TIX 402, TIX 802 & TIX 1602 Thru-Hull Light Lumishore SUPRA (dual colour) light Installation and Operating Guide

Similar documents
TIX402 EOS Installation and Operating Guide

TIX 802 & TIX 1602 Thru-Hull Light Lumishore EOS Full Colour Change light Installation and Operating Guide

THX 402, THX 802 & THX 1602 Thru-Hull Light Lumishore SUPRA (dual colour) light Installation and Operating Guide

SMX 22, SMX52 & SMX 102 Installation and Operating Guide

Single Colour Light. TIX202 Interchangeable Flush Fit Thru-Hull Light. Installation and Operation Guide. Rev

Single Colour Light. TIX301 Interchangeable Flush Fit Thru-Hull Light. Installation and Operation Guide

SMX 92 & SMX 152 Installation and Operating Guide

THX120-CCP. Colour-CHANGE Lights THX120-CCP Thru-Hull Installation and Operation Guide

Colour-CHANGE Lights THX72-CCP Thru-Hull and THX72-CCP-FF Flush Fit Installation and Operation Guide

Surface Mount e-lites

THX & TIX Lumi-Hub Installation Guide

Bluefin Led Underwater lights.

Bluefin Led Underwater lights.

SMX Lumi-Hub Installation Guide

All Bluefin Led lights are water tested so please be aware there may be moisture present on the light.

Bluefin Led Underwater lights.

SV10 LED. The US manufactured SV10 LED is. SV10 LED technical specifications

Bluefin Led Underwater lights.

Bluefin Led Underwater lights.

SV38-250w. SV38 technical specifications

SV14 technical specifications

UltraSystem Series II INSTALLATION MANUAL PARTNERED WITH

Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual

MotorScrubber MS2000S/M/L Instruction Manual

18 LED Thru-Hull SeaLite

OceanLED This installation manual covers the following products:

UltraSystem Series II INSTALLATION MANUAL

User s Manual. Automatic Switch-Mode Battery Charger

OceanLED This installation manual covers the following products:

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL

UL Ti MATE Range of underwater lights. (click on document required)

Anchormax Vertical Capstan

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

130-RGB+W. underwater lights limited TM. IPX8 Underwater RATED. CUTE on size BIG on light. GRP and WOOD. 20 meter + N.

Congratulations on your purchase of your new Ultra-SoniTec Antifouling System! Ultra-SoniTec Antifouling System! Ultra-SoniTec Advanced Ultrasonic

Congratulations. You ve just purchased the most advanced flasher available on the market today. This

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

LIGHTNING PLUS 120 WATT / 6 OUTLET VOLT POWER SUPPLY & STROBE LIGHT KIT 6 Different Light Patterns 8006 SERIES INSTALLATION INSTRUCTIONS

230VAC Power Inverter 400W Owner s Manual

SERVICE MANUAL. Koala

DURA-PANEL W OUTPUT: 12 VDC, 20 Watt W OUTPUT: 12 VDC, 50 Watt W OUTPUT: 12 VDC, 100 Watt

Operating Manual

WARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children.

Deluxe ASA Halogen Spot/Flood Light

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Effective June 1, 2013 This guide supersedes all previous versions

3PC TONNEAU COVER WITH SPORTS BAR INSTALLATION INSTRUCTIONS

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

TYPE 4 BEARING INSTALLATION IN COMPOSITE HULLS.

B&G Ultrasonic Speed Sensor. Installation and User Manual BGH

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

Sport Model with an easy-lube spindle

Operating Manual / / REV F

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Installation Service INSTRUCTIONS

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

START HERE FRONT BUMPER REMOVAL. 1) Turn off engine and chalk tires with stop block. Open Hood. Disconnect Battery.

PIL0478 ISSUE 01/ 07/16

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents:

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

LI-2B Installation Manual

MotorScrubber MS2000S/M/L Instruction Manual

Upper Class Grille Main grille INSERT - #54127 / #54131 / #54133 / #51127 / #51131 / 51133

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

EMF INSTALLATION & OWNER S MANUAL ULTRA COMPACT NICHE LIGHT FOR FIBREGLASS POOLS STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE

INSTRUCTION MANUAL. BatteryMINDer. Model SCC515 Maintenance Charger- Solar Controller for use with 5 Watt and 15 Watt Solar Panels

DC Master 24/ A

Spotlight 1,000,000 Power Series Cordless Rechargeable

Eclipse Solar Suitcase

Power Inverter 400 MW Owner s Manual

/ GMC SIERRA 2500 / 3500 START HERE BEFORE YOU BEGIN STEP 2

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

Quayworks Isuzu Marine Engine Control Panel Refresh Kits Product Code QWRK1

Portable Solar Panels MSK-90 MSK-135. Manual. Please read this manual before using your MSK-90 or MSK-135.

OWNER S MANUAL & WARRANTY INFORMATION

Installation Instructions

Speedometer log sensor

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

ENFORCER TM 6201-IQ ELECTRONIC SIREN

START HERE GRILLE REMOVAL. 1) Turn off engine and chalk tires with stop block. Open Hood. 1. Disconnect negative battery terminal.

Go Yonder D-Lite Owner s Manual

Installation and Operating Instructions (for chargers shown below)

USER INSTRUCTIONS STRIKER LED USER INSTRUCTIONS

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Lift N Go [Model 210] Electric Carrier For use with power chairs & scooters Installation Guide & Owners Manual

SAFETY RULES SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE OPERATING SAVE THESE INSTRUCTIONS

Single Lever Pull-Out Kitchen Faucet

3PC TONNEAU COVER INSTALLATION INSTRUCTIONS. Ford Ranger/Mazda BT-50 (without bedliner)

USER S MANUAL & WARRANTY INFORMATION

TORCH Main Grille Main grille INSERT - # / # Chevrolet Silverado

Installation Manual. For. Trident Boat Lifts

GEN 3 LED LIGHT BAR INSTALLATION MANUAL Model 7840-A 44"

OWNER S MANUAL & WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

The Traveler Series: Adventurer

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

LED Twister II. User manual UK Version 1.0

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

Transcription:

SUPRA Thru-Hull Integrated System TIX, TIX & TIX Thru-Hull Light Lumishore SUPRA (dual colour) light Installation and Operating Guide Congratulations! You have purchased a LUMISHORE advanced technology underwater light. Every care has been taken to ensure your Thru-Hull light arrives in perfect condition, so please enjoy the ultimate experience in underwater lighting. LUMISHORE Thru-Hull high intensity lights are designed for those owners who prefer the integrity of a thru-hull installation in a light that employs the most powerful, efficient and cost effective underwater LED lighting on the market today. The LUMISHORE Thru-Hull is suitable for many sizes and types of water-craft, including Sports Boats, Cruisers, Yachts and Super Yachts. LUMISHORE Thru-Hull LED lights come with a compact electronic driver module to ensure trouble free operation for years to come. Please read the following pages before attempting installation to ensure complete understanding of the LUMISHORE LED lights. BEFORE YOU START High Intensity LED light Do not stare into the LED module at close proximity. Always ensure that the vessel s power source and battery are disconnected or isolated prior to installation A qualified professional should carry out both the electrical and mechanical installation. If in doubt please contact LUMISHORE. refer to product support section Always use a suitable fuse or circuit breaker to protect the complete system. Each light to be individually fused. The Thru-Hull maybe installed into GRP (Glass Reinforced Plastic or Fibreglass) and wooden hulls. For metal hull or carbon fibre installations an isolation kit will be required. The light should be installed - (5-5mm) below the minimum load water line. For best results install the lights between.5ft (.m) and.5ft (m) apart. Never try to install or remove light with the vessel in the water. Lights should not be exposed to any temperatures in excess of 5 F (5 C). For example, next to hot engine components or where exhaust emissions could be expelled onto the light while underwater. Do not over tighten the retaining bolts. A force of 3Nm on each bolt should not be exceeded. All LUMISHORE products should have a bonding to the DC system via bonding strap for galvanic protection. Choose a location - The light must be installed onto a flat (not curved) surface. Mount on transom or side hull only. PLANNING THE INSTALLATION The TIX SUPRA lighting system will typically consist of several Lumishore TIX lights. These can be powered from a DC power source (e.g. battery), or an AC/DC power supply. The lights can be switched through their different lighting modes by quickly turning the power On and Off. To benefit from the full functionality of the lights simply install a Lumi-Switch. Follow the electrical diagrams on the following pages for a detailed guide. 5-53-REV-

Planning the Installation & Wiring Diagram The lights are very easy to install and operate. Follow the wiring diagram inside this guide The following components should be used; Fuse ( per light) Waterproof junction box Power Relay Switch or Lumi-Switch Power cable - See cable gauge guide for more information Switch cable - -Core (Min ) - -Core for Lumi-Switch The following tools will be required; Hand Drill Screwdriver (Cross head) Appropriate Sealant (e.g. 3M ) Cleaning rags Holesaw - Refer to holesaw size on page 9 Note : Below is a basic diagram of the installation. For a more detailed and in-depth diagram please refer to pages to 7. For Lumi-Switch installation see page Switch Off Fuse On Red (+VDC) Red (+VDC) Yellow (Data) Note: All Yellow wires should be terminated together Black (GND) MASTER Fuse Red Cable marker Battery When installing more than lights or if the switch cable is more than m in length, use a relay to switch the power - See connection examples on pages 5 & 7 Plan the cable routing and work out the cable lengths. Check the cable awg required in the tables on Page All connections need to be made waterproof or use a suitable junction box or waterproof connectors.

Cable Gauge Tables It is important to use the correct cable gauge for the installation. This can be spilt into two sections. First work out the gauge required from the power source to the junction box, second work out the minimum gauge needed from the junction box to the lights these tables are given on page. First, calculate the cable gauge required from the power source to the junction box. The method for doing this is:. Calculate the TOTAL CURRENT IN AMPS of the circuit. i.e. number of lights x max current at chosen voltage. Find circuit LENGTH IN FEET (or metres) along the left side of the chart. Note that the total length of the circuit is the ROUNDTRIP distance from power source (usually the battery) to the junction box and back. 3. Read off the cable gauge required for the TOTAL CURRENT for the circuit length. 3% VOLTAGE DROP Critical to ft ft 5 ft ft 5 ft 3 ft ft 5 ft ft 7 ft ft 9 ft ft ft ft 3 ft CURRENT F L O W IN AMP S 3 3 3 3 3 3 3 3 3 3 3

Cable Gauge Tables - Continued The light cable and power cable can be extended, however the correct cable gauge should be used. See the tables below The tables below give the minimum cable gauge required depending on the supply voltage, and distance from the power source to the lights. Please ensure that the correct cable gauge is used in the installation Note : The cable distance there and back has been taken into consideration in these calculations. Model TIX TIX TIX Gauge Length of Cable V ft Do Not Extend N/A V ft 3ft 3ft Fuse Table Model TIX TIX TIX V A 5A N/A Fuse Rating V 5.A 7.5A A to Metric conversion table Size Cross sectional Area Cable diameter mm².3mm².mm² 3.3mm² 5.mm².3mm² 3mm² mm².mm.3mm.mm.mm.5mm 3.mm.mm 5.mm 33mm².5mm Each light must be individually fused

Planning the Installation (TIX, & ) DO NOT attempt to unscrew or remove cartridge from light body. Doing so will invalidate warranty and potentially damage the LED module. Bonding Attention: Failure to bond the lights properly and maintain the appropriate protection will invalidate the LUMISHORE warranty. LUMISHORE lights should be connected to the vessel s DC Bonding system to ensure protection from electrolytic / galvanic corrosion. All bonding connections should be fully checked prior to returning the vessel to the water. LUMISHORE lights have integrated circuitry to protect lights from external issues, but these are dependent upon correct bonding. Installation into a metal or carbon fibre hull requires an isolation sleeve kit. Metal or Carbon Fibre Hull Isolation Kit Model TIX TIX TIX Part Number - - - Installation Considerations: Location - Positioning will be dependent on both external and internal obstacles; consideration should be given to installation wiring and internal access within the vessel. Ideally the light modules should be installed to (5-5mm) below the water line and spaced between.5ft to.5ft (.-m) apart. Select a flat surface, make sure that both the internal and external surfaces of the hull are even and parallel. It may be necessary to sand or grind the surface. A hole will be drilled to allow the Thru-Hull light to be inserted. Care must be taken to ensure there is unrestricted access inside the hull The light is temperature sensitive and must not be located close to the exhaust or other heat sources. If multiple lights are installed, each light should be evenly spaced to ensure the best water illumination. The number of lights and the spacing on your vessel will depend on a few factors: vessel size, location of lights and water clarity. Note : The system uses a master light to synchronise the system. Install only ONE master light per system. The cable will be labelled Master (just behind the light) and marked with a (Red) colour marker at the end of the cable. 5

TIX - Basic Dimensions Light Unit mm (3.7in) LED ARRAY SHOWN FOR ILLUSTRATION PURPOSES ONLY mm (5.7in) 3mm (5.35in) mm (.3in) 55mm (.7in)

TIX - Basic Dimensions Light Unit mm (.7in) LED ARRAY SHOWN FOR ILLUSTRATION PURPOSES ONLY 93mm (7.in) mm (7.in).5mm (.3in) mm (3.3in) 7

TIX - Basic Dimensions Light Unit mm (5.5in) LED ARRAY SHOWN FOR ILLUSTRATION PURPOSES ONLY 95mm (7.in) mm (7.in) mm (.3in) 9mm (3.5in)

Light Installation Tools Required 5mm Allen Wrench Drill/Driver Hole-saw Marine Sealant (Use only 3M ) Rags for clean-up. Measure the position of the lights on a flat part of the hull. Mark carefully, and double-check for internal obstacles.. Check the required hole size against the table below. Drill a perpendicular hole through the hull using an appropriate cutter for the hull material. Model TIX TIX TIX Hole Size 57mm (.5 ) mm (3.375 ) 9mm (3.5 ) Hole Size W/Delrin Sleeve 3mm (.375 ) 9mm (3.5 ) mm (3.9375 ) 3. The exposed inner hull surface must be properly sealed to prevent water intrusion into the hull before the Thru-Hull is secured in place.. Before inserting the Thru-Hull light ensure that the hull surface is free from dirt and grease and remove any existing anti-foul from the hull surface. Rear Side Apply sealant Note: Do not use an alcohol-based solvent as this may have an adverse effect on the sealant 5. Using an approved adhesive (3M Marine (recommended) or similar), apply liberally a continuous bead of sealant around the entire circumference of the sealant groove, on the base of the stem and on the shaft of the Thru-Hull.. Feed the connector and cable through the hole in the hull avoiding any strain on the cable. Gently insert the stem of the Thru-Hull light assembly through the hole in the hull. 7. Apply even pressure with a slight circular motion until the Thru-Hull is flush with the hull surface. Ensure the light is orientated correctly. See page for more information.. From inside the vessel, feed the supplied washer down the shaft of the Thru-Hull fitting. Screw the locking nut in place and tighten the retaining bolts so that they are hand tight (less than Nm) - Do not tighten fully at this stage, excess pressure will push all of the sealant out. 9. Remove excess sealant that is squeezed from behind the light with a rag.. Allow the sealant to cure according to the sealant manufacturer s instructions. Once fully cured, using a 5mm Allen wrench, re-tighten each retaining bolt (force less than 3Nm). Care should be taken not to exceed this force as damage to the light module or hull of the vessel may occur.. Attach the vessel s bonding protection to the bonding bolt on the locking ring. 9

Light Installation - Continued Ensure that each light module has correct vertical and horizontal alignment with the hull, and that the correct orientation of the light module is achieved (refer to the module below). Top A3 Front View Max Current Ratings Model Driver Type Max Current (V DC) Max Current (V DC) TIX DC A 3A TIX DC.A.A TIX DC N/A.5A Ensure correct electrical polarity. Incorrect installation will invalidate warranty!

System Operation - Switch Operation Installation with standard On/Off Switch Off On. On/Off Switch (customer supplied). If using a standard On/Off switch, to cycle through each mode simply and quickly switch the system Off and then On again to switch to the next mode (Refer to sequence diagram below). Installation with Lumi-Switch The Lumi-Switch has two operations on/off and momentary. The momentary function has a spring action, and is operated by pressing the Bottom of the switch. The function cycle advances in the following sequence, along with their momentary functions (in red): Standard On/Off switch functions (Outer ring only) WHITE N/A Additional features using Lumi-Switch CHANGE SPEED On/Off N/A BLUE CHANGE SPEED Mode BRIGHTNESS CONTROL COLOUR FADE Note: The TIX, & lights have built in memory. When they are switched on for more than 3 seconds the setting will be saved, meaning the lights will be at the same setting next time they are switched On. The underwater lighting system should always be tested before the boat goes back in the water. Check that each light comes on and all lights change in sequence as per the system operation section above. See the problem solving guide for advice on resolving any issues you may have. Once the boat is back in the water check for any water ingress around the installed lights. Check again after several hours. Water ingress should be dealt with immediately. The lights should be checked several times over the first hrs and periodically after that to ensure installation is satisfactory.

Maintenance & Product Support Testing the Lights The underwater lighting system should always be tested before the boat goes back in the water. Check that each light comes on, and all lights change in sequence as per the system operation section above. See the problem solving guide for advice on resolving any issues. Once the boat is back in the water, check for any water ingress on the installed lights. Any ingress should be dealt with immediately. The lights should be checked several times over the first -hours and periodically after that to ensure installation is satisfactory. Maintenance and Cleaning The locking nut and retaining bolts should be inspected on a regular basis to ensure they are kept tight. LUMISHORE recommends general inspection of the light module, driver and cable attachments every month. LUMISHORE lights require simple cleaning. Lights should be checked often to ensure the light body and lens area are free from sea growth. In the event that your light requires cleaning, we recommend the use of a soft cloth or soft bristled brush. The glass should be kept clean with a plastic scraper or soft brush. Regular cleaning of the lens will ensure that the light module delivers maximum optical output. DO NOT use an abrasive cloth or cleaning agent as permanent damage to the lens may occur. DO NOT use any abrasive cleaning materials as these may damage the body of the light. DO NOT use any cleaning fluids that contain solvents, acids or alkalis. DO NOT clean using pressure washing or sandblasting equipment. Slight discolouration of body may occur over life. This does not affect performance, and is not subject to warranty. Due to nature and high build quality it may on rare occasions be possible to see small levels of condensation, this is normal for high power LEDs and will disappear after cooling and does not harm operation in any way. No chemicals, cleaners, chemical sprays or sandblasting should ever be applied / used on lights this will negate warranty To prolong device lifetime and prevent marine growth build up, a good quality anti-fouling system must be used to coat the external body of the device. This should be renewed regularly. Product Support If you have questions or comments, please e-mail info@lumishore.com or call USA (9) 5-33, United Kingdom +() 9, or France +33()93 5 537.

Warranty & Troubleshooting Warranty LUMISHORE Ltd warrants the Thru-Hull lighting system to be free from defects in workmanship for a period of three years, starting from the date of original purchase. Should your lighting system have a problem during this period, please contact your dealer as soon as you become aware of the defect. Misuse, abuse, improper installation, neglect, improper shipping, damage caused by disasters (e.g. fire, flood and lightning), installation by unqualified personnel, unauthorized repair or modification will void this warranty. For the avoidance of confusion and doubt, non compliance with all installation, maintenance and operating instructions in this document constitute non conformance with warranty terms. Full warranty details are available at www.lumishore.com. Troubleshooting In the event of one or more of the lights not lighting up then check the LED status on the driver (at the back of the light). The LED will either be continually ON (healthy), OFF (no power to driver) or flashing. Please refer to the table below for what the number of flashes means and what action to take. LED Status No LED light on driver Solid LED Flashing times Flashing 3 times Flashing times Flashing 7 times Flashing times Continuous rapid flashing Meaning No power to driver Power On Low input voltage to driver Light temp too high Driver temp too high LED array voltage out of range Light not detected Driver program corrupt Action to take / Things to check Check fuse / breaker Check connections Check voltage at input to driver connections Driver is receiving voltage and operating properly Check the switch is operating correctly Check power connections or battery voltage Could happen when light is out of water or next to exhaust Driver is mounted too close to an engine or exhaust Check the connections between light and driver Check light in each colour to determine if all colours are working Light is not connected or cable is cut or pinched Light has been connected incorrectly to the driver Reset driver by switching off power for minute, and then switching on again Contact LUMISHORE if problem persists In the event of an issue, record the serial number(s) of the light(s) and contact your local dealer. If a light does not switch on, or function normally, it should be disconnected from the power source Thank you! For purchasing LUMISHORE lights 3

Wiring Diagram - On/Off Switch - Up to Lights Battery Core Power cable keep as short as possible If extended consult cable gauge guide (Page 3) Distribution Panel IP Rated junction box (Not included) For cable extension Info See Page Lumi-Hub or Junction Box FOR WIRING INFORMATION PLEASE SEE PAGE 5 -Core cable (min - length as required) Only one master light should be installed per light system MASTER Off On Customer supplied Switch, On/Off control only Wire Colour Code Red +VDC Black GND Yellow Data The Lumi-Hub comes with all connections, fuses and relay installed. Simplify your installation and reduce cost & time with a LUMISHORE Lumi-Hub

Junction Box Diagram - On/Off Switch Power Cable All DATA (Yellow) Wires here Data GND +VDC All GND (Black) Wires here Data Relay +VDC (Red) Wires from Lights here GND +VDC Switch Cable fuse Light fuse Light Data -Core cable fuse 3 In-line fuse holders (See fuse table on page for more info) GND Light 3 +VDC Note: For a system with more than lights, or for cable runs over m a marine grade Relay should be installed. Check the voltage rating is suitable for your Vessel (/V). The power requirement will depend on model and number of lights installed per relay. Consult table on page for Amp rating of each light 5

Wiring Diagram - Lumi-Switch - Up to Lights Battery Core Power cable keep as short as possible If extended consult cable gauge guide (Page 3) Distribution Panel Wire Colour Code Red +VDC Black GND Yellow Data IP Rated junction box (Not included) For cable extension Info See Page Lumi-Hub or Junction Box FOR WIRING INFORMATION PLEASE SEE PAGE 7 -Core cable (length as required) Only one master light should be installed per light system MASTER Lumi-Switch Connections On On MOMENTARY Lumi-Switch - Lumishore supplied Smart Switch. On/Off and mode control in one switch YELLOW RED Mode Mode BLUE GREEN POWER Back of Switch Note: Only one master light should be installed per light system

Junction Box Diagram - Lumi-Switch Power Cable All DATA (Yellow) Wires here Data GND +VDC All GND (Black) Wires here Data Relay +VDC (Red) Wires from Lights here GND +VDC Switch Cable fuse Light fuse Light Data -Core Lumi-Switch cable fuse 3 In-line fuse holders (See fuse table on page for more info) GND Light 3 +VDC Note: For a system with more than lights, or for cable runs over m a marine grade Relay should be installed. Check the voltage rating is suitable for your Vessel (/V). The power requirement will depend on model and number of lights installed per relay. Consult table on page for Amp rating of each light The Lumi-Hub comes with all connections, fuses and relay installed. Simplify your installation and reduce cost & time with a LUMISHORE Lumi-Hub 7