English. Instruction and operation manual S 110. Power Meter

Similar documents
English. Instruction and operation manual S 212. Dew point sensor

English. Instruction and operation manual S 430. Pitot tube flow sensor

English. Instruction and Operation Manual S 430. Pitot Tube Flow Sensor

DALI 650mA LED Driver

650mA Phase Dimmable LED Driver

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

User Manual Rittal PMC UPS 6kVA

1000mA - 650mA Phase Dimmable LED Driver

Fuse state indicator MEg72. User manual

Technical Specificaions. kwh Energy Meter

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

PM - Projector Mount System

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Installation Manual. Integrated Prepaid Keypad Meters. For HXE34-KP Meters(CT & CTPT Connection) Hexing Electrical Co., Ltd. [2013.

HARDWARE KIT INSTALLATION GLOVES

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

FOR NEW ZEALAND. T-604 WASTE DISPOSER B. HYDRAULIC CHARACTERISTICS &TECHNICAL SPECIFICATIONS. DECLARATION OF COMPLIANCE

Operating instructions

Mod: KLD6-12/35XLAS-N

Video & Power Over Coax Kit

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

USE AND INSTALLATION HANDBOOK

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

A Member of the. Integrated Metering Technologies

Operating Instructions. International English. CCS Dust Extractor

M Series External Battery Frame. User Guide

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

System Monitoring SCHOOLMETERBOX AU

Installation manual portable distributors

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

HST-BL-2830MS & HST-BL-2830MS-USA

Digital Ammeter Installation Manual

Grant Grid-Connected Inverter For Grant Solar PV Systems. Installation & User Instructions

Installation manual wall-mounted distributor

Model G14SD Vapor Management System

OWNER'S MANUAL MYCRO 8

VELOCICALC Air Velocity Meter

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

OWNER S MANUAL Please read this manual before operating your power supply

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

Heat Meter Integrator

C3 Operating Instructions

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

Wind Power Inverter WINDY BOY 5000A/6000A

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

OC Automation Converters Series. Electronic Industries Alliance (EIA) interface converter series for serial communication devices

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

362 Clamp Meter. Users Manual

c-go 24V/6A 24V/8A 24V/12A

Owner Handbook. Nebula Blizzard v3. Snow Machine. L69500 Nebula Blizzard v3.indd 1 14/07/ :47

Ventilation Testing. Micromanometer. Alnor Model AXD610 AIRFLOW TM Model PVM610. Operation and Service Manual

EStrong-series Emergency Stop

Assembly and Maintenance Manual Type ASNU

Tina 4A Connection block

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Application Engineering Europe

Indoor Air Quality Meter

SPC Series. Digital Scale. Operation Manual

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

VOLspeed Ebike Tuning

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

IAQ-CALC TM Indoor Air Quality Meter

Assembly and Maintenance Manual Type AS

User Manual. Solar Charge Controller 3KW

Instruction Manual CORDLESS DRILL & DRIVER 18V. Model SROM 1170

DP-CALC TM Micromanometer

Phase Sequence Tester

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Tina 11A Connection block

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

RU BMS Power Supply and Battery Management System Owners Guide

User Manual Solar Charge Controller 3KW

OWNER S MANUAL MiniBoost

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

IAQ-CALC TM Indoor Air Quality Meter

HBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

GEIGER-GJ56.. For Venetian blinds and exterior blinds

MANUAL. Single charger

Technical Documentation

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Megohmmeter Test Probe

Sinewave Inverters. SWING 150VA and 300VA. User s manual

For technical questions and replacement parts, please call

i n s t r u c t i o n m a n u a l

LEAD ACID BATTERY CHARGER

Type 6213 EV, 6281 EV

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Transcription:

English Instruction and operation manual S 110 Power Meter

Dear Customer, thank you for choosing our product. The operating instructions must be read in full and carefully observed before starting up the device. The manufacturer cannot be held liable for any damage which occurs as a result of non-observance or noncompliance with this manual. Should the device be tampered with in any manner other than a procedure which is described and specified in the manual, the warranty is cancelled and the manufacturer is exempt from liability. The device is destined exclusively for the described application. SUTO offers no guarantee for the suitability for any other purpose. SUTO is also not liable for consequential damage resulting from the delivery, capability or use of this device. 2 S 110

Table of contents 1. Safety instructions...4 2. Application...6 3. Features...6 4. Technical Data...6 4.1 General...6 4.2 Electrical Data...7 4.3 Input-Signals...7 4.4 Output-Signals...7 4.5 Accuracy...7 5. Dimensional drawing...8 6. Determination of the installation point...8 7. Installation...9 7.1 Installation Requirements...9 7.2 Installation Procedure...9 7.3 Electrical connection...10 7.3.1 Connection to S 330 / 331...10 7.3.2 Connection to the current clamps (CT)...11 7.3.3 Connection to the Voltage leads...12 8. Signal outputs...12 8.1 Modbus output...12 9. Optional extra accessories...13 10. Maintenance...14 11. Disposal or waste...15 12. Warranty...15 S 110 3

1. Safety instructions 1. Safety instructions Please check if this instruction manual accords to the product type. Please observe all notes and instructions indicated in this manual. It contains essential information which have to be observed before and during installation, operation and maintenance. Therefore this instruction manual has to be read carefully by the technician as well as by the responsible user / qualified personnel. This instruction manual has to be available at the operation site of the power meter at any time. In case of any obscurities or questions, regarding this manual or the product, please contact the manufacturer. WARNING! Compressed air! Any contact with quickly escaping air or bursting parts of the compressed air system can lead to serious injuries or even death! Only use pressure tight installation material. Avoid that persons get hit escaping air or bursting parts of the instrument. The system must be pressureless during maintenance work. WARNING! Voltage used for supply! Any contact with energized parts of the product, may lead to a electrical shock which can lead to serious injuries or even death! Consider all regulations for electrical installations. The system must be disconnected from any power supply during maintenance work. Any electrical work on the system is only allowed by authorized qualified personal. 4 S 110

1. Safety instructions WARNING! Permitted operating parameters! Observe the permitted operating parameters, any operation exceeding this parameters can lead to malfunctions and may lead to damage on the instrument or the system. Do not exceed the permitted operating parameters. Make sure the product is operated in its permitted limitations. Do not exceed or undercut the permitted storage and operation temperature and pressure. The product should be maintained frequently, at least annually. General safety instructions It is not allowed to use the product in explosive areas. Please observe the national regulations before/during installation and operation. Remarks It is not allowed to disassemble the product. Always use spanner to mount the product properly. ATTENTION! Measurement values can be affected by malfunction! The product must be installed properly and frequently maintained, otherwise it may lead to wrong measurement values, which can lead to wrong results. Storage and transportation Make sure that the transportation temperature of device is between -30 C... 70 C. For transportation it is recommended to use the packaging which comes with the device. Please make sure that the storage temperature of the device is between -10 C... 50 C. Avoid direct UV and solar radiation during storage. For the storage the humidity has to be <90%, no condensation. S 110 5

2. Application 2. Application The power meter is designed to measures the actual power consumption in kw and accumulates the energy consumption in kwh of a 3-phase load. Additionally other measured parameters such as current, voltage, cos phi etc. are available as well. 3. Features Measures active and reactive power, frequency, voltage currents power factor. Accumulates active energy [kwh]. 3 phases 3-wire measurement as well as 3 phase 4- wire. Modbus / RTU output to other sensors. 4. Technical Data 4.1 General Parameters Nominal voltage range Power range Frequency range Available clamp sensors Standard unit consumption: kwh other parameters: active energy, reactive energy, active power, reactive power, voltage, current, power factor L-N: 380 VAC, L-L: 660 VAC Up to 690 kw (depending on the current clamp) 45 Hz... 65 Hz 200 A, 500 A, 1000 A Operating temperature -5 C... 55 C Housing material Protection class Dimensions Weight PC + ABS IP65 (wall casing) Hat rail version: 110 mm x 90 mm x 31mm Wall version: 190 mm x 155 mm x 85 mm Portable: 177 mm x 177 mm x 60 mm 0.8 kg (with wall casing) 6 S 110

4. Technical Data 4.2 Electrical Data Power supply 24 VDC / 0.5 W 4.3 Input-Signals Clamp sensor 0... 1 AAC 4.4 Output-Signals Modbus output See chapter 8.1 4.5 Accuracy Accuracy Voltage: 0.2 % Current: 0.5 % Clamp: class 1 Energy: class 0.5 S 110 7

5. Dimensional drawing 5. Dimensional drawing 6. Determination of the installation point It is possible to install the power meter directly into the connection box on the compressor or into the connection cabinet where the power supply for the compressor is coming from. If no hat rail mounting is available, there is also a wall mountable version of the power meter. 8 S 110

7. Installation 7. Installation Please make sure that all components listed below are included in your package. Qty Description Item No. 1 Power meter D554 0030 / D554 0033 1 Instruction manual No P / N 7.1 Installation Requirements There are three types of power meters: S 110 hat rail mountable S 110-W in wall mountable casing S 110-P Portable power meter, for this please see instruction manual S 110-P ATTENTION! Wrong measurement is possible, if the device is not installed correctly. The device is for indoor use only! At an outdoor installation, the device must be protected from solar radiation and rain. It is strongly recommend not to install S 110 permanently in wet environment as it exists usually right after a compressor outlet. 7.2 Installation Procedure Installation of the S 110 hat rail mountable The S 110 hat rail mountable is installed directly into the connection box of the compressor. For the electrical connection please see chapter 7.3 Installation of the S 110-W in wall mountable casing The S 110-W has a wall mountable casing. The housing of the S 110-W must be fixed on the wall using suitable dowels and screws. S 110 9

7. Installation 7.3 Electrical connection The portable power meter S 110 is connected to the S 330 / 331. For the electrical installation please observe the following instructions. On the left side the connecting diagram of the S 110 is shown. Please observe the instructions in the following chapter for an adequate installation. 7.3.1 Connection to S 330 / 331 S 330 / 331 S 110 S 330 / 331 S 110 Terminal Pin Signal Signal Pin Terminal Pin Signal Signal Pin A 3 + Vb + 24 V 1 B 3 + Vb + 24 V 1 2 - Vb 0 V 2 2 - Vb 0 V 2 4 + D + Data 14 4 + D + Data 14 5 - D - Data 15 5 - D - Data 15 6 GND GND 16 6 GND GND 16 10 S 110

7. Installation 7.3.2 Connection to the current clamps (CT) Please observe the following steps to connect the CT. 1. Place the CT's around the isolated conductor. If the conductor is too small, use a fastener to fix the Ct as indicated in the picture below. 2. Observe the right orientation on the Ct (current flow arrow on CT points to the consumer load side). 3. Connect the red colour wire to the (+I) terminal and the blue colour on the (-I) terminal. CT S 110 Conductor Colour Signal Pin L1 red + I a 4 blue - I a 5 L2 red + I b 6 blue - I b 7 L3 red + I c 8 blue - I c 9 S 110 11

7. Installation 7.3.3 Connection to the Voltage leads Connect the voltage leads (L1, L2, L3 and N) to the 3 phase conductors. Connect N if a 4-wire connection is required. CT S 110 Conductor Signal Pin L1 V a 13 L2 V b 12 L3 V c 11 N N 10 8. Signal outputs The S 110 has a modbus / RTU output to S 330 / 331 for this please see chapter 7.3.1 Connection to S 330 / 331. 8.1 Modbus output Mode : RTU Baud rate : 19200 Device address : 1 Framing / parity / stop bit Response time Response delay Inter-frame spacing Remarks : 8, E, 1 : 1 second : 0 ms : 7 char Modbus communication settings can be changed by the service software. 12 S 110

8. Signal outputs Index Channel description Holding register Data type No. of byte Unit Resolu tion Read/ Writer Func Code 0 Voltage L1 16 FLOAT_L 4 V 0.1 R 3 1 Current L1 17 FLOAT_L 4 A 0.1 R 3 2 Voltage L2 18 FLOAT_L 4 V 0.1 R 3 3 Current L2 19 FLOAT_L 4 A 0.1 R 3 4 Voltage L3 20 FLOAT_L 4 V 0.1 R 3 5 Current L3 21 FLOAT_L 4 A 0.1 R 3 6 Active power 7 React. power 22 FLOAT_L 4 kw 0.1 R 3 23 FLOAT_L 4 kvar 0.1 R 3 8 Power factor 24 FLOAT_L 4 0.001 R 3 9 Frequency 25 FLOAT_L 4 Hz 0.1 R 3 10 Active energy 11 React. energy 26 FLOAT_L 4 kwh 1 R 3 28 FLOAT_L 4 kvarh 1 R 3 12 Power L1 30 FLOAT_L 4 kw 0.1 R 3 13 Power L2 31 FLOAT_L 4 kw 0.1 R 3 14 Power L3 35 FLOAT_L 4 kw 0.1 R 3 Remark all numbers are in little-endian format. 9. Optional extra accessories The following extra accessories are available: Current clamp sensor, 1.8 m cable, 200 / 1 A, for consumption up to 132 kw @ 220 VAC Current clamp sensor, 1.8 m cable, 500 / 1 A, for consumption up to 330 kw @ 220 VAC Current clamp sensor, 1.8 m cable, 1000 / 1 A, for consumption up to 660 kw @ 220 VAC S 110 13

10. Maintenance To clean the service kit it is recommended to use moist cloth only. ATTENTION! 10. Maintenance Do not use isopropyl alcohol to clean the power meter! 14 S 110

11. Disposal or waste 11. Disposal or waste Electronic devices are recyclable material and do not belong in the household waste. The power meter, the accessories and its packings must be disposed according to your local statutory requirements. The dispose can also be carried by the manufacturer of the product, for this please contact the manufacturer. 12. Warranty SUTO provides a warranty for this product of 24 months covering the material and workmanship under the stated operating conditions from the date of delivery. Please report any findings immediately and within the warranty time. If faults occurring during the warranty time SUTO will repair or replace the defective unit, without charge for labour and material costs but there is a charge for other service such as transport and packing costs. Excluded from this warranty is: Damage caused by: Improper use and non-adherence to the instruction manual. Use of unsuitable accessories. External influences (e.g. damage caused by vibration, damage during transportation, excess heat or moisture). The warranty is cancelled: If the user opens the measurement instrument without a direct request written in this instruction manual. If repairs or modifications are undertaken by third parties or unauthorised persons. If the serial number has been changed, damaged or removed. Other claims, especially those for damage occurring outside the instrument are not included unless responsibility is legally binding. Warranty repairs do not extend the period of warranty. ATTENTION! Batteries have a reduced warranty time of 12 month. S 110 15

SUTO itec GmbH SUTO itec Co., Ltd. Werkstr. 2 Room 10, 6/F, Block B, Cambridge Plaza 79426 Buggingen 188 San Wan Road, Sheung Shui, N.T. Germany Hong Kong Tel: +49 (0) 7631 936889-0 Tel: +852 2328 9782 Fax: +49 (0) 7631 936889-19 Fax: +852 2671 3863 Email: sales@suto-itec.com Email: sales@suto-itec.asia Website: http://www.suto-itec.com Website: http://www.suto-itec.com All rights reserved Modifications and errors reserved. S110_im_en_2017-2 16 S 110