TLT Telescopic pillar Very small built-in dimension Powerful Standards EN/IEC 661 1 UL 661 1
Technical data Unit TLT1 A1 TLT1 A2 TLT1 B1 TLT1 C1 TLT1 C2 Rated push load N 3 4 2 1 2 Rated pull load N Bending load Nm up to 4 1) up to 1 1) up to 25 1) up to 11 1) up to 48 1) Speed (full load to no load) mm/s 11 to 16 13 to 19 13 to 19 25 to 36 25 to 42 Telescopic pillar version # of section 3-section 3-section 3-section 3-section 3-section Stroke mm 3 to 7 3 to 7 3 to 7 3 to 7 3 to 7 Retracted length mm,5 S+17,5 S+24,5 S+17,5 S+17,5 S+24 Voltage V DC 24 24 24 24 24 Power W 168 168 192 192 216 Current A 2 3,5 2 3,5 2 4,5 2 4,5 2 4,5 Duty cycle: intermittent operation min. 1 min./9 min 1 min./9 min 1 min./9 min 1 min./9 min 1 min./9 min Ambient temperature C +1 to +4 +1 to +4 +1 to +4 +1 to +4 +1 to +4 Type of protection IP 4 4 4 4 4 Protection class SELV SELV SELV SELV SELV Type of control electrical electrical electrical electrical electrical Weight kg 15 to 3 15 to 3 15 to 3 15 to 3 15 to 3 1) For details, please see bending load diagrams 2
Performance diagrams Speed-load diagram Speed [mm/s] 4 36 32 28 24 2 16 12 8 4 1 2 3 4 Speed [mm/s] 5 45 4 35 3 25 2 15 1 5 1 2 3 4 Current-load diagram Current consumption [A] 5, 4,5 4, 3,5 3, 2,5 2, 1,5 1,,5 1 2 3 4 Current consumption [A] 5, 4,5 4, 3,5 3, 2,5 2, 1,5 1,,5 1 2 3 4 A1 B1 C1 A2 C2 Bending load diagrams Bending load diagram A1, B1, C1 3 2 8 Overload range 2 6 2 4 2 2 2 1 8 1 6 1 4 1 2 Ideal load range 1 8 6 4 2 Under load range 5 1 15 2 25 3 Load distance from center of pillar [mm] Bending load diagram A2, C2 4 3 5 Overload range 3 2 5 2 Ideal load range 1 5 1 5 Under load range 1 2 3 4 5 Load distance from center of pillar [mm] TLT1 A-1 TLT1 B-1 TLT1 C-1 TLT1 A-2 TLT1 C-2 3
Dimensional drawing 22 2 22 19 11 11 17 2 Supporting plate Stroke ±4 Retracted length ±4 (without mounting plates) 15 11 25 25 129 4 1 3 mm deep 146 163 Supporting plate 22 19 146 4 1 3 mm deep 146 17 2 Legend: S = stroke L = retracted length 15 22 11 ax. length 2 3 mm Note: mounting plates are not included. To be ordered separately. Suitable control units and accessories Connection diagram Control unit SCU VCU BCU CU TLT DIN Plug 24 V DC + - 5V+ GND 1+7 2+4 Blue DIN8 plug 1,5K 1,5K Hall A Hall B 3 5 6 8 1+7 2+4 3 5 6 8 Blue DIN8 plug 1,5K 1,5K Hall A Hall B Operating switches 2 Hallsensors signal 2 Hallsensors signal EHA 1 EHA 3 STF STJ Jack Plug 24 V DC + - 5V+ GND STA STE Black Black Hand switch Foot switch Desk switch 1) Only valid with TLG11. TLG1 must be operated by a BCU, CU, SCU or VCU control unit. 4
Ordering key T L T 1 Type Voltage 24 V DC 24 V DC with integrated current cut-off (only for A2 and C2) 1 Load / Speed 4 N A2 3 N A1 2 N / 19 to 13 mm/s B1 2 N / 42 to 25 mm/s C2 1 N C1 Stroke [S] 3 mm 3 4 mm 4 5 mm 5 6 mm 1) 6 7 mm 1) 7 Cable / connecting plug Straight, 1, m / jack plug 1 Straight, 2,3 m / jack plug 2 Coiled,,6 m / jack plug A Straight, 1, m / DIN8 plug 3 Straight, 2,3 m / DIN8 plug 4 Coiled,,6 m / DIN8 plug B Option No option 1-Hall encoder, 8 pulses, cable with jack plug A Cable feedthrough, 3x1,5 mm 2, top +16 mm, bottom +8 mm C Cable feedthrough, 1-Hall encoder D 2-Hall encoder, cable with DIN8 plug F 1) uced safety factor Options written in blue are only available on demand. Please contact SKF. Accessories Designation Order number Top mounting plate ZPL-29268 125624 Bottom mounting plate ZPL-29265 125623 Screw (4/plate) for mounting plate ZBE-5177 12536 5
skfmotiontechnologies.com SKF is registered trademarks of the SKF Group. SKF Group 218 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. PUB L5322.167/1 EN November 218