STRUKTURA T01-A INSTALLATION INSTRUCTIONS

Similar documents
BARDON T01-C TOUCHLESS URINAL SENSOR INSTALLATION INSTRUCTIONS K-8787T-C02(DC/ ) K-8787T-C04(AC/ ) 18 E

8791T-C02( ) 8791T-C04(AC) 8791T-C04( ) size alkaline batteries(8791t-c02) 2 7 (AAA 2)(8791T-C02) 220V AC 50/60Hz(8791T-C04)

mm (16.1" 3.74" 3.86" ) Soap Tank Capacity 750ml Battery. 750ml AA (1.5V) 4

CIMARRON TM ORDERING INFORMATION T01-E

INSTALLATION INSTRUCTIONS TOILET. Castello & Sienna Back-to-Wall

WELLWORTH WATER-GUARD WITH PEACEKEEPER VITREOUS CHINA SIPHON JET TOILETS

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

Halsey Taylor Owners Manual

Installation Instructions

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

Installation Instructions

Installation Instructions

Installation Instructions

Operation and Maintenance Instructions

Table of Contents. AMO series quantitative pressured centralized lubricating system 1. Illustration of AMO motor driven lubricating system 1

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website

Service Handbook. High-Pressure Washer Pump

Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Soap/Sanitizer Dispensers

Homeowner Guide. Dual-Flush Two Piece Toilet A5-N

200 HYDRO-TOWER 200. Ordering Information. Wall-hung Toilet That Matches The Tank. Function Explanation

Soap/Sanitizer Dispensers

Subaru Front Mount Intercooler Kit STI Subaru Front Mount Intercooler Kit STI

Halsey Taylor Owners Manual

Installation Instructions

Maintenance Information

Installation Instructions

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

4 - Way Control 4 - Way Control 4 - Way Control with lock

Installation instructions

IRS-151 INSTALLATION INSTRUCTIONS `55-57 CHEVY INDEPENDENT REAR SUSPENSION

Polypropylene Piston Drum Pumps

Maintenance Information

Installation Instructions

Homeowner s Guide. For Dual-Flush Toilets A5-H

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

Installation Instructions

INSTALLATION INSTRUCTIONS FUEL RAIL

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES

Service Manual Air Tech Second Stage

WARNING Carefully Read These Instructions Before Use

INSTALLATION INSTRUCTIONS

House Hydrant Installation Instructions

INSTALLATION INSTRUCTIONS STUDIO S

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Lifting height 5.5" - 72" with adapters " Height overall 165" Width between columns 122" Drive through 109" Width overall 151.

Installation/Care/Use Manual

GPS AutoSteer System Installation Manual

CONTENTS. Product Features and Specifications Installation Requirement Installation Exploded View Operation Instruction...

High Pressure Abrasive Blast Cabinet 42000

Maintenance Information

Rosemount 402 and 402VP

The following information shows the steps to change the rear brake pads and rotors on an E36 chassis.

Foss Electric Milko-Scope II Meter Manual

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)

Installation Guidelines

Maintenance Information

RX-AFRO3-AQ Installation Manual

Operating Manual for Hands-Free Wall Mounted Sinks Models 504 and

Page 1. File: Motolight caliper one-piece Date: 8/14/2006

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Geberit Manufacturing, Inc Boone Drive, Michigan City, IN Phone: (800) Fax: (219)

100 HYDRO-TOWER 100 ODEON

INSTALLATION INSTRUCTIONS PATIENCE

Maintenance Information

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

Service Handbook High-Pressure Washer Pump

Installation/Care/Use Manual

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

Installation For Service Only

Installation Instructions

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

Installation Instructions

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

20 TON AIR/MANUAL BOTTLE JACK

ENGINE LUBRICATION & COOLING SYSTEMS SECTIONLC CONTENTS. ENGINE LUBRICATION SYSTEM...2 Precautions...2

Installation Manual TWM Performance Short Shifter Subaru STi 2008+

G2 Optima Plus Flushometer

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

Installation Instructions

Installation Instructions

Maintenance Information

The ionpia H 2 Owner s Manual

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

D/G-35 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically

Installation Instructions

Installation Instructions

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

MODEL:D-1000X D-1000XLD D-1000Y D-1000YLD D-1000Z

JEEP TJ & (XJ 84-01) ATLAS 2 SP.

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

Transcription:

STRUKTURA INSTALLATION INSTRUCTIONS ( ) TOUCHLESS URINAL(REAR INLET) K-5888T(3L/DC)/K-5888T-C05(3L/AC) K-5888T-W(1L/DC)/K-5888T-WC05(1L/AC) K-5888T-Y(0.5L/DC)/K-5888T-YC05(0.5L/AC) BEFORE YOU BEGIN Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. All information in these instructions is based upon the latest product information available at the time of publication. Kohler China reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and warranty information - please leave instructions for the consumer. Observe all local plumbing and building codes. Carefully inspect the new urinal for damage. Site preparation may require additional tools and hardware. CAUTION: Risk of personal injury or product damage. Handle with care. Vitreous china can break or chip if the product is handled carelessly. RECOMMENDED TOOLS AND MATERIALS (NOT SUPPLIED) ( ) Open end/adjustable wrenches Tape measure Basin wrench Pipe wrench Square Level Pliers Socket wrench with sockets Screw driver Seal tape Connection wire Wire cutter Insulation tape Bushing Drill Sealant / - 137458-T01-A -1-, 014 Copyright Kohler China Ltd., 014

SPECIFICATIONS Power Liter per flushing Temperature Starting pressure Testing time Detecting method " AA" size alkaline batteries(dc) 0V AC 50/60Hz (AC) Water pressure at 0.18~0.55 MPa: Less than 3L (K-5888T(3L/DC)/K-5888T-C05(3L/AC)) Less than 1L (K-5888T-W(1L/DC)/K-5888T-WC05(1L/AC)) Less than 0.5L (K-5888T-Y(0.5L/DC)/K-5888T-YC05(0.5L/AC)) Environmental temperature: 1 to 55 C 0.07Mpa (Dynamic pressure)~0.86mpa (Static pressure) About to 5 seconds Detecting the urine and human movement 5 (AA )( ) 0V AC 50/60Hz ( ) 0.18~0.55MPa. K-5888T(3L/DC)/K-5888T-C05(3L/AC) 3L K-5888T-W(1L/DC)/K-5888T-WC05(1L/AC) 1L K-5888T-Y(0.5L/DC)/K-5888T-YC05(0.5L/AC) 0.5L 1~ 55 C 0.07Mpa( )~0.86MPa( ) 5 ROUGHING-IN Reference Value Unit:mm * Recommended dimensions for installation only, please adjust according to actual situation. * 361 340 91 545 30 3 744 165 158 40 73 Supply " NPT Tap " *600 *447 Wall Floor Kohler reserves the right to change marked dimensions without prior notice. Fig.1 1 Roughing-in dimensions are identical if using an optional 3"outlet spud. 3" 137458-T01-A --

Notice: To ensure an effective flush performance, strongly recommended inner diameter of water supply (including water meter, valve, etc.) is no less than 5mm, and supplied water pressure (sensor inlet dynamic pressure) is 0.18MPa ~0.55MPa. ( ) 5mm ( ) 0.18MPa ~0.55MPa PREPARE THE SITE NOTE: If a pre-existing waste pipe will be used and will result in an acceptable rim height (refer to the rough-in dimensions), follow the retrofit installation instructions. For Retrofit Installations Turn the water supply line off, remove the existing urinal, then cap off the water supply line inside the wall. For New Installations Install waste pipe as necessary to conform to the roughing-in dimensions. Install adequate support framing for the hangers as needed. ) ( Wall Drain Connection Wall Hangers INSTALLATION A. Install hangers, L shape block and waste pipe connector Drill holes according to template. Install hangers, L shape block and waste pipe connector. (Gasket of waste pipe connector shall be soaked into water for seconds to lubricate.) Fig. A. L L ( ) Wall Wall Insert the connector into the waste pipe in the wall along this direction. Wall Hangers 35 Pre-installed waste pipe connector Move the gasket to front of the pipe before connecting to the urinal. Fig.3 3 137458-T01-A -3-

B. Install urinal B. Test flushing. Remove regulator (supplied only for 3L urinal) when water pressure is too low. 3L Back of Urinal Remove Regulator Nozzle Fig.4 4. Connect inlet pipe and fill valve. Hang the urinal onto the hangers. 4. Loosen the nut and drag the clamp towards center. Take out the fixture, valve and battery box assembly at the bottom. Load batteries. 5. Pull the bottom of the urinal outwards to make space. Align the big nut with the waste pipe and then tighten. 6. Push the urinal against wall and tighten it with screws.. 4. 5. 6. 7. Fix the connectors and then put the fixture, valve and battery box assembly back into the urinal. 8. Apply silicone sealant between urinal and wall. 7. 8. Screw Hole Big Nut Fixture, Valve, Assy Clamp Lock Nut Fig.5 5 Fig.6 6 137458-T01-A -4-

C. Adjust the hanger As shown in the picture below, firmly press the hanger with the bolt through the waist-shaped hole. C. Waist-shaped Hole Fixing Hole Fig.7 7. As shown in the picture below, if the position of the urinal needs to be adjusted, please take down the urinal and knock the hanger slightly to adjust its position upwards and downwards.. Adjust Upwards and Downwards Fig.8 8 After the position of the urinal is decided, completely fix the hanger with the bolt through the fixing holes on the hanger. D. Install the drain and the plastic trap D. Put the washer onto the drain and insert it into the hole.. Put the gasket and nut on the bottom. NOTE: Do not over screw the nut in this step, because it is to be screwed tight in the next step after the pipe is installed.. Fig.9 9 Connect the hose with the trap. 4. Screw the trap onto the drain and screw tight. 5. Screw tight the nut of the drain mentioned in step. 4. 5. Fig.10 10 137458-T01-A -5-

6. Screw on the drain lid(for first-time installation, the water may drain slowly. It can be improved by loosening the drain cover). The drain after being loosened is as shown. 6. ( ) Fig.11 11 E. Install the manual button and magnetic valve E. Install the magnetic valve. Fig.1 1. Install the manual button. Insert the button into the hole, then put on the washer and the nut.. Fig.13 13 Connect with the hose. Supply Fig.14 14 F. Install the sensor controller F. Install the sensor controller box.. Connect the sensor wire.. Fig.15 15 137458-T01-A -6-

G. Install and uninstall the Fixture, Valve Battery Box Assembly Unscrew the screws on the Fixture, Valve, Battery Box Assembly and withdraw the clamp. Remove the Fixture, Valve Battery Box Assembly from the urinal by moving it rightwards and then downwards. Fix the Fixture, Valve Battery Box Assembly back to the urinal by doing the above steps inversely. G. Screw Stop_Filter Assy Clamp Stop_Filter Assy H. Power Connection H. Wall Fig.16 16 Outer diameter of bush is no more than 5mm <5mm Please directly reference to Fig.1 when installing K-5888T, K-5888T-W or K-5888T-Y(DC).. Please match 16306T-NA AC power unit when installing K- 5888T-C05, or K-5888T-WC05, or K-5888T-YC05(AC). The way of installation is as shown. Outer diameter of bush is no more than 5mm <5mm K-5888T K-5888T-W K-5888T-Y 1. K-5888T-C05 K-5888T-WC05 K-5888T- YC05 16306T-NA 300 600 Floor Fig.17 17 CAUTION: a. Do not connect 0V AC Power supply to DC wiring terminal. b. Do not damage the covering of AC power unit or remove screws to avoid leakage. AC Connector Wire prepared by customer Connector a. 0V b. 16306T-NA AC Power Unit A. Fig.18: AC power unit connect way: AC power unit is connected to electric control box by connection wire. A. 18 Connect with the same color wire, and protect connect area by insulation tape. Fig.18 18 Control Box Assy. 137458-T01-A -7-

B. When installing the power uint on the ceiling, please layout bushing according to Fig.19 and thread wire through the bushing. Fig.19: Connection sketch while installing power uint on the ceiling. B. 19 CAUTION: One AC power unit can supply two sensors at most. Ceiling Bushing AC Power Unit " NPT Tap " Bushing " NPT Tap " 600 Bushing 600 447 447 300 300 Floor Fig.19 19 Notice: a. Keep the connector away from water. b. Don't mistake the direction of inlet and outlet. c. Do not connect the DC output of AC power unit to AC power supply. d. Do not connect to power supply while installing. Connection line is not supplied. AC connection wire with insulating sleeving is recommended. Wire of which the nominal sectionn area of conductor is not less than 0.5mm is also recommend. DC connection line use wire of which the nominal section area is not less than 0.3mm. It is cut according to acted installation requirements (The length of cut wire is recommended less than 10m). e. The head AC power supply must be protected with appropriate fuse. f. Please confirm the AC power supply and water supply should be shut off before maintaining the products with AC power related. a. b. c. d. e. f. 0.5mm 0.3mm 10m 137458-T01-A -8-

, USER S GUIDE Illustrations The urinal will automatically flush after using. 1 3 Fig.0 0 Replacement of Batteries When the batteries run out, please remove the Battery Box Assembly by following the instructions in step C and then replace the batteries. C Screw M3 M3 Cover of Battery Box Battery Box Fig.1 1 Deodorizing Flushing The urinal will take a flush automatically when it's used 3 or 4 times in minutes. 3-4 137458-T01-A -9-

Manual Flushing Press the manual button for about 1 second and the urinal will automatically flush once. Sensorless Cleaning Mode Enter the sensorless cleaning mode by pressing the manual button for about 3 seconds after the flushing is finished. The controller will ring twice every seconds. Under this mode, press the manual button for about 1 second to start or stop flushing. The longest continuous flushing time is about 15 seconds. The urinal will automatically exit this mode after it started for about 8 seconds. You can also exit this mode by pressing the manual button for about 5 seconds. The controller stops ringing after the urinal exiting this mode. Notice: This function can be used after the power is turned on for ten minutes. Manual Button Fig. MAINTENANCE Clean the Filter Screen If the flushing volume reclines sharply after installation or used for a long time with no cause from water pressure, the filter may need a wash. Please operate as following steps: Remove the Fixture, Valve, Battery Box Assembly and take out the filter, clean the filter and then reinstall it. Caution: a. Turn off the water supply and power supply before cleaning the filter. b. Avoid damaging or losing the filter during cleaning. Fixture, Valve, Battery Box Assy. Filter Valve Cap Kit a. Fig.3 3 b. 137458-T01-A -10-

TROUBLESHOOTING Please make following checks before repair: Symptoms Probable causes Corrective actions No flushing No flushing or poor flushing No flashing No power or mistake connected.. Not able to detect the urine. Out of electricity. Adjusting bolt not fully open. Low water pressure. Filter is obstructed. The small hole of valve core is blocked.. The filter of valve core is blocked. If the trouble remains after above-mentioned actions are taken, please contact with us via distributor. Check the power connect.. See user's guide. Replace batteries. Open the adjusting bolt.. Improve water supply. Clean the filter. Clean the small hole of valve core with thin steel wire.. Wash the filter of valve core with a brush....... IMPORTANT CONSUMER INFORMATION Consumer Responsibilities Do not directly flush the sensor with water. The sensor is an electronic instrument.. Keep away from strong electromagnetic field. Clean the urinal with soft rag and neutral liquid detergent. Do not use eradicator, abrasive powder or oil, acid or alkali liquid detergent. 4. Urinal is designed for use with potable water. Avoid water that includes a lot of contaminants or acid/alkali water and impure water. 5. All electrical connection must be compliance with related regulation and codes. 6. All installation staff should be well familiar with installation instruction.. 4. 5. 6. WARNING Never spit phlegm and throw stub or something else into the urinal. Please avoid using articles either dissolvable or with the diameter smaller than 5mm, such as moth ball. 5mm WARNING: Risk of product damage. Do not throw into the urinal what is easy to block it, such as newspaper, paper pilch. Do not bump the vitreous china with great force to prevent it from damaging and leaking. o Do not use the product in the water below 0 C. 0C o CAUTION: Please do not use hard materials (like scouring pad) to clean product surface, especially the product logo. 137458-T01-A -11-