Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

Similar documents
For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h

LEF/MEF LEX/MEX ATEX versions

FEATURES & BENEFITS UPON REQUEST

NCF 60 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55

VORTICENT C E RANGE Centrifugal fans

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

NCF fans 60Hz. Protection class IP 55

V. Aa. Gram A/S

V. Aa. Gram A/S

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

AXIAL FANS Catalogue CN0050C01 May 2008

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Small centrifugal fans made of plastic

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h

Powerful centrifugal fans for universal use: The product ranges TEM and REM

HIGH-POWERED VENTILATORS

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

AC Commercial Fans Edition. ErP ready

Centrifugal fan with highly efficient EC drive motor

A Full Line of Low Voltage IEC Motors In-Stock

AXIAL FANS Axis / Tubo OPERATION MANUAL

RADIAL STEEL HIGH PRESSURE RHD 5/ RHD 4/ RHD 8/ RHD 11/ RHD 9/ RHD 13/ CAS... 8 CAM ACCESSORIES...

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

c-go 24V/6A 24V/8A 24V/12A

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

Powerful centrifugal fans for universal use: The product ranges TEM and REM

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size (14.1) 55 (32.4) 100 (58.9) Air volume (with exhaust filter installed)

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SITESTAR ELECTRONICS CABINET DESCRIPTION

Short casing. Long casing (L version) Commercial premises

Multifunctional 400ºC/2h and 300ºC/2h roof fans

SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT

CGT Series Adjustable Pitch Fans

3D drawings available at Kg GAS-NPT thread adapters available at page 1.117

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

CGT Series Adjustable Pitch Fans

A new dimension ZPF 9H the central suction and filter unit

ACOUSTIC CABINET FANS CVB / CVT Series

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

Air flow management. Fan Filters Introduction

Centrifugal Utility Fans - SFD/SFB

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Bifurcated Case Axial Fans (BIFA)

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

MULTI-FLUID SOLENOID VALVES 1/8 AND 1/4

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Operating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1

Ventilation Blowers 09. Introduction Heavy Duty Radial Blowers Radial Blowers In-Line Blowers

About Dustcontrol Filter Units

QUBE SQU-HT(S) Product Brochure

CYLINDRICAL CASED AXIAL FLOW FANS

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Explosion and flame-proof single phase electric motors

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

NB /193 A-F2-A-BAQE

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

Multi-Mover Charger for model L25

Explosion and flame-proof cast iron electric motors

Section 4. Axial Fans - Section 4

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

ACOUSTIC CABINET FANS CVAB / CVAT Series

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

V High Efficiency Series

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

1 / Genset general description

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Medium Pressure Centrifugal Fans

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS

Catalog. Low voltage General performance IE2 high efficiency motors according to EU MEPS

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

F a n t y p e s J K K - J K K

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

A Smarter Breed. of Centrifugal Fans

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Position Switches Series 8074/2

Transcription:

Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h Max. dust volume: 5g/m³, non-sticky Max. particle size: 5x5x5mm, non-sticky Temperature: Extracted air (transport air in fan) = max. 60 C Ambient temperature: max. 40 C Fan order no. Achieved efficiency Efficiency category Measurement category Efficiency grade VSD Production year Manufacturer Rated motor power input, flow rate and vacuum at optimal efficiency kw m³/h Pa (Ps) Rpm. Specific ratio Model number/type Disposal Environment Mounting measurement 03 013 000 43,0 D Total NO CE-mark 0.B4 VL 550-C2 0,61 750 1235 2867 1,01 0.B4 0.B4 0.B4 03 006 000 50,1 D Total NO CE-mark 0.B4 VL 750-C2 0,84 930 1600 2887 1,02 0.B4 0.B4 0.B4 03 008 000 52,0 D Total NO CE-mark 0.B4 VL 1100-C2 1,07 1435 1370 2902 1,02 0.B4 0.B4 0.B4 03 009 000 64,0 D Total NO CE-mark 0.B4 VL 1150-C2 1,51 1700 1815 2846 1,02 0.B4 0.B4 0.B4 03 008 300 33,3 D Total NO CE-mark 0.B4 VL 1100-C4 0,21 639 385 1484 1,00 0.B4 0.B4 0.B4 No approved according to EU327/2011 ERP 2015 May be mounted on clean air side of Gram filter units as transport fan according to EU 327/2011 and EN 13349/2010 Construction: Radial fan with closed fan wheel mounted in welded steel cabinet and with directly coupled motor. Model: Wheel: C (Transport of dust) Fan wheel type P-G, closed wheel with backward straight, self-cleaning blades Static/dynamically balanced according to ISO 14694 (BV3 G 6.3) Housing: Welded in 2mm steel plate Fan housing can be mounted with various inlet positions (RD0, RD90, RD180, RD270) Standard enamelling: Powder enamelled for indoor mounting (RAL 5007), for outdoor placement galvazing is also recommended Motor: IE3 at > 0.75kW / IE1 or IE2 at < 0.75kW B5 flange motor without bimetallic sensor 3x400V 50Hz (three-phased motors can be frequency regulated) Fan type VL-C is also available galvanized and spark-protected (copper ring in inlet) For ATEX fans - see group 10 Constructed and tested according to: Machine Directive 2006/42/EU Electromagnetic Compatibility (EMC) Directive 2004/108/EU Low Voltage (LVD) Directive 2014/35/EU Harmonized standards: EN 12100, EN 60204-1, EN ISO 13857, ISO 12499 Further standards: ISO 3746, ISO 5801 As well as: EU Regulation no. 327/2011 (ERP 2013 and 2015) 3.VLC1

Volt [V] [rpm.] [kw] Max. amp. Start current VL 550-C2 03 013 000 3x400 2-pole 0,55 1,35 5,80 19,0 VL 750-C2 03 006 000 3x400 2-pole 0,75 1,90 9,50 19,0 VL 1100-C2 03 008 000 3x400 2-pole 1,10 2,70 14,90 23,0 VL 1150-C2 03 009 000 3x400 2-pole 1,10 2,70 14,90 23,0 VL 1100-C4 03 008 300 3x400 4-pole 0,55 1,60 9,60 21,0 Weight [kg] Motor data > 0,75kW, 3x400V, according to IE3-motors. A B C D E F G H I VL 550-C2 03 013 000 545 331 236 520 ø160 92 ø160 87 369 VL 750-C2 03 006 000 531 302 253 488 ø160 95 ø160 90 412 VL 1100-C2 03 008 000 531 302 253 488 ø200 104 ø200 107 484 VL 1150-C2 03 009 000 575 333 274 613 ø200 130 ø200 102 438 VL 1100-C4 03 008 300 531 302 253 488 ø200 104 ø200 107 484 Please, note: Connection measurements are nipple measurements 3.VLC2

3.VLC3

1400 rpm.: 3.VLC4

EQUIPMENT FAN All versions of fan type VT-O is also available i a galvanized version spark protection in copper (Cu) on inlet! Sound enclosure type VB*: (Position RD0) VL 550 03 182 000 VL 750 03 181 000 VL 1100 03 188 000 VL 1150 03 183 000 Additonal payment for sound enclosure type VB with side outlet, fan position RD0 * Only for clean air transport 03 550 000 Weather-protected cover for air cooling intake and out for elecktro motors: VL 550 03 013 800 VL 750, VL 1100, VL 1150 03 030 800 Fan wheels: Hub [mm] Fan type** [Hz] VL 550 ø14 C2 50 03 034 205 VL 750 ø19 C2/C4 50 03 002 005 VL 1100 ø19 C2/C4 50 03 008 005 VL 1150 ø19 C2/C4 50 03 009 202 **Closed Transport Futher is available: Pressure guard Mounting fittings Vibrations absorbers Safety grid FLEX flexible connections Explosion-protected construction for application in ATEX zones Motor starter Y-D Frequency converter Foto: ABB Frequenzumrichter Typ ACH 580 3.VLC5