Stationary batteries with modified tubular electrodes

Similar documents
Features and Benefits

OPzV Batteries. Technical Data

Reserve Power OPzV Batteries

Reserve Power OPzV Batteries

Stationary Batteries OPzS Cells

FIAMM. stationary batteries J^^^^^^^IRP^ FIAMM

SPA AGM VRLA batteries

Tubular Gel (OPzV) Batteries. Stationary & Renewable Energy Applications

Tubular Flooded (OPzS) Batteries

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

Low maintenance TAB OPzS vented stationary batteries

OPzV Batteries for Stationary Applications

Tubular Flooded (OPzS) Batteries

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

Modular Max AGM Range VRLA

[Charge] [Lead dioxide] [Lead] [Sulfuric acid] [Lead sulfate] [Lead sulfate] [Water]

EcoSafe EOPzV. Operation Guide for Solar Applications

6 & 12 Volt Monobloc. Haze Battery Company Ltd

PERFORMANCE SPECIFICATIONS

OPzV Batteries. for Stationary Applications

OPzV Batteries. for Stationary Applications

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

RANGE SUMMARY OPzS Optima

FLOODED (VLA ), SEALED (VRLA), GEL, AGM TYPE, FLAT PLATE, TUBULAR PLATE: THE WHEN, WHERE, AND WHY. HOW DOES THE END USER DECIDE ON THE BEST SOLUTION?

Batteries for Renewable Energy Applications

Battery Performance Specifications

BAE Batterien GmbH. Untertitel. TITEL batteries since 1899 made in Berlin. Distribution only by express authority of BAE Batterien GmbH

Industrial Batteries / Network Power. Classic OCSM.»Exceptional combination of high power, long life and excellent cycling capability«

Industrial Batteries / Network Power. Sprinter P / XP.»Reliable power for increased ed security«

Standby Products SD-SDH. series. Technical Features. Applications. Product Features

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

Valve regulated sealed industrial battery. HAGEN OPzV

Industrial Batteries / Network Power. Marathon M-FT.»AGM modular power«

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

2 Volt AGM Range. Haze Battery Company Ltd

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

SD / SDH. Applicable Standards. Applications and Key Benefits. FIAMM Manufacturing. - Technical Features

Technical Manual. An Invensys company

BAE SECURA Product Programme Stationary Batteries ENERGY FROM BATTERIES BAE

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Industrial Batteries / Network Power. Marathon L / XL.»More energy for safer storage«

Industrial Batteries / Network Power. Sprinter P / XP.»Reliable power for increased security«

PRODUCT GUIDE Publication No: EN-SBS-PG-001 February 2003

Pure Lead-Tin Technology

Power to keep you on the move

CELLYTE 12 PLF & 12PLT Range

6 & 12 Volt Monobloc GEL Range

Batery SERIES. VALVE REGULATED LEAD ACID BATTERies INFINITE POWER. Mission Critical Applications. All Battery Range

Applications. EMC tested

Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications

Battery Storage Systems

SECTION A Division of Exide Technologies

Haze Battery Company Ltd

SEC. MICROLYTE +Plus. Industrial Battery Co. Supplied Worldwide by: Visit our website on Features. Application

FAT. FAT Battery Range FIAMM.COM

PowerSafe OPzV Operation Guide for Solar Applications

Renewable Energy Storage Solutions

Prepared for 7 x 24 Exchange

Tubular Gel Technology For Solar Applications

SECTION TECHNOLOGIES I NDUSTRIAL E NERGY

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. Gelled Electrolyte Range. Monobloc

Battery. Student booklet

Motive Power. Higher Energy. Faster Charging. Extreme Conditions. 24h

PowerSafe OPzV Operation Guide for Solar Applications

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar

Industrial Batteries / Network Power


CYCLON SELECTION GUIDE

General Catalogue VRLA-AGM, VRLA-GEL and Stationary Batteries

Industrial Batteries / Network Power. Classic OPzS.»Proven high reliability energy storage for critical applications«

FUEL CELLS AND BATTERIES LECTURE NO. 9

Better Efficiency with Electrolyte Circulation

Industrial Batteries / Network Power. Classic OGi.»Superior performance for

Product Guide. An Invensys company

PbSO 4 + 2H2O + PbSO4 Lead Sulfate Positive Plate Active Material

Technical Manual. E-trek DM Series SHANDONG SACREDSUN POWER SOURCES CO.,LTD

Pallet Pro On-Board Power System and 6 Volt Group 27 Deep Cycle Bloc Batteries GB A Division of Exide Technologies

PS-Series General Purpose Batteries

SVTX AGM VRLA batteries

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

SECTION

Nominal Voltage. Capacity (C20)

Pb battery. Chemical equation: Pb+2 H 2 SO 4. + PbO 2 <charge. 2 PbSO 4 +2 H 2. discharge>

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Haze Battery Company Ltd

BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V. DP Electronics e.k (Deutsche Power Co., Limited)

SECTION A Division of Exide Technologies

Vented fibre structure Nickel Cadmium batteries for stationary systems

Sealed Rechargeable VRLA Batteries

V R L A HI-PERFORMANCE BATTERIES

Maintenance Free Sealed Lead Acid Batteries

Deep Cycle AGM Range VRLA

Valve regulated Batteries for Stationary Applications. HAGEN dc plus. An EXIDE Company

Transcription:

VDR OPzS Stationary batteries with modified tubular electrodes CERTIFIED WITH ISO 9001:2009

VDR OPzS stationary batteries produced in accordance with Calcium Plus technology and are intended for wide range of application. PPICTION: VDR OPzS batteries are applied as uninterrupted power supply at electric power stations and substations, communications and telegraph centrals and for other types of uninterrupted energy supply equipment at the constant recharge and charge discharge modes. dvantages of Calcium Plus technology (calcium alloying of negative electrode): 2,5 times less electrolyte evaporation; higher corrosion resistance of electrodes; overcharge resistance; low battery self discharge. at charging with higher voltage. Plugs are applied as extra means of ignition prevention (to increase safety) and catalytic recombination (to decrease water loss). Connectors: flexible or made of solid copper. Temperature range: from +5 to Electrolyte: water solution of sulfuric acid with density of +45 С (+20 С is preferable). Installation: all standard DESIGN: 1.245±0.005 g/cm3 Positive electrode, tubular Pole terminal: sealed pole and on isolated racks are plate filled with unique active terminal with solid brass bush for acceptable. material PUDERTEC providing bolt M. higher cell lifetime along with required electrical characteristics. Negative electrode pasted grid plate made of patented lead calcium tin alloy providing long battery service life. Separation: electrodes are separated by special high porous separator made of polymeric materials. Container and lid: made of impact plastic that enables easy service and mechanical stability during all service life. Both cell sides have marking of minimal and maximum electrolyte levels. installations in vertical position Service life: not less then 20 Ventilation plugs: plugs design years at buffer mode and proper prevents electrolyte splashing even operation.

Battery type BTTERIES SPECIFICTIONS Battery dimensions, mm W H C Weight without electrolyte, not more, kg Weight with electrolyte, not more, kg 2 ОPzS 0 5±1 206±1 420±5 8±1 8,5 13,5 3 ОPzS 150 5±1 206±1 420±5 8±1 11,0 16,0 4 ОPzS 200 5±1 206±1 420±5 8±1 14,0 19,0 5 ОPzS 250 125±1 206±1 420±5 8±1 16,5 22,0 6 ОPzS 0 145±1 206±1 420±5 8±1 20,5 26,5 4 ОPzS 280 125±1 206±1 505±5 8±1 18,0 27,0 5 ОPzS 350 125±1 206±1 505±5 8±1 21,0 29,0 6 ОPzS 420 145±1 206±1 535±5 8±1 24,5 33,5 7 ОPzS 165±1 206±1 535±5 8±1 27,5 38,0 6 ОPzS 145±1 206±1 7±5 8±1 34,0 47,0 7 ОPzS 700 193±1 215±1 7±5 8±1 42,0 60,0 8 ОPzS 800 193±1 215±1 7±5 8±1 80±1 46,5 63,5 9 ОPzS 900 235±1 215±1 7±5 8±1 1±1 50,0 74,0 ОPzS 00 235±1 215±1 7±5 8±1 1±1 54,5 77,0 11 ОPzS 10 277±1 215±1 7±5 8±1 1±1 61,0 88,0 12 ОPzS 1200 277±1 215±1 7±5 8±1 140±1 65,0 91,0 12 ОPzS 1500 277±1 215±1 840±5 8±1 140±1 84,0 119,0 14 ОPzS 0 400±1 215±1 840±5 8±1 1±1 96,0 147,0 15 ОPzS 1875 400±1 215±1 840±5 8±1 1±1 2,0 152,0 16 ОPzS 2000 400±1 215±1 840±5 8±1 1±1 7,0 156,0 18 ОPzS 2250 487±1 215±1 840±5 8±1 1±1 125,0 190,0 20 ОPzS 2500 487±1 215±1 840±5 8±1 1±1 136,0 200,0 24 ОPzS 00 585±1 215±1 840±5 8±1 140±1 166,0 240,0 MIN DIMENSIONS ND TERMINS OCTION 2 OPzS 0, 3 OPzS 150, 4 OPzS 200, 5 OPzS 250, 6 OPzS 0, 5 OPzS 350, 6 OPzS 420, 7 OPzS, 6 OPzS, 7 OPzS 700 8 OPzS 800, 9 OPzS 900, OPzS 00, 11 OPzS 10, 12 OPzS 1200, 12 OPzS 1500, 14 OPzS 0, 15 OPzS 1875, H W

DISCHRGE CHRCTERISTICS OF OPzS SERIES (Constant Current, ) Cell Type 2 OPzS 0 3 OPzS 150 4 OPzS 200 5 OPzS 250 4 OPzS 280 6 OPzS 0 5 OPzS 350 6 OPzS 420 7 OPzS 6 OPzS 7 OPzS 700 8 OPzS 800 9 OPzS 900 OPzS 00 11 OPzS 10 12 OPzS 1200 12 OPzS 1500 14 OPzS 0 15 OPzS 1875 Discharge Time to 1.8 Vpc, min 15 60 90 120 180 240 0 480 94,2 92,3 76,3 56,7 40 33,5 25,7 21,4 18,3 12,9,8 141 138 114 85 60 50,2 38,5 32,1 27,4 19,4 16,2 188 185 153 113 80 67 51,4 42,8 36,6 25,8 21,6 236 231 191 142 0 83,7 64,2 53,5 45,7 32,3 27 265 259 159 112 93 72 60 51,3 36,2,3 283 277 229 170 120 0 77,1 64,2 54,9 38,7 32,4 0 294 252 196 140 119 92,7 76,2 65,1 46,4 39 360 353 3 235 168 142 111 91,5 78,1 55,7 46,8 420 412 353 274 195 166 1 7 91,1 64,9 54,6 423 417 377 6 224 193 154 126 7 75,1 62,9 493 486 440 357 262 225 179 147 125 87,6 73,4 564 555 503 408 299 258 205 168 143 0 83,9 634 625 566 460 337 290 2 189 161 113 94,4 705 694 629 511 374 322 256 2 178 125 5 775 764 692 562 412 354 282 232 196 137 115 846 833 755 613 449 386 7 253 150 126 914 896 856 725 542 472 375 312 268 188 157 66 45 998 845 632 551 438 363 312 219 184 1142 1120 70 906 677 590 469 389 335 235 197 1218 1195 1141 966 722 6 500 415 357 250 2 1370 1344 1284 87 812 708 563 467 402 282 236 1523 1493 1426 1208 903 787 626 519 446 313 262 1827 1792 1712 1449 83 944 751 623 535 376 315 CPCITY vs TEMPERTURE CPCITY vs DISCHRGE MODE 120% 1% 0% 0% vailable capacity, % 80% 60% 40% vailable capacity, % 90% 80% 70% 60% 20% 50% 0% -40 - -20-0 20 40 50 60 40% 1 2 3 4 5 6 7 8 9 Temperature, C Discharge time, hrs

DISCHRGE CHRCTERISTICS OF OPzS SERIES (Watts per Cell) Cell Type Discharge Time to 1.8 Vpc, min Время мин 15 60 90 120 180 240 0 480 22OPzS OPzS0 0 172 143 7 76,2 64 49,3 41,1 35,2 24,9 20,9 33OPzS OPzS150 150 263 257 161 114 96 73,9 61,7 52,8 37,3 31,3 44OPzS OPzS200 200 350 286 152 128 98,6 82,2 70,4 49,8 41,7 55OPzS OPzS250 250 438 429 357 268 191 160 123 3 88 62,2 52,1 44OPzS OPzS280 280 481 401 1 179,4 138 115 99 70 58,5 OPzS0 0 525 515 429 322 229 192 148 123 6 74,7 62,6 55OPzS OPzS350 350 555 545 471 369 265 226 177 146 125 89,3 75,2 OPzS420 420 667 654 565 443 318 271 213 150 7 90,2 77OPzS OPzS 778 763 659 516 371 316 248 205 125 5 OPzS 789 778 707 578 427 368 294 242 206 145 121 77OPzS OPzS700 700 921 908 825 674 498 4 283 240 169 142 88OPzS OPzS800 800 52 37 943 771 569 491 392 323 274 193 162 99OPzS OPzS900 900 1184 1167 61 867 640 553 441 363 9 217 182 OPzS 00 1315 1297 1179 963 711 614 404 241 202 11 OPzS 10 1447 1427 1297 60 782 678 539 444 378 265 222 12 OPzS 1200 1578 1556 1415 1156 853 737 588 484 412 289 243 12 OPzS 1500 1676 1645 1576 1345 17 712 593 511 360 2 14 OPzS 0 1955 1920 1838 1569 39 8 692 596 420 353 15 OPzS 1875 2095 2057 1969 1681 1271 1113 741 639 450 378 2234 2194 21 1793 1356 1187 949 791 681 480 403 2514 2468 2363 2017 1525 1335 68 767 540 454 2793 2742 2626 2241 1695 1484 989 852 504 3352 3291 3151 2690 2034 1781 1424 22 720 605 SERVICE IFE OF OPzS BTTERY 9000 Unique combination of technology Calcium Plus and multi fractional filling of positive electrode enables improved electrical characteristics and higher service life of the battery. Cycles quantity 8000 7000 batteries VDR OPzS 0 5000 4000 conventional batteries 00 2000 00 0 20 40 50 60 Depth of Discharge, % 70 80 90