Power HT kw. Outputs from 115 to 320 kw

Similar documents
available in battery up to 4 units for a total of 560 kw

VICTRIX PRO Wall-hung modular condensing boiler for heating only

VERY LOW TEMPERATURE, CONDENSING, PRESSURIZED BOILER. From 69 kw Output (67 kw Input) to 1550 kw Output (1520 kw Input)

STAINLESS STEEL CONDENSING GENERATOR RANGE RATED. MODEL Heat thermal input 65,5. 62,0 Heat output (80 C/60 C) 14,0

Innovo Condensing high efficiency water heater

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

Spare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5

XIII. Repair Parts 106

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

DIRECT-AIR ILB / ILT Series Rectangular duct fans

Crest Heating Boilers FBN(L)

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER. Model UCS-240 PARTS, KITS & OPTIONAL ACCESSORIES

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010

CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER. Model DMG-240 PARTS, KITS & OPTIONAL ACCESSORIES

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

Controls and Accessories Part Number Controls and Accessories Part Number

Crest Heating Boilers FBN(L)

... Cabinet Heaters Gas & Oil Fired Heaters ... ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

VIESMANN. Datasheet Part no.: see pricelist, price upon request Not suitable for sizing the boiler. For this, see the separate technical guide.

EcoBlue combi, system and heat only boilers. Range guide

Raptor 085HB-270HB & 155CB Submittal

Hamilton 3VO Submittal

Raptor 085HB-270HB & 155CB Submittal

Data Sheet 10/ EN November 2004

Data sheet: Wilo-CronoLine-IL 125/210-5,5/4

Product range Solex Technical data and dimensioning. 5 Years

Data sheet: Wilo-VeroLine-IPL 100/ /4

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

VIESMANN VITODENS 222-F

Data sheet: Wilo-CronoLine-IL 65/130-4/2

Data sheet: Wilo-CronoLine-IL 50/200-1,5/4

Data sheet: Wilo-CronoLine-IL 50/120-2,2/2

Data sheet: Wilo-CronoLine-IL 80/145-1,1/4

Data sheet: Wilo-CronoLine-IL 65/160-5,5/2

ONE STAGE GAS BURNERS RDBS SERIES

Data sheet: Wilo-VeroLine-IPL 65/ /2

Oil, Gas and Dual Fuel Burners

Data sheet: Wilo-VeroTwin-DPL 65/ /2

Date: Project #: Engineer: Prepared By: Bid Date:

BFC Cyclone Condensing Glass-Lined Water Heater

Power Direct Vent PDV T Model

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

Data sheet: Wilo-CronoLine-IL 100/250-5,5/4

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model UNO. R EN - Edition 01-15/10/2007

Thermo 90 S.21 Diesel - 24 Volt

EcoBlue combi, system and heat only boilers. Range guide

Data sheet: Wilo-VeroTwin-DPL 40/ /4

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F

Data sheet: Wilo-CronoLine-IL 40/220-1,5/4

Linea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN

Cooling system components, removing and installing

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

VIESMANN. VITOMAX 100-HS High pressure steam boiler Steam output 1.0 to 6.4 t/h. Datasheet. VITOMAX 100-HS Type M33A. Part no. and prices on request

UB Series 2 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER. Models UB90-50 UB90-75 UB90-100

Doing more for clean environment and energy saving

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

BFC Cyclone Condensing Glass-Lined Water Heater

Q90-50/75/100 Series 4

Data sheet: Wilo-CronoTwin-DL 65/250-4/4

Data sheet: Wilo-VeroLine-IPL 65/ /2

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT

UB90-50/75/100 Series 4

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

VALVE WITH UV ACTUATOR

... Cabinet Heaters Gas & Oil Fired Heaters ...

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

Q90-50/75/100 Series 2 Q Series 3

The Baxi GA Combi & System Boiler Range

HWT 1402/9603. free cooling

Oil, Gas and Dual Fuel Monoblock Burners

JUMBO 7 75 JUMBO GENERATORI CARRELLATI D ARIA CALDA A GRANDE PORTATA HEAVY DUTY MOBILE SPACE HEATERS

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

CHAPTER 2 : ESSENTIAL CHARACTERISTICS OF THE VEHICLE AND ENGINE AND INFORMATION CONCERNING THE CONDUCT OF TESTS

MAGNA F 220 1x230V PN6/10

COMPONENTS FOR SOLAR THERMAL SYSTEMS

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

System components for sample gas sampling

Composite PEX-AL-PEX Tubing

ABB MEASUREMENT & ANALYTICS DATA SHEET. System components for sample gas sampling

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Remote reading dial thermometers, version for industry

Zirconia Oxygen Probe

BENSON AMBIRAD. ... Cabinet Heaters Gas & Oil Fired Heaters ... HEATI NG AND VENTILATION S OLUTIONS

Data sheet: Wilo-VeroTwin-DPL 50/ /4

Eco Home SPARE PARTS CATALOGUE. - October

Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 WALL MOUNTED GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev E

WALL MOUNTED GAS BOILER. Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 PARTS, KITS & OPTIONAL ACCESSORIES

Models WALL MOUNTED CONDENSING GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES DKVLT-075 DKVLT-150 DKVLT-050 DKVLT-200 DKVLT-299

Installation manual. Exhaust system. Marine engines DI09, DI13, DI16. 02:04 Issue 9.0 en-gb. Scania CV AB 2017, Sweden

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Transcription:

Power T -0 kw luminium-silicon exchanger with glass wool insulation: high efficiency and reliability and long life Low emissions pre-mixing burner Digital control panel with back-lighted LCD display and advanced electronics to manage single and cascade installations (flue system to install up to boilers in cascade) Easy to transport and to install Outdoor sensor Circulating pump not included inside the boiler ydraulic system ydraulic connections on the rear side Sticking pump check system Flow and return NTC sensors Premixed low-emissions burner Thermoregulation system uilt-in climatic regulation (outdoor sensor included) Mixed zones systems (high and low temperatures) zone controllers as optional Cascade system installation option (up to 6 boilers) NTC sensor for DW cylinder control option eating and DW scheduler integrated in the control panel Control system Full electronic anti-frost device Electronic thermometer Flow over-temperature thermostat Outputs from to 0 kw eating only...80.0.80.0 Maximum heat input (heating) kw 70 60 00 Minimum heat input kw 0 0 8 8 Rated heat output Prated kw 66 0 9 Useful heat output at rated heat output and high temperature regime* P kw 0,9,6 6,8 0 9 Useful heat output at 0% of rated heat output and low temperature regime** P kw 7, 0,8, 69,7 8, 97, Useful efficiency at rated heat output and high temperature regime* ŋ % 87,7 87,7 87,9 88 88, 88, Useful efficiency at 0% of rated heat output and low temperature regime** ŋ % 98 98 98 97, 97, 97, Efficiency Pn (lower calorific value) - average temperature 70 C % 97, 97, 97, 97,9 98 98 Efficiency 0% (lower calorific value) - return temperature 0 C % 08,8 08,8 08,8 0, 0,6 0,7 NOx emissions mg/kwh 8 8 8 9 9 9 Minimum working temperature C - - - - - - eating temperature range C -80-80 -80-80 -80-80 Minimum pressure heating circuit bar 0, 0, 0, 0, 0, 0, Maximum pressure heating circuit bar 6 6 6 6 6 6 Flue ø mm 60 60 60 00 00 00 Maximum flue mass flow rate kg/s 0,0 0,07 0,077 0,097 0,8 0,6 Minimum flue mass flow rate kg/s 0,009 0,09 0,07 0,06 0,09 0,0 Maximum flue temperature C 60 6 6 6 6 6 Dimensions (h x l x p) mm x69x008 x69x008 x69x008 8x69x 8x69x 8x69x7 Net weight kg 0 0 0 8 Gas type Natural gas Power consumption W 60 70 00 0 0 0 uxiliary electrical power consumption - Full load elmax kw 0,60 0,70 0,00 0.0 0.0 0.0 uxiliary electrical power - Partial load elmin kw 0,0 0,0 0,0 0,00 0,06 0,0 uxiliary electrical power - Stand-by P S kw 0,00 0,00 0,00 0,00 0,00 0,00 Suggested pumps Magna Magna Magna Magna Magna Magna 0-80 () 0-80 () 0-80 () 0-80 () 0-80 () 0-80 () * igh temperature regime: 60 C return temperature at heater inlet and 80 C flow temperature at heater outlet ** Low temperature: 0 C return temperature (at heater inlet) () In case of Grundfos Magna modulating pump installation a signal converter (0V / 0-0V KPM) must be ordered 6

Dimensions Power T -80 kw 69 0 L L 89 I M I M K K 0 80 E C F G 0 D 0 80 E C 0 F G D 96 G mm 687 R-0000 mm R-0000 0 L mm 0 M mm 0 96 Power T. Power T. Power T.80 ir-flue duct mm Ø 0 Ø 0 Ø 0 eating system flow Flange DN 6 eating system return Flange DN 6 Gas inlet R R / Safety group connection R mm 60 mm 008 C mm 0 D mm 0 E mm F mm I mm 0 K mm 9

igh output condensing systems Installation instructions Power T -80 kw. Remove lower rear wall () of the Power T. Remove the gas connection leading upward and insert a 90 bend (). Turn 90 bend () in the desired position (side or towards the rear). Remove either the rear cover plate () or the side cover plate (). Mount lower rear wall () Side supply air connection (). Remove lower rear wall (). Remove the covering panel (). Mount the bend of the intake pipe (). Turn intake pipe elbow into the side position (). Mount lower rear wall () Rear supply air connection (). Remove lower rear wall (). Take out cover plate (). Mount straight intake pipe. Mount lower rear wall () RESISTENZ Water side LTO resistance CQU (mbar) 000 00 0 PERDITE EXCNGER DI CRICO PRESSURE SCMITORI DROP POWER T. -. POWER T.80 POWER T.0 POWER T.80 POWER T.0 % Time of heating functioning in a year Lavoro termico annuo PRODUZIONE ET PRODUCTION DI CLORE CCORDING IN FUNZIONE TO DELL TE OUTDOOR TEMPERTUR TEMPERTURE ESTERN mandata circuito riscaldamento eating flow Curva Caracteristic caratteristica curve ritornocircuito riscaldamento eating return Dew Punto point di rugiada = = C C Temperatura eating water acqua temperature di riscaldamento C Temperatura Outdoor temperature esterna C C EFFICIENCY OF TE OILER RENDIMENTO CLDI CCORDING FUNZIONE TO TE OUTPUT DELL POTENZ EMESS 0 00 PORTT Flow rate CQU (m³/h)[m /h] Efficiency% Rendimento% Output Potenza %

Dimensions Power T 0-0 kw flow flange DN 6 return flange DN 6 Power T Depth () mm.0.80.0.7.6.7

igh output condensing systems Installation instructions Power T 0-0 kw. Remove lower rear wall () of the Power T. Remove the gas connection leading upward and insert a 90 bend (). Turn 90 bend () in the desired position (side or towards the rear). Remove either the rear cover plate () or the side cover plate (). Mount lower rear wall () Side supply air connection (). Remove lower rear wall (). Remove the covering panel (). Mount the bend of the intake pipe (). Turn intake pipe elbow into the side position (). Mount lower rear wall () Rear supply air connection (). Remove lower rear wall (). Take out cover plate (). Mount straight intake pipe. Mount lower rear wall () Max lengths for the flue pipes with room air dependent working (type installation) Model Power T. Power T. Power T.80 Power T.0 Power T.80 Power T.0 Flue pipe ø mm 60 60 60 00 00 00 Max L. pipe inc. 90 bend m 60 60 0 60 60 60 These lengths are only for single boilers Decrease of the total lengths of the flue pipes: piece 90 bend: m piece bend: m piece bend: m