Air Handler with Painted Cabinet Standard Features Suitable for use with refrigerants -40A and - Check flowrater expansion device Direct-drive, multi-speed motor Transformer and blower time-delay on all units Copper tube/aluminum fin coil Complies with the Factory-sealed Air Handling Credit with or without field-installed filter kits as listed in the 00 Florida Building Code, Chapter, Section 0..A.. AHI Certified ETL Listed Cabinet Features Fully insulated, painted steel cabinet with attractive Architectural Gray finish Built-in coil has horizontal, vertical, and downflow drain pans with secondary drain connections Built-in filter rack for filter (filter not included) Power supply entry at top; low-voltage entry on top and both sides Factory-sealed to achieve % or less leakage rate with or without field-installed filter kits at.0 water gauge external duct static pressure ½ to 5 Tons Multi-Position, Three-Speed Contents Nomenclature...... Dimensions...4 Airflow Data...5 Wiring Diagram... Accessories...7 * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 0-Year Parts Limited Warranty, online registration must be completed within 0 days of installation. Online registration is not required in California or Québec. SS-G www.goodmanmfg.com 5/0A Supersedes 5/0
Nomenclature A P F 4 4 5,,7,8 0 AA, Brand Engineering * A Single-piece Major/ Minor evisions Air Handler * Not used for inventory management Unit Application efrigerant Charge C Ceiling Mount PSC Motor No Digit = - only D Downflow PSC Motor = -40A or - E Multi-Position Variable-Speed Motor Multi-Position PSC Motor Electrical S Multi-Position EEM Motor 08/40 V, Phase, 0 Hz W Wall Mount PSC Motor Nominal Capacity ange @ SEE Cabinet Finish Multi-Position & Downflow Applications U Unpainted 7 ½ to ½ Tons (for Export Systems) P Painted 80 ½-½ Tons N Uncased 4 -½ Tons Ceiling Mount & Wall Mount Applications Expansion Device (Nominal Cooling Capacity/ Electric Heat kw) F Flowrater 805 ½ Tons Cooling/ 5 kw Electric Heat T Expansion Valve 405 Tons Cooling/ 5 kw Electric Heat 08 Tons Cooling/ 8 kw Electric Heat www.goodmanmfg.com SS-G
Specifications 84* * 00* * Nominal atings Cooling (Btu/h) 8,000-4,000 8,000-0,000 0,000,000 CFM (High/ Med/ Low),05/ 70/ 570,05/ 780/ 545,0/,0/ 80,0/,40/ 55 Blower Diameter ½" ½" ½" ½" Width " " 8" " Coil Drain Connect FPT ¾" ¾" ¾" ¾" Service Valve Liquid Line ⅜" ⅜" ⅜" ⅜" Suction Line ¾" ⅞" ¾" ¾" Electrical Data Voltage 08/40 08/40 08/40 08/40 Min Circuit Ampacity./../../../. Max. Overcurrent Device (amps) 5 / 5 5 / 5 5 / 5 5/5 Min./ Max VAC 7/ 5 7/ 5 7/ 5 7/ 5 Blower Motor A/ HP.7/ ⅓.48/ ¼.4/ ⅓.4/ ⅓ Ship Weight (lbs) 55 44 4 4* 74* 480* 4* Nominal atings Cooling (Btu/h),000-4,000,000-4,000 48,000-0,000 48,000-0,000 CFM (High/ Med/ Low) 5 / 400 / 50,5/,550/,45,85/,875/,50,5/,75/,585 Blower Diameter 0⅝" 5/" 0⅝" 0⅝" Width 8" 0 ¹/" 0⅝" 0⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" Service Valve Liquid Line ⅜" ⅜" ⅜" ⅜" Suction Line ⅞" ⅞" ⅞" ⅞" Electrical Data Voltage 08/40 08/40 08/40 08/40 Min Circuit Ampacity.7/.7 4./4. 5.4/5.4 5.4/5.4 Max. Overcurrent Device (amps) 5 / 5 5 / 5 5 / 5 5/5 Min./ Max VAC 7/ 5 7/ 5 7/ 5 7/ 5 Blower Motor A/ HP.5/ ½./ ½ 4./ ¾ 4./ ¾ Ship Weight (lbs) 0 5 8 SS-G www.goodmanmfg.com
Dimensions Model A B C D E F G H I J 84* 4⅛ ½ 5½ 0 4½ ¹⁵/₁₆ ⅛ 7¹⁵/₁₆ * 4¾ 7½ ½ 0 4½ ¹⁵/₁₆ 7⅛ 7¹⁵/₁₆ 00* 4¾ 7½ ½ 0 4½ ¹⁵/₁₆ 7⅛ 7¹⁵/₁₆ * 4¾ 7½ ½ 0 4½ ¹⁵/₁₆ 7⅛ 7¹⁵/₁₆ 4 / 5 4* 5¼ 4 0 4½ ¹⁵/₁₆ ⅝ ¹⁵/₁₆ 4 / 5 74* 5¼ 4 0 4½ ¹⁵/₁₆ ⅝ ¹⁵/₁₆ 4 / 5 480* 5¼ 4 0 4½ ¹⁵/₁₆ ⅝ ¹⁵/₁₆ 4 / 5 4* 5¼ 4 0 4½ ¹⁵/₁₆ ⅝ ¹⁵/₁₆ 4 / 5 4 www.goodmanmfg.com SS-G
Airflow Data Model 84* * 00* * 4* 74* 480* 4* CFM delivered against External Static Pressure Speed 0." 0." 0." 0.4" 0.5" High,55,00,05 50 85 Med. 40 80 80 85 755 Low 5 5 50 0 550 High,5,085,05 5 5 Med. 80 85 780 750 80 Low 00 570 545 500 45 High,85,5,40,55,05 Med.,40,0,0,40,050 Low,075,00 80 0 840 High,0,40,55,00,00 Med,70,0,40,075 80 Low,045,005 55 885 805 High,700,0,5,545,505 Med.,500,440,400,50,45 Low,70,00,50,0,0 High,05,000,5,80,780 Med.,85,5,550,470,40 Low,40,45,45,80,05 High,50,0,070,000,40 Med.,40,0,05,80,70 Low,0,00,50,575,550 High,50,05,040,70,880 Med.,0,5,85,85,750 Low,70,5,585,55,455 Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (08V / 40V SS-G www.goodmanmfg.com 5
Wiring Diagram HT TL M M D D 4 5 7 8 HT TL HT TL D M M M M4 D D D D 4 5 7 8 D HT TL HT TL D HT TL D YL YL M M M M M4 M D YL D D 4 B 5 7 8 D HT TL HT TL D HT TL YL HT4 TL D D M M M5 M7 YL 4 M M4 M M8 B 5 D 7 YL 8 D L L L L L L L L ONE () ELEMENT OWS TWO () ELEMENT OWS THEE () ELEMENT OWS FOU (4) ELEMENT OWS L L L L NOTE: EN INSTALLING HEATE KIT, ENSUE SPEED TAP DOES NOT EXCEED MINIMUM OWE SPEED (MBS) SPECIFIED FO THE AIHANDLE/HEATE KIT COMBINATION ON THIS UNIT'S S& PLATE. AFTE INSTALLING OPTIONAL HEAT KIT, MAK AN "X" IN THE POVIDED ABOVE. MAK ACCODING TO NUMBE OF HEATE ELEMENT OWS INSTALLED. NO MAK INDICATES NO HEAT KIT INSTALLED. TEMINAL OCK SHOWN FO 50HZ MODELS ONLY L L EQUIPMENT GOUND USE COPPE O ALUMINUM WIE 08/40 VOLTS D G B S D GD 4 5 7 8 L L PLF 4 5 7 8 PLF PLF SEE NOTE B D B SEE NOTE4 C EM HI LO M M NC NO EBTD COM SEE NOTE G SEE NOTE 5 D G EBTD NO D K XFM- D D XFM-C COM K C NC SPEEDUP M M COPPE O ALUMINUM POWE SUPPLY (SEE ATING PLATE) USE MIN. 75 C FIELD WIE SEE NOTE THEE SPEED MOTO WIING (SELECT MODELS ONLY) SEE NOTE IF EPLACEMENT OF THE OIGINAL WIES SUPPLIED WITH THIS ASSEMY IS NECESSAY, USE WIE THAT CONFOMS TO THE NATIONAL ELECTIC CODE. (T ) (M) D (M ) (COM) C LOW MEDIUM HIGH B C D 5 4V 4 EM SPEED D SEE NOTE 40 T C B B D EM EBTD D T COLO CODE ACK G GEEN D YL ED YELLOW PLE B BOWN UE ITE COMPONENT CODE 4 4V 5 B 5 4 PLF WIING CODE FACTOY WIING HIGH VOLTAGE LOW VOLTAGE FIELD WIING HIGH VOLTAGE LOW VOLTAGE NOTE EM EVAPOATO MOTO T TANSFOME C UN CAPACITO PLF FEMALE PLUG CONNECTO S STAIN ELIEF MALE PLUG CONNECTO ELAY FUSE LINK EBTD ELECTONIC OWE TIME TL THEMAL LIMIT Notes: DELAY ELAY HT HEAT ELEMENTS ) ed wires to be on transformer terminal "" for 40 volts and on terminal "" for 08 volts. ) See composite wiring diagrams in installation instructions for proper low voltage wiring connections. ) Confirm speed tap selected is appropriate for application. If speed tap needs to be changed, connect appropriate motor wire (ed for low, Blue for medium, and Black for high speed) on "COM" connection of the EBTD. Inactive motor wires should be connected to "M or M" on EBTD. 4) Brown and white wires are used with Heat Kits only. 5) EBTD has a 7 second on delay when "G" is energized and a 5 second off delay when "G" is de-energized. 040M0070 EV A C EBTD G G ESSUE SENSITIVE 4000, TYPE A. OUND. Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com SS-G
Accessories Heat Kits 84 00 4 74 480 HK-0* X X X X X X X X HK-05*, HK-05C* X X X X X X X X HK-0* X X X X X X X X HK-08*, HK-08C* X X X X X X X X HK-0*, HK-0C* X X X X X X X X HK-5C* X X X X X X X X HK-0C* X X X X X HK-C* X X X X X ^ HK-5* X X X X X X ^ HK-0* X X X X X 4* * evision level that may or may not be designated C Circuit breaker option ^ Heat kit requires three-phase power supply ¹ Air handler must either be on medium or high speed ² Air handler must be on high speed ³ For static pressure of 0. or higher, air handler must be on medium or high speed Expansion Valve Kits for Air Conditioning and Heat Pump Applications Kit Number Description Application efrigerant Tonnage: Outdoor Unit XVB8-C 0% Bleed Valve AC Only - ½ - Ton XVB4-0C 0% Bleed Valve AC Only - ½ - 5 Ton XV8-C Non-bleed Valve AC Only - ½ - Ton XV4-0C Non-bleed Valve AC Only - ½ - 5 Ton TXN Non-bleed Valve AC or HP - ½ - Ton TXN Non-bleed Valve AC or HP - ½ - Ton TX5N Non-bleed Valve AC or HP - ½ - 5 Ton TXN4 Non-bleed Valve AC or HP -40A ½ - Ton TXN4 Non-bleed Valve AC or HP -40A ½ - Ton TX5N4 Non-bleed Valve AC or HP -40A ½ - 5 Ton Single Point Kit ** Model HK-5C HK-0C HK-C SPW-0 X X X ** Must be installed along with any of the above compatible heat kits. This kit will fit any air handler as long as a compatible heat kit is installed in the unit. Drain Pan Insulation Kits Downflow Applications Horizontal Applications Chassis Size Insulation Kit Chassis Size Insulation Kit Small (5½ ) DPI8-0/0 Small (5½ ) DPIH8- Medium (½ ) DPI-4/0 Medium (½ ) DPIH-4 Large ( ) DPI48-0/0 Large ( ) DPIH48- Note: Each kit contains enough material to modify 0 coils Filters Filter # Qty equired 84 FIL 8- FIL--4 00/ FIL--4 4 FIL 48-74 FIL 48-480/4 FIL 48- SS-G www.goodmanmfg.com 7
Notes Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 00 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. 8 www.goodmanmfg.com SS-G