Technical Application Guide for UP-SHINE LED Downlight UP-DL36-42W(1 inch)
Introduction Up-shine DL36 downlight retrofit kits are designed with CREE COB LED chip, utilization of high efficient reflector helps to improve lumen output. 4inch, 6inch 8inch and 1inch full sizes with wattage varies from 15W to 5W for different applications. -1V dimmable driver works with most of the local dimmers. UL&cUL and energy Star approved, qualified for North America Market. Up to 7% energy saving compared to standard CFL Long lifetime of 36, hours ~1V dimming driver 4 wide beam angle CCT: 27K 3K 4K 5K No UV/IR light Environment friendly, without Mercury or any other hazardous substances Application notes IP2 for indoor use Professional electrician for installation only Switch off before installation Do not touch when in use Keep away from hot steam and corrosive gas Application Areas It is designed for general lighting applications in office, supermarket, shop, school, hotel, etc. It is also widely used for public areas, such as stairway, lobby, reception, corridors etc. Certificate
Product Information Ø233 Ø276 Technical Specifications 235 Model Voltage Power Power Factor Lumen (±5%) Beam angle CCT Lifespan CRI Dimmable Dimension UP-DL36-42W AC1-277V 42W.9 32 4 o 27K 36h 83 Yes Ø276*235mm UP-DL36-42W AC1-277V 42W.9 33 4 o 3K 36h 83 Yes Ø276*235mm UP-DL36-42W AC1-277V 42W.9 35 4 o 4K 36h 83 Yes Ø276*235mm UP-DL36-42W AC1-277V 42W.9 35 4 o 5K 36h 83 Yes Ø276*235mm Driver data Sheet Driver data DIM Input rated Voltage Frequency Input Voltage AC1-277V 5/6Hz AC9-35V Efficiency 85% Total load Wattage 42W±5% Power Factor.9 Rated input current Full load output Voltage Rated output current Output current range A DC35-38V 1mA 1mA±5% Power tolerance ±5% Current output tolerance ±5% Dimming range 8%-1% Dimmer Short circuit protection Over voltage protection Over temperature protection Withstand voltage V-1V dimmers PASS PASS PASS AC375V Fixture Compatibility Rated Wattage Electrical Classification Ingress Protection Operating Temp Operating Humidity Storage Temp 42W Ⅱ IP2-2 o C~45 o C ~9% -2 o C~65 o C
Spectral Distribution 27K 3K Max=6788 [1.=2] 1.13SDCM F27K Max=5338 [1.=2] 3.5SDCM F3K x=439 y=656 x=464 y=49 4K 5K Max=7171 [1.=2] 2.12SDCM F4K Max=8694 [1.=2] 2.5SDCM F5K x=841 y=816 x=473 y=564 Photometric Diagram 27K 3K -9 9 24 36 48 6-3 3 AVERAGE BEAM ANGLE(5%): 4 DEG MH=1m 6 C/18 C9/27 54 48 42 36 3 24 18 12 6-25 -2-15 -1-5 5 1 15 2 25 Flux out: 1646 lm 3.281ft 43, 617.2fc 2.157ft 1m 4489, 777lx 67.93cm 6.562ft 12.5, 168.7fc 4.335ft 2m 1157, 182.4lx 131.71cm 9.843ft 48.9, 72.44fc 6.74ft 3m 523.47, 84.6lx 222.2cm 13.12ft 26.97, 41.2fc 13ft 4m 287.41, 456.1lx 297.81cm 16.4ft 17.11, 27.4fc 14ft 5m 184.69, 295.8lx 333.88cm Height Eavg, Emax Angle: 39.3deg Diameter -9 9 24 36 48 6-3 3 AVERAGE BEAM ANGLE(5%): 4.9 DEG MH=1m 6 C/18 C9/27 54 48 42 36 3 24 18 12 6-25 -2-15 -1-5 5 1 15 2 25 Flux out: 168 lm 3.281ft 337.1, 52fc 2.431ft 1m 3629, 564lx 74.1cm 6.562ft 84.28, 13fc 4.862ft 2m 97.2, 141lx 148.19cm 9.843ft 37.46, 57.85fc 7.299ft 3m 43.2, 622.7lx 222.29cm 13.12ft 21.7, 32.54fc 9.724ft 4m 226.8, 35lx 296.38cm 16.4ft 13.48, 22fc 12.15ft 5m 145.1, 224.2lx 378cm Height Eavg, Emax Angle: 46deg Diameter 4K 5K Flux out: 1856 lm Flux out: 17 lm -9 9 7 63 56 MH=1m C/18 C9/27 3.281ft 414.2, 624.7fc 1m 4459, 6724lx 6.562ft 13.6, 156.2fc 2m 1115, 1681lx 2.351ft 71.65cm 4.71ft 143.29cm -9 9 65 58.5 52 MH=1m C/18 C9/27 3.281ft 379.5, 588.8fc 1m 485, 6337lx 6.562ft 94.88, 147.2fc 2m 121, 1584lx 2.323ft 72cm 4.647ft 141.63cm 14 49 13 45.5 28 42 35 9.843ft 46.3, 69.41fc 3m 495.4, 747.1lx 7.52ft 214.96cm 26 39 32.5 9.843ft 42.17, 65.42fc 3m 453.9, 74.1lx 6.97ft 212.45cm 42 56 28 21 13.12ft 25.89, 39.4fc 4m 278.7, 42lx 9.42ft 286.58cm 39 52 26 19.5 13.12ft 23.72, 36.8fc 4m 255.3, 396.1lx 9.294ft 283.27cm -3 7 3 14 16.4ft 16.57, 24.99fc 5m 178.3, 269.lx 11.75ft 358.23cm -3 65 3 13 6.5 16.4ft 15.18, 23.55fc 5m 163.4, 253.5lx 11.62ft 354.9cm AVERAGE BEAM ANGLE(5%): 39.5 DEG -25-2 -15-1 -5 5 1 15 2 25 Height Eavg, Emax Angle: 39.42deg Diameter AVERAGE BEAM ANGLE(5%): 39.1 DEG -25-2 -15-1 -5 5 1 15 2 25 Height Eavg, Emax Angle: 39.deg Diameter
Polar Diagram Comparison -15 O +/-18 O 15 O O O -9 O 9 O 13 26-6 O 39 6 O 52-3 O 65 3 O O AVERAGE BEAM ANGLE (5%): 39.8DEG C/18, 39. deg C3/21, 39.1 deg C6/24, 39.2 deg C9/27, 39.2 deg Driver lifetime & LED light decay rate Driver Lifetime LED Light Decay Rate 9 11% 4 Lifetime (hours) 8 7 6 5 4 3 2 1 65 o C 75 o C 85 o C 95 o C 15 o C Capacitor Tc ( o C) % Luminous Flux 15% 1% 95% 9% 85% 35 3 25 2 15 8% 75% FLUX 1 5 U'V' 7% 1 2 3 4 5 6 7 8 9 1 LifeTime (hours) Temperature The testing is operated at 25 C The lifetime of capacitor, minimum of 5, hours if operated at 15 C, will be doubled whenever the temperature drops 1 C The highest withstand temperature of IC, MOS could be C The highest withstand temperature of LED junction temperature is 15 C Temperature ( o C) 9 8 7 6 5 4 3 2 1 11:13:13 11:25:1 11:37:1 11:49:1 12:1:1 12:13:1 12:25:1 12:37:1 12:49:1 13:1:1 13:13:1 13:25:1 13:37:1 13:49:1 14:1:1 14:13:1 14:25:1 14:37:1 14:49:1 15:1:1 15:13:1 15:25:1 15:37:1 15:49:1 16:1:1 16:13:1 16:25:1 16:37:1 Time IC Capacitor MOS PCB LED Fitting Environmental temperature The driver lifespan is based on capacitor working temperature.
Installation NOTE: RETROFIT KIT IS VOLTAGE SPECIFIC. VERIFY PROPER VOLTAGE BEFORE INSTALLATION. Step 1: Remove existing lamp(s) Step 2: Remove and discard existing reflector. Step 3: Open board of side of J-box. Step 4: See 4A and 4B Locate J-box containing supply wires and cut all supply wires leading to the ballast and output lead of ballast. (May remove wires of ballast) Step 5: Twist out conduit knockout. Step 6: Place LED Driver box thru ceiling cut-out and allow to rest on ceiling. Step 7: Install the supply conduit of Driver Box into the junction box. Step 8: Connect the supply to the LED Driver. Connect GND to wire of green. Step 9: See figure 9, hold the end of the string and pass through the hole on one side of the fixture. press a while penetrate though the hole inside, and make it tighten. (please clarify where the wire is tighted and the tool is not described) Step 1: Plug the yellow connector of new LED engine to the yellow connector on the end of the flex conduit provided on the driver box. Step 11: Plug the connector of metal to hole of LED engine. Step 12: Ensure the mounting frame can hold the weight of the whole reflector. Step 13: Restore power after installation of fixture is completed. Step 14: After modification completed, attach the Lamping Replacement Marking Label and Cautionary Label which provided with the retrofit kit package to the light fixture. The label shall be visible during relamping, and after installation. Step 2 Step 3 Step 4a Step 4b Step 5 Step 6 Step 7 Step 8 Step 9 Step 1 Step 11 Step 12
Retrofit Kit Contents A A Engine and Light Source B Reflector B C C LED Driver Box Packaging Information SIZE(CM) N.W/pc (KGS) G.W.(KGS) Q'TY(PCS) Carton 68.5*68.5*29 2.1 9 4 CTNS Q'TY(PCS) VOLUME(CBM) 2'' standard container 2 8 28 4'' standard container 4 16 56 Phone: +86 755 2919 7389 Add: 2nd building Dingfeng High-Tech Zone, Fuyuan 1st road, Fu Yong Sub-district, Bao'an, Shenzhen China