PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

Similar documents
GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GMR - 67P 67P 09/05/2016 GMR - 067P

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GE.PK.022/020.SS+0_all

GE.VO.360/325.SS+0_all

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

THE COMPLETE PETROL PACKAGE

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

GMP80PX/ Features:

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

S V50HZ #AVR #CONN #DPP

P6000s 230V 50Hz #CONN #DPP

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

DIESEL GENERATOR SET MTU 20V4000 DS4000

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

GQW1400V. 1MWe TWINGEN in container 20 HC

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMP400PX/ Features:

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

WPS150/S EP Series. Features:

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 12V1600 DS660

GMS800C/ Features:

60 Hz FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SET MTU 16V4000 DS2500

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

The enginewithintegrated water cooling

DIESEL GENERATOR SET MTU 12V4000 DS2250

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

DIESEL GENERATOR SET MTU 20V4000 DS3600

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

WPS60/S EP Series. Features:

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

DIESEL GENERATOR SET MTU 12V4000 DS1650

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

P V 50HZ #CONN #DPP

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

DIESEL GENERATOR SET MTU 16V2000 DS1100

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS3300

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

DIESEL GENERATOR SET MTU 16V2000 DS1000

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

DIESEL GENERATOR SET MTU 16V2000 DS KVA

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

WPS100/S EP Series. Features:

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

DIESEL GENERATOR SET MTU 4R0113 DS80

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

DIESEL GENERATOR SET MTU 16V4000 DS2500

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

WPS350/S EP Series. Features:

DIESEL GENERATOR SET MTU 10V1600 DS500

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

DIESEL GENERATOR SET MTU 16V4000 DS2250

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

WPS20/S EP Series. Features:

Transcription:

PRAMAC GBW 45 Item code: SB450TPAY00 Main features Standby : 36 kw power LTP Rated prime : 34 kw power (PRP) Rated : kw continuous power (COP) Phases : 3 Voltage : 400 V Frequency : 50 Hz Engine : Perkins manufacturer Fuel : Diesel Speed : Mechanical governor GBW 15-45 Series (purely indicative picture) Family with optimized features specially focused to meet the needs of low investment applications. Generators of reduced dimensions and weight making it easy to transport and store. Ideal for rental use. Technical specifications Standard equipment, options and accessories Main specifications Type Canopied Standby power LTP 45 kva Standby power LTP 36 kw Rated prime power (PRP) 43 kva Rated prime power (PRP) 34 kw Rated continuous power (COP) Rated continuous power (COP) Phases 3 Voltage 400 V Frequency 50 Hz Battery charger current 65 A Circuit breaker 63 Ratio 1,02

Engine specifications Engine manufacturer Perkins Model 1103A-33TG1 Stroke 4, diesel Fuel Diesel Number of cylinders and disposition 3, inline Displacement 3300 cm³ Air intake Turbocharged Starting system Electric Nominal operating speed 1500 rpm Speed governor Mechanical SAE Flywheel Continuous power COP Prime power PRP 41,3 kw Standby power LTP 45,6 kw Lube oil capacity 7,9 l Coolant capacity 10,2 l Fuel consumption at 100% PRP 10 l/h Fuel consumption at 75% PRP 7 l/h Maximum lube oil consumption at PRP 0,15 % Electric circuit voltage 12 V Engine derating 1,0 Cooling fan Mechanical Alternator specifications Alternator manufacturer MeccAlte Model ECO 32 3S Poles 4 Revolution speed 1500 rpm Voltage 400 V Frequency 50 Hz Continuous nominal power at 40 C - COP 40 kva Continuous nominal power at 27 C - PRP 42,5 kva Standby power at 27 C - LTP 44,6 kva Continuous active power at 27 C - PRP 34 kw Efficiency at 75% load 91,2 % Efficiency at 100% load 90,8 % Maximum admitted overload 10% for 1 hour every 12 hours of running time S2 Voltage regulation system Electronic Alternator derating 1,0 Protection grade IP 21

Additional information Fuel tank location Fuel tank capacity Running time at 100% PRP Running time at 75% PRP Measured acoustic power (LWA) at 10 mt Noise level at 7 m Guaranteed noise level (LWA) Internal 51 l 5,32 h 7 h 89 dba 64 dba 91 dba Dimensional data Length Width Height Dry weight 2000 mm 920 mm 1300 mm 953 kg Installation data Cooling fan air flow rate 53 m³/min Combustion air flow at PRP 2,6 m³/min Exhaust gas flow at PRP 7 m³/min Exhaust gas temperature at LTP 489 C Exhaust pipe diameter 48 mm Maximum admitted total exhaust backpressure 1000 mbar Equipments Mechanical speed governor Electronic speed governor Radio interference suppression Standard AVR (Automatic Voltage Regulator) AVR (Automatic Voltage Regulator) Underspeed protection 12 V electric circuit 24 V electric circuit Air intake filter Equipment: panel On-board ACP (Automatic Control Panel) ACP (Automatic Control Panel), delivered loose On-board LTS (Load Transfer Switch) panel LTS (Load Transfer Switch) panel, delivered loose Power section with circuit breaker delivered loose

Power section with on-board circuit breaker Differential protection Engine coolant preheater Manual oil draining pump Equipment: basic engine configuration Optimized fuel consumption Equipment: starting system Single pneumatic starter motor Electric starter and compressed air starter 2 electric starters with separate power supply Equipment: batteries Batteries Battery liquid Battery disconnecting device Equipment: fuel feeding system Air filters with contamination indicator Fuel level sensor (minimum and maximum) Fuel main filter Fuel prefilter water separator Electric valve for fuel circuit Equipment: lube oil system Lube oil filler neck, dipstick Lube oil fine filter Lube oil cooler Equipment: exhaust line No silencer option Catalytic silencer Spark arrester Flexible exhaust compensator Connection flanges to exhaust line Equipment: silencer

Industrial silencer -15 db(a) Residencial silencer -35 db(a) Equipment: engine switches and senders Fuel minimum level switch Coolant minimum level switch Coolant temperature switch Coolant temperature sender Lube oil minimum level switch Lube oil minimum pressure switch Lube oil maximum temperature switch Lube oil temperature sender Lube oil pressure sender Equipment: integrated fuel tank Integrated fuel tank capacity 50 L Integrated fuel tank capacity 120 L Integrated fuel tank capacity 350 L Integrated fuel tank capacity 800 L Leak proof tray sized for integrated fuel tank capacity Equipment: underground fuel tank 1.000 L underground storage fuel tank with double wall 2.000 L underground storage fuel tank with double wall 3.000 L underground storage fuel tank with double wall 5.000 L underground storage fuel tank with double wall 10.000 L underground storage fuel tank with double wall 15.000 L underground storage fuel tank with double wall Equipment: outdoor single-wall tank 1.000 L outdoor storage fuel tank with single wall and 2.000 L outdoor storage fuel tank with single wall and 3.000 L outdoor storage fuel tank with single wall and 5.000 L outdoor storage fuel tank with single wall and 10.000 L outdoor storage fuel tank with single wall and

15.000 L outdoor storage fuel tank with single wall and Automatic refilling system Equipment: outdoor double-wall tank 1.000 L outdoor storage fuel tank with double wall 2.000 L outdoor storage fuel tank with double wall 3.000 L outdoor storage fuel tank with double wall 5.000 L outdoor storage fuel tank with double wall 10.000 L outdoor storage fuel tank with double wall 15.000 L outdoor storage fuel tank with double wall Equipment: protections Heating parts guard Moving parts guard Equipment: assembly Alternator assembled by flexible joint Anti-vibration mountings Flexible coupling disc Screwed steel frame Welded steel frame Equipment: excitation system Self-excited Separately-excited by P.M.G. Anti-condensation heater Tropicalization treatment Winding leads 1-phase sensing input 2-phase sensing input 3-phase sensing input Equipment: drive-in-parallel CT for parallel running with other gensets cosphi regulator

Technical specifications are subject to change without notice. Consult your local PRAMAC representative for more information.