Multi-Position Air Handler with Energy-Saving Motor ½ to Tons Standard Features Suitable for use with refrigerants R-0A and R- All-aluminum evaporator coil Check flowrater expansion device for cooling and heat pump applications EEM fixed-speed motor Enhances the performance of your Goodman brand air conditioner or heat pump Multi-position upflow, downflow or horizontal Built-in coil has horizontal, vertical, and downflow drain pans with secondary drain connections Complies with the Factory-Sealed Air Handling Credit as listed in the 00 Florida Building Code, Chapter, Section 60..A.. AHRI Certified; ETL Listed Cabinet Features Fully insulated, painted steel cabinet with attractive Architectural Gray finish Built-in filter rack for filter (filter not included) Low-voltage cabinet connections Power supply on top Low-voltage entry on top or side Factory sealed to achieve % or less leakage rate at.0 water gauge external duct static pressure * Complete warranty details available from your local dealer or at www.goodmanmfg. com. To receive the 0-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-G www.goodmanmfg.com / Supersedes /
Nomenclature A S P F 0,6,7,8 6 0 AA, Brand Engineering * A Single-piece Major/ Minor Revisions Air Handler * Not used for inventory management Unit Application Refrigerant Charge C Ceiling Mount PSC Motor No Digit = R- only D Downflow PSC Motor 6 = R-0A or R- E Multi-Position Variable-Speed Motor R Multi-Position PSC Motor Electrical S Multi-Position EEM Motor 08/0 V, Phase, 60 Hz W Wall Mount PSC Motor Nominal Capacity Range @ SEER Cabinet Finish Multi-Position & Downflow Applications U Unpainted 7 ½ to ½ Tons (for Export Systems) P Painted 80 ½-½ Tons N Uncased 6 -½ Tons Ceiling Mount & Wall Mount Applications Expansion Device (Nominal Cooling Capacity/ Electric Heat kw) F Flowrater 80 ½ Tons Cooling/ kw Electric Heat T Expansion Valve 0 Tons Cooling/ kw Electric Heat 608 Tons Cooling/ 8 kw Electric Heat www.goodmanmfg.com SS-G
Specifications 806* 066* 76* 606* Nominal Ratings Cooling (BTU/h) 8,000-0,000 0,000-6,000 0,000-6,000,000-60,000 CFM (High/ Low),08 / 60,0 / 600,0 / 600,000 /,00 Blower Diameter ½ 0⅝ 0⅝ 0¹⁵/₁₆ Width 8 0⅝ 0⅝ 0¹¹/₁₆ Coil Drain Connection FPT ¾ ¾ ¾ ¾ Service Valve Liquid ⅜ ⅜ ⅜ ⅜ Suction ¾ ⅞ ⅞ ⅞ Electrical Data Voltage 08 / 0 08 / 0 08 / 0 08 / 0 Electric Heat Capacity (kw), 8, 0,, 6, 8, 0,, 0,,, 6, 8, 0,, 0, 0,, 0, Min Circuit Ampacity.6 /.6.8 /.8. /. 6.6 / 6.6 Max. Overcurrent Device / amps / amps / amps / amps Min. / Max VAC 7 / 7 / 7 / 7 / Blower Motor A/ HP. / ½.0 / ¾. / ¾. / ¾ Ship Weight (lbs) 76 76 SS-G www.goodmanmfg.com
Dimensions Model A B C D E F G H I J 806* 6¾ 7½ ½ 0 ½ ¹⁵/₁₆ 7⅛ 7¹⁵/₁₆ 066* ¼ 0 ⅝ ¹⁵/₁₆ ⅝ ¹⁵/₁₆ ¹³/₁₆ 76* ¼ 0 ⅝ ¹⁵/₁₆ ⅝ ¹⁵/₁₆ ¹³/₁₆ 606* ¼ 0 ⅝ ¹⁵/₁₆ ⅝ ¹⁵/₁₆ ¹³/₁₆ www.goodmanmfg.com SS-G
Airflow Data Model Motor Speed Tap CFM deliverd against External Static Pressure 0. 0. 0. 0. 0. Low (T) 700 670 60 0 Med-Low (T) 80 78 76 7 70 806* Medium (T) 0 00 80 80 8 Med-High (T),07,0,0 7 60 High (T),0,,08,00,000 Low (T),060 86 600 0 Med-Low (T),0 0 7 7 60 066* Medium (T),6,070,00 60 Med-High (T),8,0,,0,00 High (T),,,0,,6 Low (T),060 86 600 0 Med-Low (T),0 0 7 7 60 76* Medium (T),6,070,00 60 Med-High (T),8,0,,0,00 High (T),,,0,,6 Low (T),,7,7 0 8 Med-Low (T),,0,,60, 606* Medium (T),660,60,,0, Med-High (T),0,870,80,70,6 High (T),,070,000,6, Notes: Assumes dry coil with filter in place; SCFM correction for wet coil = % All models are shipped from the factory with the speed tap set on T. SS-G www.goodmanmfg.com
****B*/D* Wiring Diagram HTR TL M R M 6 7 8 HTR TL HTR TL M M R M M 6 7 8 HTR TL HTR TL HTR TL M M M M M M R R 6 7 8 HTR TL HTR TL HTR TL HTR TL M M M M7 M M M6 M8 R R 6 7 8 L L L L L L L L ONE () ELEMENT ROWS TWO () ELEMENT ROWS THREE () ELEMENT ROWS FOUR () ELEMENT ROWS L L L L NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCOING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. SEE NOTE TERMINAL OCK SHOWN FOR 0HZ MODELS ONLY L L EQUIPMENT GROUND USE COPPER OR ALUMINUM WIRE 08/0 VOLTS R C G WW Y Y O DH G L L 6 7 8 PLF 6 7 8 PLF EM C LGN PLF GR SEE NOTE SEE NOTE COPPER OR ALUMINUM POWER SUPPLY (SEE RATING PLATE) USE MIN. 7 C FIELD WIRE IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. GR CR C V SEE NOTE 0 TR FUSE HOLDER OR EM C L G N FUSE HOLDER TR EM TB R CR EBTDR V COLOR CODE ACK RED YELLOW UE 6 PLF R C G WW Y Y O DH GR COMPONENT CODE GREEN RPLE OWN ITE EVAPORATOR MOTOR TERMINAL BOA RELAY CONTROL RELAY ELECTRONIC OWER TIME DELAY RELAY WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE TR PLF TL HTR TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS Notes: ) Red wires to be on transformer terminal "" for 0 volts and on terminal "" for 08 volts. ) See composite wiring diagrams in installation instructions for proper low voltage wiring connections. ) Confirm speed tap selected is appropriate for application. If speed tap needs to be changed, connect purple wire from terminal of CR relay to appropriate tap at TB ) Brown and white wires are used with Heat Kits only. CR EM C 00A0007 REV B Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 6 www.goodmanmfg.com SS-G
****C*/E* Wiring Diagram Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-G www.goodmanmfg.com 7
Accessories Heat Kit Selection 806* 066* 76* 606* HKR-0* X X X X HKR-0*, HKR-0C* X X X X HKR-06* X X X X HKR-08*, HKR-08C* X¹ X¹ X¹ X HKR-0*, HKR-0C* X¹ X¹ X¹ X HKR-C* X² X² X² X¹ HKR-0C* X² X² X¹ HKR-C* X² X² ^ HKR-* X² X² X² X¹ ^ HKR-0* X² X² X¹ * Revision level that may or may not be designated C Circuit breaker option ^ Heat kit requires three-phase power supply ¹ Air handler must be on speed tap,,, or ² Air handler must be on speed tap or. Single Point Kit ** Model HKR-C HKR-0C HKR-C SPW-0 X X X ** Must be installed along with any of the above compatible heat kits. This kit will fit any air handler as long as a compatible heat kit is installed in the unit. Filters Filter # Qty Required 80 FIL-6-06 FIL 8-6 60 FIL 8-6 Expansion Valve Kits for Air Conditioning and Heat Pump Applications Kit Number Description Application Refrigerant Tonnage: Outdoor Unit XVB8-6C 0% Bleed Valve AC Only R- ½ - Ton XVB-60C 0% Bleed Valve AC Only R- ½ - Ton XV8-6C Non-bleed Valve AC Only R- ½ - Ton XV-60C Non-bleed Valve AC Only R- ½ - Ton TXN Non-bleed Valve AC or HP R- ½ - Ton TXN Non-bleed Valve AC or HP R- ½ - Ton TXN Non-bleed Valve AC or HP R- ½ - Ton TXN Non-bleed Valve AC or HP R-0A ½ - Ton TXN Non-bleed Valve AC or HP R-0A ½ - Ton TXN Non-bleed Valve AC or HP R-0A ½ - Ton Drain Pan Insulation Kits Downflow Applications Horizontal Applications Chassis Size Insulation Kit Chassis Size Insulation Kit Small (½ ) DPI8-0/0 Small (½ ) DPIH8- Medium (½ ) DPI6-/0 Medium (½ ) DPIH6- Large ( ) DPI8-60/0 Large ( ) DPIH8-6 Note: Each kit contains enough material to modify 0 coils Note: Each kit contains enough material to modify 0 coils Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 00 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. 8 www.goodmanmfg.com SS-G