CHMT Series, F Rated Fans

Similar documents
CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CVHT Series - F rated cabinet fans

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

COMPACT Series type HCFB / HCFT (Plastic impellers)

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

ACOUSTIC CABINET FANS CVAB / CVAT Series

Multifunctional 400ºC/2h and 300ºC/2h roof fans

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

supplied in Form (B) configuration. Airflow over Impeller- Motor.

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

Short casing. Long casing (L version) Commercial premises

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

ACOUSTIC CABINET FANS CVB / CVT Series

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

Plate mounted axial flow fans HXBR / HXTR Series

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

VORTICENT C E RANGE Centrifugal fans

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH-POWERED VENTILATORS

CGT Series Adjustable Pitch Fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

BELT DRIVEN CABINET FANS CVTT Series

DIRECT-AIR ILB / ILT Series Rectangular duct fans

CGT Series Adjustable Pitch Fans

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Medium Pressure Centrifugal Fans

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

SQUIF HIGH TEMPERATURE FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CENTRIFUGAL IN-LINE FANS VENT Series

NCF fans 50 Hz. Protection class IP 55

TDF Double Inlet Backward Curve Centrifugal Fans

ROOFMASTER STEF-HT ROOF FAN

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

AC Commercial Fans Edition. ErP ready

Centrifugal medium-pressure fans fitted with multi-blade

Performance. Sound Levels. Impellers. Motors. Accessories

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

MAJAX-2 GENERAL SPECIFICATION

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Sabre Plate Mounted Sickle Fans (VSP)

AXIAL FANS Catalogue CN0050C01 May 2008

Powerful centrifugal fans for universal use: The product ranges TEM and REM

NCF 60 Hz. Protection class IP 55

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

Acoustic Twin Fans (ATQ)

Powerful centrifugal fans for universal use: The product ranges TEM and REM

CMR/EW EFFICIENT WORK

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

FEATURES & BENEFITS UPON REQUEST

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

MIXVENT-TH Series Mixed Flow Fans

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

CMP/EW EFFICIENT WORK

NCF fans 60Hz. Protection class IP 55

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

NEW Slimpak EC Box Fan (SLPT EC)

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

AXIAL FLOW CABINET FAN CGT Series

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

JE1, JE1 4 SERIES CONTENTS: Stainless Steel Construction Closed impeller Flow: 8 to 95 GPM Head: to 144 ft. Range of HP: to 3 HP

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

Hison Axial Flow Fans

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS

BPF. Centrifugal Plug Fans

Transcription:

CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke extraction in fire conditions and certified F400 120 (C marked). All casings are manufactured from electro-welded sheet steel protected against corrosion by grey epoxy-polyester paint coating. All models incorporate forward curved centrifugal impellers manufactured from galvanised sheet steel. Available, depending upon the model, with single or three phase motors in 4 or 6 poles. otors All motors are IP55, class. lectrical supply: Three phase 230/400V-50z up to 3kW. Three phase 400V-50z, for higher power 0 020382 603071 otor approved S1 and S2 Impellers dynamically balanced motors. (See characteristics chart). Additional Information The scroll can be orientated in 8 different positions as per the table below. Standard supplied position: LG 270. On request Fan supplied in RD positions. Fan fitted with 2-speed motor. A P P L I C A T I O N S F400-120 certified motors approved for running continuously (S1) or for emergency operation (S2) Forward curved centrifugal impellers dynamically balanced according to ISO 1940 standard, providing vibration free operation rkings Industrial and commercial kitchens Iron and steel industries Foundries P O S I T I O N S Standard position: LG 270. Special versions are supplied under request. 283

Technical characteristics Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency etc) match those of the intended electrical supply. Speed aximum aximum current aximum Sound Weight power air pressure absorbed (A) volume level odel (r.p.m.) (kw) 230 V 400 V (m 3 /h) (db(a)) (kg) 4 POLS TR PAS CT/4-225/90-0,55 1430 0,55 2,4 1,4 2600 71 34 CT/4-250/100-1,1 1390 1,1 4,7 2,7 3600 72 39,2 CT/4-250/100-1,5 1400 1,5 6,6 3,8 3900 73 41,5 CT/4-280/115-2,2 1400 2,2 9,5 5,5 5050 75 64 CT/4-315/130-2,2 1400 2,2 9,5 5,5 5450 72 70 CT/4-315/130-3 1400 3 13 7,5 6400 75 75 CT/4-315/130-4 1420 4 9,5 7100 78 80 CT/4-355/145-3 1400 3 13 7,5 6200 75 77 CT/4-355/145-4 1420 4 9,5 7700 78 82 CT/4-355/145-5,5 1440 5,5 12,5 9300 81 105 CT/4-355/145-7,5 1445 7,5 16 10700 83 113 CT/4-400/165-4 1420 4 9,5 7200 77 97 CT/4-400/165-5,5 1440 5,5 12,5 8300 80 120 CT/4-400/165-7,5 1445 7,5 16 10460 83 128 CT/4-450/185-5,5 1470 5,5 12,9 7560 83 130 CT/4-450/185-7,5 1470 7,5 16 9900 86 138 CT/4-500/205-11 1467 11 23 11250 87 163 CT/4-500/205-15 1470 15 31 15930 89 180 6 POLS TR PAS CT/6-315/130-1,1 965 1,1 3,3 5,7 5400 69 70 CT/6-355/145-1,1 965 1,1 3,3 5,7 6700 74 72 CT/6-400/165-2,2 975 2,2 3,7 6,3 7590 73 97 CT/6-450/185-2,2 975 2,2 3,7 6,3 7110 75 107 ATTNTION: The values of sound pressure levels, are values measured in db(a) at the fan discharge side at the maximum volume (Qmax). 284

Acoustic characteristics Sound power level spectrum in db(a) at the corresponding frequency band in z. SOUND LVL SPCTRU Description 63 z 125 z 250 z 500 z 1000 z 2000 z 4000 z 8000 z 4 POLS CT/4-225/90-0,75 55 67 74 75 80 81 77 73 CT/4-250/100-1,1 56 69 75 76 81 82 78 75 CT/4-250/100-1,5 56 69 75 76 81 82 78 75 CT/4-280/115-2,2 59 72 78 79 84 85 81 78 CT/4-315/130-2,2 56 69 75 76 81 82 78 75 CT/4-315/130-3 59 72 78 79 84 85 81 78 CT/4-315/130-4 62 75 81 82 87 88 84 81 CT/4-355/145-3 59 72 78 79 84 85 81 78 CT/4-355/145-4 62 75 81 82 87 88 84 81 CT/4-355/145-5,5 65 78 84 85 90 91 87 84 CT/4-355/145-7,5 66 79 85 86 91 92 88 85 CT/4-400/165-4 61 74 80 81 86 87 83 80 CT/4-400/165-5,5 64 77 83 84 89 90 86 83 CT/4-400/165-7,5 67 80 86 87 92 93 89 86 CT/4-450/185-5,5 67 80 86 87 92 93 89 86 CT/4-450/185-7,5 70 83 89 90 95 96 92 89 CT/4-500/205-11 71 84 90 91 96 97 93 90 CT/4-500/205-15 73 86 92 93 98 99 95 92 6 POLS CT/6-315/165-1,1 54 67 70 78 78 79 74 70 CT/6-355/145-1,1 56 69 72 80 80 81 76 72 CT/6-400/165-2,2 58 70 73 81 81 82 78 74 CT/6-450/185-2,2 60 73 76 84 84 85 80 76 Dimensions (mm) C D 225-315 355-500 A C D K B K B TOTAL Power Pressure at 1,5 m 4 POLS 85 71 93 78 93 78 96 81 97 82 92 77 95 80 98 83 98 83 101 86 102 87 104 89 6 POLS 84 70 86 72 87 73 90 76 A I N F P I N F P 11 U T U G V Q R S 11 G G Q U U V T R S odel A B C D F G I K L N P Q R S T U V CT max 225/90 386 452 180 144 140 216 180 128 203 234 256 181 280 279 10 220 250 200 50 27 250/100 427 503 290 168 165 250 205 145 228 252 282 197 310 313 10,5 228 260 225 74 27 280/115 467 547 320 183 180 300 220 170 243 292 320 215 340 363 10,5 245 275 240 95 27 315/130 525 630 340 203 200 320 240 180 263 325 354 238 390 383 11 322 352 230 140 20 355/145 566 707 435 231 227 280 133 159 291 365 394 250 445 343 11 420 450 333 136,5 30 400/165 628 792 435 254 249 320 150 185 334 410 438 270 495 404 11 402 438 327 133,5 30 450/185 709 898 391 288 284 360 164 202 368 463 485 302 560 444 11 502 538 340 140 30 500/205 795 984 526 319 315 450 182,5 250 409 513 535 345 610 544 11 613 653 435 187,5 30 285

rformance curves Q = Air volume in, m 3 /hr and m 3 /s. = Static pressure in and. Dry air at 20ºC and 760 mmg. Air flow data in accordance with the following standards: UN 100-212-89, BS 848, rt 1; ACA 210-85 and ASRA 51-1985. CT - 4 poles CT - 4 poles 286

rformance curves Q = Air volume in, m 3 /hr and m 3 /s. = Static pressure in and. Dry air at 20ºC and 760 mmg. Air flow data in accordance with the following standards: UN 100-212-89, BS 848, rt 1; ACA 210-85 and ASRA 51-1985. CT - 6 poles ounting accessories ➀ ➂ ➅ ➅ ➁ ø1 2 3 odel Inlet guard Inlet mounting Discharge CT ø flange mounting flange 225/90 KRJ-225 KBA-225 KBD-225 250/100 KRJ-250 KBA-250 KBD-250 280/115 KRJ-280 KBA-280 KBD-280 315/130 KRJ-315 KBA-315 KBD-315 355/145 KRJ-355 KBA-355 KBD-355 400/165 KRJ-400 KBA-400 KBD-400 G FC I 3 N 2 450/185 KRJ-450 KBA-450 KBD-450 500/205 KRJ-500 KBA-500 KBD-500 A B K J D KRJ Inlet guard KBA Inlet mounting flange KBD Discharge mounting flange odel of accessory A B C D F G I J K L N 225/90 279 219 143 224 256 180 203 45 10 256 280 9 65 8 250/100 313 253 168 250 290 205 228 45 10 282 306 9 65 8 280/115 363 303 183 280 340 220 243 50 10 320 348 9 65 8 315/130 383 323 203 315 360 240 263 50 11 354 382 9 65 8 355/145 343 283 231 355 318 266 291 50 11 394 422 9 65 8 400/165 404 324 254 400 370 300 334 55 11 438 464 9 65 8 450/185 444 364 288 450 404 328 368 55 11 485 515 9 65 8 500/205 544 454 319 500 500 365 409 60 11 535 565 9 65 8 287