C2NX-XLP P/N _F NSF. Certified. Technical Data Sheet. April Spanish P/N

Similar documents
C2NX-EP P/N _B NSF. Certified. Technical Data Sheet. April Spanish P/N

C2X-EP P/N _P NSF. Certified. Technical Data Sheet. April Spanish P/N

C2X-LEP P/N _R NSF. Certified. Technical Data Sheet. April Spanish P/N

C2X-LE P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. October Spanish P/N

B4X-E P/N _L NSF. Certified. Technical Data Sheet. April Spanish P/N

M5NX-EP P/N _J NSF. Certified. Technical Data Sheet. April Spanish P/N

P2X-EP P/N _J NSF. Certified. Technical Data Sheet. April 2017

C6X-LEP P/N _Q NSF. Certified. September Spanish P/N Technical Data Sheet

FL5NX-LEP P/N _L. Technical Data Sheet. April Spanish P/N Item Part # Description Wiring Item #

ME5X-GP P/N _G NSF. Certified. Technical Data Sheet. April Spanish P/N

C5X-EP P/N _L NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

M5X-EP Technical Data Sheet

M4X-EP P/N _M NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

D5X-EP Technical Data Sheet

CF5X P/N _J NSF. Certified. Technical Data Sheet. October Scan QR code to access product information on your mobile device.

D6NX-LEP P/N _Q NSF. Certified. Technical Data Sheet. February Scan QR code to access product information on your mobile device.

D5X-E P/N _M NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

DDF5NX-L. Certified. Technical Data Sheet P/N _E NSF. January 2018 B A. Scan QR code to access product information on your. mobile device.

P2X-E P/N _L NSF. Certified. Technical Data Sheet. October 2017

DD5NX-L. Certified. Technical Data Sheet P/N _H NSF. July Scan QR code to access product information on your mobile device.

D5X-HEP P/N _P NSF. Certified. Technical Data Sheet. February Scan QR code to access product information on your mobile device.

DD5X-ULP IMPORTANT. Certified. Technical Data Sheet P/N _K NSF. July Scan QR code to access product information on your mobile device.

DD5X-LP. Certified. Technical Data Sheet P/N _K NSF. July Scan QR code to access product information on your mobile device.

DD6NX-L Technical Data Sheet

D6X-ULEP Technical Data Sheet

SMGT Technical Data Sheet

SMGV Technical Data Sheet

DD6X-URE P/N _G NSF IMPORTANT. Certified. Technical Data Sheet. April Spanish P/N

DD5X-LR P/N _J NSF. Certified. Technical Data Sheet. April Scan QR code to access product information on your mobile device.

DD6X-ULP Technical Data Sheet

DF5NX P/N _J NSF. Certified. Technical Data Sheet. January Scan QR code to access product information on your mobile device.

P4X-E. P/N _J NSF Certified P/N_ _J. Technical Data Sheet. September Item Part # Description Wiring Item #

P2X-E. P/N _J NSF Certified P/N_ _J. Technical Data Sheet. September Item Part # Description Wiring Item #

RI4 P/N _G NSF. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. November Serial Plate

CW2EGE C E. Technical Data Sheet P/N _B NSF. Certified. November Item Part # Description Wiring Item #

PW-E. Certified. Technical Data Sheet P/N _E NSF. October 2016

PWW-E. Certified October Technical Data Sheet P/N _C NSF

LED FIXTURES AND POWER SUPPLY. (C) Power Supply (D)

C5NX-LE P/N _L NSF. Certified. Technical Data Sheet. April Spanish P/N

RMT with P/N _H NSF. INNOVATOR Doors or INNOVATOR III Doors. Certified. Technical Data Sheet. June 2015

C2X-LEP. P/N _K NSF Certified F E P/N_ _K. Technical Data Sheet. April Item Part # Description Wiring Item #

EQUIPMENT INFORMATION SHEET REFRIGERATION - MEDIUM TEMP. Link to PDF file

ESBDHV Technical Data Sheet

ESBD P/N _D NSF. Certified G K B E G F H K A. Technical Data Sheet. April Spanish P/N Data sheet-elite-esbd

ESGMVS Technical Data Sheet

M3X-GE. P/N _F NSF Certified P/N_ _F. Technical Data Sheet. March 2010 F E B E. Item Part # Description Wiring Item #

M5X-GE. P/N _E NSF Certified P/N_ _E. Technical Data Sheet. March Item Part # Description Wiring Item #

Electrical Box. Optional. Condensing Unit (Field Installed)

Optimal Shelf Life. Conventional Controls IP4NL. Low Pressure Backup Control CI/CO 8 20 F / 10 F 6.67 C / 12.2 C

ESGM Technical Data Sheet

Insight IC2SL P/N _J NSF. Certified. Dairy / Delicatessen / Meat

Insight IC6SL P/N _L NSF. Certified. Dairy / Delicatessen / Meat

Optional Condensate Pan. Electrical Box

CW2UGE E G A D. Certified. Technical Data Sheet P/N _B NSF. November Item Part # Description Wiring Item #

FL5NX-LEP P/N _F E D A D B D P/N_ _F. Technical Data Sheet. March Item Part # Description Wiring Item #

Insight ID5SL P/N _L NSF. Certified. Dairy / Delicatessen / Beverage

Insight ID6SU P/N _K NSF IMPORTANT. Certified. Dairy / Delicatessen

Insight IC4BM P/N _E NSF. Certifi ed. Dairy / Delicatessen / Meat / Produce

Optional Condensate Pans

Insight IDD5SU P/N _L NSF IMPORTANT. Certified. Dairy / Delicatessen / Beverage with EcoVision Doors

Insight IM1SL P/N _H NSF. Certifi ed. Meat. Insight standard field electrical connections are at the bottom of the merchandiser.

Insight IP1SL P/N _F NSF. Certifi ed. Bulk Produce. Insight standard field electrical connections are at the bottom of the merchandiser

C2-LE P/N G. P/N _G NSF Certified. Technical Data Sheet. November 2009

Fan Speed Selector (when applicable)

C2-LGE P/N D. P/N _D NSF Certified. Technical Data Sheet. November 2009

Insight ID5SMI45 P/N _B NSF. Certified. Dairy / Delicatessen / Beverage

Insight ID5NL P/N _H NSF. Certifi ed. Dairy / Delicatessen / Meat

Insight IC4SL P/N _F NSF. Certifi ed. Dairy / Delicatessen / Beverage / Meat

Insight IDD5SV P/N _E NSF. Certifi ed. Dairy / Delicatessen / Beverage with EcoVision Doors

Insight ID5NM P/N _J NSF. Certifi ed. Dairy / Delicatessen / Meat

Insight ID5SM P/N _K NSF. Certifi ed. Dairy / Delicatessen / Beverage

ONE FLOOR DRAIN IS REQUIRED FOR EACH CASE. NSF

Elevated C2-LE P/N D. NSF Certified. Technical Data Sheet. February Note: Changed items have been underlined.

ONE FLOOR DRAIN IS REQUIRED FOR EACH CASE. NSF

C2-XGE P/N C. NSF Certified. Technical Data Sheet. February 2006

F2XLG Technical Data Sheet

CW2UGE Technical Data Sheet

M5 Technical Data Sheet

D5RRI P/N B. NSF Certified. Technical Data Sheet. June 2006 P/N B. Item Part # Description Wiring Item #

D5RRIS. P/N B NSF Certified. Technical Data Sheet. June 2006 P/N A. Item Part # Description Wiring Item #

M1-GEB Technical Data Sheet

CW2U-XGE. Technical Data Sheet P/N B. NSF Certified E G F A D C. April Note: Changed items have been underlined.

Insight ID5SM-W U L US C P/N _B NSF. Certified LISTED. Dairy / Delicatessen / Beverage Water-coooled Self-Contained R290 (Propane)

Double Curved Glass. Merchandisers NEBCH. (Modified Front for Impact) Data Sheet Set P/N A. June, 1998 LAMPS AND BALLASTS

Electrical Box Power Cord

INNOVATOR DOOR SYSTEM FOR WALK-IN COOLERS

Ambient Pastry Case Family

INNOVATOR DOOR SYSTEM FOR WALK-IN COOLERS

Self-Contained PRICE LIST. April

INNOVATOR AND INNOVATOR II

IMPACT 3-Pin Shelf Lamp LED Retrofit for Hussmann Cases Manufactured AFTER February 2001

IDP INNOVATOR DOOR PROTECTOR. P/N _B July 2012 P/N_ _B HUSSMANN MODEL NO

EcoShine II Horizontal LEDs

EXCEL. Medium Temp Display Case. Far More Energy Efficient. Greater Merchandising Capacity. Enabling excellence in food retailing.

EcoShine II Vertical LED Lights

EcoShine II and EcoShine II Plus LED Lights

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

Innovator, Innovator II & Innovator III

O2.5UMAK-NRG O2.5UMAK-NRG. Multi-Deck Mobile Self-Contained Merchandiser 4', 6' & 8' Case (Meal Kit) SHIPPING WEIGHT GENERAL NOTES

EcoShine Quick Connect LED Lights

Transcription:

C2NX-XLP Technical Data Sheet NSF Certified April 2017 Scan QR code to access product information on your mobile device. We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # Description Wiring Item # FAN ASSEMBLIES 4 Ft, 8 Ft & 12 Ft A. 7W Standard Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator (MO.4410545) 0142780 Fan Blade (FB.0142780) 6 Ft Only A. 4W Standard Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0382383 Fan Blade (FB.4780617) THERMOSTATS B. Optional Adjustable Refrigeration Thermostat (2) HEATERS C. 0512499 Canopy Anti-Sweat Heater (3) 4 ft (HE.4851174) 0512500 6 ft (HE.4851175) 0512501 8 ft (HE.4851176) 0512503 12 ft (HE.4851178) Data sheet-excel C2NX-XLP Item Part # Description Wiring Item # LAMPS AND BALLASTS D. Ballast, Electronic (4) 0508087 1 lamp (BA.4482491) 0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677) E. Fluorescent Lamp (5) Replace with like fixtures LED FIXTURES AND POWER SUPPLY F. 0501213 Power Supply (EP.4481861) (6) G. LED Canopy Fixture (7) Replace with like fixtures H. LED Shelf Fixture (8) Replace with like fixtures Note: Revision F: April 2017. Updated LED energy values. Other changes marked with a bar, circle or underline. 2017 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0539999

Engineering Plan Views 01-2005 C2NX Dimensions shown as inches and (mm). PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 7 /8 3 In. (77 mm) Required Air Gap Electrical Field Connection Electrical Stub Up Area 6 x 6 (152 x 152) Waste Outlet Wireway Refrigeration Outlet Waste Outlet Splashguard NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD. FRONT 4 ft 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) 48 3 /8 (1229) 72 3 /8 (1838) 96 3 /8 (2448) 144 1 /2 (3670) (Each end and insulated partition adds 1 1 /2 in. (38 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 37 (940) 37 (940) 37 (940) 37 (940) Back of case to front of splashguard 28 1 /2 (724) 28 1 /2 (724) 28 1 /2 (724) 28 1 /2 (724) Back of case to O/S edge of front leg 25 1 /4 (641) 25 1 /4 (641) 25 1 /4 (641) 25 1 /4 (641) Distance between edges of external legs and center legs NA 29 1 /2 (750) 41 1 /2 (1054) 41 1 /2 (1054) Distance between edges of center legs NA NA NA 43 7 /8 (1114) Distance between front legs and splashguard 2 3 /4 (70) 2 3 /4 (70) 2 3 /4 (70) 2 3 /4 (70) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 36 1 /4 (921) 60 1 /4 (1530) 84 1 /4 (2140) 132 3 /8 (3363) Back of case to center of stub up area 19 (483) 19 (483) 19 (483) 19 (483) Length of electrical wireway Wireway 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) (C) RH End of case to LH end of wireway 42 1 /8 (1070) 66 1 /8 (1680) 90 1 /8 (2289) 138 1 /4 (3511) Waste Outlets (One each end) (D) RH End of case to the center of LH waste outlet 36 1 /4 (921) 60 1 /4 (1530) 84 1 /4 (2140) 132 3 /8 (3363) RH End of case to the center of RH waste outlet 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) Back O/S of case to center of waste outlets 26 3 /4 (680) 26 3 /4 (680) 26 3 /4 (680) 26 3 /4 (680) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) Refrigeration Outlet Back of case to center of refrigeration outlet 21 1 /4 (540) 21 1 /4 (540) 21 1 /4 (540) 21 1 /4 (540) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203) 2 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 C2NX-XLP Technical Data Sheet

Multi-deck, 4 Display Levels, Low Front, 55 In. Back, Narrow Footprint C2NX-XLP See Page 10 for shelf arrangement. Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Dimensions shown as inches and (mm). Refrigeration Outlet LOAD LIMIT LINE FAN 3 In. (77 mm) Required Air Gap C O I L REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. C2NX-XLP Dairy/Deli/Produce Meat UNLIT LIT UNLIT LIT Discharge Air F 33 31 30 28 Evaporator F 28 26 25 23 Unit Sizing F 26 24 23 21 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. Btu/hr/ft Unlit Shelves Excel C2NX-XLP C2NX-XLP Dairy/Deli/Produce Meat PARALLEL Unlit 954 1004 CONVENTIONAL Unlit 995 1048 Add 10 Btu/hr/ft per shelf row for LED fixtures. Add 20 Btu/hr/ft per shelf row for fluorescent lamps. Electrical Case to Case Connections NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. Estimated Charge ** C2NX-XLP 4 ft 1.6 lb 26 oz 0.7 kg 6 ft 2.3 lb 37 oz 1.0 kg 8 ft 3.2 lb 51 oz 1.5 kg 12 ft 4.5 lb 70 oz 2.0 kg **This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound (8 oz/0.2 kg). DEFROST DATA C2NX-XLP C2NX-XLP Dairy/Deli/Produce Meat Frequency (hr) 8 12 Defrost Water (lb/ft/day) 6 (±15% based on case configuration and product loading.) OFFTIME C2NX-XLP Time (minutes) 30 ELECTRIC OR GAS Not Recommended CONVENTIONAL CONTROLS Low Pressure Backup Control C2NX-XLP Dairy/Deli/Produce Meat CI/CO* 19 F / 9 F 16 F / 6 F Indoor Unit Only, Pressure Defrost Termination* 48 F *Use a Temperature Pressure Chart to determine PSIG conversions. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 11

Excel C2NX-XLP Electrical Data 4 ft 6 ft 8 ft 12 ft Number of Fans 7W 1 2 3 Number of Fans 4W 2 Amperes Watts 4ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft Evaporator Fan 120V 50/60Hz Standard Energy Efficient 0.19 0.24 0.38 0.57 14 16 28 42 230V 50/60Hz Standard Energy Efficient 0.10 0.12 0.20 0.30 14 16 28 42 230V 60Hz Export 0.25 0.30 0.50 0.75 39 48 78 117 230V 50Hz Export 0.28 0.36 0.56 0.84 42 54 84 126 Minimum Circuit Ampacity 120V 50/60Hz Standard Energy Efficient 0.39 0.44 0.58 0.77 230V 50/60Hz Standard Energy Efficient 0.30 0.32 0.40 0.50 230V 60Hz Export 0.45 0.50 0.70 0.95 230V 50Hz Export 0.48 0.56 0.76 1.04 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti-sweat Heaters 120V 50/60Hz Standard 0.10 0.15 0.20 0.30 12 18 24 36 Standard Lighting (T-8 Fluorescent) 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85 ONLY LIGHTING CONFIGURATIONS THAT ARE COMPLIANT WITH THE U.S. DEPT. OF ENERGY (DOE) 2017 REGULATION ARE AVAILABLE FOR SALE FOR USE IN THE U.S.A. Optional Lighting (T-8 Fluorescent) Additional 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85 1 Row Rail Light 0.26 0.51 0.51 0.77 30 59 59 85 3 Rows of Shelves 0.77 1.53 1.53 2.31 90 177 177 255 EcoShine II HO 1 Row Canopy 0.22 0.33 0.44 0.66 26.5 39.5 53.0 79.4 EcoShine II Rail Light 1 Row 0.08 0.12 0.16 0.25 9.9 14.1 19.8 29.7 EcoShine II Shelf 2 Rows of Shelves 0.16 0.23 0.33 0.49 19.8 28.2 39.5 59.3 3 Rows of Shelves 0.25 0.35 0.49 0.74 29.7 42.3 59.3 89.0 120V Fluorescent Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 120V LED Lighting Circuit Total = Canopy Lighting + Shelf Lighting + Optional Rail Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52 MCA does not include Canopy A/S Heaters because heaters are wired separately from fans. Please note: some combinations of fluorescent lights on this case model may not be compliant with DOE 2017 and may not be available to order in the US and Canada. More lighting options are available with LED lights. The Hussmann Product Configurator will not allow lighting options that do not comply with the DOE 2017 standards. 4 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 C2NX-XLP Technical Data Sheet

Excel C2NX-XLP Product Data Recommended Usable Cube 1 (Cu Ft/Ft) AHRI Total Display Area 2 (Sq Ft/Ft) Shelf Area 3 (Sq Ft/Ft) 3.62 ft 3 /ft (0.34 m 3 /m) 3.33 ft 2 /ft (1.01 m 2 /m) 6.38 ft 2 /ft (1.94 m 2 /m) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (1) row of 12-inch shelf, (1) row of 16-inch shelf and (1) row of 18-in shelf. from fans. ESTIMATED SHIPPING WEIGHT 4 Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 600 (272) 800 (363) 1000 (454) 1200 (544) 75 (34) 4 Actual weights will vary according to optional kits included. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 11

Fan Wiring Offtime Defrost 1, 2 & 3 Fans 6 ft 2 Fans 8 ft 2 Fans 12 ft 3 Fans 120V NEUTRAL 120V POWER BROWN BAND Fans BROWN BAND Refrigeration Thermostat 4 ft 6 ft or 8 ft 12 ft Light Blue To Condensing Unit Light Circuits Field Connections Ballast Plug for Optional Light Rail (if applied) Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy Connector 4-Ft 6-Ft or 8-Ft 12-Ft Case Ground Bar Optional Two Row Canopy Optional Lighting 1 Row Rail Connector 4-Ft 6-Ft or 8-Ft 12-Ft WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White = 120V POWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND 6 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 C2NX-XLP Technical Data Sheet

120V Power 120V Neutral Canopy Anti-Sweat Heater Purple BAND Purple BAND Anti-Sweat Heater Optional Shelf Lighting Fluorescent Fixtures Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4-Ft Case 8-Ft Case 12-Ft Case WARNING WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White = 120V POWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 11

Optional Canopy and Rail Light Circuits LED Fixtures EcoShine II LED Canopy Lighting 1 Row Ballast Plug for Optional Light Rail (if applied) Ballast Plug for Optional Light Rail (if applied) Case Ground Bar Orange or Tan Band 4-Ft Case Case Ground Bar Orange or Tan Band 6-Ft or 8-Ft Case Ballast Plug for Optional Light Rail (if applied) Case Ground Bar Orange or Tan Band 12-Ft Case EcoShine II LED Rail Lighting 1 Row 4-Ft Case 6-Ft or 8-Ft Case 12-Ft Case WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White = 120V POWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND 8 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 C2NX-XLP Technical Data Sheet

Optional Shelf Lighting LED Fixtures Optional Shelf Harness and LED Light Circuits for 2 or 3 Rows of Shelves Connector Connector 4-Ft Case 6-Ft or 8-Ft Case Shelf Light Plug & Receptacle (TYP) 12-Ft Case WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red G = Green BL = Blue BK = Black W = White = 120V POWER = 120V NEUTRAL = FIELD GROUND = CASE GROUND HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 9 of 11

Excel C2NX-XLP SHELF CONFIGURATION This merchandiser is designed for two or three shelves. The depth of the shelf used in the top eight (8) shelf hole locations is critical to case performance. If a shelf is placed in one of the top eight (8) locations it must comply with the angle/depth requirements listed below. Top Eight (8) Shelf Hole Locations Shelf Angle Maximum Shelf Depth 0 º 12 in. Angle 0º Maximum Shelf Size 12 in. Do NOT load PRODUCT above this line 15 º 14 in. or less 15º 30º 14 in. 18 in. 30 º 18 in. or less 45º 0º 18 in. 18 in. 45 º 18 in. or less NOTE: Shelves placed in the lower positions may be up to 18 in. deep when positioned at a 0 º angle. 10 of 11 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 C2NX-XLP Technical Data Sheet

Excel C2NX-XLP The ballast for the canopy and shelf lamps is located behind the canopy on the left-hand end (when facing case) of the merchandiser. Light Channel To access the ballast: 1. Remove screws at bottom edge of canopy and rear of light channel. Remove Screws 2. Lower light channel which will pivot on hinge. 3. Service or replace ballasts as required. Ballast Light Channel Hinge 4. Reassemble items as they were originally installed. NOTE: Rail lamp ballast is located in the electrical raceway. Light Channel CANOPY ANTI-SWEAT HEATER The canopy anti-sweat heater location is shown below. Connections are in the electrical wireway. Canopy Foil-covered Anti-Sweat Heater Canopy Electrical Wireway Anti-Sweat Heater Wires with Purple Markers HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 11 of 11