Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6

Similar documents
Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9

Water analysis, QC and more:

10.6 Schedule of Accreditation

Discipline Chemical Testing Issue Date Certificate Number T-1695 Valid Until Last Amended on - Page 1 of & 2013.

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.

Tintometer -Group. Comparator Highlights. The system for colorimetric water analysis

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

APPENDIX D WATER QUALITY DATA

Physico-chemical Characterization of Water Body with Special Reference to Battery, Power Sources and Metal Plating Effluents

Radionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x

10.6 Schedule of Accreditation

Eraring Power Station - EPA Licence Coal Unloader - EPA Licence Environmental Monitoring Data July 2016

4 A village survey: Mandari, Lakshmipur

CHECKIT Comparator. with continuous colour scales. Pool & Spa Water Testing - January 2017

10.6 Scope of Accreditation

ION EXCHANGE (I) LTD INDUSTRIAL CHEMICAL DIVISION

Variation Notice with introductory note

MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Plate Heat Exchangers

COTTER CORPORATION CANON CITY MILLING FACILITY

Certificate of Accreditation

TECHNICAL SPECIFICATIONS

Thermal Exploitation of Wastes in Lignite Combustion Facilities

SAN ANTONIO WATER SYSTEM

ENGINEERED LUBRICANTS CO.

TEST REPORT Report No.: R-cn E-S2 Page 1 of 9

INDIA EMISSION REGULATIONS SUMMARY

Successful Implementation of Cormetech Catalyst. in High Sulfur Coal-Fired SCR Demonstration Project

ITS Caleb Brett India:

Septage Land Application Module

SERVICE. Condition Monitoring Service Oil Check Condition Monitoring. Lubricant analysis Schwingungsanalyse Vibration SmartCheck

Container MBW12K90MC Thursday 25 Jan 2007

Emissions Testing Report

10.6 Scope of Accreditation

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

ASTM Methods that are feasible with Metrohm instruments

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

OIL PT. Scheme Description. Oils and Fuels Analysis Proficiency Testing Scheme

PILOT SCALE STUDY ON ACID MINE WATER TREATMENT USING HIGH DENSITY SLUDGE TECHNOLOGY

PRODUCT SPECIFICATION

Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City

H HILMAR. June 7, 2077

UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No.

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

INTERPRETATION OF USED COOLANT ANALYSIS

ISO INTERNATIONAL STANDARD. Diesel engines NOx reduction agent AUS 32 Part 1: Quality requirements

Techenomics Oil Analysis Information

U. S. Census Bureau Production and Stocks of Inorganic Chemicals Summary MQ325A(09)-05 Issued July 2010

Spring 2015 Summary Report Residential Drinking Water Well Sampling LRI Landfill

TECHNICAL INFORMATION

U. S. Census Bureau Production and Stocks of Inorganic Chemicals Summary MQ325A(10)-05 Issued July 2011

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

Congratulations, Dorothy!

International Quality Assurance Exchange Program Schedule. Fuel Month Number Type Dispatch Date Closing Date

To the participants of AQS Baden-Württemberg Dear Madam or Sir,

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test

The Secrets of Pyrotechnic Whistles. Joseph A. Domanico VP Publications / Webmaster Crackerjacks, Inc.

The Supply of Road/Rail Pick-Up Vehicles

Tributary Water Quality Monitoring Program,

224 Sulfur Standards 224 Biodiesel 225 Crude Oil 225 Diesel 225 Isooctane 226 Mineral Oil 226 Residual Oil SCP SCIENCE

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOTTISH WATER CHARGES SCHEME

Strainer BOA-S PN 6/16/25 DN Type Series Booklet

Where oxygenates are used, ethers are preferred. Methanol is not permitted. (5)

Experiences with domestic waste treatment and co-processing of Solid Recovered Fuels (SRF)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Emissions Characterization of Three High Efficiency Wood Boilers

PM 2.5 Impacts From Ship Emissions in the Pacific Northwest. Robert Kotchenruther Ph.D. EPA Region 10 NW-AIRQUEST Meeting, June

The Purification Feasibilityof GlycerinProduced During

Rexro h. Service Visit Report. Bosch Group. For the attention of. Site Address: Aviemore, PH22 1RB. Customer Order Number: Visit Date:

Blade Fuses - Illuminated Mini Blade

150 Series Brass Horizontal Float Valve. Technical Information

Linea - Line. raccordi a compressione compression fittings

TRACE ELEMENTS IN URINE. Event #3, 2012

Temperature sensor type T.3., Construction type 3, plug-in sensor for protection tube with lateral cable outlet (Pt100/Pt1000, NTC)

MCF3 25CT Inrush-withstand

GLYCERIN PACKAGE 100mL $ Glycerin, Ibs/gallon, MONG Material Organic, Non-Glycerin, Ash, Specific Gravity, Moisture by Karl Fisher, Methanol

Non-exhaust contributions to PM levels in 5 EU cities. 39 th PMP Meeting 9-10 March 2016

Technology Options for the Cement Industry with the Use of Alternative Fuels

TECHNICAL DATASHEET. Weatherproof LED luminaire ZALEDA EVOL II. 85,000 h product life. General characteristics. Mounting accessories.

Test Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK

2014 FCA Canada Inc. Windsor Assembly Plant [ANNUAL PUBLIC REPORT UNDER O. REG. 455/09]

SAFETY DATA SHEET 1. PRODUCT AND COMPANY IDENTIFICATION 2. CHEMICAL HAZARD ID: 3. COMPOSITION INFORMATION A. Lithium-Ion Single Cell Matrix

Petrochemical standards

Supply of Services for Detailed OEB Crude Assay Analysis

Trough Valve. Technical Information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

1 Alloy specification of standard sacrificial anodes BOLT-ON ANODES / DISC ANODES

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet

3/15/2017. Oil Analysis: When the Oil Speaks, You Should Listen! Oil Analysis. Common Wear Metals Found in Oil. Common Wear Metals Found in Oil

Regional Laboratory, Indian Oil Corporation Limited, Korukkupet Terminal, Kathivakkam High Road, Chennai, Tamil Nadu

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

BORNEBUSCH. Non-ferrous metals. Stock list and material list for cast bronzes and other non-ferrous metals

European new pellets standards Case non-woody pellets, 4 May 2010, Lyon

Metallic Systems TYPE SPTC

CERTIFIED & TESTED TO ISO-22241

Transcription:

Last Amended on - Page 1 of 6 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Quality Monitoring Respirable Suspended Particulate Matter Less than 10µm or PM10 IS:5182 (Part 23):2006 5-1000 µg/m3 Respirable Suspended Particulate Matter (less than 2.5µm or PM 2.5) STH/SOP/5.4/1.5 (Issue Date 04-01-2013) 5-500 µg/m3 Sulphur Dioxide IS: 5182 (Part 2):2001 (RA:2012) 5-400 µg/m3 Nitrogen Dioxide IS: 5182 (Part 6):2006 (RA: 2012) 5-100 µg/m3 2. Stack Emission Monitoring Velocity & Volume of Gas discharge Particulate Matter Sulphur Dioxide Nitrogen Dioxide IS: 11255 (Part 3):2008 1.5 60 m/s IS: 11255 (Part 1):1985 (RA:2012) 5-1000 mg/nm3 IS: 11255 (Part 2):1985(RA: 2003) 5-100 mg/nm3 IS: 11255 (Part 7):2005(RA: 2012) 5-100 mg/nm3 3. Noise Level Monitoring Noise Level IS: 9989: 1981 35-130 db (A) II. WATER 1. Potable and Color IS: 3025(part 4)-1983 RA 2002 Clause 2.0 2 to 500 hazen units Temperature IS: 3025 (part9)-1984 RA 2002 Ambient to 60 C Turbidity, NTU IS: 3025 (part10)-1984 RA 2002 0.5 to 1000NTU ph value IS: 3025 (part11)-1983 RA 2002 1 to 10 Electrical conductivity IS: 3025 (part14)-1984 RA 2002 0.1 us/cm to 20mS/cm

Last Amended on - Page 2 of 6 Potable and Total dissolved solids IS: 3025 (part16)-1984 RA 2003 Edition 2.1 (2000 01) 10 to 5000mg/L Sulphate APHA, 4500 SO4-F, 22 nd edition 1 to 500 mg/l Phosphorous IS: 3025 (part31)-1988 RA 2003 clause 4.0 Residual free chlorine IS: 3025 (part26)-1988 RA 2003 Edition 2.1 (2000-02) clause 3.0 0.2 to 10 mg/l 1 to 50 mg/l Alkalinity as CaCO 3 IS: 3025(Part22)-1986 RA 2003 2 to 500 mg/l Acidity IS: 3025(Part23)-1986 RA 2003 1 to 500 mg/l Chloride IS: 3025 (part32)-1984 RA 2003 clause 2.0 2 to 500 mg/l Ammonical nitrogen IS: 3025 (part34)-1988 RA 2003 clause 2.5 Silica IS: 3025 (part35)-1988 RA 2003 clause 3.0 0.4 to 100 mg/l 0.2 to 1.3 mg/l Free ammonia IS: 3025 (part34)-1988 RA 2003 0.5 to 10 mg/l Oxygen dissolved IS: 3025 (part38)-1989 RA 2003 clause 4.0 Calcium (as Ca) IS: 3025 (part40)-1991 RA 2003 clause 5.0 Edition 2.1 (2004-02) Cadmium as Cd IS: 3025 (part41)-1992 RA 2003 clause 5.0 AAS Potassium as K IS: 3025 (part41)-1992 RA 2003 Editiion 2.1 Flame photometer 1 to 500 mg/l 0.05 to 0.1 mg/l 0.1 to 10mg/l

Last Amended on - Page 3 of 6 Potable and Sodium (as Na IS: 3025 (part45)-1993 RA 2003 Edition 2.1 ( 2003-04) Flam photo meter Magnesium (as Mg) IS: 3025 (part46)-1994 RA 2003 Lead (as Pb) IS: 3025 (part47)-1994 RA 2003 clause 7.0 Zinc (as Zn) IS: 3025 (part49)-1994 RA 2003 clause 6.0 Edition 2.1 ( 2009-10) 0. 1 to 2 mg/l 0.1 to 0.3 mg/l Carbonates and bicarbonates (as CaCO3) IS: 3025 (part51)-2001 clause 8.2 (a) by colour change 5 to 1000 mg/l Hexavalent chromium APHA, 3500 Cr, B, 22 nd edition 0.01 to 100 mgl Total chromium IS: 3025 (part52)-2003 clause 7.0 AAS 2 to 10 mg/l Iron (as Fe) IS: 3025 p(53) 2003 clause 6.0 UV method Nickel (as Ni) IS: 3025 (part 54)-2003 0.2 to 0.4 mg/l Aluminium (as Al) IS: 3025 (part 55)-2003 clause 5.0 eriochrome cyanine - UV method Total Hardness ( as CaCO3) IS: 3025 (part 21)-1983 RA 2002 Edition 2.1(20001) Copper (as Cu) IS: 3025 (part 42)-1992 RA 2003 clause 6.0 Edition 2.1 (2004-05) AAS 1 to 500 mg/l 0.05 to 100 mg/l

Last Amended on - Page 4 of 6 Potable and Manganese (as Mn) APHA, 3500 Mn, B, 22 nd edition 0.1 to 1.5 mg/l Fluoride (as F) APHA, 4500-F, 22 nd edition Spadns method 0.02 to 10 mg/l 2. Waste Water Color, IS: 3025(part 4)-1983 RA 2002 Clause 2.0 2 to 500 hazen units Temperature IS: 3025 (part9)-1984ra 2002 Ambient to 60 C Turbidity, NTU IS: 3025 (part10)-1984 RA 2002 0.5 to 1000NTU ph value IS: 3025 (part11)-1983 RA 2002 1 to 10 Electrical conductivity IS: 3025 (part14)-1984 RA 2002 0.1 us/cm to 20mS/cm Alkalinity as CaCO 3 IS: 3025(Part22)-1986 RA 2003 2 to 500 mg/l Acidity IS: 3025(Part23)-1986 RA 2003 1 to 500 mg/l Total dissolved solids IS: 3025 (part16)-1984 RA 2003 Edition 2.1 (2000 01) Total solids IS: 3025 (part 15)-1984 RA 2003 Edition 2.1 Total suspended solids IS: 3025(p-17)-1984 RA 2003 Edition 2.1(2000 01) 10 to 5000mg/L 1 to 500 mg/l 1-500mg/lt Total volatile solids IS: 3025 (part 18) 1984 1 to 500 mg/l Sulphate APHA, 4500 SO4-F, 22 nd edition 1 to 500 mg/l Residual free chlorine IS: 3025 (part26)-1986 RA 2003 Clause 3.0 Edition 2.1 (2000-02) Phosphorous IS: 3025 (part31)-1988 RA 2003 Clause 4.0 Under process 0.2 to 10 mg/l

Last Amended on - Page 5 of 6 Waste Water Chloride IS: 3025 (part32)-1984 RA 2003 2 to 500 mg/l Ammonical nitrogen IS: 3025 (part34)-1988 RA 2003 Clause 2.5 0.4 to 100 mg/l Free ammonia IS: 3025 (part34)-1988 RA 2003 0.5 to 10 mg/l Calcium (as Ca) IS: 3025 (part40)-1991 RA 2003 Clause 5.0 Edition 2.1 (2004-02) Cadmium as Cd IS: 3025 (part41)-1992 RA 2003 Clause 5.0 AAS Copper (as Cu) IS: 3025 (part42)-1992 RA 2003 Clause 6.0 Edition 2.1 ( 2004-05) AAS Potassium as K IS: 3025 (part45)-1993 RA 2003 Edition 2.1 Flame photo meter Sodium (as Na) IS: 3025 (part45)-1993 RA 2003 Edition 2.1 ( 2003-04) Flame photo meter Magnesium (as Mg) IS: 3025 (part46)-1994 RA 2003 Lead (as Pb) IS: 3025 (part47)-1994 RA 2003 Clause 7.0 Zinc (as Zn) IS 3025 (part49)-1994 RA 2003 Clause 6.0 Edition 2.1 ( 2009-10) 0.05 to 0.1 mg/l 0.01 to 0.2 mg/l 1 to 10 mg/l 0. 1 to 2 mg/l 0.1 to 0.3 mg/l

Last Amended on - Page 6 of 6 Waste Water Carbonates and bicarbonates (as CaCO3) IS: 3025 (part51)-2001 Clause 8.2 (a) by colour change 5 to 1000 mg/l Hexavalent chromium APHA, 3500 Cr, B, 22 nd edition 0.01 to 100 mgl Total chromium, IS: 3025 (part52)-2003 Clause 7.0 AAS 2 to 10 mg/l Iron (as Fe) IS: 3025/ p( 53) 2003 Clause 6.0 UV method Nickel (as Ni) IS: 3025 (part 54)-2003 0.2 to 0.4 mg/l Aluminium (as Al) IS: 3025 (part 55)-2003 Clause 5.0 Eriochrome cyanine UV method Manganese (as Mn) APHA, 3500 Mn, B, 22 nd edition 0.1 to 1.5mg/L Fluoride (as F) APHA, 4500-F, 22 nd edition Spandns method 0.02 to 10 mg/l Biochemical oxygen demand APHA, 5210, B, 22 nd edition 1 to 500 mg/l Chemical oxygen demand APHA, 5220, B, 22 nd edition 1 to 500 mg/l Oil & Grease IS: 3025 (part 39)-1991 RA 2003 Edition 2.1 (2004-05) -X-X-X-X-X-X-X-X-X-X-X-X-X-X-