Pipette Controllers OPERATOR INSTRUCTIONS

Similar documents
Never charge the batteries with a charger other than that supplied by the manufacturer.

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.

CappController Pipette Controller. Operation Manual Version: 1.2.

9. WARRANTY INFORMATION

BlueSwan Pipette Controller

User s Manual. Pipette Controller for liquid handling. Thank you very much for purchasing Pipette Mate NEO.

Operation Manual for the Drummond Pipet-Aid XP

Tempo PIPETTE CONTROLLER USER GUIDE. Masters of precision

Bibbyjet Pipette Controller. Fingertip control... technology & ergonomics in harmony

Operation Manual for the Drummond Pipet-Aid XL

Operation Manual for the Drummond Hood Mate Pipet-Aid

Contents. Zippette Pro Bottle-top Dispensers Safetypette Pipet Filler...4. Zippette Pro Bottle-top Dispenser Accessories...

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

EDP 1. Multichannel Electronic Pipette with LTS LiteTouch Tip Ejection. Advanced Multichannel Pipette

Register your instrument! Easypet 3. Operating manual

Register your instrument! Easypet 3. Operating manual

LIQUID HANDLING TECHNOLOGY. User Manual Bedienungsanleitung

Register your instrument! Eppendorf Reference 2. Operating manual

electronic micropipettes

N) manual. Register your instrument! Eppendorf Reference 2. Operating manual

Register your instrument! Easypet 3. Operating manual

Operation Manual for the Drummond Pipet-Aid XL

SofTouch Electronic Precision Pipette Instruction Manual

N) manual. Register your instrument! Eppendorf Research plus. Operating manual

Liquid Handling Easy Handling! Transferpette -8/-12. electronic. Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo

Operating Manual. ali-q : Aliquoting Pipet Controller. or click here. or scan QR code

Liquid Handling Easy Handling! Transferpette. electronic. Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo

Premium Design - Premium Performance - Premium Quality

Easypet 3. Operating manual

Ultra. Pipetman. continuously adjustable digital microliter pipettes. 8 pipettes for volume ranges from 0.1 µl to 10 ml

Eppendorf Easypet. Operating manual

Digital Burette. Assembly and operating instructions. For capacities of 30ml & 50ml

PNEUTORQUE STANDARD & SMALL DIAMETER SERIES STALL TOOLS

TopPette Mechanical Pipettes

Phone: Fax: More information:

HDE 500-A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Automatic Industrial Cordless Brushless Power Torque Screwdrivers Series

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!

eline Electronic Pipette

Prospenser. User Manual Mode d emploi Bedienungsanleitung Manual Usuario. For capacities of 2.5 ml 5 ml 10 ml 30 ml and 50 ml

The Proven Industry Leader in Ergonomics and Accuracy. The VWR UHP Pipettor was superior in all of the test categories.

TPC. User Manual LED 55N. Cordless LED Curing Light. All instructions in this USER S MANUAL must be completely read before installation or operation.

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

12 amp RMS Battery Charger

Instruction Manual Bedienungsanleitung Mode d emploi Manual de Instrucciones Instruzioni d impiego BIOH T

4 ual Repeater M4. N) manual. Register your instrument! Multipette M4 Repeater M4. Operating manual

PNEUMATIC PUMP Series

USER'S GUIDE 9151 SERIES V

Eppendorf Repeater Pro Instruction Manual Manual de Instrucciones

Ballotini Grade Solid Soda Glass Balls $53.33 KG Laboratory glass filters

N) manual. Register your instrument! Eppendorf Research plus. Operating manual

User Manual dpette+ Electronic Pipette 2016-ver.1

Perfection in Liquid Handling PRECISE AND CONVENIENT PIPETTING

N) manual. Register your instrument! Eppendorf Research plus. Operating manual

Operation Manual BOTTLE TOP DISPENSER

SmartVent. Instructions for Use Version 4 (Dec 2009)

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

4V LITHIUM-ION SCREWDRIVER OWNER S OPERATING MANUAL

Pro Gun (Model: UCpro and UCPro Plus)

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Cordless High Speed Drill

Cordless Screwdriver

AquaLift Bath Lift System MODEL #8100

multi Mid. vol. Max. vol. Min. vol. < 3.0% 1) < 1.0% < 0.6% < 0.6% < ± 1.5% < ± 0.8% < ± 0.7% < ± 0.8% < ± 1.5% < ± 0.8% < ± 0.7% < 1.0% < 0.

JADE Bottle Top Dispenser

PRIEMONIŲ IŠPARDAVIMAS

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

Operating instructions 1 4 Mode d emploi 5 8 Instrucciones de uso 9 13 Manual de instruções 15 18

Single Unit Rapid Charger FOR RECHARGEABLE TWO-WAY RADIO BATTERIES

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

Picus Electronic Pipette

Single and 8-channel Electronic Pipettes. Operation Manual Version: 2.9

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING ON/OFF/REGULATING NAMUR SOLENOID VALVE MODEL 30318, 30318LW

FSG175 FENCE STAPLE GUN

Multipette /Repeater (X)stream. Operating manual

DURAN GROUP DISPENSER & DURAN GROUP DISPENSER PRO. A safe and precise dispensing system

SILVAN AUSTRALIA PTY. LTD.

Plunger Heads Use and Maintenance Manual

SPARK PLUG CLEANING KIT OPERATING MANUAL

PNEUTORQUE PTM, PTME & TRUKTORQUE TM SERIES STALL TOOLS

Operating Instructions

USER S GUIDE (For Tronix Explorer XT / Tronix Explorer XT SE)

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

Sonic Meter. Soni. Operating Manual. Rev. A

PT-1441 Cordless Drill Driver 14.4V User s Manual

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Operating Instructions. International English. CCS Dust Extractor

Printed: Doc-Nr: PUB / / 000 / 00

Picus Electronic Pipette

Centrifuge Operator / Service Manual

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

frontlineclassic The original low volume TDC herbicide application system INSTRUCTIONS

Operating instructions ErgoPack 600 E

Endodontic Handpiece (GT) USER MANUAL

PSU1 Power Supply Unit

PA 5000 INSTRUCTION MANUAL

Transcription:

Pipette Controllers OPERATOR INSTRUCTIONS

Introduction GlassMaster has been carefully designed and manufactured as a lightweight, cordless pipetting aid for use with all plastic or glass pipettes from 1 100ml. The Turbo GM-200 model has a more powerful motor, with a yellow nose cone for easy identification. The Turbo GM-200 model fills and dispenses faster, especially useful when using pipets with volumes from 25 ml to 100 ml range (like the GM-100 model it can be used with all types of pipet from 1 100 ml). At the fastest speed setting the GM-200 fills a 25 ml pipet in less than 3 seconds. GlassMaster is constructed of recyclable materials and operates on two rechargeable, long life, environmentally friendly, 1.2V NiMH batteries. GlassMaster has uniquely formed finger triggers to minimize any high pressure points. These triggers also control intake and dispense speeds. A battery warning light (4) is triggered whenever the charge in the batteries is low. Pipetting with GlassMaster can also take place while the units are connected to their chargers (5). GlassMaster has a a conveniently located slide switch (3) which allows selection between three modes of operation. HIGH Aspiration and dispense at full speed (includes Blow-out) LOW Aspiration and dispense at reduced speed (includes Blow-out) G Aspiration at reduced speed, dispense by gravity (To Deliver) Technical Data Batteries Battery service Life Charger Overall weight Filter (8) Manifold and Case Material 2 x 1.2V nickel metal hydride 500 1000 cycles from empty 65mA /H for 14 hours plug-in 180g without stand Hydrophobic 25 mm dia 0.45 mm (fitted) plus two additional spare filters 1x 0.45 µm and 1x 0.20 µm ABS Nosecone material Polypropylene (10) Pipette holder Silicone (9) Pipette types Plastic or glass 1 100 ml

Low battery indicator Aspirate trigger Dispense trigger Filter adapter Mode selection slide switch Filter Charger Silicone pipette holder Polypropylene nosecone Charging jack Each GlassMaster Pipette Controller is shipped with: Charger; Appropriate voltage: 120V 60Hz 2-pin (USA), 230V 50Hz 2-pin (EU),230V 50Hz 3-pin (UK) Two spare hydrophobic filters, 1x 0.45 µm and 1x 0.2 µm Bench stand, Instruction manual Safety GlassMaster is designed with safety in mind. Light in weight, it balances easily and safely in the hand. The triggers are carefully designed to eliminate pressure points and control of intake and delivery is therefore made easier. When using aggressive liquids you should wear protective clothing, including goggles and gloves. If in doubt ask your safety officer. Please consult and establish appropriate health and safety practices applicable to the liquid being dispensed within your working environment. 1

WARNING! Only use this instrument within recommended limits of its chemical resistance. Never use GlassMaster with fuming liquids that are incompatible with polypropylene or silicone. Never use with highly inflammable liquids. Observe the reagent manufacturer s safety information. Never use GlassMaster in an atmosphere where there is a danger of explosion. When not in use store on bench stand. Never use force when in use. If the instrument fails to perform to specifications stop work and check Troubleshooting (page 4). Only recharge with the original charger supplied by RAININ. All repairs must be carried out by RAININ or an authorized distributor. Use only the accessories and spare parts supplied by RAININ. See page 5. Recharging GlassMaster Before starting to operate carefully check the line voltage and recharge batteries. To charge GlassMaster 1. Recharging temperature +10 C to +35 C 2. Plug the charger jack (6) into the base of GlassMaster. 3. Plug the charger (5) into a suitable wall socket. The indicator on the charger will light up. 4. Place GlassMaster onto bench stand 5. Allow unit to charge for 14 hours from empty to fully charged. 6. When GlassMaster is fully charged, the charger automatically switches to a trickle charge operation and the indicator will turn off. If the charge to GlassMaster is interrupted and then re - started, the charger starts its full 14 hour charging cycle again. This will not damage the battery. Only use the charger indoors and protect against moisture. 2

Cleaning GlassMaster can be cleaned with most common laboratory disinfectants. The polypropylene nose cone (10) and silicone pipette holder (9) can be autoclaved. To remove the nose cone and pipette holder turn the nose cone counter-clockwise. When the nose cone is removed the silicone pipette holder can also be disengaged from the filter by gently turning. Replacing the Filter The hydrophobic filter (8) will require occasional replacement, particularly when suction capacity is slowing. Note Only use genuine manufacturer s recommended filters and accessories as listed on page 5. 3

Pipetting To aspirate 1. Carefully hold the pipette and insert it securely into the polypropylene nose cone and silicone holder. 2. Select mode of operation High, Low, or G. 3. Depress upper trigger (1) (The harder the pipetting triggers are pressed the faster the aspiration.) To dispense 1. In BLOW-OUT mode, (mode switch high or low) depress the lower trigger (2) (The harder the pipetting triggers are pressed, the faster the dispense). 2. If G gravity mode is chosen, the upper aspirate trigger automatically operates at low speed while the lower trigger opens the pipette to atmosphere, allowing liquid to run out. WARNING! Please ensure that no liquid enters the instrument. GlassMaster should never be used without the filter (8). The filter also prevents liquid from entering the instrument. Where liquid has entered please clean and replace filter. Trouble Shooting TROUBLE POSSIBLE CAUSE REMEDY Suction capacity slow Filter blocked, dirty or damaged Clean or replace membrane filter Batteries low Recharge Pipette drips Pipette not securely positioned in Re-attach holder silicone pipette Pipette holder or pipette damaged Replace GlassMaster is virtually service-free. If the recommendations above do not resolve the problem, please contact your RAININ or your authorized distributor. 4

Note When the meniscus level has been reached liquid should not drip out of the pipette. If the pipette does drip, check that the adaptor assembly and filter are correctly assembled and the pipette is properly located in the silicone pipette holder. Return for Repair In the unlikely event of repair, or where damage to the unit is indicated, return to RAININ or to your distributor. Make sure that you decontaminate the unit and complete the required decontamination certificate where appropriate. Please also give details of the fault. Voltages US Europe Japan 120V 60Hz 2-pin 230V 50Hz 2-pin 100/120V 50/60Hz 2-pin Ordering Information GlassMaster Pipette Controller Cat. No. GM-100 GM-200 Accessories Description GlassMaster Pipette Controller (1 to 100 ml) GlassMaster Turbo Pipette Controller (25 to 100 ml) Cat. No. Description Quantity GM-045 Filter set, 0.45 µm Pkg. of 5 GM-045S Filter set, 0.45 µm, Sterile Pkg. of 1 GM-020 Filter set, 0.2 µm Pkg. of 5 GM-PH Silicone pipette holder Pkg. of 1 GM-NC Nose cone, mint Pkg. of 1 GM-NCY Nose cone, yellow for Turbo Pkg. of 1 GM-B Battery for GM-100, GM-200 Pkg of 2 Sterile Disposable Plastic Serological Pipettes Cat. No. Volume Grad. Interval Plug Color Qty/pkg SP0010-S01 1 ml 0.01 Yellow 500 SP0050-S01 5 ml 0.10 Blue 250 SP0100-S01 10 ml 0.10 Orange 200 SP0020-S01 2 ml 0.02 Grn 500 SP5000-S01 50 ml 1.00 Purple 100 Note: All standard GlassMaster accessories and filters fit the Turbo model.

7500 Edgewater Drive, Box 2160 Oakland, CA 94621-0060 510-564-1600 e-mail: pipets@rainin.com Website: http://www.rainin.com GlassMaster is a trademark of Rainin Instrument, LLC 1997-2003 Rainin Instrument,LLC a METTLER TOLEDO Company GlassMaster is CE marked to Low Voltage Directive 73/23/EEC and Electromagnetic Compatibility Directive 89/336/EEC 9920-226 Rev D