Western Power s list of exemptions from compliance from Technical Rules granted after 1 July 2007.

Similar documents
List of exemptions from compliance with the Technical Rules granted by Western Power after 1 July 2007

Exemptions currently in force

DESCRIPTION OF REQUIREMENTS FOR GENERATION SYSTEMS SEEKING TO PROVIDE SYSTEM RESTART SERVICES

Jemena Electricity Networks (Vic) Ltd

Guidelines for connection of generators:

CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

Electricity Industry Code Minimum Service Standards & Guaranteed Service Levels Quarterly Report July September 2008

ELECTRIC SERVICE RATE SCHEDULES. Effective November 1, 2017

Utilities (Technical Regulation) (Electricity Transmission Supply Code) Approval 2016 (No 1)*

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Street Address. City-Village-Township

Reactive Power Requirements and Financial Compensation. Addendum to Draft Final Proposal

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

Guideline for Parallel Grid Exit Point Connection 28/10/2010

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after February 1, 2019.

Street Address. City-Village-Township

FINAL FACILITY STUDY. 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1. September 10, 2010

POWER SYSTEM OPERATING INCIDENT REPORT SIMULTANEOUS TRIP OF 5A6 MT PIPER BANNABY 500 KV LINE AND MT PIPER NO. 2 UNIT ON 9 FEBRUARY 2012

Georgia Transmission Corporation Georgia Systems Operations Corporation

Consolidated Edison Company of New York, Inc.

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after January 1, 2014.

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

Power Supply Cost Recovery

February 13, Docket No. ER ; ER Response to Request for Additional Information

Decision (Errata) Access Pipeline Inc. Errata to Decision Temporary Generation at Smoky Lake Pump Station.

Feasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation

NZQA unit standard version 8 Page 1 of 5. Apply and remove earths from conductors on electricity supply networks

Procurement Plan. Eskom Holdings SOC Limited. Eskom Investment Support Project

SP Distribution plc. and XXX

Technical Series, Edition 16

POWER SYSTEM OPERATING INCIDENT REPORT TRIPS OF YALLOURN W POWER STATION UNITS W1 AND W3 ON 14 NOVEMBER 2012

Accidental Islanding of Distribution Systems with Multiple Distributed Generation Units of Various Technologies

Standard Battery Energy Storage System (BESS) Connection Arrangements

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

POWER SYSTEM INCIDENT REPORT: TRIP OF NO 1 AND 2 NEW OSBORNE 66 KV BUSBARS ON 26 SEPTEMBER 2010

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

UK Power Networks Use of System Charging Methodology

Large General Service Time-of-Use Storage Program

SECTION D RATE SCHEDULES

The Smarter Network Storage Project

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document

Date Event or Holiday :Sun, 2:Mon North Orchard Delong Preschool North Orchard Delong Preschool

New 115 kv Disconnect Switches at Bloomsburg MTS

Company Directive STANDARD TECHNIQUE: SD4O/1. Standard HV Connection Arrangements

POWER SYSTEM OPERATING INCIDENT REPORT MULTIPLE CONTINGENCY EVENT IN NORTH WEST TASMANIA ON 6 APRIL 2012

Functional Specification Revision History

DEPARTMENT OF TRANSPORTATION. National Highway Traffic Safety Administration. [Docket No. NHTSA ]

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

Seabrook Substation Reliability Improvement Project

TRANSMISSION PLANNING CRITERIA

October 17, Please contact the undersigned directly with any questions or concerns regarding the foregoing.

2018 Annual Progress Report to WECC Pacific Gas and Electric Company

Umatilla Electric Cooperative Net Metering Rules

This qualification has been reviewed. The last date to meet the requirements is 31 December 2020.

Impact of Distributed Energy Resources on Transmission System Reliability

Ukujima Photovoltaic Park 400 MW Stable Integration of a 400MW Photovoltaic Farm into the Japanese Power System Challenges and Chances

Essential Reliability Services From PV Plants

Status of PNM s Completed Transmission Construction Projects 11/30/2017

Interconnection Feasibility Study Report GIP-023-FEAS-R1. Generator Interconnection Request # MW Wind Generating Facility Inverness (L6549), NS

FOR IMMEDIATE RELEASE

Draft Agenda. Item Subject Responsible Time. 4. GAS INFORMATION SERVICES PROJECT IMO 10 min. 5. OPTIONS FOR GAS BULLETIN BOARD SYSTEM IMO 15 min

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Elbert County 500 MW Generation Addition Interconnection Feasibility Study Report OASIS POSTING # GI

Guideline for Using IEEE 1547 for Solar PV Interconnection Page 1

Smarter Network Storage UK first multi-purpose application of grid scale storage. Dr. Panos Papadopoulos, PhD, CEng

Decision D ATCO Electric Ltd. Decommissioning of Transmission Line 6L79. October 18, 2016

Research Brief. Impact of higher 25kV fault currents. T873 - October Background. Aims

National Grid. Narragansett Electric Company INVESTIGATION AS TO THE PROPRIETY OF COMPLIANCE TARIFF CHANGES. 2 nd Amended Compliance Filing

Interconnection Feasibility Study Report GIP-226-FEAS-R3

Contents. 1 Introduction. 2. Advisory and Information Systems. 3. Supply. 3.1 Quality of Electric Supply. 3.2 Interference with other Customers

SUBJECT: Russell Hill Subway Train Accident Of August 11, 1995 Due Diligence Checklist Update

PUBLIC SERVICE COMMISSION CHARLESTON

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

Rail Safety and Standards Board

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

No. CONSUMER PRICE INDICES. Information bulletin. Moscow 2019

100 MW Wind Generation Project

Export limits for Embedded Generators up to 200 kva connected at Low Voltage

Emerald Reactive Support Alternative Solution Expressions of interest

FOR IMMEDIATE RELEASE

Grid Integration Costs: Impact of The IRP Capacity Mix on System Operations

SCHEDULE NO. ACG33 NET METERING SERVICE

Alberta Electric System Operator Needs Identification Document Application. Mowat 2033S Substation

The Commonwealth of Massachusetts

An Introduction to Completing a NERC PRC Study

Group 3: Pricing from 1 April 2018 and load management

SERVICE CLASSIFICATION NO. 7. Also optional for: This option is not available to Service Classification No. 2 customers, effective December 3, 2002.

POWER SYSTEM OPERATING INCIDENT REPORT LIGHTNING STRIKES IN TASMANIA AND PACIFIC ALUMINIUM POTLINE LOAD REDUCTIONS 21 MARCH 2013

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Interconnection System Impact Study Report Request # GI

FOR IMMEDIATE RELEASE

APPENDIX I: Description and Functional Specifications for Transmission Facilities Eligible for Competitive Solicitation

August 2018 MLS Statistical Report

UNITIL ENERGY SYSTEMS. INC. CALCULATION OF THE EXTERNAL DELIVERY CHARGE

Annex to technical regulation for thermal plants above 11 kw

Siemens Power Academy Transmission & Distribution North America January- December 2011 Course Schedule

PSNH INTERCONNECTION REQUEST

Brion Energy Corporation

Transcription:

Western Power s list of exemptions from compliance from Technical Rules granted after 1 July 2007. No Date of Exemption To whom Exemption was granted Clause to which Exemption has been granted Concise details of the Exemption (including reason for granting the exemption) 1 16 January 2008 Newgen Neerabup Unit 1 2 16 January 2008 Newgen Neerabup Unit 1 3 29 January 2008 Bluewaters Power Station Unit 2 3.3.3.1(a) 3.3.3.3(b) 3.3.3.5 Modified reactive power capability: 0.8 Lagging 101.3 MVAr 0.9 Leading 68.5 MVAr Financial contribution for the shortfall in reactive power capability, pursuant to clause 3.3.3.1(d). Modified off-nominal frequency capability: 47.0 47.5 Hz 20 seconds 47.5 51.5 Hz continuous 51.5 52.0 Hz 20 seconds 52.0 52.5 Hz 0 seconds Constrained operation for SWIS load below 1960MW. Modified load ramping rates: The requirement to respond at a rate of 5% of nameplate rating per minute is modified to require the power station to respond by increasing output by 10 MW in the first 10 seconds and then after one minute increasing output at a rate of 3% of nameplate rating per minute. File#: NAC/77/10(41)V1 1

Identical to exemption for Unit 1, with System Management s acceptance. 4 4 September 2009 Collgar Wind Farm 3.3.3.10(c)(1) Modified switchyard arrangements: Connection via two circuits and no circuit breakers in the generator s switchyard. Deemed to be technically and commercially optimal arrangement. Financial contribution made for the switchyard. 5 7 October 2009 Collgar Wind Farm 2.2.10 Modified overvoltage performance requirements: The overvoltage capability curve proposed by the generator applies in lieu of that of clause 2.2.10, Figure 2.2. The connection point site-specific overvoltage performance requirements (as assessed by Western Power) are met by the generator s overvoltage capability. 6 10 June 2010 Tesla Corporation: Harris Road, Leeming Road, Deepdale Road and Kemerton 10.0 MW Power Stations 3.3.1(c) Exemption from large generator requirements: Assessment permitted under clause 3.6 for small generators. Initial misinterpretation of the applicable requirements (by both Western Power and Tesla) and advanced stage of these projects at the time the correct interpretation became apparent. File#: NAC/77/10(41)V1 2

7 25 October 2010 Grasmere Wind Farm 3.2.2 8 23 March 2011 Synergy 3.7.8.3(b) Modified switchyard arrangement: Utilisation of Western Power feeder circuit breaker to de-energise wind farm in lieu of wind farm main switch. Integration into Albany zone substation and existing voltage control scheme via the 3 rd identical 22kV (wind farm) feeder is deemed the best solution. Additional cost of technical compliance would increase operational complexity and not provide any tangible benefit. Financial contribution made for the switchyard. Inspection and testing requirements waived, pursuant to the Office of Energy s Final Outcomes Report and subsequent recommendation to change the Technical Rules accordingly. 9 24 August 2011 Bluewaters Power Station Unit 2 10 23 Feb 2012 Extension Hill Pty Ltd (EHPL) transmission load 3.3.3.1 3.2.2 Modified reactive power capability: For steady state voltages from 90.5% to 90% of the rated voltage at the connection point, the required reactive power absorption is at least the amount equal to the product of the rated active power output of the generation unit at nominal voltage and 0.441. The connection point site-specific reactive power absorption capability is acceptable to Western Power and System Management. Modified switchyard arrangement for the initial EHPL single circuit connection: Utilisation of Western Power circuit breaker to de-energise transmission load. File#: NAC/77/10(41)V1 3

11 18 April 2012 Karara Power Pty Ltd (KPPL) transmission load 12 25 Sep 2012 Public Transport Authority City railway substation 13 6 Nov 2012 West Hills and Anderson wind farms 3.2.2 3.2.1(d)(2) 2.9.2(b) There is no benefit in these particular circumstances in requiring EHPL to install its own 330kV main switch at Three Springs terminal substation. Modified switchyard arrangement for the initial KPPL connection: Utilisation of Western Power circuit breakers to de-energise transmission load. There is no benefit in these particular circumstances in requiring KPPL to install its own 132kV main switch at Eneabba substation and 330kV main switch at Three Springs terminal substation. Two-phase connection accepted. The exemption is granted pursuant to clause 1.9.4(a), as the project was well advanced before 23 Dec 2011, being the commencement date for the revised Technical Rules (current) in which clause 3.2.1(d)(2) was materially changed. Duplication of protection: Two external generator protection relays supplied from a single voltage transformer (VT). In case of loss of the VT input to the protection relay, the VT supervision function of the relay will send the trip signal to disconnect the wind farm, which is considered as an acceptable functional alternative to duplication of the VTs. File#: NAC/77/10(41)V1 4

14 17 January 2013 Muja D 2.2.8(a) 15 23 January 2013 Inverter connected generation units 30 to 150kVA 2.2.8(b) 2.9.2(b) Modified damping of oscillations: The respective damping ratios must be at least 0.07 and 0.27. The performance (after automatic voltage regulator replacement) is at least equivalent to the previous performance. Duplication of protection: One (only) IEC60255 compliant external generator protection relay required in conjunction with protections integral to AS4777-2005 compliant inverters. The combined protection functionality provides a safe and reliable level of electrical protection for generator ratings of this size. File#: NAC/77/10(41)V1 5

16 14 Feb 2013 Grasmere Wind Farm 3.3.4.5(g), Table 3.2 (Rise time) 17 21 June 2013 Collgar Wind Farm, Stage 1 18 17 Sep 2013 Bluewaters Power Station Unit 1 & Unit 2 3.3.3.3(h)(2) Active power recovery time 3.3.4.4(b) Primary frequency control Modified rise time: The maximum permitted rise time is 3.0 seconds. There is no benefit in these particular circumstances in requiring modification of the integrated Albany wind farm control scheme (of which Grasmere is Stage 2) to achieve compliance. Modified active power recovery time: The maximum permitted recovery time is 1,000 milliseconds. No adverse effect on the network performance or other customers for the currently installed wind farm capacity outweighs the significant cost of compliance. Temporary exemption to complete repairs. End date 6 December 2013. Reasonable repair time frame agreed to suit both parties in order to bring the Units back into compliance. Last updated: 17 September 2013 For more details, refer to Western Power s web site: www.westernpower.com.au/aboutus/accessarrangement/technical_rules.html File#: NAC/77/10(41)V1 6