Control Solutions Biofloor

Similar documents
HERZ Electronic room thermostat analog and digital

Control solutions Biofloor

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

STRA-24 for chilled beams

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AXS 215S: Continuous actuator for unit valves, with stroke indicator

LK Control v.3 & LK Control v.3 - RA

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

SAX Electronic Valve Actuator

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Power consumption In operation At rest For wire sizing

Safety Control HR1S-AC. Safety Relay HR1S-AC

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

Temperature Controller (Heat Pumps)

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

SE8300 Series Installation Guide 24 Vac Low Voltage

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

BUILDING AUTOMATION CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE Intelligent solutions for intelligent people.

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Condensation monitor

Electronic Circuit Breaker ESS20-0..

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Overview of types. Technical data

SetPoint 501 and 501s Controllers Installation and Operation Manual

Panelboards & Motor Starters

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

AKM 105, 115: Rotary actuator for ball valve

SAVE THESE INSTRUCTIONS

c-go 24V/6A 24V/8A 24V/12A

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Electrical Actuators

Electromotoric actuators

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

EGQ 212: Duct transducer, CO 2 and temperature

Chain lubrication unit WS-E

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

RC-DO. Room controllers with display and manual forced ventilation function

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

2-position electric actuators with Ball valves VBZ ½...11/4

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

Power consumption In operation At rest For wire sizing

SITESTAR ELECTRONICS CABINET DESCRIPTION

Premounted Midi Shunts

Actuators for air dampers and control valves of oil burners

SG-B1 SERIES / SG-A1 SERIES

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

SECTION MOTOR CONTROL

SetPoint 150 Controller Installation Manual

MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

Combined Ventilation Controller RVWS-T-224HA

A44 W0...W2: Motorised actuator

SAV Electronic Valve Actuator

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Power consumption In operation At rest For wire sizing

Actuators for air dampers and control valves of oil burners

A419ABG-3C Electronic Temperature Control

VC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Sheet Steel Emergency Light Fitting Series 6018

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

lindab comfort Regula Control er

G72x Series Direct Spark Ignition Controls

Technical data. Safety notes

AVM 105, 115: Valve actuator

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

/ LOSSNAY / LGH-RS2-E2

ZonePlus Z322 zone valve Installation and commissioning instructions

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Power Electronics. Motor brake relay GA 9031 ministop

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Power consumption In operation At rest For wire sizing. Non-operating temperature

Solenoid coil for control in potentially explosive areas Type BZ

Solenoid coil Types BB, BE, BF, BG, and BN

LK Manifold Shunt VS2

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

Transfer switch OTEC and OTECSE open transition

Transcription:

MCF234 Distributor for Wired Control System COMAP proposes a new control system for heating and cooling underfloor. Consisting of a 6 or 10- channels controller (MCF234), analogic (TAF234) or electronic (TEF234) room thermostats and thermal actuators (TE24) to control the various circuits, it enables optimum temperature control, by area or room. Item code Description Application Distribution of the power supply, the positioning signals and a shared time schedule for room devices (analogic or with display) and thermal actuators. Description For easy wiring of up to 6 or 10 zones in a panel heating system For transferring switching signals from the unitary controllers for heating or heating/cooling Individual forwarding of time commands or night set-back to the appropriate actuators; max. two time channels With pump and boiler control Pump logic with adjustable follow-on time for actuating the circulation pump Integrated valve protection function Input for temperature limiter or dew point monitor LED status indicator Pump control direction switching for NC/NO actuators For connecting up to 18 actuators Cable guidance, standard-compliant cord grip and screwless terminal connections Easy, intuitive wiring and installation C412009001 C412010001 C412011001 C412012001 C412013001 Controller Heat 230-6 channels Controller Heat/Cool 10 channels Controller Heat/Cool 10 channels Control Heat/Cool+option 10 channels Control Heat/Cool+option 10 channels 00817_2016-01_ENG 1

Range Distributor 2 zones 6 channels 10 channels 24/ C412009001 C412010001 C412011001 C412012001 C412013001 Basic thermostats - heat C411012001 - heat C411013001 Electronic thermostats heat C411014001 heat/cool C411016001 heat C411015001 heat/cool C411017001 Actuators For 9000TP/K9000TP Manifolds - C430042001 - C430041001 For V9004 Manifolds - C430044001 - C430043001 Accessories Sensor Transformer C412014001 External temperature sensor - C422015001 Cable type NTC sensor 1,5m C422016001 Cable type NTC sensor 3m C422017001 Dew point monitor on housing C422018001 Dew point monitor with cable C422019001 Functions 6 channels 24/ C412009001 10 channels - C412010001 - C412011001 10 channels - C412012001 - C412013001 Heating Cooling - Pump control - Pump control with delay - - Heating/cooling input - Pump and valve protection - - LED indicator - - TB or rh% input - Boiler control output - - NC/NO switching - - 00817_2016-01_ENG 2

Technical features Housing material, ABS plastic, black RAL9005 Cover: transparent grey plastic Fitting: Mounted on wall or DIN rail Connection terminals: Automatic, max. 1.5 mm 2 Power supply +/- 20% - 50 60 Hz +/-10% - 50 60 Hz Distributor fuse T 2 A T 4 A H Circuits/zones 6 ou 10 Time channels/reduction 2 Admissible ambient temperature 0...50 C Admissible storage temperature -20 70 C Admissible ambient humidity < 80 % HR Outputs Number of actuators Pump connection Boiler connection 6-channel: Max. 15 10-channel: Max 18. 6 (2) A max. 6 (2) A max. Inputs Decrease Heating/cooling TB or dew point Potential-free contact input Potential-free contact input Potential-free NC contact Connection terminals Power cable Terminals with spring technology for 0.2 to 1.5 mm² vertical cable entry Solid: NYM-J/NYM-O (max. 5 1.5 mm²) Flexible: H03V2V2H2-F / H05V2V2H2-F Type of protection IP 20 (EN 60529) Protection class II (EN 60730) III (EN 60730) 00817_2016-01_ENG 3

Distributor 6 channels 10 channels 24/ C412009001 C412010001 C412011001 C412012001 C412013001 Weight 482g 515g 515g 550g 534g Accessories Transformer 230/24 V, 42 VA Item code: C412014001 Description of operation Main functions The electric distributor (MCF234) is installed in the cabinet of the underfloor heating manifold and serves as a distributor for the power supply, for the individual positioning signals and for a shared time schedule (max. 2 channels). The distributor forwards the room controller command and the decrease signal to the thermal actuators. Terminals A and B serve as time channels for decreasing the set temperature. The time schedule can be defined using an external timer. The corresponding connection can be used to reduce all the other zones depending on the time. A pump can be activated directly via the two terminals provided. The pump logic is used to activate the pump according to requirements. The pump starts operating as soon as an actuator is active. So if none of the connected actuators are activated (i.e., the valves are closed), the pump is switched off. With some version, the pump logic can be set with a time delay. The factory setting for the lead time is fixed at 2 minutes. The factory setting for the follow-on time is 2 minutes and can be adjusted to 7 minutes, 12 minutes or 17 minutes using the DIP switch. A temperature limiter can be connected via the two TB terminals. Pump function of the Heat/Cool models The thermal actuators are switched off when the water temperature is too high or the dew point has been reached. The pump continues running. 00817_2016-01_ENG 4

Additional functions of the Heat/Cool + options models Dew point monitoring The pump (and the water circuit), the boiler and the thermal actuators are switched off immediately when the water temperature is too high or the dew point has been reached. A dew point monitor (with only) can be connected as an alternative to the temperature limiter or in addition to it. It uses condensation in cooling mode. As soon as the dew point is reached, the pump and the thermal actuators are switched off. If no device is connected to these terminals, the existing jumper must be left where it is, as otherwise the pump logic will not work and the outputs of the thermal actuators will be interrupted. If a temperature limiter and a dew point monitor are required, they must be connected in series. Pump protection function If the pump is not actuated by a heating or cooling requirement for 14 days, it is automatically activated for 10 minutes. The boiler relay remains inactive. Boiler relay output If there is a heat requirement from a connected room thermostat on one of the 10 channels, the boiler relay is activated with a delay of 2 minutes (factory setting). As soon as there is no longer a heat requirement on any of the 10 channels, the boiler relay is switched off again after a follow-on delay of 2 minutes. The boiler relay is always activated at the same time as the pump relay and uses the DIP switch settings of 2, 7, 12 or 17 minutes. The boiler relay is not activated during the pump protection function. Valve protection function The valve protection function is always active and is activated for 10 minutes every 14 days. The actuator is activated and opens the valve. This is a static function that takes place independently of the actual activation of the actuators. The pump relay and the boiler relay are not activated during the valve protection function. Switching the pump control direction to normally open You can use the coding switch to change the pump control direction from normally closed (NC) to normally open (NO). To ensure this function, room thermostats with direction switching must be used, e.g. TEF 234. In this case, the valves on the hydraulic distributor are open when the thermal actuator is not energized. To ensure that the pump logic functions, jumpers must be attached between L/L1 and the thermal actuator output (symbol ) on the channels that are not used. 00817_2016-01_ENG 5

LED indicator LED Power LED (green) Red LED C/O LED (blue) Pump/boiler LED (green) LED (green) Description When the power is connected, the LED lights up continuously. When the valve protection function is active, the Power LED slowly flashes once per second. The channel LEDs light up continuously. If the control distributor is energized and the fuse is defective or not installed, the red LED lights up continuously. When the CO input is closed, the LED lights up continuously. The LED is activated at the same time as the pump/boiler relay. When the TB/%H input is open (temperature limit/dew point reached), the pump LED flashes rapidly 8 times per second. As soon as the output is active, the corresponding channel LED lights up continuously. Number of connection terminals for thermal actuators 1 2 3 4 5 6 7 8 9 10 C412009001 5 0 2 0 1 1 0 2 0 4 C412010001 C412011001 C412012001 C412013001 5 2 2 1 1 1 1 2 2 4 5 2 2 1 1 1 1 2 2 4 Depending on the version, there are up to 21 connection terminals. It is possible to connect from 15 up to a maximum of 18 thermal actuators. Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product documents must also be adhered to. Modifying or converting the product is not admissible. Engineering and fitting notes Outdoor installation: The devices are not designed for use outdoors, and are only intended for dry, enclosed indoor rooms. Cord grip: Feed the cable through the cord grip into the housing. Make sure the cable jacket is not damaged. 00817_2016-01_ENG 6

Standards and directives The electrical distributor is tested to standards the necessary EU standards are taken into account. EMC Directive 2004/108/EC EN 61000-6-1/EN 61000-6-2 EN 61000-6-3/ EN 61000-6-4 EMC Directive 2006/95/EC EN 60730-1 Disposal The local, currently valid laws must be observed when disposing of the device. Connection diagram 6 s Heat only - C412009001 TAF234 TEF234 10 s Heat/Cool - C412010001 and C412011001 TAF234 TEF234 00817_2016-01_ENG 7

10 s Heat/Cool + Options - C412012001 and C412013001 TAF234 TEF234 Coding switch Dimensional drawing MCF 234 Distributor Manufacturer reserves the right to change any product specifications without notice. Reprint, in whole or in part, only with permission of COMAP SA. 00817_2016-01_ENG 8