Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

Similar documents
IROX 2000 IROX DIESEL

On-Line NIR Analysis for Blending

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Renewable Fuels Association One Massachusetts Ave. NW Suite 820 Washington, DC Telephone: (202) Fax: (202)

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

EXPERIMENTAL STUDY ON THE INFLUENCE OF ETHANOL AND AUTOMOTIVE GASOLINE BLENDS By

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

SCOPE OF ACCREDITATION

SPECTRO XRF Report. SPECTRO iq II

Biodiesel Analysis Utilizing Mini-Scan - Handheld Analyzer V.C. Gordon PhD, Bonanza Labs

Comprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels

Digital Copper Corrosion Measurement Vs. Visual Rating _ Incorporating New Technologies To Method Development

On-Line NIR Analysis of Crude Distillation Unit

7.09 ULTRASONIC ANALYZER

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

We re Going Global ETHANOL

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL

MEASURE. BIOFUEL PARAMETERS When and Where You Need To. Coen Duvekot Product Marketing Manager, MicroGC

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

The Advantage of Real Atmospheric Distillation using D7345 Test Method. Presented by Jonathan Cole, PAC

VERSATILITY IN PROCESS CONTROL & FUEL ANALYSIS USING ATR FLOW CELL & FT-IR. Michael Collier 19-January-2018

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

OptiFuel. solid partners proven solutions. Precision and portability in a top of the line FTIR Fuel Analyzer

OptiFuel. solid partners proven solutions. Precision and portability in a top of the line FTIR Fuel Analyzer

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

White Paper.

Exceeding Expectations

Monitoring Quick Guide 5

Determination of Phenolic Antioxidant DBPC and DBP Levels in Electrical Insulating Oil

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

ISBN SANS 342:2006 Edition 4 SOUTH AFRICAN NATIONAL STANDARD Automotive diesel fuel Published by Standards South Africa 1 dr lategan roa

New Small Spectrometer Concepts Covering the Ultraviolet to the Mid-Infrared

Advantages of Using Raman. Spectroscopy to Monitor Key. Gasoline Blending Parameters

ASTM D for Denatured Fuel Ethanol Automating Calculations and Reports with Empower 2 Software

a review of analytical methods for the quantification of aromatics in diesel fuels

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

Internal Combustion Optical Sensor (ICOS)

Corrosion in Underground Storage Tanks (USTs) Storing Ultra-Low Sulfur Diesel (ULSD):

International Journal of Advanced Engineering Technology E-ISSN

Application. Gas Chromatography June 1995

Elemental Analysis of Biofuels with SPECTRO XRF and ICP Spectrometers

ElvaX Sulfur in Oil analyzer

Emission and Combustion Characteristics of Si Engine Working Under Gasoline Blended with Ethanol Oxygenated Organic Compounds

Solution Sheet 1.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Annex no. 1 of Accreditation Certificate no. LI 333 from

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

SOUTH AFRICAN NATIONAL STANDARD

Proposal to establish a laboratory for combustion studies

CERTIFICATE OF ACCREDITATION

Bio Fuels in Western Cape Presented by N McHardy

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

2 nd ICCT Workshop on Marine Black Carbon Emissions 16/17 Sept, Utrecht. Ralf Oldenburg, Peter Lauer, MAN Diesel & Turbo

Corrosion in Underground Storage Tanks (USTs) Storing Diesel

ADU 5. Automatic Distillation Unit

Determination of Volume Correction Factors for FAME and FAME / Mineral-diesel blends

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

Corrosion in Underground Storage Tanks (USTs) Storing Diesel. Summary, Findings, and Impacts of EPA s July 2016 Research

International Journal of Advanced Engineering Technology E-ISSN

Gasoline and Diesel Blending Course

TSHR 6000 series TN/TS/TX analyzer

Biodiesel Production and Analysis

KEM SET. for Petrochemical

INFLUENCE OF DIETHYL ETHER BLEND IN SPARK IGNITION ENGINE PERFORMANCE AND EMISSIONS OPERATED WITH GASOLINE AND ETHANOL

Closed Cup Flash Point Tester

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

EFFECT OF HYDRATED AND ANHYDROUS ETHANOL-GASOLINE BLENDS ON ENGINE PERFORMANCE

Presented by Dr. CHOONG-SUB JUNG

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

VEHICLE AND ENGINE TESTING SERVICES FOR RESEARCH, DEVELOPMENT AND CERTIFICATION

lubricants analysis. complete solutions for your lab. Lubricants Analysis

Rapid Analysis Methods for Oils and Biofuels Using IR/NIR Spectroscopy

ERAVAP NEW! VAPOR PRESSURE TESTING AT ITS BEST. One Vapor Pressure Tester for All Applications:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Effects of Ethanol-Gasoline blends on Performance and Emissions of Gasoline Engines

Effects of Fuel Weathering on RVP, Distillation and Oxygen Content of Ethanol and iso-butanol Blends

Certificate of Accreditation

Certificate of Accreditation

Petro Solutions. Analytical Instruments for the Petrochemical Industry

ASTM Methods that are feasible with Metrohm instruments

UL ALTERNATIVE FUELS & STANDARDS UPDATE

Prodigy ICP Application Note: # 1039

EXPERIMENTAL INVESTIGATION OF THE EFFECT OF HYDROGEN BLENDING ON THE CONCENTRATION OF POLLUTANTS EMITTED FROM A FOUR STROKE DIESEL ENGINE

DOT Tire Quality Grading (U.S. Cars)

Bright prospects Solvents for spectroscopy Uvasol

Transcription:

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared Gulf Coast Conference Patrick Ritz PAC LP

Global Ethanol Use Consumption of fuel-grade ethanol is on the rise Produced from bio- or renewable sources Advantages of Using Ethanol as Fuel or Fuel Additive Imparts high octane in relation to its cost Its molecule is 35% oxygen Aids in engine combustion Lowers harmful emissions Alternative to petroleum-based components 2

ASTM D4806 ASTM D4806 - Standard Specification for Denatured Fuel Ethanol for Blending with Gasoline for Use as Automotive Spark-Ignition Engine Fuel Ethanol Concentration by D5501 GC Analysis Ethanol concentration determined from 93 to 97% (m/m). Proposal to Expand Scope (from 93-97% to 20-99%). Methanol concentration determined 0.1 to 0.6% (m/m). Water Concentration by ASTM E203 (volumetric Karl Fischer titration) and E1064 (coulometric KF titration). 3

GC Analysis Good resolution between ethanol and methanol Good accuracy and precision with detailed information about the denaturant composition No information about water concentration Not suitable for portable field use Not a fast analysis Trained analyst KF Analysis Good accuracy at low concentration No information about ethanol concentration Hazardous materials used for the titration Chemical exposure risk Disposal of spent titration chemicals Some instrument and sample preparation required Trained analyst 4

Alternative Near IR Portable and rugged design allows ethanol analysis in the Field Highly accurate analysis results in less than 20 seconds Fully automated, easy to use Low cost (investment, operation, maintenance) (QuickSpec ) Delivered fully calibrated for 0% to 100% Ethanol & 0.01% - 5% water 5

Portable IR Can Expand Range of Testing The atmosphere or recovery facility Carbon Dioxide Molecular Sieve Ethanol Storage Fuel Ethanol Distillation Ethanol Fermentation Denaturant 6

Users Needing Quick and Simple Analysis Ethanol Producers Process Monitoring Terminals Fuel Ethanol and Oxygenated Gasoline Verification Independent Testing Labs Government Compliance Agencies Ethanol/Gasoline End-users: Car Manufacturers Military 7

NIR Technology Detection Method: Near Infrared Spectroscopy Highly accurate Uses light to probe a denatured ethanol sample Optical Design: LED/Bandpass Filter Photometric Technique Measures absorbance at selected wavelengths 1950 nm / 1550 nm Absorbance 2 1.5 1 0.5 0 Denatured Ethanol 5 mm Cell Pathlength -0.5 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 Nanometers Ethanol 97.1 Vol.% Distinct differences between ethanol and water absorption peaks H 2 O 0.4 Vol.% 8

NIR Ethanol Calibration 9

NIR Water Calibration 10

Independent Laboratory Data Ethanol Conc. r R R xy @ 97.0 vol.% QuickSpec 0.33 0.56 0.69 D5501 0.20 0.41 11

Independent Laboratory Data Water Conc. r R R xy @ 0.50 vol.% QuickSpec 0.018 0.031 0.091 E1064 0.020 0.086 12

Independent Laboratory Data Ethanol Conc. r R R xy @ 10.0 vol.% QuickSpec 0.27 0.32 1.61 D5599 0.23 1.58 13

Product Overview Scope Ethanol Water Vol% Vol% GC D5501 NIR * @97 vol.% KF E203 KF E1064 @0.5 vol.% NIR * @0.5 vol.% Method Range 93% -97% 0% 100% >0.05% 0% - 2% 0.01% - 5.0% Repeatability 0.21% 0.33% 0.008% 0.020% 0.018% Reproducibilty 0.53 0.56% 0.027% 0.086% 0.031% *Internal RR at 95% confidence limit. 14

Summary Near IR Good accuracy and precision Correlates to standard methods Measures ethanol and water (denaturant by difference) Can be made to be portable and rugged. Used where critical decisions are made. Low cost Simple to use Quick analysis with high throughput 15

Thank you 16

17