Oil/Air Cooler Units

Similar documents
Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION

Coolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications

Oil/air cooler BLK. Fluidcontrol

Air Cooler Mobile OK-ELD 0-6 with DC motor

Feed Pumps VP / VPB / VPBM

Oil/air cooler BLK. Fluidcontrol

GMP-Type. Key Features: Integrated Motor-Pump Units

Vane pumps, direct controlled Type PV7...A

Cooling Systems Air Cooled / Liquid Cooled

Coolers. Air Cooled / Liquid Cooled

Feed Pumps Direct Drive Series 1.1.

Oil/air coolers. Table of contents. Features. Possible applications. RE 50111/12.06 Replaces: Types KOL and KOLP

Clamping and drive module

Feed Pumps Direct Drive Series 1.1.

Off-line filter / cooler unit BKF

Off-line filter / cooler unit FGSL

Oil/air cooler BLK ATEX-3GD

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Proportional Throttle Valves Series TDL

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

A-L O C COOLING SYSTEM OLAER COOLERS. Olaer A-LOC with integrated circulation pump for industrial hydraulic systems

Modular Explosion Proof Brakes. IECLine rev 0

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

Sectional Directional Control Valve RS 220

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Heat Exchangers. Evaporator Catalogue

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CM10-3 A-R-A-E-AVBE F-A-A-N

BYPASS SERIES GLOBAL STANDARD COOLER

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Backflushing Filter AutoFilt RF3

Directional Control Valve Series D1VW

Electric machine, permanent magnet internal

Fixed Displacement Bent Axis Axial Piston Motors TMB 700

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Bell Housings with Rigid / Flexible Pump Mounting PTS / PT

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

Off-Line Filter BNF. FluidControl

J1000 D E F I 1000 J1000 J1000 J1000 J1000

MBS 1200 and MBS 1250

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.

Proportional Pressure Reducing Valve PDM08130

Table of contents. Three-phase asynchronous motors DA

BPF. Centrifugal Plug Fans

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

Pressure Relief Valve DB12 CE

Relative and absolute pressure transmitter type 528

Circulation pumps BFP-ATEX-T3/T4

water-cooled motor / generator with up to 13 kw continuous power

Drive module. Table of contents. Features. Applications. RE 51145/06.12 Replaces: Type UPE 5

GLOBAL STANDARD COOLER

Directional Control Valve

Proportional Flow-Control Cartridges, Size 5

ELD Series - DC Motor Drive

Pressure Transmitters

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type DRE05SK

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Oil/Air Cooler Units Standard series - Accessories

General Specifications. Cooling Method 3M series are IC 411 Standard. IC 416, IC 418 can be provided Upon request

Directional Control Valve Series D3W Soft Shift

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

CM5-11 A-R-G-E-AQQE F-A-A-N

Model Number Structure

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Versatile and Powerful. Liduro Wind Frequency Converter System

VEP03MSV-PDRP CONTINENTAL HYDRAULICS 3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

OFFLINE SERIES GLOBAL STANDARD COOLER

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

MVSI. Technical features

CM5-5 A-R-A-E-AVBE F-A-A-N

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

ELD Series - DC Motor Drive

Company name: Created by: Phone:

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

Transcription:

COMPLETE OIL / AIR COOLER SYSTEM WITH AXIAL FAN FOR INDUSTRIAL APPLICATIONS. General description In hydraulic systems energy is transformed and transmitted. During this process, efficiency losses occur, i.e. mechanical and hydraulic energy is converted into heat. It is the purpose of the cooler to dissipate this heat and to maintain the thermal balance of the hydraulic fluid. Oil/Air Cooler Units Motoinverter Series EL MI Type Application These high performance coolers equipped with axial fans and motoinverter are suitable for hydraulic cooling applications, with both return line and off line versions available. Typical applications include: industrial power units, lubrication systems (i.e. gearboxes) and machine tools. OK-EL MI Product Features Controlled Cooling Power Constant Output Oil Temperature 16 Bar Dynamic Pressure Rating OK-EL MI coolers use high efficiency axial fans driven by motoinverter and sturdy aluminium bar-and-plate cooling elements. This guarantees immediate adjustment to required cooling performance under changing load conditions and superior cooler durability. Cooling power, as a function of fan speed, is controlled depending on the required oil outlet temperature. The main advantage of this cooler/ motoinverter product line is the integration of oil temperature control via proportional fan speed into one very compact design. Further advantages are a lower noise level and lower power consumption over the term of a year.

MAIN FEATURES AND CHARACTERISTICS FEATURES AND ADVANTAGES DESCRIPTION CUSTOMER BENEFITS The motoinverter cooler needs only one power Reduced engineering and installation costs supply to run Compact assembled configuration with No additional cost for components and their integrated temperature thermistor in the installation like: temperature thermistor, signal cooling element and directly connected to the Plug and Play converter, control devices, wiring and terminals inverter Embedded motor speed control One motor type able to cover values up to 1800 RPM Flexibility whenever a higher RPM is needed Reduced engineering for motor speed control No additional engineering if heat to dissipate increases (within max performances of the motoinverter cooler) Low operational cost Published performance data @ nominal RPM related to a cooler in the same size without No need for a second or a larger cooler motoinverter, allows an increase by 20% Lower average noise level Noise level depending on the fan speed, corresponding to the required cooling power Lower noise level for the most time of the year The inverter controls the fan speed in order to have the oil temperature as constant as Constant oil temperature at different ambient temperature allows an optimal cooling possible performance Variable fan speed Energy absorption by the cooling system Power consumption costs are related to real during the year is highly influenced from the need cooling power season Motor power supply The electrical motor is not directly connected The inverter allows a controlled and stable to the main power supply which can be power supply for the motor (PWM) disturbed and not regulated NTC temperature sensor One component for temperature measuring Fast to replace Cartridge holder To simplify service and maintenance work, NTC temperature sensor are fixed in cartridge holders; which allows a replacement without the need to empty the cooling circuit. Easy maintenance Inverter parameters Customised and adapted to the cooling system The inverter parameters are set according to the customer cooling system The inverter parameters can be changed on site Oil/coling system Less stress for oil and cooling system due to less temperature fluctuations Oil temperature regulation due to the integrated system 2

COOLER MAIN COMPONETS OK-EL10MI OK-EL12MI -EL14MI Complete Oil/Air cooler unit consist of (1) metal housing, (2) motoinverter, (3) axial fan and (4) heat exchanger. The oil connections are external. OK-EL8MI -EL10MI OK-EL12MI -EL14MI 3

COOLING CAPACITY Depending on oil flow and the temperature differential delta-t between oil inlet and air inlet temperature. For cooling capacity with very low delta-t (i.e. < 10 C), please contact our technical support staff. COOLER SELECTION Designation: P V = Power loss [kw] P 01 = Specific cooling capacity [kw/ C] V = Tank volume [l] Ρ oil = Oil density [kg/l] for mineral oil 0.915 kg/l C oil = Spec. heat capacity [kj/kg C] for mineral oil 1.88 kj/kg C ΔT = Temperature increase in the system [ C] t = Operating time [min] T 1 = Desire oil temperature [ C] T 3 = Ambient temperature [ C] Example 1: Measuring the power loss on existing units and machinery. For this method the temperature increase of the oil is measured over certain period of time. The power loss can be calculated from the temperature increase Parameters: The oil temperature increases from 20 C to 60 C over 16 minutes. The tank contains 400l. Heat to dissipate: T Coil oil V PV [kw] t 60 40 1.88 0.915 400 PV 28.7 [kw] 16 60 Cooler selection: Desired oil temperature: 60 C Ambient temperature (air): 30 C PV P01 [kw/ C] T1 T3 28.7 P01 0.96 [kw/ C] 60 30 A 10% safety margin is recommended to allow for element contamination and therefore the specific power is: P 01 1.1 1.06 [kw/ C] The power loss 1.06 kw/ C must be dissipated by an oil cooler. Suggestion: At dt40 C => PV = 42.4kW Cooler OK-EL8MI P = 42.4kW at 120l/min and 1200RPM Cooler OK-EL10MI P = 42.4kW at 60l/min and 750RPM TECHNICAL DETAILS TABLE OF TECHNICAL SPECIFICATIONS, SIZE 8 TO 14 Type of cooler Type of temperature sensor Ambient temperature range [ C] OK-EL8MI NTC -20 +40 OK-EL10MI NTC -20 +40 OK-EL12MI OK-EL14MI 2x NTC 2x NTC -20 +40-20 +40 Oil flow [l/min] at max. operating pressure N of poles[-]/size[-] for the fan motor Motoinverter capacity [kw] @ 50Hz Noise level [db(a)] (at 1m distance) @ 1000 RPM Max. operating pressure [bar] Max. oil temperature [ C] Max. motor speed [RPM] Max. viscosity [mm2/s] continuous working *300 4/100 2.2 77 16 130 1720 2000 65 *330 4/100 2.2 78 16 130 1430 2000 145 *660 (2 cooling elements) *660 (2 cooling elements) 4/100 (2 motors) 6/112 (2 motors) 2.2 (2 mot.) 2.2 (2 mot.) Weight [kg] 83 16 130 1430 2000 300 88 16 130 1200 2000 360 * :max oil flow 1. For direction of fan rotation, please refer to arrow on cooler housing. 2. Electric fan drive: axial drive with forward flow through cooler element (sucking). 3. Cooling fluid: mineral oil to DIN 51524; for other fluids, please contact our sales/ technical department. 4. Three-phase motoinverter IP55, conforming to CE norm. 5. Published noise levels can only be used as guidance, as acoustic properties vary and depend on the characteristics of room, connections, viscosity and resonance. Warning! When operating a cooler in conditions where the difference in temperature between ambient air and inlet oil exceeds 50 Celsius [C], care must be taken to avoid cycling of the fan at full speed/air flow. This can cause a rapid change in material temperature of the cooling element and may result in a significant reduction of the cooler lifetime or direct damage to the cooling element through thermal stress. Please contact your HYDAC branch or distributor for speed control solutions. NTC TEMPERATURE SENSOR In our case the NTC temperature sensor (called also thermal resistor or thermistor) is an electronic component that exhibits a large change in resistance with a change in body temperature. Made of ceramic semiconductor and has a large negative temperature coefficient of resistance (NTC devices). NTC MAIN TECHNICAL CHARACTERISTICS: Technical characteristic Working range (NTC) -20 +120 C * ) Specific temperature at 25 C 10kΩ Measure accuracy 1% Protection degree IP67 Temperature inertia 10K in liquid at 2m/s Cartridge holder Example 2: The power loss can also be estimated. With unrestricted flow approx. 15 to 20% of the drive power. With restricted flow up to 30% of the drive power. * ) to achieve best accuracy 4

MOTOINVERTER MAIN DATA Motor Type 3 phase single winding with 3 phase frequency inverter on board Pole nr. 4 or 6 UIN nom 3x 400V ±15% fin range 40 70 Hz P nom 2.2 kw @ 50Hz Protection degree (IP) 55 Isolation class F Service type S1 Mounting IMB14 D160 Frame Iec 100 (4pole) / 112 (6pole) MOTOINVERTER BLOC DIAGRAM Temp sensor R S T GND AC inverter L1 L2 L3 AC M 3ph motor MOTOINVERTER FREQUENCY REGULATION f [Hz] f max Coolling range P 2 Description P 1 Cooler switch ON point (Tmin, fmin ) P 2 Cooler max speed (Tmax, fmax ) P 3 Cooler switch OFF point (Tmin-Hoff, fmin ) f min H off P 3 P 1 T min -H off T min T max T [ C] Param. to set T min T max f min f max H off Description Oil temperature => cooler ON Oil temperature @ motor max. speed Min motor frequency => cooler ON Max motor frequency Temperature offset between cooler switch ON - OFF NOTE The inverter parameters are set according to the customer requirements before cooler dispatch. For on site parameters modification HYDAC SA, Switzerland is at your disposal. 5

PERFORMANCE DIAGRAMS Cooling capacity depends on oil flow and the temperature differential ΔT between the oil inlet and air inlet. For calculation of cooling capacity with very low ΔT values (i.e. < 10 C), please contact our technical support staff for help. Tolerance: +/- 8% OK-EL8MI 70 Heat dissipation at dt=40 C [kw] 60 50 40 30 20 10 250 l/min 180 l/min 120 l/min 90 l/min 30 l/min 0 400 600 800 1000 1200 1400 1600 1800 Noise level db(a) 60.6 76.8 85.8 86.8 @1 meter Limit of OK-EL8S Values measured at ΔT=40 C, may vary at lower ΔT values. OK-EL10MI 120 Heat dissipation at dt=40 C [kw] 100 80 60 40 300 l/min 180 l/min 150 l/min 120 l/min 60 l/min 20 0 400 600 800 1000 1200 1400 1600 Noise level db(a) 63.9 70.8 78.4 88.8 @1 meter Limit of OK-EL10L Values measured at ΔT=40 C, may vary at lower ΔT values. Published noise levels can only be used as guidance, as acoustic properties vary and depend on the characteristics of room, connections, viscosity and resonance. 6

OK-EL12MI 250 Heat dissipation at dt=40 C [kw] 200 150 100 50 600 l/min 360 l/min 300 l/min 240 l/min 120 l/min 0 400 600 800 1000 1200 1400 1600 Noise level db(a) 68.9 75.8 83.4 93.7 @1 meter Limit of OK-EL12S Values measured at ΔT=40 C, may vary at lower ΔT values. OK-EL14MI Heat dissipation at dt=40 C [kw] 240 220 200 180 160 140 120 100 80 600 l/min 360 l/min 300 l/min 240 l/min 120 l/min 60 400 700 1000 1300 Noise level db(a) 63 73 88 98 @1 meter Limit of OK-EL14L Values measured at ΔT=40 C, may vary at lower ΔT values. Published noise levels can only be used as guidance, as acoustic properties vary and depend on the characteristics of room, connections, viscosity and resonance. 7

PRESSURE DROP CURVES Differential pressure Δp measured at 30 mm²/s using mineral oil 3.00 EL14MI Pressure Drop @ 30 mm²/s [bar] 2.50 2.00 1.50 1.00 EL8MI EL10MI EL12MI 0.50 0.00 0.00 100.00 200.00 300.00 400.00 500.00 600.00 700.00 Oil flow [l/min] Correction factor K for other viscosities: Viscosity (mm²/s) 10 15 22 30 46 68 100 150 Factor K 0.35 0.5 0.75 1 1.4 1.9 2.5 3.5 MODEL TYPE (also order example) OK-EL 8MI / 3.1 / M / 1 Type of cooler OK-EL = Oil/Air cooler Size / motor max speed 8MI = 1800 min-1 10MI = 1500 min-1 12MI = 1500 min-1 14MI = 1200 min-1 Type code and modification number: for current levels of each type of cooler, see table on the internet site Fluids M = Mineral oil to DIN 51524 Other fluids upon request Paint 1 = RAL 5009 (Standard) Other paint available upon request Motor power supply Standard voltages and frequencies for 3 phase motor Input voltage range 400VAC ± 15% Input frequency range 50Hz -20% / +40% 8

DIMENSIONS OK-EL8MI OK-EL12MI and 14MI Plug OK-EL10MI Plug A1 B C1 D1 D2 D3 E1 E2 E3 F S1 W1 * W2 * Z1 Z3 ±10 ±25 ±10 ±2 ±2 ±2 ±5 ±5 ±5 Ø/Slot Min. Min. OK-EL8MI 726 634 706 410 560 450 630 58 74 9x20 > 100 1200 600 G1 ¼ M22x1.5 OK-EL10MI 1030 767 930 750 700 790 910 75 116 12 > 100 2800 900 G1 ½ M22x1.5 OK-EL12MI 2130 735 1000 750 760 800 910 1080 30x13 > 100 3000 1000 G1 ½ M22x1.5 OK-EL14MI 2300 735 1150 750 900 800 910 1164 30x13 > 100 3000 1000 G1 ½ M22x1.5 * : for smaller distances, please contact our technical office CERTIFICATION FOLLOWING EN 1048 HYDAC SA design and manufacture high quality coolers that are tested on certified test stands to give reliable and repeatable high performance. To ensure the performance is accurate, testing in compliance with a recognized international test standard is the best solution. For air/liquid coolers this is EN1048. HYDAC SA test procedure complies with the requirements of EN 1048 and both the procedure and test equipment are independently inspected and certified by TÜV SÜD. The cooler performance details in this brochure have been tested following EN 1048. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 9