Type List Terminal style WP (High power type, terminals)-.0mm pitch Contact form A (SPNO) Features Low Profile mm w/ fasten terminals. High Rating 7A 277VAC. High temperature withstand up to 2. UL/CUL VDE approvals. High CTI 20 material or product comply with IEC 6033- are available. Complies with RoHS-Directive 20/6/EU. UL Insulation Designation (provided with) system approval Sealed type Flux tight Sealed type washable F -AC-F-C -AC-F-V -AC-F-S WP2 (High power type, terminals)- 7.mm pitch WP3 (High power type, terminals)-.0mm pitch WP4 (High power type, terminals)- 7.mm pitch A (SPNO) F 2-AC-F-C 2-AC-F-V 2-AC-F-S A (SPNO) F 3-AC-F-C 3-AC-F-V 3-AC-F-S A (SPNO) F 4-AC-F-C 4-AC-F-V 4-AC-F-S Ordering Information 88 WP - A C - - C 2 3 4 6 7 8. 88 -- Basic series designation 4. C -- Contact material AgNi 2. WP -- High power type w/quick connect & PCB terminals -.0mm pitch WP2 -- High power type w/quick connect & PCB terminals - 7.mm pitch WP3 -- High power type w/horizontal quick connect & PCB terminals -.0mm pitch WP4 -- High Power type w/horizontal quick connect & PCB terminals - 7.mm pitch. Blank -- Standard type F -- Class F 6. C -- Flux tight V -- Sealed type S -- Sealed type washable 7. Blank -- Standard type 3. A -- Single pole normally open B -- Single pole normally closed 8. -- Coil voltage (please refer to the coil rating data for the availability) 86
Contact Rating Rated load (resistive) 6A 240VAC, at 0 C, 7K ops. ; A 240VAC, at 0 C, typ. 300K ops. Max. switching current 7A Max. switching voltage 277VAC Max. switching capacity 3840VA Coil Rating (DC) Rated Rated current Coil resistance Max. continuous Pick up Drop out Power consumption voltage 0 % at 23 C at 23 C voltage voltage(max.) voltage(min.) at rated (V) (ma) ( ) at 0 C at 23 C at 23 C voltage 80 62 0% 6 67 90 0% 9 44 203 0% 2 33 360 0% 0 % of 70 % of 0 % of 8 23 77 0% rated rated rated approx. 0.4W 24 7 440 0% voltage voltage voltage 36. 3240 0% 48 8.7 20 0% 60 8 7340 % Specification Contact material Contact resistance () AgNi alloy 00m Max. (at A/ 6VDC by 4-wire resistance measurement) Operate time () 20ms Max. Release time () 0ms Max. Operating extremes 0 Hz, amplitude. mm Vibration resistance Damage limits 0 Hz, amplitude. mm Operating extremes 0G Shock resistance Damage limits 00G Mechanical 0,000,000 ops. (frequency 72,000 ops./hr) Life expectancy Electrical 00,000 ops. (frequency 360 ops./hr) Operating ambient temperature -40 +0 C (no freezing) (2) Weight Approx. 3 g Note () Initial value. Operate and release time excluding contact bounce. (2) Special version of high temperature 2 C can be selected. (3) Unless otherwise specified, all tests are under room temperature and humidity. (4) Consider the heat of PCB is necessary, please check the actual condition of PCB. () Applying no diode to this relay. The life expectancy will be lower when a diode is used. To use a varistor (ZNR) could absorb the coil surge of relay that is recommended. 87
(6) Do not use the relay exceeding the coil rating, contact rating and life expectancy, or this may cause the risk of overheating. (7) To assure optimum performance, avoid the relay from dropping, hitting, or other unnecessary shocks. (8) Do not switch the contacts without any load as the contact resistance may become increased rapidly. (9) Use suitable harnesses and bus bars according to the current as below A type Min. 3.0 mm 6A type Min. 3.0 mm 2 2 (0) Usage, transport and storage conditions. Temperature: -40 +0 C 2. Humidity: to 8% R.H. 3. Pressure: 86 to 06 kpa Furthermore, the humidity range varies with the temperature. So, use relays within the range indicated in the graph below. Humidity, %RH Tolerance range (Avoid freezing when used at temperatures lower than 0 C) (Avoid condensation when used at temperatures higher than 0 C ) Temperature, C () Please contact Song Chuan for the detailed information. Insulation Data Insulation resistance () 000M Min. (DC 00V) Surge voltage withstand () Between contact and coil : 0KV (.2X0) S Between open contact : AC 000V, 0/60Hz min. Dielectric strength () Between contact and coil : AC 000V, 0/60Hz min. Insulation of IEC 680- Clearance / creepage distances Between coil to contact Between open contact Rated insulation voltage 20V Rated impulse withstand voltage 4000V Pollution degree 3 : Reinforce, 6.0mm / 8.0mm : Functional Rated voltage Overvoltage category Note () Initial value. 230 / 400V II Safety Approval Certified UL / CUL VDE File No. E8899 3290 88
Safety Approval Rating UL / CUL 7A 277VAC 0A 400VAC VDE 2A 20VAC T2 0A 400VAC T2 7A 20VAC T0 Outline Dimensions () (0.97) (0.03) (.20) (0.00) 0. (0.06) 32. (.280) (0.97) 2 () 7. (0.29) (0.03) (.20) (0.00) 0. (0.06) 32. (.280) (0.97) 89
3 4.2 (0.9) () (0.97) (0.03) (.20) 4 Wiring Diagram BOTTOM VIEW PC Board Layout BOTTOM VIEW 2.4-4 (0.0).4-4 7. (0.29) (0.00) 0. (0.06) 32. (.280) (0.97) 4.2 (0.9) () 7. (0.29) (0.03) (.20) (0.00) 0. (0.06) 32. (.280) (0.97) TOLERANCE: LESS THAN: ±0.(0.004) (0.97) ± 20(0.787) ±0. MORE THAN: 20(0.787) ± A B (0.0).3-2 (0.0) 32. (.280) (0.97) (0.97).3-2 (0.0) 32. (.280) (0.97) 90
3 4.4-4 (0.0).4-4 (0.0).3-2 (0.0) 32. (.280) (0.97) (0.97).3-2 (0.0) 32. (.280) (0.97) 7. (0.29) Engineering Data 00 Coil temperature rise 0 Coil temperature rise 90 Temperature rise ( ) 80 70 60 0 40 30 20 6A Temperature rise ( ) 4 40 3 30 6A 0 60 80 00 20 40 60 80 2 8 90 9 00 0 0 % of Nominal Coil Voltage (at 23 ) % of Nominal Coil Voltage (at 0 ) Number of operations Life expectancy 0 7 6 0 0 240VAC 0 4 0 8 0 2 4 6 8 % of Nominal coil voltage (at 23 ) AC resistive load/switching current(a) Time (ms) Operate time/release time 4 3 Operate time 2 0 9 avg max 8 7 6 min 4 3 2 Release time max 0 min 70 80 90 00 0 avg 20 All specifications subject to change. Please contact Song Chuan for update. 9