Single-inlet centrifugal fans

Similar documents
High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

KV sileo 100 M. Circular duct fans. Circular duct fans

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

Circular Duct Fan prioair

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Max. airflow m 3 /s Diam. min. Diam. max

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

CK, LPK, LPKB. Duct fans with circular connection.

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE CENTRIFUGAL DUCT FANS VT Series

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Short casing. Long casing (L version) Commercial premises

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-line rectangular fans. Technical Catalogue

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

supplied in Form (B) configuration. Airflow over Impeller- Motor.

AC Commercial Fans Edition. ErP ready

BATHROOM EXTRACT FANS DECOR-100 Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Medium Pressure Centrifugal Fans

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Centrifugal medium-pressure fans fitted with multi-blade

TD-ECOWATT AND DECOR-ECOWATT Series

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

VORTICENT C E RANGE Centrifugal fans

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Wall mounted fan

Sabre Plate Mounted Sickle Fans (VSP)

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

VENTS ТТ. Series. In-line mixed-flow fans in plastic casing with the air capacity up to 2350 m 3 /h. FANS FOR ROUND DUCTS

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Powerful centrifugal fans for universal use: The product ranges TEM and REM

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Axial Flow Fans. Issue 6.

Performance. Sound Levels. Impellers. Motors. Accessories

KSOM Control exhaust valve

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

CONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage

Plate mounted axial flow fans HXBR / HXTR Series

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

Axial fans. What s more, non-stock models are normally available within two weeks.

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

MegaBox Product-specific information

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

T: +44 (0) F: +44 (0) E:

Centrifugal fan with highly efficient EC drive motor

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

CONTROL UNITS VEHICLE EXHAUST GASES. Pure advantages

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes

NEW Slimpak EC Box Fan (SLPT EC)

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

VSA. Roof fans. Dachventilatoren. Roof fans

MTF. Technical features

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

CGT Series Adjustable Pitch Fans

Transcription:

CE 200-280 4-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CE fans are easy to install. Fans in this series have impellers with forward-curved blades and external rotor motors. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating, the fans have integral thermal contacts with external leads for connection to a motor protection device. CE fans are electrically connected via a junction box. CE 200-4 CE 225-4 CE 250-4 CE 280-4 Voltage/Frequency V/50 Hz 230 230 230 230 Phase ~ 1 1 1 1 Power W 230 509 836 1267 Current A 1,00 2,45 3,75 5,55 Maximum air flow m 3 /s (m 3 /h) 0,302 (1085) 0,489 (1760) 0,693 (2495) 0,805 (2895) R.p.m. min -1 1202 1300 1183 1340 Max. temp. of transported air C 50 70 70 70 Max. temp. of transported air * C 50 70 70 70 Sound pressure level at 3 m *** db(a) 51 61 55 60 Weight kg 8,6 13 16,6 27,3 Insulation class, motor F F F F Enclosure class, motor IP 44 IP 54 IP 54 IP 54 Capacitor μf 6 8 14 30 Motor protection S-ET 10 S-ET 10 S-ET 10 S-ET 10 Speed control, five-step Transformer RTRE 1,5 RTRE 3 RTRE 5 RTRE 7 Speed control, five-step high/low Transformer REU 1,5 ** REU 3 ** REU 5 ** REU 7 ** Speed control, stepless Thyristor REE 2 ** REE 4 ** REE 4 ** - Wiring diagram p. 11-17 5 6 6 6 * when speed-controlled ** + S-ET 10 *** According to 20 m 2 Sabine A B C D E F G H J K øl CE 200-4 404 250 26 26 4 132 183 332 187 164 186 CE 225-4 445 280 25 25 6 147 198 369 211 180 234 CE 250-4 492 315 26 26 8 167 218 412 239 198 261 CE 280-4 547 357 26 26 23 182 233 455 257 221 293 276

USE p. 489 ISE p. 489 RB p. 478 VK p. 476 CE 200-4: Min. static back pressure 70 Pa CE 200-4 L wa Inlet db(a) 68 51 52 60 60 62 63 60 56 L wa Outlet db(a) 69 44 45 57 63 65 61 59 55 L wa Surrounding db(a) 58 47 43 40 51 55 47 44 38 Measuring point: q v = 0,19 m 3 /s, P s = 222 Pa CE 225-4 L wa Inlet db(a) 75 46 50 63 66 70 69 68 64 L wa Outlet db(a) 75 46 51 63 66 70 68 67 64 L wa Surrounding db(a) 68 54 49 52 60 65 61 57 52 Measuring point: q v = 0,27 m 3 /s, P s = 272 Pa CE 250-4 L wa Inlet db(a) 73 51 58 63 62 68 68 65 61 L wa Outlet db(a) 76 49 53 63 68 72 69 68 63 L wa Surrounding db(a) 62 45 50 58 50 55 53 49 49 Measuring point: q v = 0,34 m 3 /s, P s = 332 Pa CE 280-4 L wa Inlet db(a) 81 55 65 67 68 75 77 72 67 L wa Outlet db(a) 82 54 63 67 74 78 76 73 68 L wa Surrounding db(a) 67 49 55 59 54 63 59 54 47 Measuring point: q v = 0,46 m 3 /s, P s = 386 Pa RSK p. 474 VBR p. 483 FFR p. 470 LDR p. 478 S-ET p. 464 RTRE p. 454 REU p. 454 REE p. 455 277

CT 200-280 4-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CT fans are easy to install. Fans in this series have impellers with forward-curved blades and external rotor motors. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating, the fans have integral thermal contacts with external leads for connection to a motor protection device. CT 200 fans are electrically connected via a junction box. CT 225-450 fans are connected directly to the motor. CT 200-4 CT 225-4 CT 250-4 CT 280-4 Voltage/Frequency V/50 Hz 400 400 400 400 Phase ~ 3 3 3 3 Power W 310 500 788 1333 Current A 0,55 0,89 1,4 2,35 Maximum air flow m 3 /s (m 3 /h) 0,39 (1410) 0,53 (1925) 0,68 (2560) 0,91 (3265) R.p.m. min -1 1304 1319 1266 1307 Max. temp. of transported air C 61 70 60 60 Max. temp. of transported air when speed-controlled C 61 55 60 60 Sound pressure level at 3 m * db(a) 44 53 60 59 Weight kg 8,5 11 14 22,5 Insulation class, motor B F F F Enclosure class, motor IP 44 IP 54 IP 54 IP 54 Motor protection STDT 16 STDT 16 STDT 16 STDT 16 Speed control, five-step Transformer RTRD 2 RTRD 2 RTRD 2 RTRD 4 Speed control, five-step high/low Transformer RTRDU 2 RTRDU 2 RTRDU 2 RTRDU 4 Wiring diagram p. 11-17 7 8 8 8 * According to 20 m 2 Sabine A B C D E F G H J K øl CT 200-4 404 250 26 26 4 132 183 332 187 164 186 CT 225-4 445 280 25 25 6 147 198 369 211 180 234 CT 250-4 492 315 26 26 8 167 218 412 239 198 261 CT 280-4 547 357 26 26 23 182 233 455 257 221 293 278

USE p. 489 ISE p. 489 RB p. 478 VK p. 476 CT 280-4 Min static back pressure: 80 Pa RSK p. 474 CT 200-4 L wa Inlet db(a) 67 44 50 62 56 60 60 57 52 L wa Outlet db(a) 69 44 46 59 62 65 62 60 55 L wa Surrounding db(a) 51 37 31 44 43 45 45 41 33 Measuring point: q v = 0,18 m 3 /s, P s = 254 Pa CT 250-4 L wa Inlet db(a) 75 51 57 62 63 71 70 68 64 L wa Outlet db(a) 77 50 52 63 68 74 70 69 64 L wa Surrounding db(a) 67 53 43 47 56 64 61 56 50 Measuring point: q v = 0,42 m 3 /s, P s = 319 Pa VBR p. 483 CT 225-4 L wa Inlet db(a) 75 65 64 71 63 67 67 65 61 L wa Outlet db(a) 77 63 59 69 69 72 68 66 63 L wa Surrounding db(a) 59 44 40 47 49 53 54 51 53 Measuring point: q v = 0,29 m 3 /s, P s = 263 Pa CT 280-4 L wa Inlet db(a) 79 55 62 66 67 74 75 70 66 L wa Outlet db(a) 81 54 58 66 72 77 74 72 67 L wa Surrounding db(a) 66 49 42 52 53 62 61 57 53 Measuring point: q v = 0,4 m 3 /s, P s = 445 Pa FFR p. 470 LDR p. 478 FGR p. 469 CWK p. 475 LDC p. 469 STDT p. 465 RTRDU/RTRD p. 455 279

CT 225-315 6-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CT fans are easy to install. Fans in this series have impellers with forward-curved blades and external rotor motors. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating, the fans have integral thermal contacts with external leads for connection to a motor protection device. CT 225-450 fans are electrically connected directly to the motor. CT 225-6 CT 250-6 CT 280-6 CT 315-6 Voltage/Frequency V/50 Hz 400 400 400 400 Phase ~ 3 3 3 3 Power W 198 297 407 843 Current A 0,42 0,62 0,86 1,69 Maximum air flow m 3 /s (m 3 /h) 0,39 (1390) 0,50 (1800) 0,59 (2115) 0,98 (3530) R.p.m. min -1 857 832 825 782 Max. temp. of transported air C 70 55 60 55 Max. temp. of transported air when speed-controlled C 70 55 60 55 Sound pressure level at 3 m * db(a) 44 51 45 54 Weight kg 11 13 16 23 Insulation class, motor F F F F Enclosure class, motor IP 54 IP 54 IP 54 IP 54 Motor protection STDT 16 STDT 16 STDT 16 STDT 16 Speed control, five-step Transformer RTRD 2 RTRD 2 RTRD 2 RTRD 2 Speed control, five-step high/low Transformer RTRDU 2 RTRDU 2 RTRDU 2 RTRDU 2 Wiring diagram p. 11-17 8 8 8 8 * According to 20 m 2 Sabine A B C D E F G H J K øl CT 225-6 445 280 25 25 40 147 198 369 211 180 234 CT 250-6 492 315 26 26 42 167 218 412 239 198 261 CT 280-6 547 357 26 26 46 182 233 455 257 221 293 CT 315-6 615 400 26 26 58 203 254 517 298 247 326 280

USE p. 489 ISE p. 489 RB p. 478 VK p. 476 CT 280-6 Min static back pressure: 80 Pa RSK p. 474 CT 225-6 L wa Inlet db(a) 62 38 45 55 54 55 56 53 43 L wa Outlet db(a) 64 39 39 53 59 57 56 54 46 L wa Surrounding db(a) 51 34 35 44 47 44 43 41 39 Measuring point: q v = 0,19 m 3 /s, P s = 125 Pa CT 280-6 L wa Inlet db(a) 67 44 51 56 59 62 60 58 51 L wa Outlet db(a) 70 42 46 56 66 64 61 60 52 L wa Surrounding db(a) 52 41 31 40 44 48 45 40 31 Measuring point: q v = 0,34 m 3 /s, P s = 205 Pa VBR p. 483 CT 250-6 L wa Inlet db(a) 64 41 46 54 55 58 58 55 47 L wa Outlet db(a) 67 41 41 54 62 60 59 58 49 L wa Surrounding db(a) 58 46 33 42 50 53 53 47 35 Measuring point: q v = 0,29 m 3 /s, P s = 143 Pa CT 315-6 L wa Inlet db(a) 71 49 57 59 63 66 64 63 56 L wa Outlet db(a) 72 47 52 60 68 65 64 64 55 L wa Surrounding db(a) 62 38 37 48 57 57 53 50 41 Measuring point: q v = 0,48 m 3 /s, P s = 274 Pa FFR p. 470 LDR p. 478 CWK p. 475 FGR p. 469 VKK p. 476 STDT p. 465 RTRDU/RTRD p. 455 281

CT 315-400 4-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CT fans are easy to install. Fans in this series have impellers with forward-curved blades and external rotor motors. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating, the fans have integral thermal contacts with external leads for connection to a motor protection device. CT 225-450 fans are electrically connected directly to the motor. CT 315-4 CT 355-4 CT 400-4 Voltage/Frequency V/50 Hz 400 400 400 Phase ~ 3 3 3 Power W 2446 3716 4984 Current A 4,1 6,16 8,1 Maximum air flow m 3 /s (m 3 /h) 1,24 (4464) 1,72 (6192) 2,01 (7225) R.p.m. min -1 1227 1291 1312 Max. temp. of transported air C 60 70 70 Max. temp. of transported air when speed-controlled C 60 70 70 Sound pressure level at 3 m * db(a) 64 63 70 Weight kg 29 45 58 Insulation class, motor F F F Enclosure class, motor IP 54 IP 54 IP 54 Motor protection STDT 16 STDT 16 STDT 16 Speed control, five-step Transformer RTRD 7 RTRD 7 RTRD 14 Speed control, five-step high/low Transformer RTRDU 7 RTRDU 7 - Wiring diagram p. 11-17 8 8 8 * According to 20 m 2 Sabine CT A B C D E F G H J K øl 315-4 615 400 26 26 58 203 254 517 298 247 326 355-4 689 450 26 26 70 227 278 574 325 287 367 400-4 768 500 26 26 72 252 304 643 365 310 413 282

USE p. 489 ISE p. 489 RB p. 478 VK p. 476 CT 315-4 Min. static back pressure CT 315-4 150 Pa CT 355-4 400 Pa CT 400-4 625 Pa L wa Inlet db(a) 81 59 68 66 68 76 76 74 69 L wa Outlet db(a) 83 56 64 74 74 78 76 75 71 L wa Surrounding db(a) 72 51 49 55 61 68 66 62 55 Measuring point: q v = 0,62 m 3 /s, P s = 593 Pa CT 355-4 L wa Inlet db(a) 84 60 71 68 73 81 79 75 71 L wa Outlet db(a) 88 57 69 73 79 84 81 79 73 L wa Surrounding db(a) 70 44 51 54 56 68 62 54 48 Measuring point: q v = 0,92 m 3 /s, P s = 756 Pa CT 400-4 L wa Inlet db(a) 90 60 72 76 81 87 84 80 76 L wa Outlet db(a) 88 63 73 71 76 84 82 77 74 L wa Surrounding db(a) 77 46 52 61 67 75 69 60 54 Measuring point: q v = 1,16 m 3 /s, P s = 974 Pa RSK p. 474 VBR p. 483 FFR p. 470 LDR p. 478 CWK p. 475 FGR p. 469 VKK p. 476 STDT p. 465 RTRDU/RTRD p. 455 283

CT 355-450 6-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CT fans are easy to install. Fans in this series have impellers with forward-curved blades and external rotor motors. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating, the fans have integral thermal contacts with external leads for connection to a motor protection device. CT 225-450 fans are electrically connected directly to the motor. CT 355-6 CT 400-6 CT 450-6 Voltage/Frequency V/50 Hz 400 400 400 Phase ~ 3 3 3 Power W 1538 2624 3821 Current A 2,88 4,84 6,80 Maximum air flow m 3 /s (m 3 /h) 1,45 (5200) 2,07 (7455) 2,56 (9220) R.p.m. min -1 818 843 842 Max. temp. of transported air C 70 70 59 Max. temp. of transported air when speed-controlled C 70 70 59 Sound pressure level at 3 m * db(a) 56 58 60 Weight kg 32 51 62 Insulation class, motor F F F Enclosure class, motor IP 54 IP 54 IP 54 Motor protection STDT 16 STDT 16 STDT 16 Speed control, five-step Transformer RTRD 4 RTRD 7 RTRD 7 Speed control, five-step high/low Transformer RTRDU 4 RTRDU 7 RTRDU 7 Wiring diagram p. 11-17 8 8 8 * According to 20 m 2 Sabine A B C D E F G H J K øl CT 355-6 689 450 26 26 53 227 278 574 325 287 367 CT 400-6 768 500 26 26 72 252 304 643 365 310 413 CT 450-6 859 560 26 26 76 283 335 721 412 348 463 284

USE p. 489 RB p. 478 VK p. 476 RSK p. 474 CT 450-6: Min static back pressure 200 Pa VBR p. 483 CT 355-6 L wa Inlet db(a) 75 52 59 60 67 70 69 66 62 L wa Outlet db(a) 79 63 63 67 74 74 71 70 64 L wa Surrounding db(a) 63 39 42 49 58 59 56 50 45 Measuring point: q v = 0,69 m 3 /s, P s = 355 Pa CT 400-6 L wa Inlet db(a) 79 56 63 62 75 73 72 69 65 L wa Outlet db(a) 81 51 60 67 76 75 74 72 66 L wa Surrounding db(a) 65 40 43 48 60 60 58 49 42 Measuring point: q v = 1 m 3 /s, P s = 442 Pa FFR p. 470 LDR p. 478 LDC p. 469 CT 450-6 L wa Inlet db(a) 81 60 66 64 77 75 74 70 67 L wa Outlet db(a) 84 55 64 70 80 79 78 74 69 L wa Surrounding db(a) 67 39 49 51 64 63 59 48 45 Measuring point: q v = 1,35 m 3 /s, P s = 593 Pa STDT p. 465 RTRDU/RTRD p. 455 285

CKS 355-400 Swing-out Speed-controllable Integral thermal contacts Can be mounted in any position Swing-out cover for easy cleaning and servicing. Mainte n ance-free and reliable. CKS fans are easy to install. Fans in this series have impellers with backward-curved blades and external rotor motors. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating, the fans have integral thermal contacts with external leads for connection to a motor protection device. CKS 355-1 355-3 400-1 400-3 450-3 500-3 560-3 Voltage/Frequency V/50 Hz 230 400 230 400 400 400 400 Phase ~ 1 3 1 3 3 3 3 Power W 410 353 611 687 1048 1726 2801 Current A 1,96 0,73 2,77 1,60 1,88 3,34 4,86 Maximum air flow m 3 /s (m 3 /h) 0,87 (3125) 0,85 (3075) 1,17 (4210) 1,27 (4570) 1,74 (6270) 2,32 (8365)3,00 (10720) R.p.m. min -1 1356 1380 1314 1404 1333 1393 1360 Max. temp. of transported air C 70 70 70 70 70 66 70 Max. temp. of transported air* C 70 70 70 70 67 62 70 Sound pressure level at 3 m *** db(a) 54 50 56 48 60 65 68 Weight kg 11 25 33 33 43 62 78 Insulation class, motor F F F F F F F Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 Capacitor μf 8-14 - - - - Motor protection S-ET 10 STDT 16 S-ET 10 STDT 16 STDT 16 STDT 16 STDT 16 Speed control, five-step RTRE 3 RTRD 2 RTRE 3 RTRD 2 RTRD 4 RTRD 4 RTRD 7 Speed control, five-step high/low REU 3** RTRDU 2 REU 3** RTRDU 2 RTRDU 4 RTRDU 4 RTRDU 7 Wiring diagram p. 11-17 6 8 6 8 8 8 8 *when speed-controlled ** + S-ET 10 *** According to 20 m 2 Sabine A B C D E F G H J K øl CKS 355 135 342 283 243 193 590 530 668 196 250 329 CKS 400 148 383 317 266 216 658 530 748 219 283 370 CKS 450 160 432 355 294 244 734 650 837 247 312 415 CKS 500 180 482 393 317 267 810 650 926 270 343 469 CKS 560 197 542 440 342 292 900 650 1033 295 380 515 286

USE p. 489 ISE p. 489 SG p. 476 VK p. 476 CKS 355-1 L wa Inlet db(a) 71 45 60 65 65 64 61 55 52 L wa Outlet db(a) 72 46 58 66 66 66 63 54 49 L wa Surrounding db(a) 61 32 46 58 52 54 50 42 33 Measuring point: q v = 0.399 m 3 /s, 375 Pa CKS 400-3 L wa Inlet db(a) 71 41 60 65 66 62 60 52 42 L wa Outlet db(a) 77 48 61 72 72 71 67 59 52 L wa Surrounding db(a) 55 15 37 50 50 49 46 30 12 Measuring point: q v = 0.552 m 3 /s, 491 Pa FFR p. 470 CKS 355-3 L wa Inlet db(a) 69 44 58 63 64 62 60 58 55 L wa Outlet db(a) 73 44 57 68 67 66 63 54 45 L wa Surrounding db(a) 57 25 41 53 48 51 48 41 33 Measuring point: q v = 0.435 m 3 /s, 345 Pa CKS 450-3 L wa Inlet db(a) 72 42 62 65 67 65 64 56 46 L wa Outlet db(a) 79 51 64 72 74 73 69 62 57 L wa Surrounding db(a) 67 28 48 64 60 59 56 44 33 Measuring point: q v = 0.798 m 3 /s, 548 Pa LDC p. 469 CKS 400-1 L wa Inlet db(a) 72 49 63 66 67 65 64 58 54 L wa Outlet db(a) 76 45 65 71 71 69 65 60 58 L wa Surrounding db(a) 63 38 47 59 55 56 54 42 37 Measuring point: q v = 0.511 m 3 /s, 438 Pa S-ET p. 464 CKS 500-3 L wa Inlet db(a) 82 55 69 74 78 74 73 66 58 L wa Outlet db(a) 87 56 68 81 83 81 76 72 61 L wa Surrounding db(a) 72 33 56 61 68 67 63 51 41 Measuring point: q v = 1.25 m 3 /s, 672 Pa CKS 560-3 L wa Inlet db(a) 86 61 72 80 81 78 77 71 63 L wa Outlet db(a) 89 65 72 83 83 84 79 72 63 L wa Surrounding db(a) 75 37 58 71 67 69 65 56 48 Measuring point: q v = 1.76 m 3 /s, 761 Pa STDT p. 465 REU p. 454 RTRDU/RTRD p. 455 287

Bathroom fans BF, CBF BF axial fan for bathrooms CBF centrifugal fan for bathrooms, toilets and store rooms Both types can be installed on the wall or the ceiling BF Accessory BVK CBF The BF/CBF units are extraction fans manufactured from ABS plastic. These fans, except with timer, can be connected either through the light switch, so that they start when the light is turned on, or to a separate switch. The CBF has a spring-loaded back draft damper. There are three models: standard model (S), a model with timer (T) and a model with timer and humidity sensor (TH). A time delay of between 1 and 20 minutes can be set on the timer after removing the unit s front cover. The humidity sensor can be set to a value between 40 and 95% relative humidity. The BF fan has an adjustment knob that is easily accessible at the bottom of the fan. To adjust the humidity sensor on the CBF fan, the front cover should be removed first. BF 100 BF 120 BF 150 CBF 100 Voltage/Frequency V/50 Hz 230 230 230 230 Phase ~ 1 1 1 1 Power W 15 15 30,8 29,1 Current A 0,09 0,09 0,19 0,19 R.p.m. min -1 2453 2107 2253 2403 Sound pressure level at 3 m * db(a) 45 48 54 52 Maximum air flow l/s (m 3 /h) 19 (68) 23 (83) 64 (230) 29 (104) Enclosure class IP 44 IP 44 IP 44 IP 44 Accessories: Back draught damper BDS 100 BDS 120 BDS 150 - Length 51 54 57 - * According to 20 m 2 Sabine 288

Bathroom fans BF 100 BF 120 BF 100-150 BF 150 BF 100 BF 120 BF 150 A 163 182 203 øb 98 118 150 C 60 40 81 CBF 100 CBF 100L BVK BVK 100 BVK 120 BVK 150 E 140 160 180 ød 100 125 150 289

IF 150 Bathroom fans IF IF in-line axial fan Suitable for bathrooms, toilets and shower rooms The IF series are in-line extractor fans designed for the safe ventilation of bathrooms, toilets and shower rooms. Manufactured from high impact ABS thermoplastics. The series comprises of a fan unit only and is suitable for boosting a BF fan where a long run of ducting is used. The IF fans have single-phase induction motors with pre-oiled bearings. Fan curves: same as equivalent BF fan, see page xxx. IF 100 IF 120 IF 150 Voltage/Frequency V/50 Hz 230 230 230 Phase ~ 1 1 1 Power W 14 25 25 Maximum air flow m 3 /h 87 130 240 Maximum pressure Pa 20 35 50 R.p.m min -1 2432 2000 2400 Sound pressure level at 3 m * db(a) 44 34 46 Enclosure class IP 44 IP 44 IP 44 Accessories: Back draught damper BDS 100 BDS 120 BDS 150 Length 51 54 57 * According to 20 m 2 Sabine IF 120 IF 100 IF 120 IF 150 øa 100 118 150 B 90 99 110 IF 100 290

Plastic fans PRF 125-180 PRF fans have been developed especially for the exhaust of aggressive media. PRF is the right fan when corrosive gases, contaminated air or other aggressive components are part of the exhaust air. Typical applications are medical facilities, the food-, electrical or chemical industry. Explosion proof versions are possible on request. The sintered casing from PE is absolutely waterproof and offers a variety of applications with its connectors from ø125-250 mm. The casing can be easily adjusted through turning it (Standard position is LG270, see picture). To protect motors from overheating the PRF fans have integral thermal contacts (speed-controllable) or integral thermistors (PTC) (one-step) with external leads for connection to a motor protection device. Temperature of transported air from -15 C to +70 C Single-flow impellers from PP with effective blade geometry The powder painted pedestal is manufactured of galvanised steel Position of casing can be easily adapted Perfect fitting accessories: connectors, dampers, splinter protection PRF 125D2 160D2 160D4 160E4 180D2 180D4 180E4 Voltage/Frequency V/50 Hz 400 400 400 230 400 400 230 Phase ~ 3 3 3 1 3 3 1 Power at shaft P2 W 250 750 160 140 1100 160 140 Current A 0,58 1,79 0,57 1,11 2,6 0,57 1,11 Air flow m 3 /s (m 3 /h) 0,197 (709) 0,46 (1670) 0,215 (775) 0,215 (775) 0,63 (2287) 0,32 (1152) 0,32 (1152) R.p.m. min -1 2806 2869 1350 1330 2700 1360 1365 Max. temp. of transported air C 70 70 70 70 70 70 70 when speed-controlled C 70 70 70 70 70 70 70 Sound pressure level at 1 m db(a) 59 67 46 46 69 49 49 Weight kg 9 13 14 14 19 14 14 Insulation class, motor F F F F F F F Enclosure class, motor IP 55 IP 55 IP 54 IP 54 IP 55 IP 54 IP 54 Capacitor μf - - - 6 - - 6 Motor protection - - - S-ET 10 - STDT 16 S-ET 10 Speed control, five step Transformer - - - RTRE 1,5 - RTRD 2 RTRE 1,5 Speed control, five step high/low Transformer - - - REU 1,5 * - RTRDU 2 REU 1,5 * Wiring diagram p. 11-17 13b 13b 13b 21 13b 17 21 * + S-ET 10 L E C PRF A C ød E H L N P Q R 125D2 140 40 125 150 250 195 200 100 140 235 160D2 183 40 160 180 310 210 255 100 140 290 160D4/E4 183 40 160 180 310 190 255 100 140 290 180D2 208 40 180 190 350 230 277 120 190 320 180D4/E4 208 40 180 190 350 190 277 120 190 320 D A H R N P Q D 291

Plastic fans PRF 125D2 PRF 160D2 PRF 125D2 L wa Inlet db(a) 70 47 45 64 64 65 61 54 48 L wa Outlet db(a) 73 48 53 67 69 66 61 58 48 L wa Surrounding db(a) 66 48 25 52 59 64 55 48 39 Measuring point: q v = 261 m 3 /h, P s = 589 Pa PRF 160D2 L wa Inlet db(a) 80 73 57 76 75 69 64 53 45 L wa Outlet db(a) 84 75 63 80 80 72 69 61 52 L wa Surrounding db(a) 72 56 29 68 68 62 59 46 37 Measuring point: q v = 739 m 3 /h, P s = 877 Pa RTRE p. 454 PRF 160E4 REU p. 454 S-ET p. 464 PRF 160D4 L wa Inlet db(a) 67 63 62 58 57 53 49 41 33 L wa Outlet db(a) 67 55 59 64 62 56 51 43 34 L wa Surrounding db(a) 53 32 40 43 48 47 45 35 31 Measuring point: q v = 376 m 3 /h, P s = 195 Pa PRF 160E4 L wa Inlet db(a) 67 63 62 58 57 53 49 41 33 L wa Outlet db(a) 67 55 59 64 62 56 51 43 34 L wa Surrounding db(a) 53 32 40 43 48 47 45 35 31 Measuring point: q v = 376 m 3 /h, P s = 195 Pa S-DT2 p. 463 REV p. 463 292

Plastic fans PRF 180D4 PRF 180D2 L wa Inlet db(a) 90 73 87 82 82 78 74 68 61 L wa Outlet db(a) 93 74 90 87 86 80 78 69 61 L wa Surrounding db(a) 76 52 54 65 74 69 66 57 54 Measuring point: q v = 1000 m 3 /h, P s = 720 Pa PRF 180D4 L wa Inlet db(a) 70 53 67 62 62 58 54 48 41 L wa Outlet db(a) 73 54 70 67 66 60 58 49 41 L wa Surrounding db(a) 56 32 34 45 54 49 46 37 34 Measuring point: q v = 612 m 3 /h, P s = 221 Pa RTRE p. 454 PRF 180E4 REU p. 454 S-ET p. 464 PRF 180E4 L wa Inlet db(a) 70 53 67 62 62 58 54 48 41 L wa Outlet db(a) 73 54 70 67 66 60 58 49 41 L wa Surrounding db(a) 56 32 34 45 54 49 46 37 34 Measuring point: q v = 612 m 3 /h, P s = 221 Pa S-DT2 p. 463 REV p. 463 293

Plastic fans PRF 200-250 PRF fans have been developed especially for the exhaust of aggressive media. PRF is the right fan when corrosive gases, contaminated air or other aggressive components are part of the exhaust air. Typical applications are medical facilities, the food-, electrical or chemical industry. Explosion proof versions are possible on request. The sintered casing from PE is absolutely waterproof and offers a variety of applications with its connectors from ø125-250 mm. The casing can be easily adjusted through turning it (Standard position is LG270, see picture). To protect motors from overheating the PRF fans have integral thermal contacts (speed-controllable) or integral thermistors (PTC) (one-step) with external leads for connection to a motor protection device. Temperature of transported air from -15 C to +70 C Single-flow impellers from PP with effective blade geometry The powder painted pedestal is manufactured of galvanised steel Position of casing can be easily adapted Perfect fitting accessories: connectors, dampers, splinter protection PRF 200D2 200D4 250D2 250D4 Voltage/Frequency V/50 Hz 400 400 400 400 Phase ~ 3 3 3 3 Power at shaft P2 W 1500 250 4000 750 Current A 3,26 0,95 7,77 2,5 Air flow m 3 /s (m 3 /h) 0,93 (3373) 0,47 (1692) 1,8 (6560) 0,91 (3280) R.p.m. min -1 2784 1413 2880 1374 Max. temp. of transported air C 70 70 70 70 when speed controlled C 70 70 70 70 Sound pressure level at 1 m db(a) 74 59 86 66 Weight kg 34 34 49 46 Insulation class, motor F F F F Enclosure class, motor IP 55 IP 54 IP 55 IP 54 Motor protection STDT 16 STDT 16 - STDT 16 Speed control, five-step Transformer - RTRD 2 - RTRD 4 Speed control, five-step high/low Transformer - RTRDU 2 - RTRDU 4 Wiring diagram p. 11-17 13b 17 13b 17 L E C PRF A C ød E H L N P Q R 200D2 240 40 200 200 410 245 320 150 230 355 200D4 240 40 200 200 410 210 320 150 230 355 250D2 290 40 250 240 495 340 330 170 250 370 250D4 290 40 250 240 495 230 330 170 250 370 D A H R N P Q D 294

Plastic fans PRF 200D2 PRF 200D4 PRF 200D2 L wa Inlet db(a) 87 64 67 74 82 82 80 74 67 L wa Outlet db(a) 89 67 74 78 84 84 83 74 65 L wa Surrounding db(a) 81 77 47 63 74 75 72 63 55 Measuring point: q v = 1241 m 3 /h, P s = 1576 Pa PRF 200D4 L wa Inlet db(a) 77 59 66 70 72 70 65 58 51 L wa Outlet db(a) 74 58 69 69 68 63 61 51 42 L wa Surrounding db(a) 67 32 38 54 65 58 54 48 43 Measuring point: q v = 1377 m 3 /h, P s = 171 Pa RTRE p. 454 PRF 250D4 REU p. 454 S-ET p. 464 PRF 250D2 L wa Inlet db(a) 100 78 85 86 95 95 92 85 76 L wa Outlet db(a) 101 86 87 91 95 96 95 84 75 L wa Surrounding db(a) 93 67 71 80 86 91 85 78 64 Measuring point: q v = 3000 m 3 /h, P s = 1600 Pa PRF 250D4 L wa Inlet db(a) 80 58 65 66 75 75 72 65 56 L wa Outlet db(a) 81 66 67 71 75 76 75 64 55 L wa Surrounding db(a) 73 47 51 60 66 71 65 58 44 Measuring point: q v = 1460 m 3 /h, P s = 548 Pa S-DT2 p. 463 REV p. 463 295