SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217.

Similar documents
MODEL GSW80 Deutz & 110 Perkins.

MODEL GSW Deutz.

MODEL GBW15-22 Yanmar

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMR - 67P 67P 09/05/2016 GMR - 067P

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

P6000s 230V 50Hz #CONN #DPP

THE COMPLETE PETROL PACKAGE

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

POWER ENGINEERING KVA 50 HZ rpm

S V50HZ #AVR #CONN #DPP

P V 50HZ #CONN #DPP

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Proud To Be Manufactured- IN THE UK

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Standby Amper VOLTAGE

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Standby Amper VOLTAGE

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

TECHNICAL SPECIFICATIONS

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GSW SERIES COMPACT ENERGY

CGT Stamford UCI 274 E1

ENGINE brand Yanmar Yanmar Yanmar Perkins Perkins model 3TNV76 3TNV88 4TNV88 403D-15G 404D-22G Cooling system Water Water Water Water Water

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

GE.PK.022/020.SS+0_all

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

MPL series S MPL 15S MPL 22S. max. power 13,1 kva. max. power 22 kva GENERATORS. Standard version

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

GQW1400V. 1MWe TWINGEN in container 20 HC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

19 KW / 24 KVA POWERED by

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Rating Definitions and Conditions

LP 10. GENERATOR SPECIFICATION Power Rating (KVA) 10. Electric Power (KWe) 8. Rated Current (A) 14. No of Phases/Volts* 3/415

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Technical specification

Rating Definitions and Conditions

GE.VO.360/325.SS+0_all

Transcription:

GENERATING SET TECNICAL GUIDE GSW65-1D Open set z REF. GDS GSW65-1 Deutz cooling system. Industrial muffler. CODE SG740TDA SG101TDA SG141TDA PRIME POWER PRP 74,1 (59,3) 102,5 (82,0) 8,2 (102,6) EMERGENCY POWER LTP 78,5 (62,8) 108,1 (86,5) 141,9 (113,6) age Frequency z Power factor Cos φ Fuel capacity Litres h 15,3 10,4 8,6 mm Autonomy ( 100% load PRP) Dimensions (LxWx) TECNICAL FEATURES GSW1D Weight kg 1.169 1.317 1.369 DEUTZ BF4M 20C BF4M 1013EC BF4M 1013FC Cooling system Speed rpm 1.0 1.0 1.0 Displacement c.c. 4.040 n disp. Aspiration Engine power PRP kwm 66,1 91,1 1,0 l/h 17,1 23,0 28,0 g/kwh 217 2 210 (EMR) DIESEL ENGINE Cyliders and disposition Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) Electrical system (DC) ALTERNATOR Stamford UCI 224F UCI 274C UCI 274E Insulation Class degree protection age regulation GSW1D TECNICAL CARACTERISTICS NOT IMPEGNATIVE RESERVATION OF MODIFICATIONS FOR INNOVATION OF TE PRODUCT Complete with engine and battery liquids. (*) Model on discontinuation. through Genereting set voltage (3 phases). Generating set frequency. Generating set current (3 phases). Battery voltage. Power ( kva). ours-counter. Fuel level (%). Engine temperature. Start/stop selector switch with key. Emergency stop button. display plus engine protection unit for Rev.00 Engine protections: low fuel level, low oil pressure, high engine temperature. Engine protections: low fuel level, low oil pressure, high engine temperature. Circuit breaker protection: III poles. Differential protection. Power cables connection directly from circuit breaker. Pag. 1 of 3

GENERATING SET TECNICAL GUIDE GSW65-1D Open set z TECNICAL CARACTERISTICS NOT IMPEGNATIVE RESERVATION OF MODIFICATIONS FOR INNOVATION OF TE PRODUCT Automatic control panel control unit AC03 for monitoring, control and through AC-01 Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and control unit AC03 for GSW1D Four operation modes: OFF - Manual starting - Automatic starting - Automatic test. Pushbutton for forcing Mains contactor or Genset contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Emergency stop button. Remote starting availability. DC system disconnection switch. Acoustic. Automatic battery charger. RS232 Comuncation port. Setable PASSWORD for protection level. Genereting set voltage (3 phases). Mains voltage. Generating set frequency. Generating set current (3 phases). Battery voltage. Power (kva - kw - kvar). Power factor Cos φ. ours-counter. Engine speed r.p.m. Fuel level (%). Engine temperature (depending on model). Oil pressure (depending on model). Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, Engine protections: low fuel level, low oil pressure, high engine temperature, Genset protection: under/over voltage, overload, Circuit breaker protection: IV/III poles (depending on model). Differential protection by means of the Plinth row for connection from ACP to LTS panel. Power cables connection directly from circuit breaker. Genereting set voltage (3 phases). Mains voltage. Generating set frequency. Generating set current (3 phases). Battery voltage. Power (kva - kw - kvar). through AC-03 Mains/Genset Power factor Cos φ. ours-counter. Engine speed r.p.m. Fuel level (%). Engine temperature (depending on model). Oil pressure (depending on model). GSW1D Four operation modes: OFF - Manual starting - Automatic starting - Automatic test. Pushbutton for forcing Mains contactor or Genset contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Emergency stop button. Remote starting inhibition availability. Acoustic. Automatic battery charger. RS232 Comuncation port. Setable PASSWORD for protection level. IV poles - 5 A. IV poles - 160 A. IV poles - 2 A. Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, Engine protections: low fuel level, low oil pressure, high engine temperature, Genset protection: under/over voltage, overload, Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) AFP: AUTOMATIC FUEL TRANSFER PUMP. GENSET SUPPLEMENTS DCC: DIFFERENT CANOPY COLOUR. EEG: ENGINE ELECTRONIC GOVERNOR. PS: COOLANT PREEATING SYSTEM. Rev.00 Pag. 2 of 3

GENERATING SET TECNICAL GUIDE GSW65-1D Open set z CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) MAP: MANUAL ANALOGUE CONTROL PANEL. CONTROL PANEL SUPPLEMENTS with analogue, and protected through door with lockable handle. Instrumentation (analogue) meter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). ours-counter. Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key. Emergency stop button. Engine protections: low fuel level, low oil pressure, high engine temperature, battery Circuit breaker protection: III poles. Differential protection. Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery Power cables connection directly from circuit breaker. TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES. RSS: REMOTE START/STOP. Only for MCP. LOAD TRANSFER SWITC PANEL. GSW1D IV poles - 5 A. IV poles - 160 A. IV poles - 2 A. Connections Plinth row for connection from ACP to LTS panel. Terminals board for power cables connection (Genset-Mains-Load). Load transfer switch panel built in a metal cabinet and supplied loose from the genset. Protections Contactors mechanically and electrically interlocked. Emergency stop button. Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. FEC: FLEXIBLE EXAUST COMPENSATOR. RES: RESIDENTIAL SILENCER. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Available only for automatic versions with AC01 Rev.00 Pag. 3 of 3

GENERATING SET TECNICAL GUIDE GSW65-1D Open set z REF. GDS GSW65-1 Deutz cooling system. Industrial muffler. CODE SG740TDA SG101TDA SG141TDA PRIME POWER PRP 74,3 (59,4) 105,0 (84,0) 130,0(104,0) EMERGENCY POWER LTP 77,7 (62,2) 11 (88,6) 142,0 (114,0) age Frequency z Power factor Cos φ Fuel capacity Litres h 15,3 10,4 8,6 mm Autonomy ( 100% load PRP) Dimensions (LxWx) TECNICAL FEATURES GSW1D Weight DIESEL ENGINE kg 1.169 1.317 1.369 DEUTZ BF4M 20C BF4M 1013EC BF4M 1013FC Cooling system Speed rpm 1.0 1.0 1.0 Displacement c.c. 4.040 n disp. Aspiration Engine power PRP kwm 66,1 91,1 1,0 l/h 17,1 23,0 28,0 g/kwh 217 2 210 (EMR) Cyliders and disposition Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) Electrical system (DC) ALTERNATOR MeccAlte ECO 32 3L ECP 34 1L ECP 34 2L Insulation Class degree protection age regulation GSW1D TECNICAL CARACTERISTICS NOT IMPEGNATIVE RESERVATION OF MODIFICATIONS FOR INNOVATION OF TE PRODUCT Complete with engine and battery liquids. (*) Model on discontinuation. through Genereting set voltage (3 phases). Generating set frequency. Generating set current (3 phases). Battery voltage. Power ( kva). ours-counter. Fuel level (%). Engine temperature. Start/stop selector switch with key. Emergency stop button. display plus engine protection unit for Rev.00 Engine protections: low fuel level, low oil pressure, high engine temperature. Engine protections: low fuel level, low oil pressure, high engine temperature. Circuit breaker protection: III poles. Differential protection. Power cables connection directly from circuit breaker. Pag. 1 of 3

GENERATING SET TECNICAL GUIDE GSW65-1D Open set z TECNICAL CARACTERISTICS NOT IMPEGNATIVE RESERVATION OF MODIFICATIONS FOR INNOVATION OF TE PRODUCT Automatic control panel control unit AC03 for monitoring, control and through AC-01 Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and control unit AC03 for GSW1D Four operation modes: OFF - Manual starting - Automatic starting - Automatic test. Pushbutton for forcing Mains contactor or Genset contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Emergency stop button. Remote starting availability. DC system disconnection switch. Acoustic. Automatic battery charger. RS232 Comuncation port. Setable PASSWORD for protection level. Genereting set voltage (3 phases). Mains voltage. Generating set frequency. Generating set current (3 phases). Battery voltage. Power (kva - kw - kvar). Power factor Cos φ. ours-counter. Engine speed r.p.m. Fuel level (%). Engine temperature (depending on model). Oil pressure (depending on model). Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, Engine protections: low fuel level, low oil pressure, high engine temperature, Genset protection: under/over voltage, overload, Circuit breaker protection: IV/III poles (depending on model). Differential protection by means of the Plinth row for connection from ACP to LTS panel. Power cables connection directly from circuit breaker. Genereting set voltage (3 phases). Mains voltage. Generating set frequency. Generating set current (3 phases). Battery voltage. Power (kva - kw - kvar). through AC-03 Mains/Genset Power factor Cos φ. ours-counter. Engine speed r.p.m. Fuel level (%). Engine temperature (depending on model). Oil pressure (depending on model). GSW1D Four operation modes: OFF - Manual starting - Automatic starting - Automatic test. Pushbutton for forcing Mains contactor or Genset contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Emergency stop button. Remote starting inhibition availability. Acoustic. Automatic battery charger. RS232 Comuncation port. Setable PASSWORD for protection level. IV poles - 5 A. IV poles - 160 A. IV poles - 2 A. Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, Engine protections: low fuel level, low oil pressure, high engine temperature, Genset protection: under/over voltage, overload, Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) AFP: AUTOMATIC FUEL TRANSFER PUMP. GENSET SUPPLEMENTS DCC: DIFFERENT CANOPY COLOUR. EEG: ENGINE ELECTRONIC GOVERNOR. PS: COOLANT PREEATING SYSTEM. Rev.00 Pag. 2 of 3

GENERATING SET TECNICAL GUIDE GSW65-1D Open set z CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) MAP: MANUAL ANALOGUE CONTROL PANEL. CONTROL PANEL SUPPLEMENTS with analogue, and protected through door with lockable handle. Instrumentation (analogue) meter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). ours-counter. Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key. Emergency stop button. Engine protections: low fuel level, low oil pressure, high engine temperature, battery Circuit breaker protection: III poles. Differential protection. Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery Power cables connection directly from circuit breaker. TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES. RSS: REMOTE START/STOP. Only for MCP. LOAD TRANSFER SWITC PANEL. GSW1D IV poles - 5 A. IV poles - 160 A. IV poles - 2 A. Connections Plinth row for connection from ACP to LTS panel. Terminals board for power cables connection (Genset-Mains-Load). Load transfer switch panel built in a metal cabinet and supplied loose from the genset. Protections Contactors mechanically and electrically interlocked. Emergency stop button. Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. FEC: FLEXIBLE EXAUST COMPENSATOR. RES: RESIDENTIAL SILENCER. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Available only for automatic versions with AC01 Rev.00 Pag. 3 of 3