Warranty on production defects: 12 years WP YEARS WARRANTY. CLASS 1 CLASS 1 Reaction to fire according to the UNI 9177 UNI standard IEC 61215

Similar documents
250 Watt. Features. Positive tolerance Positive tolerance of up to 5% delivers higher outputs reliablity

PEIMAR S OFFICIAL BROCHURE - UK VERSION

X-SERIES SOLAR PANELS


E-SERIES RESIDENTIAL SOLAR PANELS

TSM-DC01A. The Solution NEW. linear performance warranty. Module can bear snow loads up to 5400Pa and wind loads up to 2400Pa

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T

PEIMAR S OFFICIAL BROCHURE - USA

18.6% 0-5w. Years. Grid. Certification. BYD PV Module 25 Years Linear Performance Warranty

Conergy PH 185M 200M. Special Edition Australia. Specifications Photovoltaic modules

F-Series 30W PV Module SPM030P-WP-F

SOLON SOLbond Integra. The Innovative Solar Rooftop System.

Product Catalogue. Europe

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

NEW-TEK SCHMID R Company High-tech enterprise for the production of PV solar modules

PHOTOVOLTAIC SOLAR PANELS

60CELLS 4BB MONO-CRYSTAL MODULES

INDEX. 3 BOREHOLE DC SOLAR PUMPS 3LLS...4 PERIPHERAL VANE DC SOLAR PUMP 3LSQB2...6

RNG Mono. Monocrystalline Type 10/20/30/50/60/100/150/250W. Key Features High module conversion efficiency. Application. Linear Warranty.

Water temperature: Dirt loss: Total dynamic head:

Staff Review Date: March 11, 2015 HDC

40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3

F-Series 10W PV Module SPM010P-F

INSTALLATION AND SAFETY MANUAL for Cigs-2000A1 and Cigs-2000E1 Solar Photovoltaic Modules Release Date: Version: 1.1

SOLAR PHOTOVOLTAIC V-SYS ULTRA - FLEXI - ON FLOOR - ON TOP. MADE IN FRANCE

Photovoltaic Modules Installation Manual for Australia

SOLAR ENERGY SYSTEMS. PV Energy Systems & Solar Thermal Systems

FUTURE LIVING TODAY INNENCO QUANTUM SOLAR IQS

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

sun Find us at : Website : SGS QMS MNRE APPROVED ISO 9001 SAAR ISPL System Cert

Sample Solar PV Electrical One Line

KIT SOLAR MONTE PERDIDO

High-Power, American Quality

Tianwei New Energy Holding Co., Ltd.

English be1202. Europen Photovoltaic Industry Association

Product Catalogue EUROPE

IEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE

SAMPLE PERMIT APPLICATION PACKAGE

SOLAR ENERGY KIT MODEL: SISMA-CT20000

Datasheets. Residential On-Grid Photovoltaic System Kits

Solar Electric Modules

SOLAR ENERGY KIT MODEL: SISMA-CS3500

Solar Photovoltaic Panels

Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.

PV Module Installation Manual

FULLY CERTIFIED ON-TIME DELIVERY ATEC GRP ENCLOSURES

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

JA SOLAR INSTALLATION MANUAL

INSTALLATION MANUAL. IEC version. TSM_IEC_IM_2012_RevB

Index. Introduction p. 4 Cells p. 7. Double glass p. 8. Monocrystalline p. 10 Black series p. 13 Polycrystalline p. 14

Shinsung Solar Energy

Installation Manual. Opal Solar QSA Series

CEYLON SOLAR POWER (PVT) LTD.

Installation Manual for LONGi Solar Modules

10KW 3 Phase Off Grid Hybrid System

Details and specification for 30 W solar powered LED street lights.

Where. Where there s sun. there s SUNGEN.

INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL

Installation and Safety Manual

Safety and Installation Instructions

P H O T O V O LTA I C

General Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

JinkoSolar. Photovoltaic Module. User Manual (UL1703)

Rooftops requiring a building integrated solar solution with no roof penetrations

AC MODULE P72PCS-300W

PM220P00 / PM240P00 Installation Guide for Users

Daily output in May 32 m³

Installation Manual AXITEC SOLAR MODULES

SPECIAL SPECIFICATION 6576 Solar Panel Power Supply System

Contents. VBHNxxxSJ40 series. VBHNxxxSJ47 series. General Installation Manual. Photovoltaic Module HIT TM. VBHNxxxSJ40 series. VBHNxxxSJ25 series

Colour your life! BISOL Spectrum Series. www. bisol. com

The colorful world of GridParity and Almaden products

DC Cabling Ready for 1,500 V DC

Solar Photovoltaic Panels

Wind-Solar Hybrid Power Generation Systems. Energy Pvt. Ltd.

Suntech Power Cutting-Edge Technology

BYD 430 Double Glass Module

Photovoltaic Module User Manual

Crystalline Silicon PV Module Installation Guide (JET)

Trinasmart SEUK Oct Daniel E. Mamat Product Management

General Installation Manual Photovoltaic Module HIT. Contents. Model No. VBHN330SA16 and 16B VBHN325SA16 and 16B

INSTALLATION MANUAL MODULE TSM-PDG5/PDG5(C) TSM-PEG5/PEG5(C) TSM-PEG40 THE. UL version IEC version. TSM_UL/IEC_IM_Dec_2014_RevB - 1 -

DELTA SOLAR LED LIGHTING

SOLAR STREET LIGHT SSLX30W SSLX40W SSLX60W

Contents. VBHNxxxSJ40 series VBHNxxxSJ47 series. General Installation Manual. Photovoltaic Module HIT R. VBHNxxxSJ25 series VBHNxxxSJ40 series

Installation and Maintenance Manual

Daily output in average month 77 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

For Further information please visit our PSIDA DIY PVac660 fully integrated AC system

PM300P00 Installation Guide for Users

SunSwitch setting in PumpScanner. Daily output in average month 219 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under Ownership Model

Philadelphia Solar Installation and Operation Manual

JinkoSolar. Photovoltaic Module. User Manual (UL1703) 1500V

Section 7: Price Schedule Form 1

ESCI 61- PV Cells Modules and Arrays April 21- Week 3 Agenda

Distribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world

About the table RENEW 2018 SOLAR PANEL BUYERS GUIDE

Crystalline Silicon PV Module Installation Manual

Transcription:

AZIMUT MONOCRYSTALLINE Italian Product Product Made in Italy YEARS WARRANTY Warranty on production defects: years WP Classification Only positive MPP +3 / -0% + kwh produced each year Periodic Factory inspection by TÜV Intercert CLASS CLASS Reaction to fire according to the UNI 977 UNI 977 standard IEC 670 NH 3 Ammonia test according to Salt mist test according to IEC 670 Member of the end-of-life panel recycling zero hassle to customers IEC 65 Panel certifications IEC 65 TRACEABILITY product traceability 00 Azimut Industrial Standard Nominal Power [%] 95 90 85 80 Warranty on rated output 30-year warranty period on output: 97% after year, 90% after 5 years, 80% after 30 years Typical spectral response 75 Performance at low irradiance 2 4 3 5 6 7 8 9 0 3 4 5 6 7 8 9 20 2 22 23 25 24 26 27 28 29 30 Years 6,05 Rel. Sr. 4 0 8 6 4 2 Relative efficiency 0,95 0,9 0,85 0 0,8 300 400 500 600 700 800 900 000 00 00 200 300 400 500 600 700 800 900 000 Nm Irradiation [W/m²] The graph shows the change in terms of module efficiency with a variation in irradiation spanning from 200 W/m² to 000 W/m² (with 25 C and AM.5 spectrum) is equal to -2% (relative).

AZM486M (.5 AM, IRR 000 w/m2; temperature 25±2 C) 205 330 323 (LAMINATED) (.5 AM, IRR 000 w/m2; temperature 25±2 C) 983 (LAMINATED) ID LABEL Nominal power Pnom W 205 Classification in Power % 0 / + 3 Voltage at Pmax Vmp V 24,9 Current at Pmax Imp A 8,23 Open-circuit voltage Voc V 29,55 Short-circuit voltage Isc A 8,95 Module efficiency % 5,57 (IRR 800 w/m2; RT 20 c; t. 44 C; wind speed m/s,.5 AM) Nominal power Pnom W 50 Voltage at Pmax Vmp V 22,8 Current at Pmax Imp A 6,58 Open-circuit voltage Voc V 27,04 Short-circuit voltage Isc A 7, Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% 225 Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm 48 (6x8) monocrystalline, 56 x 56 mm Junction box IP65, 3 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm 2 IP68, PV4 single-contact connectors 330 x mm +/- mm (L323 x 983 mm) 6 +/- kg Black back sheet (N), transparent back sheet (T), laminated (L), black laminated (LN), transparent laminated (LT). AZM546M Nominal power Pnom W 225 Classification in Power % - 0 / + 3 Voltage at Pmax Vmp V 27,57 Current at Pmax Imp A 8,6 Open-circuit voltage Voc V 32,80 Short-circuit voltage Isc A 8,85 Module efficiency % 5,25 (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 65 Voltage at Pmax Vmp V 25,25 Current at Pmax Imp A 6,52 Open-circuit voltage Voc V 30,02 Short-circuit voltage Isc A 7,03 Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% 490 483 (LAMINATED) 983 (LAMINATED) ID LABEL Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm 54 (6x9) monocrystalline, 56 x 56 mm Junction box IP65, 3 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm 2 IP68, single-contact connectors 490 x mm +/- mm (L483 x 983mm) 8 +/- kg Black back sheet (N), transparent back sheet (T), laminated (L), black laminated (LN), transparent laminated (LT).

(.5 AM, IRR 000 w/m2; temperature 25±2 C) 255 260 265 AZM606M Nominal power Pnom W 255 260 265 982 (LAMINATED) 5 Classification in Power % 0 / + 3 Voltage at Pmax Vmp V 3,0 3,33 3,56 Current at Pmax Imp A 8,20 8,30 8,40 Open-circuit voltage Voc V 36,97 37,27 37,56 Short-circuit voltage Isc A 8,90 9,00 9,0 Module efficiency % 5,6 5,92 6,22 (IRR 800 w/m2; RT 20 c; t. 44 C; wind speed m/s,.5 AM) Nominal power Pnom W 87 90 94 Voltage at Pmax Vmp V 28,48 28,69 28,90 Current at Pmax Imp A 6,55 6,63 6,7 650 642 (LAMINATED) Open-circuit voltage Voc V 33,83 34,0 34,37 Short-circuit voltage Isc A 7,07 7,5 7,23 Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: Pmp 5%; Voc, Vmp, Isc, Imp 0% Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm 60 (6x0) monocrystalline, 56 x 56 mm Junction box IP65, 3 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm 2 IP68, PV4 single-contact connectors. 650 x mm +/- mm (L642 x 982 mm) 9,5 +/- kg AZM666M Black back sheet (N), transparent back sheet (T), laminated (L), black laminated (LN), transparent laminated (LT). (.5 AM, IRR 000 w/m2; temperature 25±2 C) 280 Nominal power Pnom W 280 Classification in Power % 0 / + 3 Voltage at Pmax Vmp V 34,23 Current at Pmax Imp A 8,8 Open-circuit voltage Voc V 40,59 Short-circuit voltage Isc A 8,90 Module efficiency % 5,69 806 (IRR 800 w/m2; RT 20 c; t. 44 C; wind speed m/s,.5 AM) Nominal power Pnom W 205 Voltage at Pmax Vmp V 3,34 Current at Pmax Imp A 6,54 Open-circuit voltage Voc V 37,4 Short-circuit voltage Isc A 7,07 ID LABEL Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% Prismatic tempered glass with high U value. Thickness 4 mm. 66 (6x) monocrystalline, 56 x 56 mm Junction box IP65, 3 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm 2 IP68, PV4 single-contact connectors 806 x mm +/- mm 23,5 +/- kg Black back sheet (N), transparent back sheet (T)

(.5 AM, IRR 000w/m2; temperature 25±2 C) 305 AZM726M Nominal power Pnom W 305 Classification in Power % - 0 / + 3 Voltage at Pmax Vmp V 37,24 Current at Pmax Imp A 8,9 Open-circuit voltage Voc V 44,22 Short-circuit voltage Isc A 8,90 Module efficiency % 5,74 (IRR 800 W/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 223 Voltage at Pmax Vmp V 34,0 Current at Pmax Imp A 6,54 Open-circuit voltage Voc V 40,46 Short-circuit voltage Isc A 7,07 Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% 96 Prismatic tempered glass with high U value. Thickness 4 mm. 72 (6x) monocrystalline, 56 x 56 mm ID LABEL Junction box IP65, 4 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm2 IP68, PV4 single-contact connectors 96 x mm +/- mm 25 +/- kg Black back sheet (N), transparent back sheet (T) Please note: in case of landscape installation a 25-cm-long extension cable with MC4 connectors is necessary. Operation Characteristics/Build Maximum system voltage V 000 Maximum series fuse rating IR A 3 Temperature coefficient MPP (ɣ) %/ C -0,48 Temperature coefficient Voc (β) %/ C -0, Temperature coefficient Isc (α) %/ C 0,07 NOCT C 44 +/- Service temperature C from -40 C to +85 C Safety class II Snow load / Max. wind speed Pa 5400 Resistance to hail impact Ø 25 mm at 83 km/h Encapsulating agent Protective backing Frame 2 sheets of 0.46 mm EVA Multilayer polyester lamination Al 6060 T5, thickness mm Data sheet compliant with EN 500.

DYNAMIC HIGHER EFFICIENCY COMBINED WITH AZIMUT QUALITY Dynamic version of Azimut modules is characterized by pyramid-shaped structures of the glass that enhance efficiency and therefore performances. AZIMUT DYNAMIC ADVANTAGES: Higher stability and resistance of the modules The special glass of Azimut Dynamic modules is characterized by a 4 mm thickness, which guarantees additional stability and toughness. Higher performance of the photovoltaic system With Azimut Dynamic modules efficiency can increase up to 20% in the morning and afternoon and of 4-5% in the yearly production. Moreover, thanks to the low percentage of iron oxide, the energy absorption in the glass is almost zero. Self-cleaning and perfect interaction with Azimut CleanTech technology The particular shape of the glass allows the flow of rainwater and consequently triggers a phenomenon of selfcleaning of the module. In order to get even better performances Azimut Dynamic modules can also be combined with our CleanTech technology, with which they perfectly interact. (*) Reduction of reflection Light-trapping effect All of Azimut modules can be manufactured in Dynamic version. For models and technical details please see specific datasheets. (*) Please see Azimut CleanTech datasheet. CARATTIEPOLETTO ADV

AZIMUT POLYCRYSTALLINE hp HIGH POWER Italian Product Product Made in Italy YEARS WARRANTY Warranty on production defects: years WP Classification Only positive MPP +3 / -0% + kwh produced each year Periodic Factory inspection by TÜV Intercert CLASS CLASS Reaction to fire according to the UNI 977 UNI 977 standard IEC 670 NH 3 Ammonia test according to Salt mist test according to IEC 670 Member of the end-of-life panel recycling zero hassle to customers IEC 65 Panel certifications IEC 65 TRACEABILITY product traceability Azimut Industrial Standard 00 Nominal Power [%] 95 90 85 80 75 Warranty on rated output 30-year warranty period on output: 97% after year, 90% after 5 years, 80% after 30 years Typical spectral response Performance at low irradiance 2 4 3 5 6 7 8 9 0 3 4 5 6 7 8 9 20 2 22 23 25 24 26 27 28 29 30 Years Rel. Sr. 6 4 0 8 6 4 2 Relative efficiency,05 0,95 0,9 0,85 0 0,8 300 400 500 600 700 800 900 000 00 00 200 300 400 500 600 700 800 900 000 Nm Irradiation [W/m²] The graph shows the change in terms of module efficiency with a variation in irradiation spanning from 200 W/m² to 000 W/m² (with 25 C and AM.5 spectrum) is equal to -2% (relative).

ELECTRICAL CHARACTERISTICS UNDER STC (AM,5, IRR 000W/m2; temperature 25±2 C) 982 (LAMINATO) 5 AZM606/275P AZM666/300P Nominal power Pnom W 275 300 Classification in Power % - 0 / + 3 Voltage at Pmax Vmp V 32,39 35, Current at Pmax Imp A 8,49 8,54 Open-circuit voltage Voc V 39,48 43,07 Short-circuit voltage Isc A 9,0 9,0 Module efficiency % 6,84% 6,8% 650 642 (LAMINATO) AZM 606 ELECTRICAL CHARACTERISTICS UNDER NOCT CONDITIONS (IRR 800 w/m 2 ; RT 20 c; t. 43 C; wind speed m/s, AM,5) Nominal power Pnomt W 20 29 Voltage at Pmax Vmp V 29,66 32,6 Current at Pmax Imp A 6,78 6,82 Open-circuit voltage Voc V 36, 39,4 Short-circuit voltage Isc A 7,28 7,28 Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% Junction box Tempered, prismatic, high transmittance glass. 3.2 mm thickness for the 60 cells version and 4 mm for the 66 cells version. 60 (6x0) polycrystalline, 56 x 56 mm 66 (6x) polycrystalline, 56 x 56 mm IP65, 3 bypass diodes, 4 mm 2 cables w/length 00(+) / 00(-) cm IP67, PV4 single-contact connectors 650 x mm +/- mm (60 cells) 806 x mm +/- mm (66 cells) 806 ID LABEL AZM 666 9,5 kg (60 cells) 23,5 kg (66 cells) s laminate (L) available only for the 60 cells version, black (N). Operation Characteristics/Build Maximum system voltage V 000 Maximum series fuse rating IR A 3 Temperature coefficient Pmp (ɣ) %/ C -0,42 Temperature coefficient Voc (β) %/ C -0,32 Temperature coefficient Isc (α) %/ C 0,08 NOCT C 43 +/- Service temperature C from -40 C to +85 C Safety class II Snow load / Max. wind speed Pa 5400 Resistance to hail impact Ø 25 mm at 83 km/h Encapsulating agent Protective backing Frame 2 sheets of 0.46 mm EVA Multilayer/trasparent polyester lamination, 0.32 mm thick Al 6060 T5, thickness mm Data sheet compliant with EN 500

AZIMUT POLYCRYSTALLINE Italian Product Product Made in Italy YEARS WARRANTY Warranty on production defects: years WP Classification Only positive MPP +3 / -0% + kwh produced each year Periodic Factory inspection by TÜV Intercert CLASS CLASS Reaction to fire according to the UNI 977 UNI 977 standard IEC 670 NH 3 Ammonia test according to Salt mist test according to IEC 670 Member of the end-of-life panel recycling zero hassle to customers IEC 65 Panel certifications IEC 65 TRACEABILITY product traceability 00 Azimut Industrial Standard Nominal Power [%] 95 90 85 80 Warranty on rated output 30-year warranty period on output: 97% after year, 90% after 5 years, 80% after 30 years Typical spectral response 75 Performance at low irradiance 2 4 3 5 6 7 8 9 0 3 4 5 6 7 8 9 20 2 22 23 25 24 26 27 28 29 30 Years 6,05 Rel. Sr. 4 0 8 6 4 2 Relative efficiency 0,95 0,9 0,85 0 0,8 300 400 500 600 700 800 900 000 00 00 200 300 400 500 600 700 800 900 000 Nm Irradiation [W/m²] The graph shows the change in terms of module efficiency with a variation in irradiation spanning from 200 W/m² to 000 W/m² (with 25 C and AM.5 spectrum) is equal to -2% (relative).

AZM486P (.5 AM, IRR 000w/m2; temperature 25±2 C) 200 (.5 AM, IRR 000w/m2; temperature 25±2 C) 240 245 250 255 260 AZM606P 983 (LAMINATED) Nominal power Pnom W 200 Classification in Power % - 0 / + 3 Nominal power Pnom W 240 245 250 255 260 Classification in Power % - 0 / + 3 982 (LAMINATED) 5 Voltage at Pmax Vmp V 24,82 Voltage at Pmax Vmp V 30,4 30,72 3,02 3,3 3,60 Current at Pmax Imp A 8,06 Current at Pmax Imp A 7,89 7,97 8,06 8,4 8,23 Open-circuit voltage Voc V 30,4 Open-circuit voltage Voc V 37, 37,70,0,32,62 Short-circuit voltage Isc A 8,6 Short-circuit voltage Isc A 8,40 8,50 8,60 8,70 8,80 330 323 (LAMINATED) Module efficiency % 5,9 (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 46 Voltage at Pmax Vmp V 22,73 Current at Pmax Imp A 6,44 Module efficiency % 4,69 5,00 5,30 5,6 5,92 (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 76 79 83 87 90 Voltage at Pmax Vmp V 27,85 28,3 28,4 28,67 28,93 Current at Pmax Imp A 6,3 6,37 6,44 6,5 6,57 650 642 (LAMINATED) Open-circuit voltage Voc V 27,83 Open-circuit voltage Voc V 34,20 34,49 34,78 35,06 35,34 Short-circuit voltage Isc A 6,87 Short-circuit voltage Isc A 6,7 6,79 6,87 6,95 7,04 ID LABEL Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm. 48 (6x8) polycrystalline, 56 x 56 mm Junction box IP65.3 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm 2 60 (6x0) polycrystalline, 56 x 56 mm Junction box IP65.3 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm 2 IP68, PV4 single-contact connectors IP68, PV4 single-contact connectors 330 x mm +/- mm (L323 x 983 mm) 650 x mm +/- mm (L642 x 982 mm) 6 +/- kg 9,5 +/- kg Black backsheet (N), (T), laminated (L), black laminated (LN), transparent laminated (LT). Black backsheet (N), (T), laminated (L), black laminated (LN), transparent laminated (LT). (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) 225 AZM546P AZM666P Dati elettrici in condizioni STC (AM,5, IRR 000w/m 2 ; temperatura 25±2 C) 265 270 275 280 Nominal power Pnom W 225 Classificazione in Potenza % - 0 / + 3 Voltage at Pmax Vmp V 28 Current at Pmax Imp A 8,04 Open-circuit voltage Voc V 34,2 Short-circuit voltage Isc A 8,6 Module efficiency % 5,25 (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 65 Voltage at Pmax Vmp V 25,64 Current at Pmax Imp A 6,42 Open-circuit voltage Voc V 3,30 Short-circuit voltage Isc A 6,87 Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: Pmp 5%; Voc, Vmp, Isc, Imp 0% 490 483 (LAMINATED) 983 (LAMINATED) ID LABEL 806 Nominal power Pnom W 265 270 275 280 Classification in Power % - 0 / + 3 Voltage at Pmax Vmp V 33, 33,65 33,92 34,8 Current at Pmax Imp A 7,94 8,02 8, 8,9 Open-circuit voltage Voc V 4,27 4,55 4,8 42,08 Short-circuit voltage Isc A 8,40 8,50 8,60 8,70 Module efficiency % 4,85 5,3 5,4 5,69% (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 94 98 20 205 Voltage at Pmax Vmp V 30,56 30,8 3,06 3,30 Current at Pmax Imp A 6,34 6,4 6,48 6,55 Open-circuit voltage Voc V 37,76,0,26,50 Short-circuit voltage Isc A 6,7 6,79 6,87 6,95 Precision of measurement under STC: Pmp 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: Pmp 5%; Voc, Vmp, Isc, Imp 0% Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm. 54 (6x9) polycrystalline, 56 x 56 mm Junction box IP65.3 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm 2 IP68, PV4 single-contact connectors ID LABEL Prismatic tempered glass with high U value. Thickness 4 mm. 66 (6x) policristalline, 56 x 56 mm Junction box IP65.3 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm 2 IP68, PV4 single-contact connectors 490x mm +/- mm (L483 x 983 mm) 806 x mm +/- mm 8 kg 23,5 +/- kg Black backsheet (N), (T), laminated (L), black laminated (LN), transparent laminated (LT). Black backsheet (N), transparent backsheet (T).

DATI ELETTRICI IN CONDIZIONI STC (AM,5, IRR 000W/m2; Temperatura 25±2 C) 290 295 300 30 AZM726P Nominal power Pnom W 290 295 300 30 Classification in Power % - 0 / + 3 Voltage at Pmax Vmp V 36,56 36,8 37,04 37,5 Current at Pmax Imp A 7,93 8,0 8,0 8,27 Open-circuit voltage Voc V 45,6 45,39 45,62 46,05 Short-circuit voltage Isc A 8,40 8,50 8,60 8,80 Module efficiency % 4,97 5,23 5,48 5,97 (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 2 26 29 227 Voltage at Pmax Vmp V 33,48 33,70 33,92 34,35 Current at Pmax Imp A 6,34 6,40 6,47 6,60 Open-circuit voltage Voc V 4,32 4,53 4,74 42,3 Short-circuit voltage Isc A 6,7 6,79 6,87 7,05 Precision of measurement under STC: Pmp 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: Pmp 5%; Voc, Vmp, Isc, Imp 0% 96 Prismatic tempered glass with high U value. Thickness 4 mm. Junction box 72 (6x) polycrystalline, 56 x 56 mm IP65, 4 bypass diodes, 4 mm cables w/length 00 (+) / 00 (-) cm2 ID LABEL IP68, PV4 single-contact connectors 96 x mm +/- mm 25 +/- kg Black backsheet (N), transparent backsheet (T). Please note: in case of landscape installation a 25-cm-long extension cable with MC4 connectors is necessary. Operation Characteristics/Build Maximum system voltage V 000 Maximum series fuse rating IR A 3 Temperature coefficient Pmp (ɣ) %/ C -0,42 Temperature coefficient Voc (β) %/ C -0,32 Temperature coefficient Isc (α) %/ C 0,08 NOCT C 43 +/- Service temperature C from -40 C to +85 C Safety class II Snow load / Max. wind speed Pa 5400 Resistance to hail impact Ø 25 mm at 83 km/h Encapsulating agent Protective backing Frame 2 sheets of 0.46 mm EVA Multilayer polyester lamination, 0.32 mm thick Al 6060 T5, thickness mm Data sheet compliant with EN 500

RED Product Made in Italy YEARS WARRANTY Warranty on production defects: years WP Classification Only positive MPP +3 / -0% + kwh produced each year Factory inspection periodica del TÜV Intercert CLASSE CLASS Reaction to fire according to the UNI 977 UNI 977 standard IEC 670 NH 3 Ammonia test according to Member of the end-of-life panel recycling zero hassle to customers IEC 65 Panel certifications IEC 65 TRACEABILITY product traceability Azimut Industrial Standard 00 Nominal Power [%] 95 90 85 80 75 Warranty on rated output 30-year warranty period on output: 97% after year, 90% after 5 years, 80% after 30 years Typical spectral response Performance at low irradiance 2 4 3 5 6 7 8 9 0 3 4 5 6 7 8 9 20 2 22 23 25 24 26 27 28 29 30 Years Rel. Sr. 6 4 0 8 6 4 2 Relative efficiency,05 0,95 0,9 0,85 0 0,8 300 400 500 600 700 800 900 000 00 00 200 300 400 500 600 700 800 900 000 Nm Irradiation [W/m²] The graph shows the change in terms of module efficiency with a variation in irradiation spanning from 200 W/m² to 000 W/m² (with 25 C and AM.5 spectrum) is equal to -2% (relative).

ELECTRICAL CHARACTERISTICS UNDER STC (AM,5, IRR 000W/m2; temperature 25±2 C) 982 (LAMINATO) RED 240 RED 250 Nominal power Pnom W 240 250 Classification in Power % - 0 / + 3 Voltage at Pmax Vmp V 30,4 32,05 5 Current at Pmax Imp A 7,89 7,80 Open-circuit voltage Voc V 37, 39,9 Short-circuit voltage Isc A 8,40 8,20 Module efficiency % 4,69% 4,0% 650 642 (LAMINATO) RED 240 ELECTRICAL CHARACTERISTICS UNDER NOCT CONDITIONS (IRR 800 w/m 2 ; RT 20 c; t. 43 C; wind speed m/s, AM,5) Nominal power Pnomt W 76 83 Voltage at Pmax Vmp V 27,85 29,35 Current at Pmax Imp A 6,3 6,23 Open-circuit voltage Voc V 34,20 36,5 Short-circuit voltage Isc A 6,7 6,55 Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% Junction box Tempered, prismatic, high transmittance glass. 3.2 mm thickness for the 60 cells version and 4 mm for the 66 cells version. 60 (6x0) polycrystalline, 56 x 56 mm 66 (6x) polycrystalline, 56 x 56 mm IP65, 3 bypass diodes, 4 mm 2 cables w/length 00(+) / 0(-) cm PV4 single-contact connectors 806 RED 250 650 x mm +/- mm (60 cells) 806 x mm +/- mm (66 cells) ID LABEL 9,5 kg (60 cells) 23,5 kg (66 cells) s laminate (LR) available only for the 60 cells version. Operation Characteristics/Build Maximum system voltage V 000 Maximum series fuse rating IR A 3 Temperature coefficient Pmp (ɣ) %/ C -0,42 Temperature coefficient Voc (β) %/ C -0,32 Temperature coefficient Isc (α) %/ C 0,08 NOCT C 43 +/- Service temperature C from -40 C to +85 C Safety class II Snow load / Max. wind speed Pa 5400 Resistance to hail impact Ø 25 mm at 83 km/h Encapsulating agent Protective backing Frame 2 sheets of 0.46 mm EVA Multilayer/trasparent polyester lamination, 0.32 mm thick Al 6060 T5, thickness mm Data sheet compliant with EN 500

AZIMUT DAYLIGHT Italian Product Product Made in Italy YEARS WARRANTY Warranty on production defects: years WP Classification Only positive MPP +3 / -0% + kwh produced each year Factory inspection periodica del TÜV Intercert CLASSE CLASS Reaction to fire according to the UNI 977 UNI 977 standard IEC 670 NH 3 Ammonia test according to Salt mist test according to IEC 670 Member of the end-of-life panel recycling zero hassle to customers IEC 65 Panel certifications IEC 65 TRACEABILITY product traceability 00 Azimut Industrial Standard Nominal Power [%] 95 90 85 80 Warranty on rated output 30-year warranty period on output: 97% after year, 90% after 5 years, 80% after 30 years Typical spectral response 75 Performance at low irradiance 2 4 3 5 6 7 8 9 0 3 4 5 6 7 8 9 20 2 22 23 25 24 26 27 28 29 30 Years 6,05 Rel. Sr. 4 0 8 6 4 2 Relative efficiency 0,95 0,9 0,85 0 0,8 300 400 500 600 700 800 900 000 00 00 200 300 400 500 600 700 800 900 000 Nm Irradiation [W/m²] The graph shows the change in terms of module efficiency with a variation in irradiation spanning from 200 W/m² to 000 W/m² (with 25 C and AM.5 spectrum) is equal to -2% (relative).

AZM486 P/M T 982 (LAMINATED) 5 (.5 AM, IRR 000w/m2; temperature 25±2 C) Nominal power Pnom W 200 205 Classification in Power % - 0 / + 3-0 / + 3 Voltage at Pmax Vmp V 24,82 24,9 Current at Pmax Imp A 8,06 8,23 Open-circuit voltage Voc V 30,4 29,55 Short-circuit voltage Isc A 8,6 8,95 Module efficiency %,24,55 200 PT 205 MT 650 642 (LAMINATED) ID LABEL 25 (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 46 50 Voltage at Pmax Vmp V 22,73 22,8 Current at Pmax Imp A 6,44 6,58 Open-circuit voltage Voc V 27,83 27,04 Short-circuit voltage Isc A 6,87 7, Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% With a cell spacing of 25 mm and 28% of the surface area transparent, the panel was specially developed in a transparent version to be used on the roofs of greenhouses, pergolas, canopies, bus shelters and any place where much light is needed underneath the photovoltaic system. 09,5 Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm 48 (6x8) poly/monocrystalline, 56 x 56 mm Junction box IP65.3 bypass diodes, 4 mm cables w/length 00 (+) / 0 (-) cm 2 IP67, MC4 single-contact connectors 650 x mm +/- mm (L642 x 982 mm) 9,5 +/- kg Transparent backsheet (T), laminated and transparent backsheet (LT). (.5 AM, IRR 000w/m2; temperature 25±2 C) Nominal power Pnom W 225 225 Classificazione in Potenza % - 0 / + 3-0 / + 3 Voltage at Pmax Vmp V 28 27,57 Current at Pmax Imp A 8,04 8,6 Open-circuit voltage Voc V 34,2 32,80 Short-circuit voltage Isc A 8,6 8,85 Module efficiency % 3,77 3,77 (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 65 65 Voltage at Pmax Vmp V 25,64 25,25 Current at Pmax Imp A 6,42 6,52 Open-circuit voltage Voc V 3,30 30,02 Short-circuit voltage Isc A 6,87 7,03 Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% Junction box Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm. 54 (6x8) poly/monocrystalline, 56 x 56 mm IP65.3 bypass diodes, 4 mm cables w/length 00 (+) / 0 (-) cm2 IP67, MC4 single-contact connectors 650 x mm +/- mm (L642 x 982 mm) 9,5 +/- kg Transparent backsheet (T), laminated and transparent backsheet (LT) 225 PT 225 MT AZM546 P/M T 650 642 (LAMINATED) 982 (LAMINATED) With a cell spacing of 20 mm and 9% of the surface area transparent, the panel was specially developed in a transparent version to be used on the roofs of greenhouses, pergolas, canopies, bus shelters and any place where a lot of light is needed underneath the photovoltaic system. ID LABEL 20 39 5

(.5 AM, IRR 000w/m2; temperature 25±2 C) Nominal power Pnom W 250 255 Classification in Power % - 0 / + 3 0 / + 3 Voltage at Pmax Vmp V 3,02 3,0 Current at Pmax Imp A 8,06 8,20 Open-circuit voltage Voc V,0 36,97 Short-circuit voltage Isc A 8,60 8,90 Module efficiency % 5,30 5,6 250 PT 255 MT AZM606 P/M T 982 (LAMINATED) 5 (IRR 800 w/m2; RT 20 c; t. 43 C; wind speed m/s,.5 AM) Nominal power Pnom W 83 87 Voltage at Pmax Vmp V 28,4 28,48 Current at Pmax Imp A 6,44 6,55 Open-circuit voltage Voc V 34,78 33,83 Short-circuit voltage Isc A 6,87 7,07 Precision of measurement under STC: MPP 3%; Voc, Vmp, Isc, Imp 0% Precision of measurement under NOCT conditions: MPP 5%; Voc, Vmp, Isc, Imp 0% 650 642 (LAMINATED) Prismatic tempered glass with high U value. Thickness of framed panels 3.2 mm and thickness for laminated panels 4 mm. 60 (6x0) poly/monocrystalline, 56 x 56 mm Junction box IP65.3 bypass diodes, 4 mm cables w/length 00 (+) / 0 (-) cm 2 IP67, MC4 single-contact connectors 650 x mm +/- mm (L642 x 982 mm) 9,5 +/- kg Transparent backsheet (T), laminated and transparent backsheet (LT) With a cell spacing of 3 mm and 0% of the surface area transparent, the panel was specially developed in a transparent version to be used on the roofs of greenhouses, pergolas, canopies, bus shelters and any place where a lot of light is needed underneath the photovoltaic system. Operation Characteristics/Build PT MT Maximum system voltage V 000 000 Maximum series fuse rating IR A 3 3 Temperature coefficient Pmp (ɣ) %/ C -0,42-0,48 Temperature coefficient Voc (β) %/ C -0,32-0, Temperature coefficient Isc (α) %/ C 0,08 0,07 NOCT C 43 +/- 44 +/- Service temperature C from -40 C to +85 C from -40 C to +85 C Safety class II II Snow load / Max. wind speed Pa 5400 5400 Resistance to hail impact Ø 25 mm at 83 km/h Ø 25 mm at 83 km/h Encapsulating agent Protective backing Frame 2 sheets of 0.46 mm EVA Multilayer/trasparent polyester lamination, 0.32 mm thick Al 6060 T5, thickness mm Data sheet compliant with EN 500

Azimut PHOTOVOLTAIC TECHNOLOGIES Produzione Moduli Fotovoltaici Visit our website www.azimut-pv.com

SMART ROOF FULL INTEGRATION WITH AZIMUT MODULES Suitable for residential and corporate buildings, SMART ROOF system can be installed on every kind of roof with metal corrugated sheet. This solution is perfect for residential, industrial and farming installations. SMART ROOF ADVANTAGES: Adaptability and flexibility The system can be integrated into the roof of new or existing buildings, both residential and industrial, regardless of the type of roofing. It is sufficient to lay a metal corrugated sheet or to use the existing one, to install a highly customised and performing system. Easy, fast and safe All the components of the system are designed and manufactured in order to fit the special dedicated frame of Azimut modules. The modular layout and precision of brackets make the installation very easy and shorten its time. The lack of long aluminum rails reduces the risks of falling down due to their handling on the roof. Highly competitive system Our patented system exploits module frames as a structural element, remarkably reducing the mounting components and therefore their costs. Moreover, this allows to keep shipment charges very low. High quality and efficiency AZIMUT modules are produced according to strict technical specifications to ensure quality and durability. The selected materials (cells, glass, connection systems...) meet the requirements of safety and performance of the final product. For more details about AZIMUT modules see technical data sheet. Aesthetics and finishing Reducing the height and spaces between modules compared to a traditional system, Smart Roof perfectly matches with the roof surface and ensures the aesthetic quality of the design of the structure.

TECHNICAL DESCRIPTION: Positioning Covering of the roof on a pitched roof, with metal corrugated sheet any (more information on request) Slope from 3 up to 45 Configuration Orientation Height of the system Assembling Brackets Warranty photovoltaic surface on the whole roof or on a part of it vertical/horizontal for AZM606, horizontal for AZM666 and AZM726 56 mm (components included) quick fixing on special brackets extruded aluminum years All information contained in this form are our property and may be changed without notice. It is absolutely forbidden to reproduce them even partially. All rights will be protected by Azimut in terms of law.