With regards to safety it is not necessary to check for correct operation.

Similar documents
II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions

1. General warnings Applicable regulation. EN ISO : 2005: Safety of machinery

HLAS SINGLE ACTING HYDRAULIC LINEAR ACTUATOR INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ACCUTRAK ROTARY MODELS 1040/9358/2004/9044/9468/5004/5044/2007/9479/5050 INSTALLATION AND OPERATIONS MANUAL

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

LIMIT SWITCH Axiom - AX

Temperature Sensor Series

LIMIT SWITCH Axiom - AX

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

LIMIT SWITCH Axiom - AX

Easytork Solenoid Valve IOM

Explosionproof NEC. Features

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING ON/OFF/REGULATING NAMUR SOLENOID VALVE MODEL 30318, 30318LW

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 2/2 INTERNAL PILOT PISTON TYPE SOLENOID VALVE MODEL 3370 (NORMALLY CLOSED)

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Type 2000 Transducer Product Instructions

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 5/2 INTERNAL PILOT OPERATED INLINE SINGLE SOLENOID POPPET VALVE MODEL L5006

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING, NORMALLY OPEN, SOLENOID VALVE MODEL 30211

Operating Instructions

Quantum Rotary Control Monitors Weatherproof IEC

TECHNICAL DATA 1-1/2 (dn40)

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 2/2 SOLENOID VALVE MODEL 20101, P2003, M2003,I2001

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Pneumatic Positioner RTX - Series USER S MANUAL. ROTEX P/P Ver. 0.1 Dated: MAY / 2009 REV 01: SEP/2010 Page 1 of 16

Pressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING, UNIVERSAL TYPENUAL RESET SOLENOID VALVE MODEL M3007

All details within this manual and the catalogue are subject to change without manner.

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

Quarter Master Chief Series 92 Actuator

Pneumatic Actuator Accessories. Discrete, NEMA 4, Four-Way Air/Air Suffix A2 (For PAD3 & PKD2 actuators)

OCTOPUS SELECTION & INSTALLATION GUIDE

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 5/2 INTERNAL PILOT OPERATED, POPPET TYPE SINGLE SOLENOID VALVE MODEL 51440NP

SynergEX Panelboards for Hazardous Locations

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation and Operating Manual

t EVAPORATOR PRESSURE REGULATING VALVES

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

CIRCLE SEAL CONTROLS

Control & Power, Inc

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Introduction. Installation. Maintenance. Bill of Materials

TECHNICAL DATA. Q= C v P S

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 INTERNAL PILOT OPERATED MODEL L3012 (NORMALLY CLOSED LATCH TYPE)

MS Application. Features. Proportional Valve Actuator General Instructions

CENTAC Inlet and Bypass Valve Positioners

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Non-incendive, explosionproof - NEC

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

VALIADIS S.A. HELLENIC MOTORS

Pressure Sensor No Series

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

SANITARY VALVE POSITION AND CONTROL MONITORS NON-INCENDIVE, EXPLOSIONPROOF - NEC

Technical Data. Dimensions

PMV P36C AND P41C POSITIONERS ACTUATORS

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

Operating Instructions

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

B21 Series BASOTROL Gas Valve

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

VG7000 Valve Linkage for M100 Series Motor Actuators

Shock/Vibration Control Switches

CIRCLE SEAL CONTROLS

ECON Limit Switch Box Fig

LIMIT SWITCH Prism - PI

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

200 Series Flow Meters

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

radius Series A pneumatic rack & pinion actuators

radius Series A pneumatic rack & pinion actuators

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

B Temperature Switches

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Pneumatic Division North America Richland, MI 49083

P70, P72, and P170 Series Controls for High Pressure Applications

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Maintenance & Repair Manual

Installation. Installation. 12. System Diagram... 10

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

MA-5200 Series MA-5300 Series

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

P70, P72, and P170 Controls for Low Pressure Applications

General purpose / hazardous area

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Fisher 657 Diaphragm Actuator Sizes and 87

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

Transcription:

- ATEX certified GC Ex na with Mag-Pac module SIRA 08 ATEX 4278X Ex na IIC T3 Gc II 3 G The equipment may be used in a CAT 3 environment in the presents of flammable gases and vapours only. The apparatus groups cover IIA, IIB and IIC with temperature classes of T1, T2 and T3 with an ambient temperature range -20 to +70 C. This document details an identical build that can be sold in different locations of the world. For this reason the product has two series numbers as indicated below: Series 3800 Series 789 The valve control monitor provides three methods of end of travel indication by the means of two sealed bifurcated integral switches and input circuit LED s which are located in the Mag-Pac module and an external visual indicator (if fitted). The enclosure comprises of a two parts, a cover and housing. This series is available in two enclosure materials, aluminium and 316 stainless steel. The Mag-Pac module is located within the enclosure along with the solenoid coil. The housing can offer up to two of the following conduit entries; M20 x 1.5p, M25 x 1.5p, ½ -14 NPT or ¾ -14 NPT cable entries for connection to an external power source via appropriate certified cable glands. Note: before installation of this product, please ensure that the product and its certification is suitable for the intended application. This product uses medium Nitrile s and an Eastar Copolyester visual indicator - if fitted. If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection provided by the equipment is not compromised. The unit has an ingress protection of IP66/67 and therefore any conduit device fitted must maintain this. Note: these products are not intended to be assembled directly to process pipe work etc that is heated or cooled to temperatures outside of the range as indicated above. With regards to safety it is not necessary to check for correct operation. Do not open when energized or following site procedures, ensure that the local surroundings is free of explosive atmosphere. Electrostatic hazard, clean only with damp cloth. Ensure that this product is not located in areas, when is use, where propagating brush discharge can occur such as near door ways, fans or fast moving air flow. The certification is compliant against the following standards EN 60079-0:2006 Electrical apparatus for explosive gas atmospheres - Part 0 - General requirements EN 60079-15:2005 Electrical apparatus for explosive gas atmospheres - Construction, test and marking of type of protection 'n' electrical apparatus www.westlockcontrols.com -EN 16/04 Page 1 of 9

1 Mounting instructions 1.1 Attach the mounting bracket and adaptor (if required) to the Quantum housing and shaft with the fasteners provided with the mounting kit. 1.2 To ensure that the Quantum is mounted correctly, it may necessary to stroke the actuator to the fully closed position. Before stroking the actuator to either end position, please ensure that the process is safe to do so. 1.3 With the actuator in the correct position, attach the Quantum / bracket to the actuator using the hardware provided in the mounting kit. 1.4 To release the cover, loosen the cover retaining screws. Twist the cover approx 45 and lift up. See Figure 1. 1.5 To set switches, lift the bottom cam and turn until the switch has activated (LED lit) and then release. The spring will push the cam back onto the splined shaft. Before stroking the actuator, please ensure that the process is safe to do so and that all hands are kept away from the moving shaft. 1.6 Stroke the actuator to the opposite end of travel. Set the top cam by pushing down and turning the cam until the switch is activated. Before stroking the actuator, please ensure that the process is safe to do so and that all hands are kept away from the moving shaft. 1.7 Stroke the actuator from one end of stroke to the other several times to check the switch operation. If the switches require adjustment, repeat steps 1.5 to 1.7. See Figure 2. Figure 1 Figure 2 Top cam push down, turn and release Bottom cam lift up, turn and release Page 2 of 9

2 Field wiring and installation Top view UP PER LOWER MAGPAC IN1 IN2 OUT1 OUT2 Lower limit switch Upper limit switch IN 2 IN 1 Side view J1 1 2 3 4 J2 J3 1 2 3 4 1 2 3 4 Upper limit switch Upper limit switch Solenoid 2 Output - Solenoid 2 Output + Solenoid 1 Output - Solenoid 1 Output + Solenoid 2 Intput - Solenoid 2 Intput + Solenoid 1 Intput - Solenoid 1 Intput + Lower limit switch Lower limit switch Before electrical installation, please read and follow the wiring diagram located inside the cover. The electrical ratings can be found on the product I.D label. Note: the valve monitors shall be connected to a device which prevents supply voltage transients in excess of 40% occurring at the apparatus power supply. The Mag-Pac has high reliability hermetically sealed bifurcated switches with LED indication for open and closed limits and indication of which solenoid is being operated. Contact Rated voltage (J1) (input switches) Rated current (J1) (input switches) Minimum Maximum Voltage drop max. Operating time Releasing time Operating temp Coil input voltage (J2 and J3) (2) Normally open 12-24 VDC (polarity insensitive) 2 ma to light LED Max. 500 ma 5 VAC / VDC 4 ms or less 2 ms or less -40 C - +85 C 24 VDC - 0.5 W 2.1 Field wiring must be carried out in accordance with site, local and national electrical codes / requirements. This includes special attention to earth bond to the Aluminium enclosure using the internal and external earth points provided. 2.2 Installation of this product shall be carried out by competent personnel in accordance with the applicable code of practice such as EN 60079-14. Attention Each Mag-Pac connector screw that has been used must be sealed with an RTV type sealant to maintain reliable screw contact pressure. Page 3 of 9

2.3 The position monitor housing can offer up to three of the following conduit entries: M20 x 1.5p, M25 x 1.5p, ½ -14 NPT, ¾ -14 NPT or Pg 13.5. These entries are detailed on the product I.D label found on the product cover. Please see Figure 3 for conduit positions. 2.4 The certification applies to equipment without cable glands. When mounting the enclosure in the hazardous area, only suitably ATEX Ex e certified glands must be used maintaining IP66/67. 2.5 All unused cable entries must be plugged with a suitably rated IP66/67 blanking devices. 2.6 Westlock nomenclature - Series 3800 The first two digits of this nomenclature signifies the series with the third digit defining whether the product has a visual beacon or not. The table below details the applicable ambient ranges: Series code Cover type 384* Beacon 386* Flat Westlock nomenclature - Series 789 These unitsare available in aluminium and stainless steel. Please contact the sales office for the part number P code suffix that is applied to the end of the 789 catalog code which, details aluminium or stainless steel. 01200 = aluminium enclosure only and 00124 = stainless steel enclosure only. Please note that if any other special build is included, then these suffix numbers will change. 2.7 Tighten the cover retaining screws hand tight using a standard size Allen key / screw driver as indicated below: 3800 series uses a 4 mm A/F Allen key 789 series uses either a 4 mm A/F Allen key or a correctly sized flat blade screwdriver. 3 Product repair and service 3.1 Inspection of this product shall be carried out by periodically by suitably trained personnel in accordance with the applicable code of practice such as EN 60079-17 to ensure that it is maintained in a satisfactory condition. 3.2 The equipment is not intended to be repaired by the user. The repair of this equipment is to be carried out by the manufacturer, or their approved agents, in accordance with the applicable code of practice such as EN 60079-19. 3.3 The equipment contains no other customer replaceable parts. 3.4 The certification of this product has been approved based on the material of construction as per the drawings listed in the schedule within this certificate. Any replacement parts that are notvmade in accordance to the listed drawing will invalidate the approval / certification. 3.5 Replacement parts must be purchased through Westlock Controls or via an approved Westlock Controls distributor. Figure 3 Conduit B Solenoid Conduit A Coil Page 4 of 9

4 Operating and maintenance instructions for Falcon and Falcon II solenoid valve 4.1 General description 4.1.1 The Falcon and Falcon II solenoid valve incorporates elastomer static seals through which a shaped spool moves and are manufactured for 3/2 or 5/2 way operation. 3/2 way is normally used for pilot control of the other relay valves or for the operation of single acting cylinders. 5/2 way is normally used to control the action of double acting cylinders. The seal spacer assembly forms individual annular chambers opposite each valve port and the grooved spool either closes or allows flow between adjacent chambers, hence the position of the spool determines which ports are open or closed. The spool is moved by way of a manually or mechanically operated mechanism normally against a return spring. Operation may be by application or removal of a pilot air supply acting as a pilot piston. This form of control is utilized for electrical actuation where integral solenoid valves control the pilot air supply. 4.1.2 Optional features (Falcon II) N - No-voltage release (latching) With the coil first energized, the palm button is then manually moved and latched. The inward movement of the palm button causes the valve to shift. When the coil is de-energized, the palm button and latching mechanism are automatically tripped, allowing the valve to return to its original position. see Figure 4. R - No-voltage release (non-latching) With the coil first energized, the palm button is then manually moved. The inward movement of the palm button causes the valve to shift. When the coil is de-energized, the palm button automatically returns to its original position. see Figure 5. L - Manual locking override Manually depress palm button and rotate clockwise for maintained condition, must manually disengage to return to original position. See Figure 6. M - Momentary override Spring return momentary push type, must hold in to actuate. See Figure 7. H - Hex drive maintained override Insert allen key in hex head screw and rotate clockwise (4-5 turns) to shift spool. Valve will stay put until hex head screw is rotated counter clockwise (4-5 turns) back to original position. See Figure 8. E - External pilot The ⅛ NPT external pilot connection requires a separate auxiliary pressure line to the valve. This feature should be used when the controlled pressure is below the minimum 3 bar (45 psi) operating pressure. D/C - Dual coil option Five way valves are available with a coil/ pilot valve on each end of the Falcon II valve, coil 'A' and coil 'B'. When coil 'A' is energized the valve will shift. If coil 'A' is then de-energized, the valve will remain in this position. The valve will not return to the original state until coil 'A' is de-energized and coil 'B' is energized. The process is the same for coil 'B'. Notes - For dual coil valves The valve may be in either position upon installation. Refer to the air flow diagrams and energize the appropriate coil (with air) to reset valve to the desired position. Dual coil valves require both an electrical signal and air pressure to operate. See air flow diagram for air pressure requirements. If either or both inputs are lost the valve will remain in it s current position. Both coils should never be energized simultaneously. Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Page 5 of 9

4.1.3 Optional features (Falcon II II) N - No-voltage release (latching) With the coil first energized, the palm button is then manually moved and latched. The inward movement of the palm button causes the valve to shift. When the coil is de-energized, the palm button and latching mechanism are automatically tripped, allowing the valve to return to its original position. See Figure 9. L - Manual locking override Manually depress palm button and rotate clockwise for maintained con dition, must manually disengage to return to original position. See Figure 10. M - Momentary override Spring return momentary push type, must hold in to actuate. See Figure 11. H - Hex drive maintained override Insert allen key in hex head screw and rotate clockwise (4-5 turns) to shift spool. Valve will stay put until hex head screw is rotated counter clockwise (4-5 turns) back to original position. See Figure 12. D/C - Dual coil option Five way valves are available with a coil/ pilot valve on each end of the Falcon II valve, coil 'A' and coil 'B'. When coil 'A' is energized the valve will shift. If coil 'A' is then de-energized, the valve will remain in this position. The valve will not return to the original state until coil 'A' is de-energized and coil 'B' is energized. The process is the same for coil 'B'. Note - For dual coil valves The valve may be in either position upon installation. Refer to the Air Flow Diagrams and energize the appropriate coil (with air) to reset valve to the desired position. Dual coil valves require both an electrical signal and air pressure to operate. See air flow diagram for air pressure requirements. If either or both inputs are lost the valve will remain in its current position. Both coils should never be energized simultaneously. Figure 9 Figure 10 Figure 11 Figure 12 Page 6 of 9

Air line designation ¼" NPT or BSP air ports for inlet, outlet and exhaust A Spring return valve Description of operation: Solenoid de-energized - Air flows from outlet port 2 to exhaust port 3. Solenoid energized - Air flows from inlet port 1 to outlet port 2. Dual coil valve Description of operation: Coil B de-energized - Air flows from inlet port 1 to outlet port 2 and exhausts from port 4 to 5. Coil A energized - Air flows from inlet port 1 to outlet port 4 and exhausts from port 2 to 3. B Spring return valve Description of operation: Solenoid de-energized - Air flows from inlet port 1 to outlet port 2 and exhausts from port 4 to 5. Solenoid energized - Air flows from inlet port 1 to outlet port 4 and exhausts from port 2 to 3. 4.2 Specifications Operating pressure: 45-120 psig Operating temperature: -20 C to 65 C (I/S only) -20 C to 82 C Operating media: Non lubricated filtered air to 20 microns 4.3 Field wiring Complete the electrical wiring in accordance with National and local Electrical requirements. The ground wire should be secure under the green screw. Check all screws for tightness. 4.4 (Air line) installation considerations Air mains and lines should be large enough to avoid excessive pressure loss under conditions of maximum flow. Air lines should be installed with as few restrictions as possible if the cost of compressed air is to be kept to a minimum. Sharp turns in piping should be avoided for more effecient air flow and economical air power. It is advisable to pitch the mains in the direction of air flow so that both gravity and air flow will carry the water to traps or water legs located at frequent intervals. To help in preventing condensed moisture from reaching the point of usage, down pipes should never be taken directly from the bottom of air pipes or mains. Connection should be made at the top of the main and a long radius return bend used. 4.5 Air flow Pipe sizes are normally determined on semi empirical lines, basis for selection being an acceptable pressure drop e.g. not more than 10% of the applied pressure. In sizing pipes, consideration should be given to likely future demands, as a system will be inefficient if the demand outgrows the supply. It is always better to over size mains as this will reduce air velocity and make water separation more effective. Page 7 of 9

4.6 Air service equipment The importance of proper filtration (20 micron) and lubrication of the air supply to pneumatic equipment can never be over-emphasized as a means of decreasing friction and preventing corrosion and wear due to moisture and abrasive solids being present in the air supply. At higher pressures than recommended, pneumatic equipment can wear excessively with no significant increase in output and compressed air is consequently wasted. There is much to be gained, therefore, from providing pneumatic equipment with serviced air by including suitable air line filters, pressure regulators and lubricants in the installation. 4.7 Tubes and fittings The use of copper, stainless steel, nylon or polyethylene tube is recommended for piping up air circuits and equipment. As a general rule, pipe threaded fittings should not be assembled to a specific torque because the torque required for a reliable joint varies with thread quality, port and fitting materials, sealant used, and other factors. The suggested method of assembling pipe threaded connections is to assemble them finger tight and then wrench tighten further to a specified number of turns from finger tight. The assembly procedure given below is for reference only, the fitting should not be over tightened for this will lead to distortion and most likely, complete valve failure. 1. Inspect port and connectors to ensure that the threads on both are free of dirt, burrs and excessive nicks. 2. Apply sealant/lubricant or PTFE tape to the male pipe threads. With any sealant tape, the first one or two threads should be left uncovered to avoid system contamination. 3. Screw the connector into the port to the finger tight position. 4. Wrench tighten the connector aproximately 1-2 turns (to seal) from finger tight. again this is only reference - the fitting should NOT be over tightened. Special notice Delrin valve bodies are fitted with hellicoils therefore an extra effort should be made NOT to overtighten pipe fittings or retaining screws (0.5-1 turns from finger tight to seal). Overtightening will result in valve failure or pull hellicoils from valve body. Maintenance Routine maintenance is usually confined to the periodic replenishment of dow corning III lubricant or equivalent to spool and spring. Page 8 of 9

Exploded assembly of 3 and 5 way 1.1 C v Falcon II Bush V5084 OZOIN070/01062 5/2 V5042 6 off 3/2 V5042 4 off OZOIN070/01062 Pilot piston V5119 OZOIN070/00125 Pilot piston end cap V5243 Valve body 5/2 V5246 3/2 V5314 OZOMN010/0130 OZOIN070/00125 Spacer 5/2 V4734 5 off 3/2 V4734 3 off Cap screws OSMO4KS16 Bush V5084 Pilot piston seal V4163 Spring V4571 Tell-tale cover V5247 Spring end cap V5244 Cap screws OSMO4KS40 Tell-tale pin V5026 Spool 5/2 V5212 3/2 V5313 Solenoid valve and coil specification Type: 3/2 way 5/2 way C v : 0.5 0.7 1.1 1.2 3.5 Material: Alu. Brass Stainless steel Connection: ¼" NPT ½" NPT ¼" BSP Operating pressure range: 45-120 psig Orifice size: ¼" Supply type: VAC VDC Supply voltage: 24 48 110/120 125 220/240 Consumption: 0.5 W 0.8 W 2.8/3.8 W 1.0 W 3.5/4.3 W Operating current: 22 ma 12.5 ma 28/35 ma 8.5 ma 17.5/17 ma These installation and operating instructions are based on document TECHUK-48 Rev 0 used for ATEX certification of the Westlock Translations Where translated the copy is taken from the original English document -EN as checked by the relevant notified certification body and therefore the original English document will prevail. No rights or liability can be derived from any translation. Page 9 of 9