SNAP ACTION SWITCHES type SAS-00, SAS-03

Similar documents
S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

S870, S970 Series. Snap-action switches. Positive opening operation Self-cleaning contacts Catalogue D70.en

FL series position switches

Position switches FD series

LK Position Switches TECHNICAL DATASHEET.

Microswitches MK series

General_technical_data Series

Switches with manual reset

Microswitches M series

Position switches FC series

Safety rope switch with reset for emergency stop

Microswitches MK series

7 Switching Equipment and Control Devices

Floor and fine adjustment switches

Safety rope switches with reset for emergency stop

3SE3 1 SIGUARD Position Switches

Safety switches for hinges

Position switches FR series

SFS-UFS Single Foot Switches

Safety rope switch without reset for simple stop

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Position switches FR series

General_technical_data Series

Prewired position switches FF series

Han ES Press. Features. Description. Removal of conductor. Size 6 B - 24 B

FOOT SWITCHES

General_technical_data Series

BETA Switching Switches and Light Indicators

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

l Snap-Action Switches

Safety switches for hinged doors

Safety switches with separate actuator

Single foot switches PX and PA series

Safety switches for hinged doors

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Single foot switches - PX and PA series

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Special Purpose Fuses

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

l Snap-Action Switches

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Single foot switches PX and PA series

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Fuse switch disconnectors

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

Prewired position switches FF series

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

AF40... AF96 3-pole contactors Technical data

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

S880 Series Snap-action switches with positive opening operation and self-cleaning contacts Catalogue D80.en

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Safety switches with separate actuator

Datasheet - MV8H Y

Microswitches MK Series

K50H004UP cam changeover switch - 4-pole A - screw mounting

vertical fuse switch disconnectors

TMC 91H is now TMC 60 C Series

Varius SUMMARY OF MODELS

K30H001YP cam star-delta switch - 3-pole A - screw mounting

W Datasheet: DIN Rail Contactors, series AMPARO

Miniaturized limit switches

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

High Performance Thermal-Magnetic Circuit Breakers 410/520/

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Fuse switch-disconnectors

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Technical data. Standards: IEC/EN BG-GS-ET-15

MINIATURE CIRCUIT BREAKER

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

General_technical_data Series

HL (AZH) LIMIT SWITCHES

Safety switches with solenoid and separate actuator

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

Miniature Circuit Breaker

Description. Positive safety relays

Safety Limit Switch

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Limit Switches - Limit Type (PS21L) Metal Body IP66

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Limit Switch - Prewired Type Metal Body

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Application Mini Contactors for Motors and Resistive Loads

SG-B1 SERIES / SG-A1 SERIES

Position Switches Series 8074/2

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Fuse switch disconnectors

Technical Information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

SERIES MP720 & DERIVATIVES

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Transcription:

EN 60947-5- SNAP ACTION SWITCHES type SAS-00, SAS-03 SAS 00 and 03 Series snap-action switches have one NO and one NC contacts. The change of the switching position is realized by the mechanism, which ensures rapid switching and gives the possibility for switching of high currents. The electric circuit interrupts by double break. The snap-action switches are in the procession of a mechanism, which in case of short-circuit breaks forced the welded normally closed contact. The contact system is placed in a small design made of transparent light blue plastic material with high electrical and mechanical characteristics. The contact system in various versions is actuated directly or through lever system. APPLICATION Limit control track switches; command controllers and reversers for battery-operated and diesel trucks; electric driving; automatical devices; transport means; household appliances; non inductive and low inductive resistance furnaces; DC magnet and contactor control TYPE CHARACTERISTIC SAS xx x x xx type / contact system SAS / N.O. and (or) N.C. ; contact bridge protection of terminals/ material of the actuator 00 IP 00 / metal actuator 03 IP 00 / metal actuator and flat tabs (6.3 x 0.8 mm) DIN 4647, preferably with insulated cable sleeves actuating and front mounting b push button с push button, two mounting brackets cl push button, two mounting brackets, one of them slotted а roller lever, two mounting brackets аl roller lever, two mounting brackets, one of them slotted d roller lever, two mounting brackets, one of them angled 90 o е roller lever, no mounting brackets fa two rollers lever, two mounting brackets fe two rollers lever, no mounting brackets *other combinations are possible actuation force /with push button/ /with roller lever/ standard - 3N - N - standard strengthened - 3,5N 3,5 stronger - 9N 9 mounting - without rivet, mounting hole 4,3 mm r with rivet, mounting hole 3, mm SAS 03a Article No. EXAMPLES 68003 SAS 00a SAS 00c SAS 00d SAS00fa Article No. Article No. ArticleNo. 68000 680030 680040 Article No. 68000 6800 68003 68004 6800 68003 68004

SAS 00b SAS 00br SAS 00e SAS 00er Article No. Article No. Article No. Article No. 68000 68005 680050 680055 6800 68006 68005 680056 6800 68007 68005 680057 TECHNICAL DATA Standard SAS 00, SAS 03 /b, c/ SAS 00, SAS 03 /a, d, e/ Contact configuration EN 60947 N.O. and (or) N.C. ; contact bridge Conventional thermal current I t. EN 60947 6 А Rated insulation voltage U i, EN 60947 400 V Pollution degree EN 60947 3 Rated impulse withstand voltage U imp EN 60947 4 kv Utilization category EN 60947 BREAKING CAPACITY at: Value Symbol Measure DC AC - 5, 30 VAC /.6A DC - 3, 0 VDC / A Contact material -- Silver (Ag) N.C. Contact force EN 60947 0,70 N min. Acuation travel --.5 mm 3.40 mm Actuation force (standard) EN 60947 3 N min. N min. Actuation speed EN 60947 mm/s min. Mechanical life, cycles EN 60947 0 7 Wire connecting type -- multi-core 0.75.5 mm Max.number of wires for one terminal -- pcs. Tightening torque of terminal screws EN 60947 0.9 Nm Protection degree EN 6059 contact system - IP 40 terminals - IP 00 Casing material -- transparent light blue polycarbonate Sea level EN 60947 up to 000 m Operating conditions -- normal fire hazard Ambient temperature EN 60947-40 О C + 85 О C Weight -- 30 40 g АС DC - 3 AC - AC - 5 Rated operating voltage Ue V 4 40 0 30 Rated operating current Ie A 8 4.5 0,6 Breaking capacity cycles pcs. 0 6 0 6 0 6 0 6 0 6

ACTUATION FORCE RELEASE FORCE SWITCH WITH ROLLER LEVER ACTUATED BY CAM DISK F 8, 85±0, 5 F 7, 80±0, 5 6, 60±0, 5 0±0,35 max. 3, ±0, 8,4 ±0, 35 6,6 ±0, 35 F[N] 3 5 F[N],55,76,57,7 0,93 0,83,7,08 0,60 0,55 0 x[mm] 0 x[mm] TECHNICAL DATA FOR CONTACT SYSTEM Actuator position SAS 00 /b, c/ SAS 00 /a, d, e/ SAS-00 fa Dimension х Dimension х Dimension х Free position 8.85 mm ± 0.5 mm 0.00 mm ± 0.35 mm 6.50 mm + 0.5 mm Operating position 6.60 mm ± 0.5 mm 6.60 mm ± 0.35 mm 5.50 mm ± 0.35 mm Release position 7.80 mm ± 0.5 mm 8.40 mm ± 0.35 mm 4.00 mm ± 0.35 mm Total travel position 5.65 mm ± 0.5 mm 3.0 mm ± 0.5 mm 6.50 mm ± 0.50 mm OVERALL AND CONNECTING DIMENSIONS SAS 00a SAS 00b 3

SAS 00с SAS 00br SAS 00d SAS 00e SAS 00al SAS 00er SAS 00fa SAS 00fe 4

SAS 03a 8 0,5 7. 8 9 max. 3.5 8 x 4.3 x 67 ЕLECTRICAL CONNECTION * SCREW-TYPE TERMINALS - Connected to the snap action switches wires can be single and multiple 0,75 mm to,5 mm (AWG 8...4). At mounting of ferrules the maximum wire gauge is.5mm² (AWG 6). - Two conductors max can be clamped per terminal with the same wire gauge. - Wire insulation must be flush with the clamping unit. - Tightening torque of terminal screws should be within 0,5 Nm... 0,9 Nm. * FLAT QUICK-CONNECT TERMINALS (for SAS 03) - Use flat tabs 6,3 mm x 0,8 mm (DIN 4647), preferably with insulated cable sleeves. - If necessary, the terminals are provided with a forming point where the flat tab can be angled by < 90. MECHANICAL FASTENING * FRONT MOUNTING - At SAS 00 b by way of the nut retainers (M3), inserted in the housing of the snap action switch. Tightening torque must be max. 0,9 Nm. - At switches with roller levers (SAS 00 a, SAS 00 c и SAS 00 d) - by way of the mounting brackets. * GANGING (lateral mounting) for SAS 00 e and SAS 00 b - Without rivets - through the two transversal bore holes with 4 mm screws or bolts. - With rivets - through the two transversal bore holes with 3 mm screws or bolts. - Between the bolts head and snap action switches place feder washer. - In order to safeguard clearance and creepage distances it is necessary to use insulating plates when ganging or mounting switches on uninsulated surface. ATTENTION:. At mechanical mounting make sure to have fixing points!. The values for maximum tightening torque must not be exceeded. 3. Be sure that after mounting, the wires are free of mechanical tension! 4. When using of screw-retaining varnish, cleaning agents, adhesives etc., they must be compatible with polycarbonate. 5