PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Similar documents
HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Plate mounted axial flow fans HXBR / HXTR Series

COMPACT Series type HCFB / HCFT (Plastic impellers)

supplied in Form (B) configuration. Airflow over Impeller- Motor.

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

ACOUSTIC CABINET FANS CVAB / CVAT Series

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CENTRIFUGAL IN-LINE FANS VENT Series

ACOUSTIC CABINET FANS CVB / CVT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CGT Series Adjustable Pitch Fans

Short casing. Long casing (L version) Commercial premises

CGT Series Adjustable Pitch Fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Sabre Plate Mounted Sickle Fans (VSP)

CHMT Series, F Rated Fans

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

Axial fans. What s more, non-stock models are normally available within two weeks.

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Performance. Sound Levels. Impellers. Motors. Accessories

MIXVENT-TH Series Mixed Flow Fans

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Multifunctional 400ºC/2h and 300ºC/2h roof fans

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

AC Commercial Fans Edition. ErP ready

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Vent-Axia Sabre Sickle Roof Fans (VSR)

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

Sabre Sickle Fan Assisted Roof Cowls (VSR)

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

SILENT MV Ultra Quiet In-line Fans

High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. Fibreglass-reinforced plastic impeller.

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

AXIAL FLOW CABINET FAN CGT Series

Acoustic Twin Fans (ATQ)

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

AXIAL FANS Catalogue CN0050C01 May 2008

BELT DRIVEN CABINET FANS CVTT Series

Max. airflow m 3 /s Diam. min. Diam. max

CYLINDRICAL CASED AXIAL FLOW FANS

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor.

NEW WINDER. Impellers with higher efficiency and less sound level

Centrifugal medium-pressure fans fitted with multi-blade

Square Mixed Flow Fans (MFQ)

BATHROOM EXTRACT FANS DECOR-100 Series

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

HIGH-POWERED VENTILATORS

CVHT Series - F rated cabinet fans

Uniclass L7534. Manufacture controlled to ISO9001

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

NEW Acoustic In-Line Fans (ACQ)

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

WINDER. Impellers with higher efficiency and less sound level

Section 4 e c tio - P lat F a n s

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CMR/EW EFFICIENT WORK

NEW Slimpak EC Box Fan (SLPT EC)

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Mixed Flow Roof Fans (RMH)

GigaBox centrifugal fans Product specific information

BPF. Centrifugal Plug Fans

TD-ECOWATT AND DECOR-ECOWATT Series

CMP/EW EFFICIENT WORK

Medium Pressure Centrifugal Fans

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

Transcription:

A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller. The motor and fan impeller are supported within this mounting plate by strong electro-welded steel support frame. All models include a steel finger guard as standard mounted to the inlet side of the fan. The whole fan assembly is protected against corrosion by cataforesis primer and a polyester black paint finish (1). Available, depending upon the model, with single or three phase motors in 2, 4, 6, 8 or 12 poles (1) Models 800, 910 and 1000, fitted as standard with not painted motor-impeller. Motors All the motors are IP54, Class F insulation, equipped with thermal protection. Electrical supplies: Single phase 230V-50Hz. (Capacitor located inside the wiring terminal box). Three phase 400V-50Hz. (250 model: 230/400V-50Hz). All single phase models are speed controllable excepted /4-560, /4-630 and 710 models. All three phase models are speed controllable by Autotransformer except /4-560, /4-630 and models from 710 to 1000. Models from Ø800 to Ø1000 are speed controllable by inverter. Warehouses Workshops Commercial premises Car parks Agricultural extract or supply applications Additional Information Standard air direction: form (A) configuration (Motor over Impeller). All models are supplied with a pre-wired wiring junction box located on the back of the motor hub for easy access wiring. Greenhouses inting Installations Air conditioning equipment On request Air direction: form (B) configuration (Impeller over Motor). Three phase motors suitable for inverter control. (E22 version) Compact design Corrosion resistance Terminal box High efficiency Sickle blade impeller This very low profile design optimises airflow performances whilst minimising noise generation Mounting plate, motor support and finger proof guard protected by cataforesis primer and black polyester paint finish. Stainless steel screws Wiring terminal box with cable gland PG-11 (M20: from 800 to 1000 models) Sickle Blade impeller specifically designed to ensure the highest and most efficient airflow performance with the lowest noise level. Dynamically balanced to ISO 1940 standard. Manufactured from aluminium plate, except from 250 to 355 models which are manufactured from pressed sheet steel

Technical characteristics Before making any electrical connection ensure that the voltage and frequency of the mains electrical supply matches that of the fan data plate label. Model Voltage Operating temperature range Speed Maximum absorbed power Maximum absorbed current Minimum Maximum (r.p.m.) (W) at 230 V at 400 V SINGLE PHASE 2 POLES Sound pressure level (db(a)) Max. air volume (m 3 /h) Weight (kg) Speed controller HXBR/2-250 230V 50Hz -40 C +60 C 2650 120 0,55 58 1650 7,0 REB-1N SINGLE PHASE 4 POLES HXBR/4-250 230V 50Hz -40 C +60 C 1450 40 0,21 45 930 6,5 REB-1N HXBR/4-315 230V 50Hz -40 C +40 C 1400 120 0,53 53 2074 7 REB-1N HXBR/4-355 230V 50Hz -40 C +60 C 1400 120 0,55 59 2970 7,5 REB-1N HXBR/4-400 230V 50Hz -40 C +65 C 1360 290 1,2 60 5080 9 REB-2,5N HXBR/4-450 230V 50Hz -40 C +50 C 1370 410 1,85 64 7649 11,5 REB-2,5N HXBR/4-500 230V 50Hz -40 C +70 C 1350 995 4,1 69 9957 16 REB-5 HXBR/4-560 230V 50Hz -40 C +45 C 1300 1300 6 70 12460 21,5 - HXBR/4-630 230V 50Hz -40 C +40 C 1320 1300 5,7 72 14518 24 - SINGLE PHASE 6 POLES HXBR/6-400 230V 50Hz -40 C +50 C 880 125 0,55 51 3387 9 REB-1N HXBR/6-450 230V 50Hz -40 C +60 C 850 200 0,9 55 5099 11,5 REB-2,5N HXBR/6-500 230V 50Hz -40 C +70 C 840 310 1,3 60 6638 16 REB-2,5N HXBR/6-560 230V 50Hz -40 C +65 C 820 440 2,14 61 8307 21,5 REB-2,5N HXBR/6-630 230V 50Hz -40 C +40 C 770 670 2,9 63 12315 24 REB-5 HXBR/6-710 230V 50Hz -40 C +40 C 835 850 3,6 66 16668 27 - THREE PHASE 2 POLES HXTR/2-250 230/400V 50 Hz -40 C +60 C 2700 110 0,40 0,23 57 1650 7,0 RMT-1,5 THREE PHASE 4 POLES HXTR/4-250 230/400V 50 Hz -40 C +60 C 1450 50 0,35 0,2 46 930 6,5 RMT-1,5 HXTR/4-315 400V 50Hz -40 C +70 C 1420 130 0,46 53 2074 7 RMT-1,5 HXTR/4-355 400V 50Hz -40 C +70 C 1400 150 0,42 59 2970 7,5 RMT-1,5 HXTR/4-400 400V 50Hz -40 C +60 C 1340 300 1 60 5080 9 RMT-1,5 HXTR/4-450 400V 50Hz -40 C +60 C 1360 520 1,15 64 7649 11,5 RMT-1,5 HXTR/4-500 400V 50Hz -40 C +70 C 1370 970 1,9 69 9957 16 RMT-2,5 HXTR/4-560 400V 50Hz -40 C +70 C 1340 1400 2,5 70 12460 21,5 - HXTR/4-630 400V 50Hz -40 C +60 C 1330 1400 2,5 73 14518 24 - THREE PHASE 6 POLES HXTR/6-400 400V 50Hz -40 C +70 C 950 120 0,4 51 3387 9 RMT-1,5 HXTR/6-450 400V 50Hz -40 C +60 C 950 160 0,5 55 5099 11,5 RMT-1,5 HXTR/6-500 400V 50Hz -40 C +70 C 900 270 0,62 60 6638 16 RMT-1,5 HXTR/6-560 400V 50Hz -40 C +70 C 860 450 0,9 61 8307 21,5 RMT-1,5 HXTR/6-630 400V 50Hz -40 C +60 C 880 740 1,5 63 12315 24 RMT-2,5 HXTR/6-710 400V 50Hz -40 C +40 C 920 1000 2,6 66 16668 27 - HXTR/6-800 400 V 50Hz -40 C +50 C 890 1900 3,5 67 25800 46 - THREE PHASE 8 POLES HXTR/8-800 400 V 50Hz -40 C +70 C 630 760 1,83 60 19090 45 VFKB-45 THREE PHASE 12 POLES HXTR/12-800 400 V 50Hz -40 C +70 C 440 300 0,8 51 12640 43 VFKB-45 HXTR/12-910 400 V 50Hz -40 C +50 C 440 690 2,2 55 20600 55 VFKB-45 HXTR/12-1000 400 V 50Hz -40 C +50 C 420 890 1,9 56 26000 61 VFKB-45

Acoustic characteristics The sound levels NPS- shown in the technical characteristic chart, correspond to the value of sound pressure db(a), measured in free field conditions at a distance equivalent to three times the diameter of the impeller with a minimum of 1.5 meters. Sound power level spectrum in db(a) at the corresponding octave band average frequencies in Hz. Mounting accessories LwA ASP Q max. 63 125 250 500 1000 2000 4000 8000 01/02/50 47 45 55 61 66 68 66 59 01/04/50 34 31 42 48 53 55 53 46 01/04/15 38 50 53 62 62 62 57 47 01/04/55 37 54 58 67 70 68 62 52 01/04/00 39 56 62 66 70 70 65 58 01/04/50 42 59 66 70 73 74 69 62 01/04/00 42 64 71 76 81 76 70 60 01/04/60 51 64 71 80 80 78 74 65 01/04/30 54 68 74 81 83 80 74 66 01/06/00 30 47 53 57 60 61 56 49 01/06/50 33 50 57 61 64 65 60 53 01/06/00 33 55 61 66 72 67 60 50 01/06/60 42 55 62 71 71 69 65 56 01/06/30 45 59 65 72 74 70 65 57 01/06/10 48 61 68 75 76 73 67 59 01/06/10 48 61 68 75 76 73 67 59 01/06/00 52 67 66 69 72 73 70 64 01/12/00 52 56 64 62 65 61 59 53 Exhaust side Louvre shutters Wire guard Model Plastic Aluminium 250 DEF-250 D PER-250 W PER-250 CN 315 DEF-325 D PER-355 W PER-355 CN 355 DEF-375 D PER-355 W PER-355 CN 400 DEF-450 D PER-400 W PER-400 CN 450 DEF-450 D PER-450 W PER-450 CN 500 DEF-525 D PER-500 W PER-500 CN 560 DEF-630 D PER-560 W PER-630 CN 630 DEF-630 D PER-630 W PER-630 CN 710 DEF-800 D PER-710 W PER-710 CN 800 DEF-800 D PER-800 W PER-800 CN 1000 DEF-1000 D PER-1000 W PER-1000 CN Electrical accessories REB-1N / REB-2,5N Electronic, single phase speed controllers REB-5 Electronic single phase speed controller RMB/RMT Auto-transformer speed controller RMB single phase 230V RMT three phase 400V REB-4 Auto REB-5 Auto Electronic single phase speed controllers with temperature sensor. For agricultural applications VFKB IP65 Adjustable frecuency drives for three phase motors 400V VFTM IP21/IP54 Adjustable frecuency drives for three phase motors 230V or 400V

Dimensions (mm) Model A B C D D1 D2 E F FT J K L M Single phase Three phase Single /2 /4 /6 /2 /4 /6 phase 250 315 260 220 250 261 290 10 10,5 0-10,5 0-126 126 33 53 12 73 73 315 400 330 280 315 320 365 10-0 - - 0-149 149 41 68 12 82 82 355 450 380 315 355 363 411 10-0 - - 0-156 156 41 75 12 82 82 400 500 420 355 400 410 464 10-12 - - 0-200 176 92 78 12 122 97 450 560 480 400 450 457 522 10-0 0-0 0 204 179 68 91 12 114 89 500 630 560 450 500 512 572 10-13 0-13 0 201 176 60 97 12 104 79 560 710 630 510 559 570 649 10-20 0-20 0 213 188 70 99 12 114 89 630 800 710 580 630 640 730 12-25 25-25 7 207 182 60 103 12 104 79 710 900 800 637 710 810 12 - - 11 - - 11 221 206 115 92 17 130 115 Three phase Single phase Three phase Model a d p b r q s t u HXTR/6-800 788 205 960 797 17 170 910 970 14,5 HXTR/8-800 788 188 960 797 17 170 910 970 14,5 HXTR/12-800 788 165 960 797 17 170 910 970 14,5 HXTR/12-910 905 205 1115 914 22 210 1010 1070 14,5 HXTR/12-1000 990 205 1140 1000 22 210 1110 1170 14,5

Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Pst = Static pressure in and. Dry air at 20ºC and 760 mmhg. Performance data in accordance with ISO 5801 and AMCA 210-99 Standards. Typical fan selection: Do not select the working point in the coloured area. To find the working point first it is necessary to plot the system resistance curve. The working point lies at the intersection between that curve and the curve of the fan. Example: Required air volume 10.000 m 3 /h at 3. Fan working point 11.300 m 3 /h at 4. HXBR/2-250 HXTR/2-250 Do Not Select a Fan with a Working Point in this Area HXBR/4-560 HXTR/4-560 Required Air Volume HXBR/4-250 HXTR/4-250 Working Point of Fan HXBR/4-315 HXTR/4-315 HXBR/4-355 HXTR/4-355

Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Pst = Static pressure in and. Dry air at 20ºC and 760 mmhg. Performance data in accordance with ISO 5801 and AMCA 210-99 Standards. HXBR/4-400 HXTR/4-400 HXBR/4-450 HXTR/4-450 HXBR/6-400 HXTR/6-400 HXBR/6-450 HXTR/6-450 HXBR/4-500 HXTR/4-500 HXBR/6-500 HXTR/6-500