TREAT Startup Update

Similar documents
STATUS OF HIGHLY LOADED URANIUM-ZIRCONIUM HYDRIDE LOW ENRICHED URANIUM (LEU) FUEL PROGRAMS. G. B. West GA Technologies Inc.

1: CANDU Reactor. B. Rouben McMaster University Nuclear Reactor Physics EP 4D03/6D Sept-Dec September 1

IMPROVED BWR CORE DESIGN USING HYDRIDE FUEL

SPERT-III: REACTIVITY INSERTION ANALYSIS WITH SIMULATE-3K

OPAL : Commissioning a New Research Reactor. IAEA Conference, Sydney, November 2007

POWER RAMPING AND CYCLING TESTING OF VVER FUEL RODS IN THE MIR REACTOR

REGULATORY CONTROL OF NUCLEAR FUEL AND CONTROL RODS

Module 09 Heavy Water Moderated and Cooled Reactors (CANDU)

FBR and ATR fuel developments in JNC

ACCIDENT TOLERANT FUEL AND RESULTING FUEL EFFICIENCY IMPROVEMENTS

Outage dates (duration): March 2, 1993 to April 20, 1994 (1.1 years) Reactor age when outage began: 11.7 years

TerraPower s Molten Chloride Fast Reactor Program. August 7, 2017 ANS Utility Conference

Nuclear Thermal Propulsion (NTP) Engine Component Development

CNS Fuel Technology Course: Fuel Design Requirements

Fuel Reliability: Achieving Zero Failures and Minimizing Operational Impacts Rob Schneider, Senior Engineer/Technologist, Global Nuclear Fuel

Primary Heat Transport (PHT) Motor Rotor Retaining Ring Failure

Effect of Compressor Inlet Temperature on Cycle Performance for a Supercritical Carbon Dioxide Brayton Cycle

Generating Unit Model Validation Policy

WELCOME AND INTRODUCTORY REMARKS

WIPP Update. Jeffrey Carswell, Deputy Manager. Carlsbad Field Office Office of Environmental Management

SMR multi-physics calculations with Serpent at VTT

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER D: REACTOR AND CORE

Appendix J - 14 (EUB IR-16)

Re evaluation of Maximum Fuel Temperature

Appendix G Examples and Recommended Methods

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after January 1, 2014.

Fuel cladding stress evaluation for the control rods pattern change at the Shimane Nuclear Power Station Unit No1 and No2

NATIONAL NUCLEAR SECURITY ADMINISTRATION GLOBAL THREAT REDUCTION INITIATIVE Core Modifications to address technical challenges of conversion

A.L. Izhutov, A.V. Burukin, Current and prospective fuel test programmes in the MIR reactor

The role of CVR in the fuel inspection at Temelín NPP

Types, Problems and Conversion Potential of Reactors Produced in Russia

WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA. Treatment of Uranium Slugs at the CEA Marcoule site 12026

FIG Top view of the reactor core of the ARE. Hexagonal beryllium oxide blocks serve as the moderator. Inconel tubes pass through the moderator

Building a 21 st Century Electric Grid. February 23, 2018

Neutronics of Prismatic Fluoride Salt Cooled High Temperature Reactors

Thermal Hydraulics Design Limits Class Note II. Professor Neil E. Todreas

1. INTRODUCTION XA SLIGHTLY ENRICHED URANIUM FUEL FOR A PHWR

AP1000 European 4. Reactor Design Control Document CHAPTER 4 REACTOR. 4.1 Summary Description

Introduction and Summary

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after February 1, 2019.

ABB FACTS Customer Service. FACTS Care Upgrades

National Aeronautics and Space Administration! Leonard Dudzinski RPS Program Executive RPS Status for VEXAG

Super-Critical Water-cooled Reactors

Current and Prospective Tests in Reactor MIR.M1

Report No. IDO APPENDIX B ML-1 PLANT CHARACTERISTICS 1. GENERAL Mu to gas; 3.41 Mw total Cycle efficiency. Gross elect. wr. Net elect.

Emerald People s Utility District RATE SCHEDULES. Rate Schedules Effective April 1, 2018

Accident-related fuel experiments in Halden --- HRP LOCA Test Series IFA-650

TEXARKANA, TEXAS SERVICE AREA. First Revised Sheet No /7

Verifiably, Irreversibly Halting Operations at Yongbyon. David Albright, ISIS January 14, 2004

TRANSMISSION PLANNING CRITERIA

THE RENAISSANCE OF SODIUM FAST REACTORS STATUS AND CONTRIBUTION OF PHENIX

Energy Technical Memorandum

Energy Storage Interconnection Initiative

PASNY DELIVERY SERVICE. Applicability: To PASNY Customers who are not served under Rate II, Rate III, or Rate IV.

PASNY DELIVERY SERVICE. Applicability: To PASNY Customers who are not served under Rate II, Rate III, or Rate IV.

PASNY DELIVERY SERVICE. Applicability: To PASNY Customers who are not served under Rate II, Rate III, or Rate IV.

TEXARKANA, TEXAS SERVICE AREA. Original Sheet No /6. CenterPoint Energy Resources Corp. d/b/a CenterPoint Energy Arkansas Gas (Name of Company)

ANALYSIS OF BREST-OD-300 SAFETY DURING ANTICIPATED OPERATIONAL OCCURRENCES

Single-phase Coolant Flow and Heat Transfer

FLEXIBILITY & NUCLEAR ENERGY MANAGEMENT IN FRANCE

THE CURRENT STATUS ON DUPIC FUEL TECHNOLOGY DEVELOPMENT

Husky Stadium: TMP Modernization Project

A REPORT TO THE BOARD OF COMMISSIONERS OF PUBLIC UTILITIES. Electrical. Mechanical. Civil. Protection & Control. System Planning

A REPORT TO THE SoMo OF COMMISSIONERS OF PUBLIC UTILITIES. Electrical. Mechanical. Civil. System Planning. Overhaul Diesel Engines.

Using Apollo Solar Remote Monitoring Software

Yield vs simulation of Canadian Solar modules October 2012 QUALITY I VALUE I INNOVATION

AP1000 European 5. Reactor Coolant System and Connected Systems Design Control Document

Recent Predictions on NPR Capsules by Integrated Fuel Performance Model

REDACTED PUBLIC VERSION HPC PCSR3 Sub-chapter 4.2 Fuel Design NNB GENERATION COMPANY (HPC) LTD REDACTED PUBLIC VERSION HPC PCSR3: { PI Removed }

Nuclear Fuel Industry in China. Sao Paulo, Brazil Oct, 2015

I-820 (East) Project Description. Fort Worth District. Reconstruct Southern I-820/SH 121 Interchange

CAREM PROTOTYPE CONSTRUCTION AND LICENSING STATUS

Preliminary Alternatives Analysis Caltrain Modernization & High Speed Train Projects City of Millbrae

NCAA Division I Championship Subdivision Football Recruiting Calendar August 1, 2017, through July 31, 2018

REPORT TO THE CHIEF ADMINISTRATIVE OFFICER FROM THE DEVELOPMENT AND ENGINEERING SERVICES DEPARTMENT COMPRESSED NATURAL GAS TRANSIT FLEET UPDATE

RESILIENT SOLAR CASE STUDY: SUNY New Paltz NYPA Integrated Grid Pilot

PHASE 4 OVERLANDER PROTECTED MOBILITY VEHICLE LIGHT

Quarterly Activities Report

Late Starter. Tuesday, November 6, 2018

R&D Activities at INR Pitesti Related to Safety and Reliability of CANDU Type Fuel

Lantech Demo / Inventory Equipment for Sale

SOUTHERN GATEWAY. Transportation and Trinity River Project Committee 11 May 2015

JOYO, THE IRRADIATION AND DEMONSTRATION TEST FACILITY OF FBR DEVELOPMENT

GT-MHR COMMERCIALIZATION STUDY

A Helium Cooled Particle Fuelled Reactor for Fuel Sustainability. T D Newton, P J Smith, Y Askan. Serco Assurance. Work Sponsored by BNFL

(3) 2-Loop B&W PWR s Unit 1- Commissioned 7/5/1973 Unit 2- Commissioned 9/9/1974 Unit 3- Commissioned 12/16/ MW per unit for a total of 2880 MW

NERC Load Modeling Activities. Ryan D. Quint, PhD, PE Senior Engineer, System Analysis, NERC MRO Fall Reliability Conference November 2016

Impacts of Hurricane Sandy to NYCDEP WWTPs and Pump Stations. December 12, 2012

Everybody talks about the weather, but nobody ever does anything about it. Mark Twain

SUMMARY REPORT ON EVALUATION OF A FUEL ADDITIVE AT SOUTHWEST RESEARCH INSTITUTE SAN ANTONIO, TEXAS

Honda Financial Statement Changes. January Dear Accounting Customer:

Market Drivers for Battery Storage

EXPERIENCE WITH SOLUTIONS TO CONVERSION CHALLENGES. for U.S.-Supplied Research Reactors EXPERIENCE WITH SOLUTIONS

WELCOME Open House on Parking

GLAST Large Area Telescope:

ELECTRICAL AREA CONTROLLED ACCESS PROCEDURE SP-18 NATIONAL HIGH MAGNETIC FIELD LABORATORY NHMFL FLORIDA STATE UNIVERSITY SAFETY PROCEDURE SP-18

Opportunities to minimize stocks of nuclear-explosive materials *

INTRADEPARTMENTAL CORRESPONDENCE. The Honorable Board of Police Commissioners ^ECUTIVE DIRECTOR

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-27 CUSTOMER GENERATION PRICE PLAN FOR RESIDENTIAL SERVICE

Action Requested From AMWG

Transcription:

Resumption of Transient Testing Program TREAT Startup Update John D. Bumgardner Director, Resumption of Transient Testing Program December 5 th, 2018 1

Facility Location 2

Nuclear Fuels Development Requires Transient Testing for Design Development and Qualification Nuclear fuel tends to fracture during use or when exposed to a power burst, it is important for the fuel to retain reasonable structural integrity During a transient test, fuel is exposed to a power to cooling mismatch, driving the fuel to high temperatures Transient testing fuel and crash testing cars have a lot in common: Design and test for high safety standards 3

Fuel Development Cycle

TREAT Reactor Top of the Reactor Designed to conduct transient testing of fuels and structural materials. Operated from 1959 to 1994. Reactor has performed 6604 reactor startups, 2884 transient irradiations. Major refurbishment completed in the late 1980 s, and upgraded reactor ran from 1989 to 1994. Reactor remained fully fueled during standby from 1994 to now, plant left in excellent condition with all required surveillance and maintenance activities performed. Over 20 GW Peak Transient Power (120 kw Steady-state power). Core: 4 ft. high x roughly 6 ft. dia.; surrounded by 2 ft. graphite reflector. Fuel: 19 x 19 array (approximately 360 fuel elements) of 4 in. X 4 in. fuel and reflector assemblies. LEU conversion work initiated. South View of the Reactor 5

TREAT Configuration and Unique Features No decay heat mitigation actions required Negligible decay heat Low fission product inventory No emergency cooling or residual heat removal required No emergency power required Self-limiting Near instantaneous large negative temperature coefficient safely shuts the reactor down, inherently safe Reactor Trip System is not required to prevent fuel damage Reactivity Control and Operation Prompt critical operation normal mode Air cooling system has a non-safetyrelated function operated during steady-state operations or to prepare for next transient Three independent Control Rod Drive types Transients performed from remote Control Room Self-contained experiments 6

RTTP Recap and Highlights Managed as a reactor being returned to service following an extended outage. Relied on operations and maintenance history and experienced operating personnel. Required activities completed for restart include: Systematic approach used to return facility systems and equipment to service. Procedures and processes revised to current standards. Hired and trained full operating staff. Thoroughly tested and exercised all equipment and systems supporting reactor operations. Extremely good safety record with no significant injuries. Resumption of Transient Testing Program (RTTP) was completed August 31, 2017, more than twelve months ahead of the baseline schedule of September 2018 and for about $20M less than the baseline cost estimate of $75M. On November 14, 2017 the Reactor critical operations resumed after over two decades of standby.

TREAT Restart Timeline 2011: Mission need approved for transient testing 2014: In February NEPA process completed and FONSI approved, TREAT selected as the reactor to perform transient testing 2014: After February initiated assembling restart team, initiated infrastructure items such as facility cleanout, roof replacement, initiated system walkdowns 2015: Revised and implemented SAR and TS to allow control rod and in core activities, DOE RA performed, system testing initiated, facility repairs and refurbishment under way 2016: Poisoned core and validated, replaced Transient Rod shock absorbers, completed plant significant modifications, initiated integrated plant simulated operations 2017: Completed all personnel, plant, and process preparations, initiated and completed review processes, low power testing initiated 2018: Physics testing, completion of restart plan, initiate experimental operations ~ March 2018 8

Equipment Readiness Journey 9

Future of TREAT Operations The Reactor will continue to be operated through 2017 at low power for startup testing. Experiments and testing of new cutting edge instruments is expected to commence in calendar year 2018. There is great interest in use of TREAT, anticipated customers and research are under development Dan Wachs is giving a Transient Testing experiment presentation later in the meeting. 10

The National Nuclear Laboratory 11

Fuel Assembly Standard Fuel Assembly Central uranium oxide-bearing Fuel Section Upper and lower Graphite Reflector Sections Fuel Section Standard is 4 feet long, contains six 8 inch long fuel blocks, specialized use less fuel 1 part HE UO 2 to 10,000 parts carbon/graphite 37g HE UO 2 per fuel element Clad in Zr-3, under vacuum Carbon and Graphite Urania Fuel High heat-absorption capability provides heat sink for transient heat without cooling dependence. Homogeneity of fuel and moderator provides near instantaneous large, negative temperature coefficient. Excellent thermal shock resistance sustain high rates of heat input during transient operation. Less than 0.3% burnup on existing fuel, indicating remaining fuel life well in excess of the 40 year programmatic projected need. Graphite Reflector Sections 2 feet long each Fuel Configurations 1 2