Explosion-protected surface-mounting Thermostat ATH-Ex Series

Similar documents
Thermostats for panel mounting Series ETH

Surface-mounting Thermostats Series ATH-SW

JUMO heattherm Type a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature

Panel-mounting Thermostats EM Series. B Operating Instructions 11.06/

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

Pressure Transmitter JUMO dtrans p30 Type

JUMO BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

J TS 7090 Thyristor power switch

Products Temperature, Control, Monitoring

Contact dial thermometer

Panel-mounted Thermostats

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

Pressure transmitter JUMO dtrans p02

JUMO heattherm-at and JUMO heattherm-dr

Contact Dial Thermometer

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

Rod thermostat with micro switch

EX-REPAIR AND MAINTENANCE RECEPTACLES

Ball valve for pipeline systems

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Automation Temperature, Control, Monitoring

Panel-mounting thermostats

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Analog input module. Brief description. Page 1/8. Data Sheet

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Measuring Cells for free chlorine, chlorine dioxide, ozone

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

HTSB system System overview

JUMO dtrans p20 DELTA

Process Connections for Dial Thermometers

Limit Switch Type 4747

10 Load and Motor Switchgear

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

TER. Thermostats for Industrial Applications. Switching range: C to C. Housing material: aluminium. Capillary tube: copper

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Pressostats and thermostats CAS

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I Ex-Safety switches I

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Pressure switch and Thermostat Type CAS

Pressure and temperature controls, Type CAS

A good connection. International approvals.

Unused flameproof threads for cable glands have to be closed with certified plugs.

International approvals.

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Solenoid Valve Island Type 3965

Ex m Solenoid Operator Type 0519

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Room thermostats type series TRM

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Series 3730 Electropneumatic Positioner Type

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

Technical Data Sheet

I Ex-safety switches I

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Point level measurement Capacitance switches

Load disconnect switch Series 8146/5-V11

Cable resistance thermometer Model TR40

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

Rod thermostats (without immersion tube)

Temperature controller- and limiters

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Linear fluorescent luminaire LED V-CG-S

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

JUMO dtrans p20 DELTA Differential pressure transmitter Type

Resistance thermometer Model TR10-E, for additional thermowell

Solenoid Operator 0516 / 1216

Terminal Boxes TNCN. Explosion protection Marking

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Product specification

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

Product specification

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Level Measurement based on Archimedes Principle. Device Description

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Cable resistance thermometer Model TR40

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Differential Pressure Switch QBM81-

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

YFC. Limit switch. Ex d. 24 operating head types

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Thermocouples Model TC10-B, for Additional Thermowell

Product specification

Pressure controls and thermostats, type KPS

Resistance thermometers approved to DIN 34 40

Internationally approved.

Transcription:

JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO PROCESS CONTROL INC. 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 e-mail: info@jumousa.com Internet: www.jumousa.com Data Sheet 60.5041 Page 1/5 Explosion-protected surface-mounting Thermostat ATH-Ex Series EC type examination to ATEX Directive 94/9/EC for explosive gas atmosphere Zone 1 and explosive dust atmosphere Zone 21 TW temperature monitor STW fail-safe temperature monitor Brief description Explosion-protected surface-mounting thermostats in the ATH-Ex series control and monitor thermal processes. They can be used directly in the hazardous area (zone 1 and zone 21). The thermostats are available both as temperature monitor TW and temperature monitor STW (fail-safe). Ex thermostats operate on the principle of liquid or gas expansion. The electrical switching device is a microswitch inside a flameproof enclosure. Ex marking II 2G EEx ed IIC T6 for explosive gas atmospheres II 2D IP65 T80 C for explosive dust atmospheres Explosion protection II 2G Equipment group II, Category 2, Equipment for explosive gas atmospheres II 2D Equipment group II, Category 2, Equipment for explosive dust atmospheres Type of explosion protection: EEx ed IIC T6 EEx General requirements Euronorm EN 50 014 / VDE 0170 / 0171 Part 1 e Increased safety Euronorm EN 50 019 / VDE 0170 / 0171 Part 6 d Flameproof enclosure Euronorm EN 50 018 / VDE 0170 / 0171 Part 5 IIC Gas group T6 Temperature class IP65 T80 C Application in combustible dusts Euronorm EN 50 281-1-1 / VDE 0170 / 0171 Part 15-1-1 IP65 T80 C Protection to EN 60 529-IP65 Max. permissible surface temperature (use in combustible dusts) Switching action Temperature monitor TW and fail-safe temperature monitor STW If the temperature at the probe exceeds the selected setpoint, the microswitch is operated through a mechanism, and the circuit is opened or closed. If the temperature falls below the selected setpoint (by the amount of the switching differential), the microswitch returns to its initial position. Self-monitoring facility on the fail-safe temperature monitor STW A failure of the measuring system, i.e. when the expansion liquid escapes, will cause the pressure under the diaphragm to drop (STW), thus permanently opening the circuit. The thermostat can no longer be reset. If the probe cools down to a temperature in accordance with the control range table, e.g. below -20 C, the circuit will also open. The STW is reset automatically.

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 60.5041 Page 2/5 Types and approvals Type Switching action Test certificate Test DIN Reg. No. TW TW 76602 Pressure Equipment PTB 03 ATEX 1167 Directive 97/23/EC STW ( only) STW (STB) 76702 Technical data Control ranges and probe table Control range C -20 to +050-20 to+050-20 to+100 +40 to +120 +50 to +200 +80 to +250 +50 to +300 +20 to +400 +20 to +500 Switching point accuracy in upper third of scale * Maximum capillary length mm Maximum probe temp. to DIN 3440 C * The switching point accuracy can be shifted to a different part of the scale, to special order. STW opens at probe temp. below ( C): Probe length L for d = 6 mm TW STW TW STW - 03,0 C - 02,0 C - 04,0 C - 03,0 C - 06,0 C - 07,0 C - 10,0 C - 15,0 C - 19,0 C - 03.5 C - 02.5 C - 05,0 C - 04,0 C - 08,0 C - 08.5 C - 12.5 C - 19,0 C - 24,0 C 5000 +060-30 153 132 +060-10 202 172 +115-10 117 102 +140-10 135 117 +230-10 107 094 +300-20 090 078 +345-30 067 060 1000 +460-30 - - - 202 2000 +550-30 237 149 Capillary and temperature probe Type End of scale Capillary 1.5mm dia. Temperature probe Notes up to 200 C brazed Capillary length Min. bending radius of capillary Electrical data up to 300 C up to 500 C up to 300 C brazed welded welded 1000 mm is standard, max. 5000 mm Switching device microswitch in flameproof enclosure with changeover contact Contact rating 5 A, 230 V AC +10%, p.f. 0.9 Electrical connection screw terminals in housing, suitable for conductor cross-section up to 2.5 mm 2 5mm at extra cost

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 60.5041 Page 3/5 Operating data Switching differential in % of control /limit range Ambient temperature error referred to control /limit range Permissible storage temperature Permissible ambient temperature in operation Nom. position (NL) Ranges with end of scale 350 C Ranges with end of scale > 350 C Switching action Nominal value Possible measured value Switching action Nominal value Possible measured value TW 3 3-5 TW 5 5-9 STW 5 5-7 STW 6 6-11 A deviation of the ambient temperature at the housing from the calibrated ambient temperature 22 C will result in a displacement of the switching point: higher ambient temperature = lower switching point lower ambient temperature = higher switching point surface-mounting thermostats with end of scale < 200 C 200 C 350 C > 350 C 500 C TW STW (STB) TW STW (STB) TW STW (STB) on thermostat head %/ C 0.08 0.17 0.06 0.13 0.14 0.12 on capillary %/ C per meter 0.047 0.054 0.09 0.11 0.04 0.03 Capillary -50 to +50 C Thermostat head max. +50 C +50 C min. with end of scale -40 C -20 C < 200 C -20 C -20 C 200 C 350 C -40 C -20 C > 350 C 500 C to DIN 16257, NL 0 NL 90 (other NL on request) Housing Material Limit setting Protection Cable entry Weight Thermostat mounting black polyester housing, glass-fiber reinforced, with lead-sealable screws limit adjustable at setpoint spindle, after removal of housing cover EN 60 529-IP65 Ex cable gland M 20 x 1.5, for cable diameters 6 12 mm approx. 0.6 kg by 4 screws, after removal of housing cover Process connection* Series with capillary Material Pocket U Fitting length S Immersion tube dia. plain cylindrical probe A (standard) pocket U (on request) screw-in pocket with screw-in spigot G 1/2 Form A to DIN 3852/2 and clamping clip with fixing screw for securing the probe up to +150 C: CuZn is standard above +150 C: St is standard (CrNi on request) standard lengths: 100, 120, 150, 200 or 300 mm (other lengths on request) D = 8 mm *for other process connections and pockets, see Data Sheet 60.6710 (US, UO, Q and V only). Note Physical and toxicological properties of the expansion media that may escape in the event of a measuring system fracture. Control range with end of scale 1) At present there is no statement from the health authorities concerning any danger to health over short periods and at low concentration, e.g. after a fracture of the measuring system. Dangerous reactions Fire/explosion hazard Ignition temp. C Explosion limit %v/v Water contamination irritant Toxicological data danger to health < +200 C no + 355 0,6 8 yes yes 1) no 200 C +350 C no + 490 - - yes yes 1) no > 350 C +500 C no no no no no no no toxic

75 JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 60.5041 Page 4/5 Connection diagram 1 Dimensions 4 2 1 4 2 110 56 (1) (2) L 45 29 Ø 4,5 d 98 (1) = Ex cable gland, M20x1.5x6-12 (2) = Ex cable gland For other process connections and pockets, see Data Sheet 60.6710 (U, US, UO, Q and V only). Stock items (delivery 3 working days after receipt of order) Sales No. Type Control range C Material of measuring system Capillary mm Probe dia. x length mm 60/60001242 ATH-Ex-2 20+ 50 CrNi 2000 6 x 153 60/60001243 ATH-Ex-2 0+ 50 CrNi 2000 6 x 202 60/60001244 ATH-Ex-2 +40+120 CrNi 2000 6 x 135 60/60001246 ATH-Ex-2 +50+300 CrNi 2000 6 x 67 60/60001247 +40+120 CrNi 2000 6 x 117 60/60001248 +50+300 CrNi 2000 6 x 60

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 60.5041 Page 5/5 Order details ATH-Ex Series Order code (1) Basic type 605041 Surface-mounting thermostat for hazardous areas, ATH-Ex series (2) Basic type extension 02 ATH-Ex-2 Temperature monitor TW 20 Fail-safe temperature monitor STW (3) Control / Limit ranges C 014-20 to +050 021 +00 to+050 025 +00 to+100 056 +40 to +120 062 +50 to +200 080 +80 to +250 064 +50 to +300 045 +20 to +400 046 +20 to +500 (4) Capillary length 1000 1000 mm 2000 2000 mm 3000 3000 mm 4000 4000 mm 5000 5000 mm.... (special length, details in plain text) (5) Material of capillary 40 Cu copper, (only up to +300 C) 20 CrNi stainless steel 1.4571 (6) Process connection (PA) 10 A = plain cylindrical probe (standard) 20 U = screw-in pocket (7) Thread for process connection 00 no thread (process connection A) 13 male thread G 1/2 (8) Material of process connection 00 only for process connection A 46 CuZn (brass) 01 St (steel) 20 CrNi (stainless steel 1.4571) (9) Fitting length S (immersion tube length) 000 ATH-Ex without pocket 100 100mm 120 120mm 150 150mm 200 200mm 300 300mm 400 400mm (10) Diameter D (immersion tube dia.) 00 ATH-Ex without pocket 8 8 mm (11) Diameter d (probe dia.) 6 6 mm Order code (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) 605041 /.. -... -.... -.. -.. -.. -.. -... -.. -. Order example 605041 / 20-062 - 2000-40 - 10-00 - 00-000 - 00-6