ITEM PART NO. DESCRIPTION

Similar documents
3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

Specifications Information and Repair Parts Manual , , , &

IPT SERIES 2P5X, 2S5X AND 3S5X PUMPS Refer to pump manual for General Operating and Safety Instructions.

316 Series Engine Driven DESCRIPTION MAINTENANCE SHIM ADJUSTMENT. Specifications Information and Repair Parts Manual

3P9X & 3S9X DESCRIPTION SPECIFICATIONS UNPACKING PREPARING UNIT FOR OPERATION. Specifications Information and Repair Parts Manual

OPERATION, MAINTENANCE AND OVERHAUL INSTRUCTIONS FOR PB18 SERIES PORTABLE PUMPS

COOLING SYSTEM. Return to Main Table of Contents

Operating and Maintenance Manual Gas & Diesel Engine Powered Self-Priming Trash Pumps Series

1SP05C, 1SP07C, 12SP10C, 15SP15C, 2SP20C, & 2SP30C Series

Step 6: Remove and save the MAP sensor for later use. Step 7: Remove the passenger side intercooler pipe and the EGR intake manifold.

COOLING SYSTEM Return To Main Table of Contents

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

2MP Series Pumps Refer to pump manual for General Operating and Safety Instructions.

High Head Centrifugal Pedestal Pumps

25FP Fire Pump Series Refer to pump manual for General Operating and Safety Instructions.

3 October 2016 PN# V Dodge Twin Turbo Kit (I-00274) ½ D o d g e 2 4 v I S B

07ES05C, 1ES07C, 1ES10C, 12ES15C, 15ES20C, 2ES30C Series

DATA SHEET 6K151CT2, 6K151CT4, 6K201CT2, 6K201CT4, 6K301CT4, 6K401CT4 OPEN IMPELLER CENTRIFUGAL PUMPS. Stainless Steel Models: SPECIFICATIONS FEATURES

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

Maintenance. Daily. Shutdown Procedure. Periodically. During Freezing Temperatures

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

INSTALLATION INSTRUCTIONS

DESCRIPTION MAINTENANCE

F-20/G-20 Maintenance

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

MetroPrime 22MPC Self-Priming Centrifugal Pump

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

25FP Series ASSEMBLY SPECIFICATIONS BASIC CONSTRUCTION UNPACKING. Specifications Information and Repair Parts Manual

PowerMax Diesel Upgrade For Cummins Engines

D/G-03 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically

PERFORMANCE GPM of Water At Total Head in Feet

1-1/2 Inch Self-Priming Centrifugal Pumps Refer to pump manual for General Operating and Safety Instructions.

Self-Priming Centrifugal Pumps Refer to pump manual for General Operating and Safety Instructions.

KC Transmission Overhaul

MAINTENANCE CLEANING. MECHANICAL SEAL REPLACEMENT Refer to figures 1 and 2. SHIM ADJUSTMENT

INSTALLATION INSTRUCTIONS CATCH CAN KIT

D/G-10 Maintenance. Daily. Shutdown Procedure During Freezing Temperatures. Periodically

SPECIFICATIONS TEST AND ADJUSTMENT SPECIFICATIONS SPECIFICATIONS ENGINE FD620D, K SERIES

MODEL NO GALLON H.P. SKID SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

SERIES FE MAGNETIC COUPLED PUMPS

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

INSTALL MANUAL D o d g e 1 2 v 6 B T A PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION.

AS Centrifugal Pump Exploded View

FLOMAX SELF PRIMING CENTRIFUGAL PUMP FEATURES. 3 MP PUMPS, INC. PHONE: (800) FAX: (586) FLOMAX 5 FLOMAX 8

D-15/G-15 Maintenance

METERING/DOSING PUMP CLOSE-COUPLED B4015D, B4050D, B4100D, B4190D, B2400D, AND B4400D MODELS

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

INSTALLATION INSTRUCTIONS COOLANT TANK KIT

SECTION 4 - FUEL/LUBRICATION/COOLING

Model 306B H&J Transfer Case Service Manual

NOTE: Visit our website at for video repair procedures, under the Tools section.

Installation Instructions

CP-1, CP-2, CP-2L & CPD-2 Series Overhaul

Disassembly and Assembly

PB18 SERIES PORTABLE PUMPS

Disassembly and Assembly

Discharge diameters 1.5", 2", 3", 4", 5", 6", 8", 10", 12" & 14" HP 1 to 500. Split Coupled Vertical In-Line Pumps BVL

Parts List Single Reduction Models, Cast Iron Units

GM LS Series Serpentine Drive System with & without Power Steering

Chevrolet/GMC LB7 Duramax Turbo Kit

End Suction Centrifugal

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4

Installation, Operation, Repair and Parts Manual

DESCRIPTION MAINTENANCE. Specifications Information and Repair Parts Manual thru 282D-95 & thru 282M-95

MAINTENANCE DESCRIPTION. Specifications Information and Repair Parts Manual &

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1 ½-Inch High Pressure Pumps Refer to pump manual for General Operating and Safety Instructions.

HPS SERIES. Steam Joints DEUBLIN COMPANY Norman Drive, West Waukegan, IL USA Phone: 847/ Fax: 847/ Rev.

DESCRIPTION SPECIFICATIONS

XDP Complete EGR Race Track Kit w/up-pipe. Item Number: XD144

HP10207 KIT. Ram WD*

IMCO SCX SERIES INFORMATION, OPERATION & MAINTAINANCE

Installation, Operation, Repair and Parts Manual

This information covers the proper procedure for replacing the Volvo D16F engine in a VT or VNL chassis.

INTAKE/EXHAUST SYSTEM 7 C TURBOCHARGER

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series

INSTALLATION INSTRUCTIONS CATCH CAN KIT

2014 RAM C/V Tradesman

R35 GTR ALPHA X TURBO KIT INSTALLATION INSTRUCTIONS

Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE

EGR Actuator Slow Learn April Installation of the DD13 Exhaust Gas Recirculation Valve Actuator Pull Rod

REMOVAL & INSTALLATION

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Big Block Chevrolet Serpentine Drive System with & without Power Steering

Powerstroke 6.4L EGR Block Kit

Self Priming Trash Pump Model EFQT-12

GENERAL SPECIFICATIONS 25-2 GENERAL. Water cooling, forced circulation with electric fan

SPECIFICATIONS TEST AND ADJUSTMENT SPECIFICATIONS SPECIFICATIONS ENGINE FD620D, K SERIES

This information covers procedures for replacing the sealant for the crankshaft cover on the Volvo D16F engine.

ADM Performance 6079 Mapleshade Lane Dallas, Texas (214)

Electric Fuel Pump FPM

D/G-35 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically

200 & 300 Gallon 3 Point w/5880 Nozzle ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

WATER PUMP INSTALLATION INSTRUCTIONS WEIAND WATER PUMPS ACTION PLUS & TEAM G APPLICATIONS FOR SMALL BLOCK & BIG BLOCK CHEVROLETS

D-04/G-04 Maintenance

Close-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models

18SP680Rev3 EPA04 MBE 4000 Car Hauler Low Pressure Fuel Lines

Transcription:

ITEM PART NO. DESCRIPTION 1 18001 3" Pump Housing 2 18106 3 "- 16 x 1¼ FHSCS 3 18003 Drain Plug 4 18013 Check Valve Gasket 5 18008 Flange-Outlet 3" 6 18012 Flange-Inlet 3" 7 18002 1" NPT Plug 8 18004 Plate-Wear 9 18009 Gasket-Outlet 10 V20018 3 " Lockwasher 11 V20019 3 " Hex Nut 12 18021 Adapter Gasket 13 18129 Keyed Clamp 14 12910 Pump Decal 15 18200A Wet Seal Reservoir 16 17704 3 "- 16 x 1¼ HHCS 17 18033 Handle 18 18034 Handle Nut 19 18500 Bearing Pedestal 20 18010SS 3-16 x 1 " HHCS 6

3" Cast Iron Wet Seal 301 Series Pump Instruction Manual 301PIH13W, 301PBIW, 301POIW Read these instructions and the instructions covering the operation of the pump drive unit. Do not operate the gas engine (if so equipped) until you have put oil in the engine. Do not operate the wet seal pump until you have filled the wet seal reservoir ¾ full (the seal assembly should be submerged) with a 50% ethylene glycol (anti-freeze) and 50% water mixture. Check the coolant mixture level in the wet seal reservoir after every 5 hours of use, fill reservoir as necessary. Check oil level in the gas engine (if so equipped) after every 5 hours of use, fill reservoir as necessary. Change coolant mixture in reservoir after every 100 hours of use or annually, which ever comes first. Always fill the pump body with the liquid to be pumped before starting pump. It is not necessary to drain the pump body after use, unless there is a danger of freezing. Make certain that all hose and pipe connections are air tight. An air leak in the suction line may prevent priming and will reduce the capacity of the pump. Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy suction hose (made heavier when primed full of liquid) could result in a pump down the hole. There are important instructions regarding preparing the engine for long periods without use. (Read the engine instruction manual). Under these conditions, drain the pump and wet seal. Refill wet seal with fresh coolant mixture and reinstall fill and drain plugs. Leave all plugs (filter and drain) out of the pump. Always try to store the unit in a heated and dry building. When pumping dirty water or other liquids containing solids, always use a pump strainer on the end of the suction line. There are no points on the pump which need lubrication. The wet seal assembly is cooled and lubricated by the ethylene glycol/water mixture.

Disassembly Instructions: 1. Drain all fluids from the pump. Remove the drain plug (18003) from the lower front of the pump housing to drain the pump. Remove fill plug (18205) from top of reservoir. Remove drain plug (17032) from lower side of reservoir. 2. Using a 9/16" socket or wrench, remove the impeller clamp assembly (18129) from the pump. 3. Remove drive unit from the pump. This is done by using a 9/16" wrench to remove the four 3/8" bolts (17704) that hold the drive unit to the wet seal reservoir adapter (18203A). Once the bolts are removed, separate the drive unit from the pump. 4. Remove wet seal assembly from pump housing. This is done by removing the six 3/8" nuts (V20019) and 3/8" lock washers (V20018) from the wet seal reservoir adapter (18203A). The wet seal assembly can then be pried away from the pump housing and removed. Remove the handle (18033) from the wet seal adapter. 1

Disassembly Instructions: 5. Remove impeller (18206) from the wet seal assembly by pushing the wet seal shaft (18206) from the back of the assembly. 6. Remove cover plate (18202A) from the wet seal assembly. It may be necessary to pry the cover plate away from the reservoir by using the pry tabs located on the cover plate. 7. Remove the seal assembly (15035) from the wet seal assembly at this time. 8. Inspect the wear plate (18004) and replace or repair as necessary. 9. The inlet (18012) and outlet (18008) flanges and gaskets (18013, 18009) can be inspected and replaced as necessary. 2

Assembly Instructions: Clean all parts being reused in parts washing solvent before reassembly. Remove all remnants of old gaskets. Rinse and clean pump of all residue from liquids previously pumped. It may also be necessary to sandblast corroded components to remove rust from mating surfaces. 1. Install inlet (18012) and outlet (18008) flanges with new gaskets (18009 & 18013) as necessary. 2. Replace wear plate (18004) as necessary. It is highly recommended that the wear plate bolts be secured with Loctite 241 (blue). Securing the bolts in this fashion will not allow the bolts to vibrate loose during pump operation. 3. Install the ceramic/viton seal halves (15035) into the reservoir (18203A) and cover plate (18202A). Lubricate the O. D. of the viton seal with petroleum jelly and install the seal halves into the bores of the respective components by using a slight pressure with your thumbs. DO NOT STRIKE THE SEAL HALVES AT ANY TIME, OTHERWISE SEAL FAILURE WILL OCCUR. 4. A shim is used to set the clearance between the impeller and wear plate. Any shim with a thickness of.030/.040 can be used. An ideal shim is 1/2" wide piece of No. 21 gauge sheet metal. 3

Assembly Instructions: 5. Install gaskets to front and back of cover plate and install cover plate on the pump housing. 6. Install seal spring assembly on the impeller shaft. Lubricate the shaft and viton portion of the seal with petroleum jelly. Slide onto shaft using your thumbs. 7. Mate the reservoir adapter (18203A) with the cover plate (18202A). This is done by sliding the reservoir over the shaft and onto the cover plate. Align the bolt patterns of the two parts, also align the components such that the fill plug hole of the reservoir is facing up. 8. Install six 3/8 lock washers (V20018) and 3/8" nuts (V20019) onto the six wet seal housing studs and tighten. 4

Assembly Instructions: 9. Mate the wet seal and pump assembly to the drive unit. Insert the shaft of the drive unit into the wet seal shaft. Install four 3/8" bolts (17704) with lock washers (V20018) through the wet seal adapter and into the drive unit. 10. Install the impeller shaft clamp (18129) over the serrated tines of the wet seal shaft. Lubricate the clamp bolts with anti-seize thread lubricant and tighten to 40 ft.lb. minimum. It may be necessary to further tighten the clamp depending upon drive unit size and pump load during operation. 11. Fill the reservoir ¾ full with a 50% water & 50% ethylene glycol (anti-freeze) mix. The fluid level should cover the top of the seal assembly. Install the ¾" fill plug (18205) using a thread sealant. 12. Remove the shim from the pump. 5

70 301PIH13W FLOW DATA 160 60 140 50 120 PRESSURE (PSI) 40 30 100 80 60 HEAD (FT) 20 40 10 20 0 350 300 280 200 150 90 21 0 FLOW (GPM) 0 150 Banjo Drive 765-362-7367 765-362-0744 Crawfordsville, IN 47933 800-458-0232 sales1@banjocorp.com www.banjocorp.com