 12 29 Lube oil consumption/yr 205 l/yr 60 l/yr 145 l/yr Generator loading 15% load for 70% of 70% load running hours Annual savings in fuel and lube Euro 3.280/yr oil (3x longer service life of the generator not included) Dollar savings after 5 yrs Euro 16.400 2.6. Conclusion Apart from the obvious benefit of availability of silent ac-power, the fuel savings and cut-down in maintenance are significant when a Multi inverter/charger is added to the generator system. Also, not covered in this brief, the environmental impact as a result of reduction in harmful exhaust and oil waste will be significant. Actual gain will vary per generator and actual power requirement profile. In general, the benefits will be larger when the ac-requirement profile shows a pattern of a few high peaks with significantly lower average power requirements between the peaks, which is a common profile for most ac generator systems. 3

3. Why should the inverter/charger be a Victron MultiPlus? In the previous section we saw that there are potentially huge benefits and cost savings to be made when an inverter/charger is added to a system with ac-generator. There are many inverter/chargers on the market that cost a lot less than a Victron MultiPlus. In this section we will show that, to take full advantage of the potential benefits, the inverter/charger must be a Victron MultiPlus. Apart from obvious benefits such as the clean pure sine wave output, ultra fast ac-transfer switch, marinized construction, high quality built and an organization behind the product which has been committed to R&D and customer support for over 30 years, there are five specific features of the MultiPlus that are essential in achieving cost savings when using the inverter/charger with the acgenerator. 3.1. AC input power manager Unique to the Victron MultiPlus is the ability to set a power level that the unit will try to maintain at its ac-input terminals. The MultiPlus has 2 levels of ac power management. The first level is PowerControl. PowerControl The PowerControl functionality enables the MultiPlus to automatically increase and decrease the charge rate of its charger depending on the power demand at the ac-output of the Multi. The PowerControl functionality of the input power manager is best understood by looking more closely at fig. 2. The blue line shows the power through the Victron Multi. When the blue line is above 0, the inverter of the Multi takes power from the batteries to supply ac-power to the ac-loads. When the blue line is below 0, the charger of the Multi takes ac-power from the generator to re-charge the batteries. This ac-power is an additional load of 2.2 kw for the generator. As can be concluded from fig. 1, this additional load would result in an overload of the generator between 18 hours and 19 hours, because the other ac loads do increase to 6 kw during that period (see fig. 1). Adding the 2.2 kw load of the charger would increase the load to 6 + 2.2 = 8.2 kw. This overload would stall the 7.5 kw generator. To prevent this, the input power manager of the MultiPlus will automatically reduce its charge rate in order to limit the total load on the generator to the set maximum power level, 6.5 kw in this example. If you are still reading, you are either an enthusiast or professionally involved with power systems. In that case we will let you in on one of our best-kept secrets. PowerAssist: the secret of the MultiPlus Figure 3 shows again our example power schedule with the 6 kw peak in the evening. But now the generator has been downsized to 5 kw. Choosing a smaller generator will of course reduce noise, size, weight, fuel consumption and initial investment. The 5 kw generator will however not be able to supply the peak load of 6 kw, even if the charge current of the MultiPlus is reduced to zero during that period. Now PowerAssist, the second level of ac power management is needed. With PowerAssist the MultiPlus can temporarily supplement the generator ac-power with power from the battery. In figure 3 this is visible between 18 hours and 19 hours: even though the generator is running, the MultiPlus is inverting (blue line above 0) instead of charging, thus providing the additional acpower that is required on top of the generator output. With one MultiPlus 24/3000/70 an additional 3 kw can be added to the generator output! 4

5 kw generator with Victron MultiPlus 8000 6000 generator potential MultiPlus power power requirement Power [W] 4000 2000 PowerAssist: the MultiPlus ads power to the generator output. 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24-2000 -4000 Time [h] Figure 3. System with 5 kw generator and MultiPlus inverter/charger. When the blue line (MultiPlus) is below 0, energy is put into the battery bank (charging), when the blue line is above 0, the MultiPlus is generating ac from the battery bank (inverting). Dynamic range of ac power regulation In the previous sections, we saw that the key to achieving savings by adding an inverter/charger to a generator system was the ability of the inverter/charger to dynamically control the ac power taken from the generator. With the MultiPlus, 24/3000/70 the dynamic range of ac power regulation is more than 5 kw: The first level of dynamic ac power regulation is PowerControl, which enables control of the ac power needed for battery charging between zero and a maximum power draw of about 2.3 kw. (= 70 A charge current times 30 V charge voltage at 90% efficiency) On top of that PowerAssist, the second level of dynamic ac power regulation, extends power regulation with an additional 3kW (per unit), which may be above the maximum power of the generator. This implies that using a MultiPlus is particularly useful when the ac-power requirement profile shows large variations (high peaks short in duration, low average), that require a wide dynamic range of ac-power regulation. 3.2 Unity power factor Simply said, the power factor of an ac-load is an indication of how much power needs to be supplied to the load relative to the power that the load consumes. The power consumed by the load is indicated in Watts, the power that needs to be supplied is indicated in VA. If the Power factor is PF, the following relationship exists: P W = PF x P VA. The power in VA is equal to the product of rms voltage and rms current. 5

The power factor of some battery chargers can be as low as 0.7. This means that a charger that consumes 2 kw, requires about 2.8 kva from the generator to make it work. If the generator voltage is 230 V, the generator must be able to supply 12.2 A to this charger. The generator would only need to supply 8.6 A for the same charge result if the power factor were to be 1. One cause of non-unity power factor is that load current is not in phase with the voltage. The other major cause of non-unity power factor is a load current that is not sinusoidal. A nonsinusoidal load current will cause harmonic distortion in the ac system. Harmonic distortion can cause generator windings to burn out. To cope with the negative effects of non-unity power factor and non-sinusoidal current of most chargers, generator suppliers will recommend to oversize the generator by as much as a factor of 2 (note that only the generator needs to be oversized, not the diesel engine driving it). The Victron MultiPlus inverter/charger has a unity power factor (PF = 1). A system with Multies does not require over sizing to cope with the chargers. It furthermore will not introduce harmonic distortion into the system. These are very important considerations when planning to add an inverter/charger to a generator system. 3.3 Scaling Third reason to choose a Victron Multi, is because this is the only inverter/charger on the market that allows easy scaling of the system. A single 3 kw inverter/charger will have little impact on a 40 kw generator system. Because the Victron Multi is a modular unit, systems of up to 15 kw single phase or 45 kw 3-phase can easily be built by adding more units. The total system can easily be scaled for optimum performance / savings. (see fig. 4) Figure 4: System with 5 Multies in parallel, a generator and an alternative supply. 6

Note: At the other side of the power spectrum, A MultiPlus can also be used to boost the output of small gensets like the Honda I range for example. (The I range starts at 1 kva) 3.4 External ac power management module In the examples of fig. 2 and fig. 3 generators with 7.5 kw and 5 kw output power were used. In case of larger systems (see fig. 4) with multiple paralleled Multies, it becomes unpractical to use the internal ac power management module of the Multies. For larger systems an external current measuring system has been built in the PowerManager, and soon an even more sophisticated ac power management module will become available. 3.5 Connectivity: a continuously increasing array of monitoring and control facilities Next to the Multi Control panel and VEConfigure, VE.Bus and VE.Net connectivity will soon make any requirement regarding remote control (including mobile phone and satellite) a reality. 4. Conclusion In the second section, we showed that adding an inverter charger to an ac-generator system could have huge potential benefits such as silent ac supply, fuel savings, maintenance reduction and extended generator life. In the third section we saw that to be able to achieve these potential benefits, the inverter/charger must have certain specific features that are found only on the Victron MultiPlus: automatic ac input power control, unity power factor and modularity for scaling. 7

Appendix : schematic diagram of the MultiPlus The bidirectional converter The M/M+ is built around a bidirectional converter, that operates as an inverter or as a battery charger. The converter of the M+ does more than a conventional bidirectional converter: it operates in parallel with the grid, with shore power or with a genset. It can add power to AC supply (with energy from the battery) and it will use surplus power to recharge. In most cases the M+ will also reduce the harmonic distortion of the genset output (this can be important for certain sensitive loads such as an induction cooker) A multifunctional relay This relay can a. o. be programmed to start a generator based on power demand and / or battery voltage. A RS485 port All parameters of the M/M+ are programmable. The most important parameters can be programmed with a push button code, but it is much more convenient to use the MK.1b RS485 to RS232 converter, VEConfigure software (downloadable from our website) and a PC Notebook computer. Examples of programmable parameters: - inverter DC voltage cut out - charge curve - maximum charge current - parallel operation, split phase operation and 3 phase operation - programming the multifunctional relay 8

Connector for parallel operation and 3 phase operation Up to 6 Multi s can be parallel connected to increase power to 15 kw. In 3 phase configuration up to 18 Multi s can be used to build a 45 kw inverter / charger! AC input with 16 Amp thermal breaker and safety relay The maximum AC input current of the M/M+ is 16 A. (optional 32 A).06/12/200406/12/2004 The safety relay makes sure that no dangerous AC voltage will be present on for example the shore power plug when disconnected. The Multi Control Panel (16 A or 30 A) The rotary knob on this panel is crucial: with this knob the maximum AC input current can be set, to a maximum of 16 A or 32 A. 9