Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Similar documents
Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Service & Installation Instructions. An Altra Industrial Motion Company P WE Vented. Enclosed Version Optional

Installation Instructions

Preassembled Clutch/Electrically Released Brake Module

Preassembled Clutch/Brake Module

Preassembled Clutch/Electrically Released Brake Module

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

Electro-Brake 375, 475, 650, 825, 1000, 1225

Warner Electric UNIBRAKE Motor Brakes

TB Series Brakes Tension Control System

Electromagnetic Particle Clutches and Brakes Models: POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 P Performance Manual

Compressor Clutch Replacement Procedure

Electromagnetic Particle Brakes Model: PRB-H

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Electrically Released Brakes FB-375, 475, 650

ERD Electrically Released Brakes

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Electrically Released Brakes FB-375, 475, 650

Electro-Module EM-50, EM-100, EM-180, EM-210, EM-215

AT Clutch Major Service Sizes 25, 55, 115

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

Compressor Clutch Replacement Procedure

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Installation Instructions

MTB II Modular Tension Brakes

Wrap Spring Clutches & Brakes CB & Super CB Series P-2026-WE SM592-gb-02/08

Procedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Safety Sentry Electronic Breakaway Switch

Primary Brakes PB-120, PB-170, PB-250, PB-400

PB-500 Pin Drive, PB-500 Spline Drive PB-650 Pin Drive

Advanced Technology Tension Clutches

Electro-Packs EP-170, 250, 400, 500, 825, 1000, 1525

12-1/4 x 3-1/2 Electric Wheel Brake

SFC-825, SFC-1000, SFC-1225, SFC-1525 Heavy Duty Clutch Coupling and SFC-1525 High Torque Heavy Duty Clutch Coupling

Heavy Duty Industrial Foot Switches

12 Volt Utility Controller for 4, 6, or 8 Brakes No

Installation Instructions

Utility Controller Hand Air Operated

Electromagnetic Toothed Clutch E330

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Pneumatic Single Disc and Dual Disc Brakes P250 and P620

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

Residential, TG-2000 and Commercial MagStop Clutch/Brake

A30 Single Range Tensioncells

Blade Brake Clutch Application Guide P

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

Hydraulic Multi-Disc Brake H420 P-2067-WE SM320gb - rev 02/09

Hydraulic Multidisc Clutch H 110 VAR00 P-2066-WE SM301gb - rev 02/09

Linear Actuators P-6150-WL

Pro-Series/ Electromechanical Linear Actuator

BULLETIN 2212 P Installation Instructions. thru 1027

Special Purpose Overrunning Clutches ep 300 thru 1027 (less Oil Seals)

SF-120, SF-170, SF-250, SF-400 Bearing Mounted, Flange Mounted, SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted

Primary Clutch/Brake Pin Drive, Spline Drive PCB-825, PCB-1000, PCB-1225 Primary Clutch/Brake Coupling PCBC-825, PCBC-1000, PCBC-1225

Size 15 thru 29 Mesur-Fil Fluid Couplings P

Installation Instructions

PVI 60KW, PVI 82KW, PVI 95KW

available today from Warner Electric

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

WR Air Accessory Mounting Brackets

Fan Backstop Clutches Models HFB & VFB

INSTALLATION INSTRUCTIONS

General Purpose Overrunning Clutches

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Garden Tractor Clutch

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

SOLAR DASH CHARGING SYSTEM USER GUIDE

Electrically Released Brakes

6-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

For Dynamic Stopping and Cycling Applications

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

3-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

Size 7.0 Mesur-Fil Fluid Couplings P-1033 WC-96

EM Series Electrically Released Brakes

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

SETRA Operating Instructions Series DPT 230 Pressure Transducers

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

EM Series Electrically Released Brakes

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

CUSTOM CARRIERS. Crane Carrier Company Standard Warranty

Universal Bevel Drives Service Manual

Lint Slide Grid Moist Air Applicator

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Size 9.4 Mesur-Fil Fluid Couplings P WC-97

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

User Guide IGD Series

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Transcription:

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180 P-273-8-WE 819-0531 Installation Instructions Vented Enclosed Version Optional

Warner Electric s MBFB series of Electrically Released Brake Modules are designed for brake only applications when mounted to the back of a NEMA C-face double shaft motor. The fail safe brake engages when power goes off. Model Part No. EM 50-20MBFB-10 5370-169-249 EM 50-20MBFB-10, 24V 5370-169-248 EM 100-20MBFB-21 5370-169-254 EM 100-20MBFB-21,24V 5370-169-253 EM 180-20MBFB-21 5370-169-259 EM 180-20MBFB-21, 24V 5370-169-258 EUM 50-20MBFB-6 5370-169-263 EUM 100-20MBFB-12 5370-169-264 EUM 180-20MBFB-12 5370-169-265 Note: The model EUM is a vented style housing which includes the cover kit to enclose the housing. The model EM is a vented style housing. They can be enclosed by purchasing the optional cover kit 5370-101-082. (See page 4 for details.) Mounting Instructions Step 1: Mounting the Brake to a Motor The brake module (20MBFB) can be mounted directly to the motor as follows: A. Insert the key provided in the motor shaft keyway. Prick punch the end of the motor shaft keyway to prevent the key from sliding out. B. Align the motor shaft and key with the mating shaft hole and key slot in the brake module. If anti-fretting lubricant is used on the motor shaft for future ease of removal, ensure that any excess is wiped off before unit assembly to avoid lubricant contaminating the clutch or brake friction faces. Model Size EUM 50-20MBFB-6 Configuration Static Torque lb. ft. C. Slide the module onto the motor shaft so the module surface is snug against the motor face. NOTE: Brake Module should slide freely onto shaft and fit flush with motor C-face. (Figure 1) Failure to follow these instructions may result in product damage, equipment damage, and serious or fatal injury of personnel. If brake is to be applied with the brake output shaft in a vertical position Warner Electric s application engineering should evaluate application. D. Secure the brake module (20MBFB) to the motor C-face with the four (4) long hex head capscrews provided. Tighten the four (4) bolts alternately to ensure even alignment of the module. Tighten them to 30-35 foot pounds. The term fail safe describes a brake that engages automatically when its full power is shut off for whatever reason. The term, as applied to brakes, designates a mode of operation, not a guarantee of safety for the equipment on which the brake is mounted and for personnel who are near it. Figure 1 2 Warner Electric 800-825-9050 P-273-8-WE 819-0531

Step 2: Electrical Connections The conduit hole in the motor brake is threaded for standard pipe conduit connectors. The wiring diagram included with each Warner Electric control shows the proper electrical connections to be made. Note: Controls used must have adjustable output voltage. Connect the red wire from the unit to the + terminal of the DC supply and the black wire from the unit to the - terminal of the DC supply. Note: Refer to the brake release adjustment procedure on page 4. Control Requirements All Permanent Magnet Type Electrically Released Brake Modules are polarity sensitive. Therefore, the red + wire must be connected to the + terminal and the black - wire to the - terminal. Potentiometer control will then provide adjustment for the proper brake release point as described in the brake release procedure on page 4. See the service installation instruction provided with control for connection information. 90 Volt Brake recommended controls are: *CBC-160-1 *CBC-160-2 CBC-300 CBC-500-90 CBC-550-90 120 VAC input part no. 6013-448-001 220-240 VAC input part no. 6013-448-002 120 VAC input part no. 6021-448-001 120 VAC input part no. 6024-448-003 120/220/240/380/480 VAC input part no. 6024-448-006 *These controls are for use with conduit box kit part no. 5370-101-042. All others require other enclosures or alternate mounting. 24 Volt Brake recommended controls are: CBC-500-24 CBC-550-24 24-30 VAC input part no. 6024-448-002 120/220/240/380/480 VAC input part no. 6024-448-005 All Permanent Magnet type Electrically Released Brake Modules are polarity sensitive. See the service installation sheet included with the control for connection information. Burnishing and Maintenance No burnishing required, units are pre-burnished and armature airgap set at the factory. As with any friction-type device, some initial concern should be given to wear rate. Improper voltage setting can reduce the braking life. Once the best release voltage has been established, precautions should be taken to prevent machine operators, or other personnel not familiar with wear characteristics, from changing the potentiometer setting arbitrarily. Wear Pattern Wear grooves appear on the friction surfaces. This is a normal wear condition, and does not impair functioning of the unit. Never machine the friction surfaces to remove grooves or score marks resulting from normal wear. Foreign Materials If units are used on machinery where fine, abrasive dust, chips or grit are dispelled into the atmosphere, or if the wear particles from the brake are undesirable, you may use the optional cover kit to enclose the module. See page 4 for more information. Where units are used near gear boxes or transmissions requiring frequent lubrication, means should be provided to protect the friction surfaces from oil and grease to prevent serious loss of torque. Warner Electric 800-825-9050 P-273-8-WE 819-0531 3

Brake Release Adjustment Instructions for setting the optimum release voltage of permanent magnet applied/electrically released brakes. The following procedure will result in the brake releasing and allowing the load to be free to move. Be sure the load is in a safe condition before proceeding with this process. In a permanent magnet applied/electrically released brake, the attractive force between the brake surfaces is created by permanent magnets. The brake is electrically released by applying DC power to the electro-magnetic coil in the brake that opposes the permanent magnets. Electrically released brakes are polarity sensitive: The positive lead of the power supply must be connected to the positive (red) lead of the brake and the negative lead of the power supply must be connected to the negative (black) lead of the brake. The power supply applied to the brake must also be adjustable so that the optimum release voltage for each individual brake can be determined and set. The following procedure describes how to set the adjustable power supply to the optimum release point of the brake. A volt-meter is required to perform the procedure. No power is applied to motor during this procedure. Power normally supplied by motor to brake control should be supplied by alternate method. 1. With power off, connect the positive lead of the power supply to the positive (red) lead of the brake and the negative lead of the power supply to the negative lead (black) of the brake. 2. Connect a volt-meter to measure the voltage applied across the brake. 3. Adjust the power supply to its lowest possible output, and then energize the power supply to apply power to the brake. 4. Starting from the low voltage point, slowly increase the applied voltage while visually watching the brake armature through the vents on either side of the module and through the ½ by 1 inch window in the clutch rotor fan until the brake armature disengages from the brake magnet. Note and record this voltage reading. 5. Add twenty (20) volts for a 90 volt brake and five (5) volts for a 24 volt brake to this reading and set the supply to this level. This will be the proper release voltage for your setup. 6. With the brake energized, spin the motor shaft by hand to insure that it turns freely. If a scraping sound is noted when the output shaft is spun, it means an armature is dragging slightly. Correct this problem by repeating steps 1 through 5 above. If any problems should occur during adjustments or application questions arise, please contact Technical Support at 1-800-825-9050 Monday through Friday 7:30 a.m. - 4:30 p.m. central time. 4 Warner Electric 800-825-9050 P-273-8-WE 819-0531

Enclosed EM-20MBFB Module Option Scan to Watch Cover Kits Video https://p.widencdn.net/xrhdfr If an Enclosed Brake-Module is required, an optional Cover Kit, Warner Electric part number 5370-101- 082, can be purchased separately to enclose the open vents in the housing and a cover plate to close off the back of the Module. Each Cover Kit includes two (2) vent covers, four (4) screws and one (1) cover plate needed to convert a vented EM-20MBFB to an enclosed design (non-washdown) as shown in Figure 2. Notes: Visit Warner Electric s website at www.warnerelectric. com for dimensional drawings, weights, inertias, and a complete offering of our products including clutches, brakes and clutch/brake controls and service parts. In addition to Warner Electric module products, other package products, controls, and service parts information can be found in our Packaged Electromagnetic Clutches/Brakes Catalog Series: NEMA C-Face Compatible Clutches, Brakes & Clutch Brake Combinations Catalog P-8586-WE Shaft Mounted Clutches & Brakes Catalog P-8587 WE Base Mounted Clutch/Brake Combinations Catalog P-8588-WE Electrically Released Spring-Set Brakes & Unibrake AC Motor Brakes Catalog P-8589-WE Permanent Magnet Electrically Released Brakes Catalog P-8590-WE. Call 815-389-3771 to request any of our catalogs. Figure 2 Note: When using this cover kit to enclose the module the vent covers should be assembled as the final step. Warner Electric 800-825-9050 P-273-8-WE 819-0531 5

Warranty Warner Electric LLC warrants that it will repair or replace (whichever it deems advisable) any product manufactured and sold by it which proves to be defective in material or workmanship within a period of one (1) year from the date of original purchase for consumer, commercial or industrial use. This warranty extends only to the original purchaser and is not transferable or assignable without Warner Electric LLC s prior consent. Warranty service can be obtained in the U.S.A. by returning any defective product, transportation charges prepaid, to the appropriate Warner Electric LLC factory. Additional warranty information may be obtained by writing the Customer Satisfaction Department, Warner Electric LLC, 449 Gardner Street, South Beloit, Illinois 61080, or by calling 815-389-3771. A purchase receipt or other proof of original purchase will be required before warranty service is rendered. If found defective under the terms of this warranty, repair or replacement will be made, without charge, together with a refund for transportation costs. If found not to be defective, you will be notified and, with your consent, the item will be repaired or replaced and returned to you at your expense. This warranty covers normal use and does not cover damage or defect which results from alteration, accident, neglect, or improper installation, operation, or maintenance. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. Warner Electric LLC s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential, indirect, or incidental damages of any kind incurred by reason of the manufacture, sale or use of any defective product. Warner Electric LLC neither assumes nor authorizes any other person to give any other warranty or to assume any other obligation or liability on its behalf. WITH RESPECT TO CONSUMER USE OF THE PRODUCT, ANY IMPLIED WARRANTIES WHICH THE CONSUMER MAY HAVE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. WITH RESPECT TO COMMERCIAL AND INDUSTRIAL USES OF THE PRODUCT, THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Changes in Dimensions and Specifications All dimensions and specifications shown in Warner Electric catalogs are subject to change without notice. Weights do not include weight of boxing for shipment. Certified prints will be furnished without charge on request to Warner Electric. www.warnerelectric.com 31 Industrial Park Road New Hartford, CT 06057 815-389-3771 P-273-8-WE 819-0531 12/18