Pneumatic Actuators. TGA Specifications

Similar documents
TG-S Specifications TG-12S Rc3/8. 6 to 20

Pneumatic Cylinder. 3I Double-acting type. 3Q Single-acting type (spring returned type)

KTM Pneumatic Actuators AW, AWN series (for large sized valves)

KTM PNEUMATIC ACTUATORS AW, AWN SERIES (FOR LARGE SIZED VALVES)

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

ELECTRONIC CONTROL ACTUATOR

ACTUATORS GENERAL CATALOG

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance.

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

KTM PNEUMATIC ACTUATORS AK SERIES (FOR SMALL AND MIDDLE SIZED VALVES)

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Operation Manual For KITZ B Series Pneumatic Valve Actuators

Smart Valve Positioner 700 Series with HART Communication Protocol

Pressure Control Equipment

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

Smart Positioner YT-2400L,R Installation manual

Pneumatic-Pneumatic Positioner YT-1200L,R Installation manual

Air-oil Systems. Air-oil Systems

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

Compact Proportional Solenoid Valve

Smart Valve Positioner 700 Series with HART Communication Protocol

Smart Valve Positioner 200 Series

Lateral parallel hand Double acting. Operational stroke length: 20, 30, 40mm. 980m/s2

Fig Single-Acting Rotary Smart Positioner

MAQ Series Electric Actuator

PRODUCTS CATALOG (2018) TISSIN CO.,LTD. Smart Valve Positioner. Electro-Pneumatic Positioner. Volume Booster. Lock Up Valve. Air Filter Regulator

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

HFP Series. Specifications. Switch specifications. Wide parallel hand Double acting. Operational stroke length: 20, 30, 40, 60mm.

! Contact our sales office regarding a delivery date or a price since this is a special model. Auto switch D-M9 series mountable

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

PERFORMANCE IP67 (IEC60529, JIS C 0920) Silver contact: Max.50 mω (6 to 8 Vdc, energizing current 1A, measured by voltage drop method) Gold alloy cros

SMART POSITIONER YT-2400 SERIES USER'S MANUAL

User s Manual. Pneumatic Positioner. Series 58. J Flow. Series 58. J Flow

AIR MOTOR MASTER VALVE FULL OPEN POSITION SENSOR SWITCH. Overall Block Diagram (Local Control Type)

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

PNEUMATIC ON OFF GLOBE VALVE

Automation is the techniques and equipment used to achieve automatic operation or control.

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Control Valves Positioner

Control Valves Positioner

POSITIONERS and Controls for Complete Valve Automation

Actuated Valves. Product Information

Smart Valve Positioner for Rotary Valve

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

KTM PNEUMATIC ACTUATORS AK SERIES (FOR SMALL AND MIDDLE SIZED VALVES)

MULTISTAGE MICRO EJECTORS

Smart Valve explorer Smart Valve Positioner for Rotary Valve. Model SVX100 / SVX102

CENTAC Inlet and Bypass Valve Positioners

SMART POSITIONER YT-2300 SERIES USER'S MANUAL

ROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

Data Sheet. I/P and E/P converters. RS stock numbers ,

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

OM Field-Type I/P Converter Model : KUX113 User's Manual

EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure

YT-1200 Series VERSION 1.02

Series AV2000/3000/4000/5000

Models UP1/2/3/4/5/6/7 Universal pneumatic rotary actuators. Measurement made easy. High performance actuators for precision damper control

EX Series. Electric Actuators for Ball and Butterfly Valves

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

Spring Cylinder Rotary Actuator

TopControl Continuous


Pneumatic Positioner PNY Series USER'S MANUAL. Max-Air Technology. Version 1.0

PNEUMATIC POWER CYLINDER

4.3 MSK SWITCH BOX MSK (SIZE I) FEATURES ADVANTAGES

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

SINGLE-ACTING ACTUATORS FOR DOUBLE-ACTING & SERIES 65 POSITIONERS PNEUMATIC & ELECTRO-PNEUMATIC. The High Performance Company

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Quarter turn actuators Index

Rotary Damper Pneumatic Actuated Type TA

Discharge oil capacity cm Discharge oil capacity. Max. stroke volume on retraction Remarks.

Actuators & Positioners Models UP1/2/3/4/5/6/7. Universal Pneumatic Rotary Actuators

Butterfly Valves Pneumatic Actuated Type TA Type TW

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)

PP Series Pneumatic Actuators

How to Select Automation Accessories for Valves

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Recommended spare parts and often used accessories

PNEUMATIC ACTUATORS. Linear acting

BUTTERFLY VALVE POWER-PACK CONTROLLED BUTTERFLY VALVE

Performance. Type NA006 NA009 NA015 NA019 NA028 NA038 NA050 NA060 NA080 NA100 NA150 NA200 NA250

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

SOLENOID VALVES 300 SERIES INSTRUCTION MANUAL

Operating Instructions. Angle Seat Control Valve. Type 7020

Linear slide cylinder Double acting single rod type. Bore size: 4.5, 6, 8. Descriptions Bore size mm

ELECTRONIC CONTROL ACTUATOR

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

Transcription:

Pneumatic Actuators The TGA model is a double-action pneumatic actuator perfect for on/off control of the various types of butterfly valves. With an optional positioner, it can also be used for flow rate control. It mainly used for the medium to large-sized valves of size 350mm or more. The operation principle is that air pressure forces the piston inside the cylinder into a linear reciprocating motion, causing the trunnion coupled to the rod to drive the arm and rotate the output shaft. TGA Specifications Output torque (Nm) (When supply pressure is 0. MPa and rotation angle is 0or 90) TGA-5 70 TGA-0 860 TGA-60 750 TGA-80 3800 TGA-0 5300 TGA- 70 TGA-50 00 Supply pressure (MPa) 0. to 0.7 Body shell max (MPa).0 Rotating angle to 90 Port size Rc3/8 Rc/ Operating fluid Dry air Ambient temperature / supply air temperature 0 to 80C / 0 to 60C (Non-freezing) Rotating speed range (sec.) 5 to 5 Coating Epoxy primer finish (Munsell N7) TGA-0

TGA Outer Dimensions PApprox. AApprox. PApprox. VIEW"E" n-m tap, depth N C F f Approx. fapprox. B Air connection port -G H d H b a a TGA Dimensions TGA-5 TGA-0 TGA-60 TGA-80 TGA-0 TGA- TGA-50 73 80 939 053 63 8 38 38 7 83 53 599 6 707 36 393 56 50 56 606 67 6 80 8 53 70 99 00 00 30 30 60 60 60 6 70 80 90 00 0 5 3 8 30 33 370 00 33 Dimension (mm) A P P f f B H H d b a a F C n M N G 5 60 6 65 70 85 00 0 5 60 65 75 75 75 5 8 0 55 55 60 65 80 95 0 0 60 60 3 3 3 70 70 80 80 80 8 8 8 M6 M6 M M M M M 5 5 5 5 5 Rc3/8 Rc3/8 Rc3/8 Rc3/8 Rc/ Rc/ Rc/ Approx. Mass kg 3 5 9 7 98 6 TGA-0

TGA Operation principle As chambers A - A and B - B are connected through copper tubes as shown in the figure at left (single-acting cylinder is provided only with chambers A and B), feeding air into port S will generate a thrust to push the piston toward the left. The linear motion of the piston is converted to a clockwise rotary motion of the output shaft through the trunnion. Residual air in chamber B is exhausted through port O. Feeding air to port O causes the reverse of the action described above, rotating the output shaft counter-clockwise. Port O B Piston A Output shaft Port S B A Arm Piston rod Trunnion TGA Air consumption Cylinder capacity (R) A OS B SO TGA-5 3.69 3.69 TGA-0 5.3 5.3 A B TGA-60 7.73 7.73 B A TGA-80 0.87 0.87 TGA-0 TGA-.730.9.730.9 A=A+A B=B+B TGA-50 9.78 9.78 () Required air consumption Double-acting type VD=(A+B) Single-acting type VS=(A or B) () Air consumption within a unit time Double-acting type Single-acting type P-0.03 0.03 P+0.03 0.03 CD= CS= N N VD t VS t VD : Double-acting type cylinder air consumption (N ) VS : Single-acting type cylinder air consumption (N ) A, B : Cylinder capacity ( ) P : Working pressure (Mpa) N : Operating frequencies in a given time ( round trip=) C D : Double-acting type cylinder air consumption (N /sec) C S : Single-acting type cylinder air consumption (N /sec) t : Unit time (sec) Remark: The compressor should have a larger capacity than the air consumption calculated above in () and (). TGA-03

TGA Output torque curve Double-acting type (TGA) 000 Supply pressure 0. MPa 0000 Torque Nm 5000 000 3000 00 000 500 TGA-50 TGA- TGA-0 TGA-80 TGA-60 TGA-0 TGA-5 0 0 0 30 0 50 60 70 80 90 Rotation angle. The table shows the torque at an operating air pressure of 0.MPa.. Output torque for an operating air pressure of PMPa is given by: P=P/ X torque value obtained from the table. TGA Output torque TGA-5 TGA-0 TGA-60 TGA-80 TGA-0 TGA- TGA-50 0. 0.5 0.6 0.7 70 860 750 3800 5300 70 00 588 35 338 750 665 9000 5000 905 790 5 5700 7950 0800 8000 3 355 83 6650 975 600 000 TGA-0

TGA Expanded view of component TGA-5 to 60 9 3 7 6 8 30 TGA-5,0 7 8 5 6 9 33 30 3 3 7 35 3 3 5 8 3 5 6 9 6 36 5 9 8 3 8 7 3 35 7 TGA-05

TGA-5 to 60 parts list (double-acting type) TGA Parts list No. Description Q ty Remarks 3 5 6 7 8 9 3 5 6 7 8 9 3 5 6 7 8 9 30 3 33 3 35 36 5 Body End cover Piston Rod cover Arm Piston rod Case Trunnion Shaft Rings Tie rod Bush Bush V-ring Cover Seal washer Hexagon bolt Spring washer Hexagon nut Lock nut Screws Gasket C-retainer Stopper bolt Spring pin Copper pipe Pipe coupler Indicator C-retainer Set of 8 8 Remark: Parts with a star before the part number are recommended replacement parts. To order as a set, please specify set. TGA-06

TGA Expanded view of component TGA-80 to 50 6 8 3 9 8 7 7 3 3 35 3 7 5 30 8 30 3 3 5 37 6 6 38 6 39 9 7 9 8 3 35 3 36 5 7 8 TGA-07

TGA-80 to 50 parts list (double-acting type) 3 5 6 7 8 9 3 5 7 8 9 3 6 7 8 30 3 3 3 35 36 37 38 39 5 6 Body End cover Piston Rod cover Arm Piston rod Case Trunnion Shaft Rings Tie rod Bush Bush Bush Hexagon bolt Lock nut Screws C-retainer C-retainer Stopper bolt Copper pipe Pipe coupler Indicator Bush Oil seal Key C-retainer Stop ring Set of 8 8 Set of TGA Parts list No. Description Q ty Remarks Remark: Parts with a star before the part number are recommended replacement parts. To order as a set, please specify set. TGA-08

TGA Accessories Double-acting type Accessory Manufacturer Part No. TGA-5 TGA-0 TGA-60 TGA-80 TGA-0 TGA- TGA-50 Five-port/-position, non explosion-proof, solenoid valve Five-port/-position, explosion-proof, solenoid valve Filter regulator Limit switch Proximity switch Positioner Manual operating Stroke adjuster Speed controller Solencer Lock-up valve Quick exhaust valve Booster relay Single solenoid Double solenoid Single solenoid Double solenoid Non explosion-proof Explosion-proof M8 shielded M8 non-shielded M30 shielded Electro-pneumatic Pneumatic-pneumatic Manual gear unit Kuroda Kuroda Kuroda Kuroda Kaneko Kaneko Tomoe Yamatake OMRON Yamatake Yamatake OMRON OMRON OMRON SSS Yamatake Tomoe Tomoe PCS08-MC PCS5-MC PCD08-MC PCD5-MC MB5G-TMS MB5DG-TMS AW30-03B-X90 AW0-0B- TMS-BOX LS-J WLCA LX500 VCX-5003 EE-X7D-N EE-XMD EE-X0D-N TCE00 TP800 AVP300 IP500 MGC AS3000-03 AS000-0 AN0-0 AN300-03 AN00-0 IL-0 AQ3000-03 AQ5000-0 IL00-03 Remarks:. Symbols in table mean the following: : Standard accessory, : Installable, : Un-installable. This table shows typical accessory combinations. Accessories not shown in this table can also be installed. For details, please consult us. TGA-09

TGA Solenoid valves Purpose The purpose of a solenoid valve is to use electrical signals to remotely change the air flow to operate the valves. Standard specifications Item Five-port/-position, non explosion-proof, solenoid valve (single solenoid) Five-port/-position, non explosion-proof, solenoid valve (single solenoid) Five-port/-position, explosion-proof, solenoid valve (single solenoid) PCS08-MC PCS5-MC MB5G-0AEPU-TMS Manufacturer Kuroda Kuroda Kaneko JIS symbol R P R B A R P R B A R IN R Applicable cylinder type TGA-5 to 80 Rc3/8 (IN, OUT) Air connection port size Rc/ (EXH) Effective sectional area 30mm AC00V/0V 50/60Hz Rated voltage AC0V/V 50/60Hz DCV Explosion-proof construction Wiring method Conduit terminal Conduit entry G/ Manual operating Non lock bush type Operating temperature 5 to 50 degrees C Weight 0.6kg TGA-0 to 50 Rc/ (IN, OUT) Rc3/8 (EXH) 70mm AC00V/0V 50/60Hz AC0V/V 50/60Hz DCV Conduit terminal G/ Non lock bush type 5 to 50 degrees C 0.85kg TGA-5 to 50 Rc3/8 (IN, OUT) Rc/ (EXH) mm AC00V, AC0V 50/60Hz AC0V, ACV 60Hz DCV dg Conduit terminal G/ Manual botton lock type to 60 degrees C.kg Remark: The above are standard TOMOE-compatible solenoid valves. It is also possible to install solenoid valves other that those listed above such as a double solenoid or 3-port solenoid valve. For details, please consult us. MB5G-0AEPU-TMS PCS08-MC PCS5-MC TGA-0

TGA Filter regulator (Pressure reducer with filter) Purpose Filter regulators are used to eliminate oil, water, and dust from the operating air in order to protect pneumatic accessories (solenoid valve and cylinder, etc.) and to keep operating pressure at an adequate and constant level (about to 5 K). Standard specifications Manufacturer AW30-03B-X90 AW0-0B- JIS symbol Applicable cylinder type Set pressure range Pressure gauge connection port Operating temperature Air connection port size Filtration TGA-5 to 80 0.05 to.85mpa Rc/8 5 to 60 degrees C Rc3/8 5m TGA-0 to 50 0.05 to 0.85MPa Rc/ 5 to 60 degrees C Rc/ 5m Option Auto drain for low and high temperatures Auto drain for low and high temperatures Weight 0.79kg.5kg Remark: The above are standard TOMOE-compatible filter regulators. It is also possible to install filter regulators other that those listed above. For details, please consult us. AW30-03B-X90 AW0-0B- TGA-

TGA Limit switches Purpose Limit switches are used to convert the valve position (full close, full open, half open) into electric signals for lamp indication at a remote location. Standard specifications Manufacturer TMS-BOX Monopolar double-throwc, SPDTX LS-J WLCA YamatakeLS-J OMRONWLCA Bipolar double interruptionab, DPDT LX500 Yamatake Bipolar double interruptionab, DPDT VCX-5003 Yamatake Monopolar double-throwc, SPDTX Circuit NC (NO) (NO) 3 (NO) (NO) 3 NC COM NO (NC) (NC) (NC) (NC) COM NO Actuator Class of insulation Rated voltage Operating temperature Conduit entry Option Contacts Weight Hinge roller lever type IP67Option ExdBT6 AC50V-6A DCV-0.6A 0 to 80 degrees C -G/ Switch detection with one ( switches inside) 0.98kg Roller lever type IP67 AC5V-0A AC50V-0A AC80V-0A DC5V-0.8A DC50V-0.A 0 to 80 degrees C G/ Heat, cold and corrosion resistant On or off detection with one Two for both on and off detection 0.8kg Roller lever type IP67, dg AC5V-5A AC50V-5A DC5V-0.8A DC50V-0.A 0 to 70 degrees C G/ Hydrogen anti-explosion (LX570) On or off detection with one Two for both on and off detection 0.7kg Adjustable roller lever type IP67, dg AC50V-5A DC5V-0.8A DC50V-0.A 0 to 70 degrees C G3/ Waterproof (VCL-5003) Switch detection with one ( switches inside) 0.77kg Remark: The above are standard TOMOE-compatible limit switches. It is also possible to install limit switches other that those listed above. For details, please consult us. TMS-BOX VCX-5003 LX500 LS-J WLCA TGA-

TGA Proximity switches Purpose Proximity switches are used to convert the valve position (full close, full open, half open) into electric signals for lamp indication at a remote location. Standard specifications Product Manufacturer With power source Motion mode Detecting distance Object to be detected Power source voltage Current consumption Class of insulation Operating temperature Connection M8 shielded type (Can be embedded in metal.) EE-X7D-N OMRON DC -wire system NO 0 to 5.6mm Magnetic metal (stainless steel possible) DC to V 3 to 00mA IP67 5 to 70 degrees C Cord draw type (m) M8 non-shielded type (Cannot be embedded in metal.) EE-XMD OMRON DC -wire system NO 0 to.mm Magnetic metal (stainless steel possible) DC to V 3 to 00mA IP67 5 to 70 degrees C Cord draw type (m) M30 shielded type (Can be embedded in metal.) EE-X0D-N OMRON DC -wire system NO 0 to 8mm Magnetic metal (stainless steel possible) DC to V 3 to 00mA IP67 5 to 70 degrees C Cord draw type (m) Contacts Weight On or off detection with one Two for both on and off detection 0.3kg On or off detection with one Two for both on and off detection 0.3kg On or off detection with one Two for both on and off detection 0.8kg Remark: The above are standard TOMOE-compatible proximity switches. It is also possible to install limit switches other that those listed above such as a DC 3-wire, AC -wire, AC/DC -wire or connector-type proximity switch. For details, please consult us. M8 M8 M30 TGA-3

TGA Positioners Purpose A positioners are used for quick and accurate control of the valve opening angle with pneumatic signals or -ma DC input signals from a control room or controller unit. Standard specifications Manufacturer Input signal Resistance Supply air Output flow rate Air consumption Electro-Pneumatic, analog TCE00 Tomoe to ma 50 ( to madc) 0. to 0.7MPa 80L/min. or more (SUP=0.MPa) Within L/min. (SUP=0.MPa) Electro-Pneumatic, analog TP800 Tomoe to ma 355 ( to madc) 0. to 0.7MPa 0L/min. or more (SUP=0.MPa) Within L/min. (SUP=0.MPa) Electro-Pneumatic, digital (smart) AVP300 Yamatake to ma 300 ( to madc) 0. to 0.7MPa 50L/min. or more (SUP=0.MPa) Within 0L/min. (SUP=0.MPa) Pneumatic-Pneumatic IP500 0.0 to 0.MPa 0. to 0.7MPa 0L/min. or more (SUP=0.MPa) Within L/min. (SUP=0.MPa) to 83 degrees C (Non explosion-proof) to 8 degrees C (Non explosion-proof) 0 to 80 degrees C (Non explosion-proof) Operating temperature to 60 degrees C (Explosion-proof type dg) to 60 degrees C (Explosion-proof type dg) to 60 degrees C (Explosion-proof type dg) to 80 degrees C Class of insulation IP65, ExdBT6X IP67, ExdBT5 IP65 (option: ExdCT6X) Air connection port size Rc/ Rc/ Rc/ Rc/ Conduit entry Sensitivity Repeatability Hysterisis Option Weight -G/ Within 0.5%FS Within.5%FS Within %FS.3kg -G/ Within 0.5%FS Within %FS Within %FS.6kg -G/ Within %FS Within %FS Within %FS Analog signal ( to ma) output Any special opening setting Supports field bus..8kg Within 0.5%FS Within %FS Within %FS.kg Remark: The above are standard TOMOE-compatible positioners. It is also possible to install positioners other that those listed above. For details, please consult us. TP800 TCE00 AVP300 IP500 TGA-

TGA Manual operation unit Purpose The operation unit is for manual operation of the pneumatic cylinder when air supply fails. Standard specifications Function Applicable cylinder Remarks Manual gear unit Worm gear (D) Double acting type T-matic (E) Double acting type over TGA-00 (F) Single acting type () Be sure to open the bypass valve. () Attach and detach the clutch exactly before and after operation. TGA-5

TGA Stroke adjuster Purpose The stroke adjuster sets the valve opening freely from the outside. Standard specifications Function Free opening unit Adjust screw Side adjust screw Side adjust screw Applicable cylinder (A) Double acting type T-matic (B) Double acting type TGA-00 (C) Single acting type T-matic Remarks After attaching a long adjustment bolt to the cylinder cover, attach the cover of the aluminium casing. Attach long adjusting screws and lock nut to the cylinder cover. TGA Speed controllers Purpose For double-acting cylinders, the speed controller is used as meter out (exhaust throttle) and for single-acting cylinders, it is used as meter in (suction throttle). Standard specifications Manufacturer AS3000-03 AS000-0 JIS symbol Applicable cylinder type Needle revolution Adjustable range Operating temperature Air connection port size Attachement Weight TGA-5 to 80 8 rotations. 5 to 5 secs 5 to 60 degrees C Rc3/8 Install to cylinder air connect port 0.3kg TGA-0 to 50 8 rotations. 5 to 5 secs 5 to 60 degrees C Rc/ Install to cylinder air connect port 0.kg Remark: The above are standard TOMOE-compatible speed controllers. It is also possible to install speed controllers other that those listed above. For details, please consult us. TGA-6

TGA Silencers Purpose Silencers eliminate noise at the exhaust ports on various kinds of pneumatic accessories. Standard specifications AN0-0 Manufacturer JIS symbol Effect of muffing 30dB (A) Operating temperature Port size Attachement Weight 5 to 60 degrees C Rc/ Screw into exhaust port of solenoid valve. 0.0kg AN300-03 30dB (A) 5 to 60 degrees C Rc3/8 Screw into exhaust port of solenoid valve. 0.03kg AN00-0 30dB (A) 5 to 60 degrees C Rc/ Screw into exhaust port of solenoid valve. 0.0kg Remark: The above are standard TOMOE-compatible silencers. It is also possible to install silencers other that those listed above. For details, please consult us. TGA Lock-up valves Purpose When air supply fails, the lock-up valve automatically stops the line until pressure is restored and keeps the operating unit of the cylinder at the stay-put position. Standard specifications Manufacturer JIS symbol Effective sectional area Operating temperature Air connection port size Signal pressure connection port Weight IL-0 7mm 5 to 60 degrees C Rc/ Rc/ 0.6kg Remark: The above are standard TOMOE-compatible lock-up valves. It is also possible to install lock-up valves other that those listed above. For details, please consult us. TGA-7

TGA Quick exhaust valve Purpose Quick exhaust valves act in the reverse way to a speed controller. The valve shortens the open/close operation time by improving the exhaust efficiency of the cylinder. Standard specifications Manufacturer AQ3000-03 AQ5000-0 JIS symbol Effective sectional area 70mmEXH PORT Operating temperature 5 to 60 degrees C Air connection port size Rc3/8 Weight 0.kg 5mm EXH PORT 5 to 60 degrees C Rc/ 0.69kg Remark: The above are standard TOMOE-compatible quick exhaust valves. It is also possible to install quick exhaust valves other that those listed above. For details, please consult us. TGA Booster relay Purpose A booster relay is used to make switching time shorter and to improve response in cases when the piping distance from the meters and the actuator is very far, and when the capacity of the actuator is very large, or when the actuator has a large control valve with a positioner. Standard specifications Manufacturer IL00-03 JIS symbol Output flow rate 600L/min (SUP=0.5MPa) Air consumption Within 3L/min. (OUT=0.MPa) Operating temperature 5 to 60 degrees C Repeatability Within %FS Hysterisis Within %FS Air connection port size Rc3/8 Signal pressure connection port Rc/ Weight 0.56kg Remark: The above is a standard TOMOE-compatible booster relay. It is also possible to install booster relays other than that listed above. For details, please consult us. TGA-8

TGA Examples of standard air circuits for pneumatic actuators Double-acting type Standard and semi-standard accessories and their use Example of standard air circuit for on/off operation (double-acting type) Shown below are standard circuits to open and close a butterfly valve driven by a double-acting air cylinder while transmitting electrical signals from a remote control room. Switching of the flow of operation air is performed by the solenoid valve, and detection of the open/close position of the valve is performed by a limit switch, with feedback of the electrical signals to the control room. 5-way solenoid valve (single solenoid) Butterfly valve opens when solenoid valve is energized. Reducing valve with filter Open when pressurized Closed when pressurized Supply air min. 0. MPa Limit switch Butterfly valve Air filter Regulator Lubricator Butterfly valve closes when solenoid valve is energized. Reducing valve with filter 5-way solenoid valve (single solenoid) Open when pressurized Closed when pressurized Supply air min. 0. MPa Limit switch Butterfly valve 3 Butterfly valve closes when SOL. is energized. Butterfly valve opens when SOL. is energized. 5-way solenoid valve (single solenoid) Reducing valve with filter Open when pressurized Closed when pressurized Supply air min. 0. MPa Limit switch Butterfly valve Once SOL. is energized, the condition is maintained even after it is de-energized unless SOL. is energized. TGA-9

TGA Example of standard air circuits for pneumatic actuators Double-acting type Example of standard air circuit for control operation (double-acting type) Shown below are examples of standard circuits in which a P/P or E/P positioner is attached to the butterfly valve driven by a double-acting pneumatic cylinder to give instruction signals from a remote control room to the positioner. This adjusts the valve opening exactly and quickly in proportion to the signals, and also detects the open/close position of the valve by a limit switch which sends feedback of the electrical signals to the control room. Direct action Butterfly valve closes when signal increases. Butterfly valve opens when signal decreases. SHUT Valve motion OPEN 60 00 Signal current: to ma Signal pressure: to 00kPa Supply air min. 0. MPa (kpa) Signal pressure (ma) Signal current Open when pressurized Closed when pressurized Limit switch Butterfly valve Positioner (pneumatic-pneumatic or electro-pneumatic) Reducing valve with filter The butterfly valve opens fully when the input signal goes off under a state of assured air supply. 5 Reverse action Butterfly valve opens when signal increases. Butterfly valve closes when signal decreases. SHUT Valve motion OPEN Supply air min. 0. MPa 60 00 Signal current: to ma Signal pressure: to 00kPa (kpa) Signal pressure (ma) Signal current Open when pressurized Closed when pressurized Limit switch Butterfly valve Positioner (pneumatic-pneumatic or electro-pneumatic) Reducing valve with filter The butterfly valve closes fully when input signal goes off under a state of assured air supply. TGA-