MINISCAV Scavenging Vacuum Pump

Similar documents
UNIVERSAL BATTERY CHARGER II

Charging Station - Instructions For Use

Power Blade Charger Users Guide

PRECISION UK Ltd DUPLEX AGSS PLANT

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

Universal Battery Charger II.

HEINE NT4 MED V

Installation Operation Maintenance Troubleshooting Version Dec/ EL / Biscayne E.L.

Operator s Manual. Pre-Clinical Blood Sampling Tool

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

Hand-held Fundus Camera (Model :HFC) Operating Manual

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

OPERATION MANUAL. Motor Handpiece System for Root Canal Enlargement

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref.

DenLite Illuminated Dental Mirror

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

Blades with the MatrixPRO Driver may result in damage to the MatrixPRO Driver and/or screwdriver blades, and should

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

1 Intended Use. 2 Precautions for handling and operation. English

58kHz AM Deactivator DB104 Instruction Manual V1.0

R06 JH 03/19/13 EN-INTL SimplyGo USER MANUAL

Technical Specification

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

VT Oil-Free Range Operators Handbook

TABLE OF CONTENTS 1. SHIPPING CARTON & CONTENTS INTRODUCTION PF SERIES MRI SPECIFICATIONS ASSEMBLY INSTRUCTIONS...

DC POWER SUPPLY ALIMENTATION C.C.

Simplicity Light Post Mount

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

LED Twister II. User manual UK Version 1.0

INSTALLATION INSTRUCTIONS

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Resuscitation System Model 100

Clinical Electric OPERATION MANUAL

Gutta Percha Heating System

R0 JH 11/3/11. SimplyGo

DENTAL UNIT AND CHAIR OPERATING INSTRUCTIONS

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

Operating Instructions. International English. CCS Dust Extractor

Instructions for Use USA. Computer Assisted Local Analgesia

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

The Powermatic User Guide Test Sieve Shaker

IEC 62133:2012 (2nd Edition) Understanding IEC Safety Requirements for Rechargeable Cells & Batteries used in Portable Devices

OPERATION MANUAL HARVEST ROYAL

OPERATION MANUAL HARVEST CAVALIER

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

2 PORT MOTORISED VALVE (28 mm)

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

Indoor Linear 50W Driver SI-CU WW

User Manual. Patient Programmer Recharger for Deep Brain Stimulation. Beijing PINS Medical Co., Ltd. MODEL R801. Beijing PINS Medical Co., Ltd.

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

INSTRUCTIONS FOR USE. Operation and Maintenance manual. Light Industrial Compressor. Hi-Tech Diagnostics Service

Preparing the Site. Information About the Site Requirements CHAPTER

Instructions For Use VATEA. Endodontic Irrigation Device

C B. Operating up to 5000m altitude 5 year product warranty Models

VANGUARD A EZ INSTALL OPERATOR S MANUAL

The device Vulcan has the function of rotating electric engines.

MatrixPRO Driver Instructions for Use

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

3 PORT MOTORISED VALVE (22 mm)

Operating Instructions For The X-Seal Manual Thermal Sealer

KEPCO Will Point You In The Right Direction!

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

Mangar Archimedes Instruction & Safety Manual

LED OPERATORY LIGHT Instructions For Use

MIDAS REX ELECTRIC BONE MILL BM110 & BM120

Language specific user manuals are available on

3. Operating instructions: Minor 200

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

Technical Information Manual

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INSTRUCTIONS IMPORTANT

Model Number Structure

Declaration of Conformity

ELORA BATTERY INTERFACE. Owner s Manual

M Series Condensate Recovery Unit

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Owner s Manual Ultra DBI TM Model: 9400

freedom through lightweight solutions

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Solid State Relays contactor with Integrated Fuse Type RGC1F

1200W INVERTER GENERATOR

c-go 24V/6A 24V/8A 24V/12A

Heavy Duty Series (HDS) Installation and user guide

DRAFT COPY, NOT FOR DISTRIBUTION

Transcription:

MINISCAV Scavenging Vacuum Pump UK & European Model User Manual

WARNINGS To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth Do not cover the MINISCAV or block the ventilation openings on the top and underside of the case Ensure that there is sufficient space around the MINISCAV to promote adequate cooling of the device. Do not install or operate the MINISCAV in an unventilated enclosed compartment Ensure that the exhaust transfer hose is securely attached to the MINISCAV and to the downstream exhaust ducting. A loud noise will be heard if the exhaust hose becomes disconnected Do not block either the inlet or outlet of the MINISCAV Ensure that connecting hoses are not kinked or obstructed and are free of leaks Do not permit the MINISCAV vacuum inlet to entrain liquid or solids The MINISCAV should be placed outside of the patient's reach Do not allow liquids to enter the case openings Do not poke any object through any opening in the case Do not use the MINISCAV in an environment with an ambient oxygen concentration in excess of 25% Do not use the MINISCAV in the presence of inflammable anaesthetic agents Do not use the MINISCAV with volatile anaesthetic agents Do not attempt to modify or alter the MINISCAV Do not drop the MINISCAV or otherwise subject it to mechanical stress or impact The MINISCAV is "MR Unsafe" it must not be introduced into an MRI environment About this manual Information for the use of the MINISCAV may be found on pages 2 to 4 of this manual. Installation guidance is provided on page 5. For users of the Porter Vacuum Control Block, additional guidance is given on page 7. Technical specifications for the MINISCAV are on page 8. Please read the relevant sections of this manual before installing or using the MINISCAV 1

Product Description The MINISCAV is intended to assist in providing protection from occupational exposure to nitrous oxide, during clinical procedures employing administration of oxygen and nitrous oxide mixtures to obtain analgesia and/or minimal sedation. The MINISCAV is an enclosed unit comprising a dual diaphragm vacuum pump and other components necessary for its operation (Fig 1). The exhaust outlet of the unit must be connected to an exhaust line vented to atmosphere outside of the building (Fig 2). The vacuum inlet of the unit is typically connected to the breathing circuit or, in some cases, to an interface block mounted on the mixer/flowmeter. For specific information, refer to the instructions for use provided with your patient circuit and/or mixer/flowmeter. Indications for Use Fig 1 MINISCAV scavenging vacuum pump The MINISCAV is intended for use with standard N ² O/ O ² mixer/flowmeter delivery systems as used for analgesia in dental and oral surgery, obstetrics, trauma management and other minor surgery. It has been tested with systems from Porter (MDM and MXR, Digital MDM), Accutron (Ultra PC and Digital Ultra), and McKesson (MC1/2). It is not intended for use with General Anaesthesia equipment, or as a general substitute for an AGSS installation. The MINISCAV provides a flow rate of 42 lpm ±3 lpm into a fixed vacuum of 90 ±10 mmhg; this is appropriate for scavenging of nitrous oxide from active double nasal hood breathing systems (e.g. Porter Brown, Accutron Clearview) without further restriction of vacuum flow rate. When used with these or with similar dental-type nasal hood active scavenging circuits, any control valves in the vacuum line should be opened fully. Where scavenging is required with directly-coupled anaesthesia type breathing circuits, it is necessary to use an additional vacuum receiver which also provides for entrainment of room air to make up the difference between the scavenging output of the circuit and the flow rate of the MINISCAV However, the MINISCAV may not be compatible with such devices designed specifically for use with AGSS installations. The MINISCAV should not be used with a Porter AVS (Automatic Vacuum Switch) or any similar device which cuts off vacuum by means of valve closure. 2

WALL Exhaust outlet Vacuum Inlet Internal exhaust connector Side view Power Cable Exhaust outside Angle down Power Switch Exhaust transfer hose Fig 2 System view of basic MINISCAV installation Operation Connect the MINISCAV to an earthed socket outlet supplying power in accordance with the requirements stated on the rating plate. The vacuum inlet connection is on the front of the MINISCAV. When using a Porter Brown circuit with Vacuum Control Block (not supplied), insert the 'VAC' spout into the vacuum inlet (the opposite 'MASK' spout will not fit) and connect the vacuum hose from the breathing circuit to the 'MASK' spout (Fig 3). Ensure that the OFF/ON valve is open (i.e. in the 'ON' position), and fully open the variable control valve (actuator in vertical position). For other types of breathing circuit, insert the vacuum connector or adaptor into the vacuum inlet and fully open any vacuum control valves. The symbols 'O' and 'I' on the green front panel switch indicate' off' and 'on' respectively. The switch is illuminated when power is supplied to the motor. After the completion of the clinical procedure, the MINISCAV should be switched off. Pre-use check Prior to use, check that all hose connections are complete and secure, and that tubes are not kinked, twisted or otherwise obstructed. The presence of vacuum at the inlet may be confirmed by momentarily occluding the inlet with finger or thumb. When the MINISCAV is running, the front panel switch will be illuminated, and a quiet humming sound will be heard from the pump. You may also hear slight air motion sounds at ambient air entrainment points in the mask or breathing circuit. Fig 3 Porter vacuum control block in vacuum inlet (not supplied) An abnormally loud sound from the MINISCAV or its exhaust line usually indicates that there is a leak from a damaged or severed exhaust connection: this should be checked and remedied before proceeding. 3

If a vacuum cannot be detected at the patient circuit, check that the MINISCAV is running and that connecting hoses are correctly fitted and not kinked or obstructed. When using Porter Brown or similar double nasal hood masks, check that the flapper valve diaphragm (white on Porter Brown autoclavable liners) is present and functioning correctly; and that the liner (inner hood) is positively and securely engaged with the outer hood at both sides. For further guidance on use of the Porter Brown vacuum control block please see Page 7. Thermal cut-out The MINISCAV incorporates thermal cut-out protection which operates in the event of overtemperature conditions. If the switch is illuminated and the motor is not running, it is possible that the thermal cut-out has operated. The cut-out will reset automatically when the motor has cooled. Switch off the MINISCAV to prevent inadvertent restarting; the cut-out should reset within 20-30 minutes. If the thermal cut-out operates repeatedly, check that there is adequate ventilation around the MINISCAV and that it is not affected by external heat sources. In the event of continued trouble, contact RA Medical Services, or your local supplier, for advice or servicing. Cleaning Disconnect the power lead from the MINISCAV. Clean the external surfaces of the MINISCAV with a soft cloth moistened with a mild soap or dilute detergent solution. Do not use proprietary wet disinfectant wipes or a cloth that is soaking wet. Do not use aggressive cleaning agents. Do not allow moisture to enter the unit. If required, the external surfaces may be buffed with a dry soft cloth. It is not necessary to clean the exhaust transfer hose, as this is downstream of the patient. However, if required, this may be cold sterilised. Maintenance and Service Replace the exhaust transfer hose if there is any suspicion of wear, holes or tears. With the exception of fuses, the MINISCAV is not user serviceable. If service is required, contact RA Medical Services or your local supplier. If fuses require replacement, they must be replaced only with fuses of the same rating, as specified on the rating plate. If fuses blow repeatedly, contact R A Medical Services or your local supplier, to arrange servicing. To provide assurance of continued safety and performance, it is recommended that the MINISCAV is serviced by the manufacturer, or its appointed territorial service agent, at two-yearly intervals. Contact R A Medical Services or your local supplier for details of available servicing options. 4

Installation Guidance Site Planning An earthed mains socket outlet is required within 1600mm of the planned location for the MINISCAV. The MINISCAV should be sited within approximately 2000mm of the operating position, e.g. the head end of a dental chair in the recumbent position, but should not be installed within possible reach of the patient. A solid and non resonant level platform structure is required to support the unit. The MINISCAV must rest on its own resilient feet and the body of the case should not be in contact any other structure. Failure to observe this may result in a greater level of noise and vibration when the unit is operating. If the MINISCAV is to be installed in an enclosed compartment, it must be adequately ventilated. If an exterior wall is available adjacent to the desired installation position, it may be drilled to accept the wall vent assembly. The MINISCAV will then connect directly to the wall vent using the supplied exhaust transfer hose. The standard length hose is 1000mm, but other lengths may be specified at time of order. Care must be taken in selecting a position for the wall vent that is not in proximity with opening windows, doors, ventilation grilles or any other points of potential ingress. In some cases it may be necessary to prevent the opening of windows, either by physical means or by managerial edict. It is recommended that there be a clearance of 3000mm between the exhaust terminal and any potential ingress point. A similar clearance distance should be allowed between the exhaust terminal and any combustion flue terminal. Be aware that nitrous oxide is denser than air. Avoid discharging the exhaust into any enclosed light well, dry moat or similar space with limited through air currents. Effluent should not be permitted to discharge into drains or underground service chambers. If there is no convenient exterior wall adjacent to the desired position, it will be necessary to extend an internal exhaust pipeline to a suitable exit position. Such lines may be formed of flexible hose, rigid tube and connecting fittings, or a smooth bore pliable tube that may be conformed to gradual bends. When considering the course of pipework, avoid sharp bends and convolutions, keep the number of connectors to a minimum and minimise the use of upward-flow vertical sections. The recommended maximum total length for the exhaust line is 15m, when using 15mm O.D. tube and standard fittings. It is often possible to use longer exhaust lines, but such installations are subject to special design considerations and the possible use of non-standard components. The advice of R A Medical Services, or your local supplier, should be sought in these cases. Exhaust lines from multiple units should not be connected into a manifold: each unit requires a separate pipeline with its own exhaust terminal. Installing the MINISCAV Prior to installing the MINISCAV, unpack and check the contents of the package. It may be advisable to retain packaging materials for future service requirements. At the selected location, a 15mm or 16mm hole should be drilled to accept the vent assembly. The vent tube may be trimmed to length using a hacksaw or pipe cutter, but a minimum 8mm gap should be allowed between the wall and elbow connectors on both sides. It is advisable to seal the tube into the wall using a mastic type sealing compound or gap-filling adhesive compound. Be sure to tighten the nut sections of the elbow connectors after these are fitted onto the tube. Ensure that the elbow connector with stainless steel fauna screen is fitted externally, with screen to atmosphere and facing downwards. Once the exhaust vent assembly and any internal exhaust pipeline has been installed, the MINISCAV may be placed in its operating position and the exhaust outlet connected to the exhaust pipeline via the supplied transfer hose. Ensure that the transfer hose connectors are securely retained. 5

Electromagnetic Compatibility The MINISCAV is intended for use in the electromagnetic environment specified in the tables below. The user of this equipment should ensure that is used in such an environment. Electromagnetic Emissions Emissions Compliance Electromagnetic environment according to RF emissions (CISPR 11) Group 1 The MINISCAV does not use or generate RF energy. Operation is unlikely to cause any interference in nearby electronic equipment CISPR Emissions Classification Harmonic emissions (IEC 61000-3-2) Class B Class A The MINISCAV is suitable for use in all types of establishment, including residential buildings and others directly connected to the public low voltage distribution network Voltage fluctuations / flicker (IEC 61000-3-3) Complies The device operated normally and without detriment throughout all of the tests described in the table below. Electromagnetic Immunity Immunity against IEC 60601-1-2 test level Electromagnetic environment electrostatic discharge, ESD (IEC 61000-4-2) contact discharge: 6 kv air discharge: 8 kv The MINISCAV contains no ESD sensitive components and no special precautions against ESD are necessary electrical fast transients and bursts (IEC 61000-4-4) surges on AC mains lines (IEC 61000-4-5) power supply lines: 2 kv common mode: 2 kv differential mode: 1 kv Mains power quality should be that of a typical commercial or hospital environment power frequency magnetic field 50/60 Hz (IEC 61000-4-8) 3 A/m Equipment which emits high levels of power line magnetic fields (inexcess of 3A/m) should be kept at a distance to reduce the likelihood of interference voltage dips or short interruptions on AC mains input lines (IEC 61000-4-11) dip >95%, 0.5 cycles dip 60%, 5 cycles dip 30%, 25 cycles dip >95%, 5 seconds If continued operation is required during supply interruptions, the user should provide an uninterruptible power source conducted RF (IEC 61000-4-6) radiated RF (IEC 61000-4-3) 150 khz to 80 MHz 3 Vrms outside ISM bands* 80MHz 2.5 GHz 3 V/m Recommended separation distance (d metres) between device and RF source: d = 1.2P up to 800 MHz, d = 2.4P 800 MHz to 2.5 GHz, where P = transmitter output power in watts *The ISM (industrial, scientific and medical) bands between 150 khz and 80 MHz are: 6.765 MHz 6.795 MHz, 13.553 MHz 13.567 MHz, 26.957 MHz 27.283 MHz and 40.66 MHz 40.70 MHz 6

Porter Vacuum Control Block Additional user guidance for use of the Porter Vacuum Control Block with the MINISCAV The Porter Vacuum Control Block (VCB) is supplied as standard equipment with the Porter Double Mask Scavenger Breathing System (Porter Brown System). The VCB includes two valves which are necessary for control purposes when used with some forms of vacuum source. When used with the MINISCAV, both valves should be open fully at all times. Do not use the ON/OFF valve to turn off the vacuum: always use the power switch. The correct positions of the valve controls may be identified from Fig A below. Figs B and C show incorrect positions of the OFF/ON valve. The vacuum limiting valve is fully open when the actuator is in the vertical position, see also Fig D. Fig A valve in ON position Fig B valve in OFF position Fig C valve in mid position The vacuum hose (connecting to the breathing circuit) is fitted to the upper "MASK" spout and the entire assembly is fitted into the MINISCAV vacuum inlet by means of the VAC spout (see Fig D). These are also identified by the markings on rear of the block. You should note also that with some Porter vacuum control blocks, the black ball does not rise to the green zone within the indicator tube. In most cases, this does not mean that the MINISCAV is not functioning correctly. Connection to breathing circuit Note actuator in vertical position As the MINISCAV delivers a fixed vacuum that is optimum for scavenging, it is possible to dispense with the vacuum control block and use a simple male-male connector instead (Fig E). This enables the vacuum hose to be connected directly to the MINISCAV vacuum inlet. Note that this does not provide visual indication of vacuum. Fig D inserted in Miniscav vacuum inlet Fig E a simple connector may be used as an alternative to the VCB 7

Specifications Vacuum Pump: Flow Rate: Vacuum: Power Supply: Dual diaphragm type: fixed flow rate, fixed vacuum; synchronous motor 42 ±3 lpm 90 ±10 mmhg 230V ±10% 50Hz Power Consumption: 75W (cosθ = 0.75) Fuse Rating: Protection Class: Ingress Protection: Dimensions: Weight: T 1A HRC 250V 5x20mm Class I (protective earthing) IP2X; not protected against ingress of liquids or particulate matter Width 140mm, Length 415mm, Height 275mm 9.25kg Complies with BS EN 60601-1:2006 (IEC 60601-1:2005) Environmental Conditions (Operating) Temperature: 5 to 40 ºC Relative Humidity: Altitude: 5% to 95% non-condensing -350m to 3000m Supplied Accessories Power lead: 2m, with IEC 60320 C13 appliance coupler and plug appropriate to the territory to which the MINISCAV is supplied If a BS 1363 (IS 401) fused 13A plug is used (UK and Ireland), it should be fitted with a 5A fuse Exhaust transfer hose: Vent assembly: 1m, with male 22mm couplers. Other lengths available to order 480mm rigid 15mm O.D. tube. Longer lengths available to order; internal elbow connector with female 22mm coupler (for transfer hose); external elbow connector with mesh fauna screen 8

Manufactured and Distributed by: R A MEDICAL SERVICES LTD Holmes House, Skipton Road, Steeton West Yorkshire BD20 6SD U.K. Tel: 01535 652 444 Email: info@ramedical.com WEB: ramedical.com Issue: Rev B/3.1 10/17 RA Medical