Installation. ABP-1C TouchTime Ablution System IMPORTANT! Table of Contents Rev. B; ECN E 2014 Bradley Page 1 of 5 10/6/2014

Similar documents
Installation Instructions

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain

Installation. MG-2 Infrared. Express Lavatory System - MG Series with Adaptive Infrared. Table of Contents

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain

Installation Instructions

Installation. SS-1N (bowl only) SS-1N Infrared SS-1N Battery Infrared SS-1N Touch Time. Table of Contents. Express Lavatory System SS-Series

Installation MF2933/TT

Installation HSL1/IR HSL1/BIR3. Ligature Resistant Single-Station Lavatory. Table of Contents

Installation MF2939/AST4

Installation MF2922/BIR3

WARNING NOTICE IMPORTANT

Installation Instructions

Installation Instructions

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

WARNING NOTICE IMPORTANT

Installation. SS-1N (bowl only) SS-1N/IR SS-1N/BIR3 SS-1N/TT. Express Lavatory System SS-Series. Table of Contents

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl

Installation S19-130BF Plastic Showerhead S19-130ABF Plastic Showerhead with Stainless Steel Shroud Drench Shower Vertical Supply Table of Contents

Installation Instructions

Installation Instructions

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Installation For Service Only

Parts & Service. Sentry Washfountain Discontinued Models Prior to February 1, SN " Semi-Circular, Floor-Mounted

Installation S Freestanding Drench Shower

Installation S19-120BF S19-120ABF. Plastic Showerhead. Plastic Showerhead with Stainless Steel Shroud Drench Shower - Horizontal Supply

Installation. S19284H (Eyewash) S19284J (Eye/Face Wash) Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash. Table of Contents

Installation S19-130BF S19-130ABF. Plastic Showerhead. Plastic Showerhead with Stainless Steel Shroud Drench Shower Vertical Supply

Installation S19-130BF S19-130ABF. Drench Shower - Vertical Supply. Table of Contents

Sentry Washfountain Parts & Service Guide

Installation. S19284HB (Eyewash) S19284JB (Eye/Face Wash) Barrier-Free Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash.

Installation Instructions

Installation S19-110BF. Freestanding Drench Shower

Installation S19-310LL. Combination Drench Shower and Eyewash

Installation S19-220BF. Wall-Mounted Eyewash

Installation S19-310F. Combination Drench Shower and Eyewash

Installation S19-220P. Wall-Mounted Eye/Face Wash. Table of Contents P Rev. P; ECN C 2012 Bradley Page 1 of 5 10/18/2012

Installation Instructions

OBSOLETE. Installation S19-325BF S19-325FBF S19-325PBF S19-325FPBF

Installation & Operation Manual

Installation S19-315BF S19-315FBF S19-315PBF S19-315FPBF

Owner s Manual SSCI. Classic Utility/Equipment Carts

Installation. E19-310AC Combination Drench Shower and Eye/Face Wash. Table of Contents

DISCONTINUED. Installation S19-310FSS. Stainless Steel Combination Drench Shower and Eyewash

Operation & Maintenance Manual

Installation. S19284HB (Eyewash) S19284JB (Eye/Face Wash) Barrier-Free Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash.

Installation Instructions

Installation S19-220ABF S19-220BBF. Wall-Mounted Barrier Free Eyewash with Plastic Bowl. Wall-Mounted Barrier Free Eyewash with Stainless Steel Bowl

Operation & Maintenance Manual

Ligature Resistant Stainless Steel. Basin Powder Coated White ADA Compliant

Installation Instructions

DISCONTINUED. Installation S19-310SS16. Stainless Steel Combination Drench Shower and Eyewash. Table of Contents

Installation S19-310NN. Frost-Proof Combination Drench Shower and Eyewash (18", 3', 4', 5' or 6' Bury Depth)

ETF-600 Sensor Operated Lavatory Faucet

Outdoor Bottle Fillers

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

Installation S19-220Y. Wall-Mounted Eyewash. Table of Contents

Installation Instructions

Installation Instructions

Installation Instructions

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

FREESTANDING FAUCET LS5B/LS5C INSTALLATION INSTRUCTIONS.

FOR TECHNICAL ASSISTANCE

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Vehicle Care ! WARNING: CLEANING PRODUCTS CLEANING THE EXTERIOR

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation. S19284H (Eyewash) S19284J (Eye/Face Wash) Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash. Table of Contents

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Installation. Bradley S19 210ss Pedestal Mounted Eye Face Wash Bradley S Eye Face Wash Hand or Foot S19-210SS. netzerotools.

INSTALLATION INSTRUCTIONS

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

WARNING NOTICE IMPORTANT

G SERIES - E TOUCH MIXER / TAP

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

INSTALLATION INSTRUCTIONS

Installation Instructions

Reading this manual. Preface

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

Parts & Service. Terreon Multi-Fount Washfountain Current Models After February 1, MF2922 Corner-Fount. MF2933 Tri-Fount

Installation S19-220HFP

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Installation Instructions

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

Installation Instructions

Installation Instructions / Warranty. Axor Citterio M 34315XX1

SPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET

SINK SPECIFICATIONS. ELONGATED DOUBLE BOWL Undermount Model VGR3218BL NOMINAL DIMENSIONS FEATURED MODELVGR3218BL 9" BOWL DEPTH

SAVE FOR CONSUMER INSTALLATION / OWNER S MANUAL. Includes: Tools: Mystic - Pull-Out Kitchen Faucet LKMY1041CR LKMY1041NK LKLFMY1041CR LKLFMY1041NK D 1

Installation Instructions / Warranty. Raindance Allrounder 28110XX1 Wall Outlet Adapter with Hose Connection 28108XX1

Transcription:

ABP-1C TouchTime Ablution System Rear Mount Table of Contents Pre- Information... 2 Rough-Ins... 2 3... 4 Cleaning and Maintenance... 5 Front Mount IMPORTANT! Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. THIS SIDE UP Packing List Separate parts from packaging and make sure all parts are accounted for before discarding packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction. Product warranties may be found under Products on our web site at www.bradleycorp.com. 215-1785 Rev. B; ECN 14-03-005E 2014 Bradley Page 1 of 5 10/6/2014 P.O. Box 309, Menomonee Falls, WI USA 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com

Pre- Information TouchTime The ABP-1CTT ablution system controls water flow at each station through the use of solid state circuitry. When the pushbutton is released, a signal is sent controlling the opening and closing of the fixture's solenoid valve. The valve then delivers water to the fixture for a preset length of time (60 seconds or 180 seconds). Recommended Heights Bradley ABP-1C TT can be installed at any height (see recommended height chart to the right). The heights listed are measured from finish floor to spout/head centerline. Components Material: All exposed parts are stainless steel or polished chrome-plated brass. Supply Inlet: The supply inlet to the solenoid or metering valve is 3/8" O.D. Comp (without supply stop) or 5/8" O.D. comp (with optional supply stop). Solenoid Valve: Solenoid valves have few moving parts making them less prone to mechanical failure. Supplies Required Recommended Ablution System Heights Ablution Types Ablution w/ seat Ablution w/ lavatory Ablution no seat Floor to /Head Centerline Height 74cm (29 in) 94cm (37 in) 150cm (59 in) 1/2" NPT piping, 1/2" NPT tempered water supply piping and 3/8" compression to 1/2" NPT adapter (required on models without optional supply stop) (4) 1/4"-20 wall anchors for spout/head, (2) #10 wall anchors for pushbutton assembly and (2) #10 fasteners for attaching valve block to interior of wall. Teflon tape or teflon pipe dope 110 VAC or 230 VAC power source for a 24 VAC Class II transformer (supplied by installer or available from Bradley as an option) 1 PRPK Transformer 269-645 4RT US (TYPE A) S83-134 1RT EU (TYPE F) 918-304 1RT UK (TYPE G) 918-303 1RT WARNING! The ABP-1C TT must be connected with a 24 VAC transformer. Connection to incorrect voltage will result in damage to the electronics and could result in personal injury. Refer to recommended ablution system heights shown above and rough-in images shown on page 3. A tempered water supply piping to the solenoid valve and spout/head as required for your installation. C Install (2) #10 wall anchors (supplied by installer) to secure pushbutton assembly. B wall openings for the spout/head and pushbutton as required for your installation. D Install (2) #10 screws (supplied by installer) to secure valve assembly to interior studs/wall. 2 10/6/2014 Bradley 215-1785 Rev. B; ECN 14-03-005E

Ø 6" Front Mount System Ø 4-1/4" (108mm) 2-1/2" (64mm) 5" (127mm) min. Button location independent of spout location SPSS SX 3-1/8" (80mm) Ø 3" (77mm) 1-1/4" (32mm) 1-3/4" (45mm) 1-5/8" (42mm) 13/16" (21mm) 1-1/8" (26mm) 1-11/16" (43mm) 5-15/16" Ø 1-1/2" (38mm) Refer to Height Table Ø 6" Rear Mount System SX 3-1/16" (78mm) 1-7/16" (37mm) Ø 4-1/4" (108mm) 5" (127mm) min. fixed from location (non-adjustable) SPSS 1-1/2" (38mm) max. wall thickeness 11" (279mm) 8-1/2" (216mm) 2" (51mm) Ø 3" (77mm) 6-1/2" (165mm) 7-1/2" (190mm) 8-1/2" (216mm) Refer to Height Table 13/16" (21mm) 1-1/8" (26mm) 1-1/2" (38mm) 5-7/8" (150mm) Ø 1-3/16" to 1-1/2" (30 to 38mm) Bradley 215-1785 Rev. B; ECN 14-03-005E 10/6/2014 3

2 DO NOT put the 24 VAC Class II transformer in the ablution room. Check local codes and ordinances for proper location and connection requirements. Conformity to local codes is the responsibility of the installer. WARNING! DO NOT turn the 24 VAC power on to your ablution panel until installation is complete. Verify that the electrical source to the fixture is 24 VAC. CAUTION! Connection of leads other than shown may cause permanent damage to the electrodes. A Install a 24 VAC Class II transformer in a remote location a safe distance from the ablution room. Connect the wire designated transformer to the wire on the transformer. Button to 24 VAC Power Source (black or brown wires to 24 VAC in any order B The connectors will only fit into the transformer wire. Connect the wire designated SOL-1 to the solenoid valve connectors. The wires can be connected to the solenoid in an order. C Front mount units: Secure the spout/head to the 1/4"-20 wall anchors (supplied by installer) using the screws provided. Rear mount systems with SPSS spout: Install and tighten nut. Rear mount system with SX spout: Install and tighten (2) 1/4-20 fasteners (supplied by installer) Optional /Head Optional PPK ABL Quick Connect (S45-2848) Optional Supply Stop (S27-340) 3/8" Compression D Secure the pushbutton to the #10 wall anchors (supplied by installer). E Connect F Connect the spout/head to valve (optional ABL spout quick connect kit (S45-2848) 3/8" comp end hose or optional supply stop to supply. (2) #10 Mounting Screws and Mounting Block (supplied by installer) Solenoid Valve to Button (the wires can be connected to the solenoid valve in any order) G Turn on the water supply to the ablution and check for leaks. H Turn on the 24 VAC power to the ablution and press the pushbutton several times to purge air from the lines. 4 10/6/2014 Bradley 215-1785 Rev. B; ECN 14-03-005E

Cleaning and maintenance instructions for stainless steel Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particularly under corrosive conditions, is essential. Always start with the simplest solution and work your way toward the more complicated. Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia. Apply the cleaning solution per the manufacturer s instructions and always use a soft cloth or sponge to avoid damaging the finish. Stubborn Stains: To remove stains from stainless steel use a stainless steel cleaner and polish such as Ball stainless steel cleaner or a soft abrasive. Always follow the manufacturer s instructions and apply in the same direction as the polish lines. /Head: If the spout/head delivers an uneven spray, remove the spout/head from the unit, disassemble, and remove foreign matter. Then reassemble spout/head and reinstall into unit. CAUTION! Never use ordinary steel wool or steel brushes on stainless steel. Always use stainless steel wool or stainless steel brushes. Special Situations for Material Fingerprints and Smears: To remove fingerprints or smears use a high quality stainless steel cleaner and polish in accordance with the manufacturer s instructions. Many of these products leave a protective coating that helps prevent future smears and fingerprints. Grease and Oil : To remove grease and oil use a quality commercial detergent or caustic cleaner. Apply in accordance to the manufacturer s instructions and in the direction of the polish lines. Precautions: Avoid prolonged contact with chlorides (bleaches, salts), bromides (sanitizing agents), thiocyanates (pesticides, photography chemicals, and some foods), and iodides on stainless steel equipment, especially if acid conditions exist. CAUTION! Do not permit salty solutions to evaporate and dry on stainless steel. The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the actual source of the rust in some iron or steel particles which may be touching, but not actually a part of the stainless steel structure. NOTE: Strongly acidic or caustic cleaners may attack the steel, causing a reddish film to appear. The use of these cleaners should be avoided. Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions. Bradley 215-1785 Rev. B; ECN 14-03-005E 10/6/2014 5