Boston Gear Ratiotrol

Similar documents
Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear RB Series

Boston Gear Ratiotrol

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

Boston Gear Ratiotrol

Boston Gear Ratiotrol

Centrifical Clutch Couplings

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

SAFTRONICS DF8 PLUS SERIES

TABLE OF CONTENTS SPECIFICATION CHART...8 RATIOPAX DCX/DCXplus BETA II BETAplus VEplus

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

CONTROL FEATURES AVAILABLE OPTIONS

Filtered PWM Speed Control for Permanent Magnet DC Motors

DC3N Non-Regenerative DC Drives

Enclosed In-Line Helical & Right Angle Helical Gear Drives

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Boston Gear. Adjustable-Speed Regenerative DC Motor Controllers. Installation and Operation Manual. Doc. No RBA-RG VEA-RG Series

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Fincor Series 2230 MKII/2240

TABLE OF CONTENTS STANDARD FEATURES

KBMD-240D MULTI-DRIVE

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

LOR Series Trig-O-Matic Lite Overload Release Clutch

AC & DC Adjustable Speed Controls and Motors. MTY (81) MEX (55) QRO (442)

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Copyright 2013 Automationdirect.com Incorporated All Rights Reserved

56 FRAME & 56C FRAME FRACTIONAL MOTORS From WorldWide Electric

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

INSTALLATION AND OPERATIONS MANUAL POWER OPERATED TUBING STORAGE REEL MODEL TSR-P PRODUCTS, INC.

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

Dayton DC Motor Control

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

High Frequency SineWave Guardian TM

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

BC141, BC142, BC142-5 & BC142-6 DC Control

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

Snap-Trol 183 Nema 1 Series

Model A Switching Logic Board. User s Manual. For Use With Minarik Full-Wave Regenerative Drives

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

SCR Power Controllers

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

Boston Gear Ratiotrol

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

Warner Electric UNIBRAKE Motor Brakes

POR SERIES Pneumatic Overload Release Clutches

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

Model 616 Rotating Disk Electrode Instruction Manual

********SERVICE MANUAL********* MODELS:

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

CABINET REEL OPERATING INSTRUCTIONS

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

INSP-3 Wiring Inspection Tester

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

XR500B Universal Voltage Regulator

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

CABINET REEL OPERATING INSTRUCTIONS

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

American Power Design, Inc.

RP-4000 Reserve Power Control

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

PALLET MASTER (PMD) OPERATING INSTRUCTIONS

Transcription:

Boston Gear Ratiotrol DC Motor Speed Control P-05-BG Doc. No. 85 Installation and Operation RP, RPR /6-/ HP RP, RPR /4- HP a division of Altra Industrial Motion

GENERAL INFORMATION Description Boston Gear Ratiopax Controllers statically convert single-phase AC line power to regulated DC for adjustable-speed armature control of shunt wound and permanent magnet motors. Model Types Table. Model Types Model Regulated Power Conversion Function Power Output VDC Uni-directional Run-Stop Reversing Run-Stop HP Range Source (single Phase) RP X X /6 - / 5V RPR X X 50 or 60 Hz RP X X /4-0V RPR X X 50 or 60 Hz Enclosure Nonventilated, dust resistant, NEMA Type, constructed of die-cast aluminum alloy. Ratings Armature Field 0-90 50 0-80 00. Service Factor...0. Duty...Continuous. Overload Capacity...50% for minute 4. AC Line Fuse Interrupting Capacity...5000 amperes 5. Speed Control Pot...00K ohms, W -Phase AC Input (Full Load) DC Output (Full Load) Component Ratings Rated Horsepower (HP) /6 /4 / / /4 Rated Kilowatts (KW) 0.4 0.87 0.49 0.7 0.560 0.746 Line Amps Motor Armature Amps Motor () Field Amps Table. Ratings 5 VAC Controller.9 5.0 6.0 8.7 ----- ----- 0 VAC Controller ----- ----- ----- ----- 5.9 8.8 KVA.48.58.7.0.4.0 90 VDC.0.8.5 5.4 ----- ----- 80 VDC ----- ----- ----- -----.8 5.5 50 VDC.0.0.0.0 ----- ----- 00 VDC ----- ----- ----- -----.0.0 Full-Load Torque (lb. ft.) with 750 RPM Base Speed Motor 0.5 0.75.0.5..0 Minimum Transformer KVA for Voltage Matching or Isolation 0.5 0.75 0.75.0.5.0 Controller Approximate Weight.0 lbs. (0.9kg.) Physical Data Standard Dimensions See Figure () Not applicable with permanent magnet motors. P-05-BG Doc. No. 85 Boston Gear Ratiotrol Manual

Operator Controls The operator controls, integrally mounted on the front panel, include the following: Models RP and RP - A calibrated SPEED control pot and a RUN/STOP toggle switch. Model RPR and RPR - A calibrated SPEED control pot and a FORWARD/STOP/REVERSE toggle switch. The reversing switch has a center position detent which provides antiplug protection. Operating Conditions. Line voltage Variation...+/-0% of rated. Line Frequency Variation...+/- Hertz. Ambient Temperature range...0 to 40 C ( F to 04 F) 4. Altitude (standard)...000 meters (00 feet) maximum Regulation Method Voltage Feedback with IR Compensation Load change 95% Table. Speed Regulation Characteristics Line Voltage +/-0% Variables Field Heating Cold/Normal Temperature +/- 0% Speed Range % +/-% 5-% +/-% 0: Performance Characteristics. Controlled Speed Range... 0 to motor base speed. Speed Regulation (See Table ) - Regulation percentages are of motor base speed under steady-state conditions.. Efficiency (at rated speed and rated load) a. Controller...99% b. Controller with motor...85% 4. Displacement Power Factor (at rated speed and rated load)...87% 5. Acceleration (nonadjustable)...by current limit 6. Current Limit (nonadjustable)...50% full-load torque (typical) P-05-BG Doc. No. 85 Boston Gear Ratiotrol Manual

Installation and Wiring. Report shipping damage to the carrier.. Unpack the controller and remove all packing material.. Remove the four screws on the front cover, and remove the cover from the enclosure. 8. Use T & B 85 fitting (or equal) to attach /4 conduit to the controller. 9. Use #4 AWG stranded wire for controller connections. Oversized or solid wire can break terminal strip barriers. Figure. Ratiopax Dimensions 4. Check components in the controller. All damaged components must be replaced. 5. The controller can be surface mounted, or the front cover can be removed and panel mounted. Never mount the controller immediately beside or above heat-generating equipment, or directly below water or steam pipes. If the controller is mounted in an enclosure, be sure the temperature in the enclosure does not exceed 55 C ( F). 7.5 (9) Mounting Holes.9 (5) Dia. ( Places on back) 9.00 (9) Note: Never mount the operator controls remotely. 6. If the controller is subjected to vibrations, it must be shock mounted..69 (8).6 (4).00 (76).65 (6).00 (76) 7. Be sure the line voltage and frequency are compatible with the controller rating. a. SEPARATE OVERCURRENT PROTECTION IS REQUIRED BY THE NATIONAL ELECTRICAL CODE. THE USER IS RESPONSIBLE FOR CONFORMING WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES WHICH GOVERN SUCH PRACTICES AS WIRING PROTECTION, GROUNDING, DISCONNECTS, AND OTHER PROTECTION. b. THE AVAILABLE SHORT-CIRCUIT CURRENT OF THE INPUT SUPPLY MUST BE LESS THAN 5,000 AMPERES SYMMETRICAL OR CONTROLLER DAMAGE MAY OCCUR. Short-circuit current can be limited by sizing the input supply transformer at 50 KVA or less, or by using correctly sized current limiting fuses in the input supply to the controller. Do not size the transformer less than the minimum transformer KVA listed in Table.. Dia. One End (9) Motor Shunt 5 or Field 0 VAC Motor Arm TBA 4.06 (5) 0. Connect the motor and single-phase power to the controller as shown in Figure.. Connect earth ground to the ground connection post inside the controller enclosure or to a front cover screw. Figure. Connections If one side of the AC line is grounded, connect it to Terminal. Motor may be either permanent magnet or shunt wound. If permanent magent, it will not have shunt field windings. Terminals and are on inside of front cover. 5 or 0 VAC Motor Arm Motor Shunt Field TBA 4 c. NEVER USE POWER FACTOR CORRECTION CAPACITORS ON THE INPUT LINE TO THE CONTROLLER. These capacitors can damage the solid-state components. 4 P-05-BG Doc. No. 85 Boston Gear Ratiotrol Manual

C Startup and Operation. Recheck the wiring to the controller before applying power. IF ONE OF THE AC SUPPLY LINES IS GROUNDED, IT MUST BE CONNECTED TO TERMINAL.. Remove the correct calibration resistor(s) from the controller circuit board with a wire cutter, as shown in Table 4 and Figure 4.. Replace the front cover on the enclosure and tighten the four screws. Controller HP Rating 4. Turn the SPEED control pot to zero on its dial. 5. Place the RUN/STOP/FORWARD/STOP/ REVERSE switch (whichever is applicable) in STOP position. 6. Apply AC input power to controller. TBA 4 Models RP, RPR Models RP, RPR Remove Resistors /6 ----- R, R, R4 /4 ----- R, R4 / /4 R4 / None SCR K C A D T R6 R6 C RV 50 ASSY NO. 046946 640 Table 4. Calibration Wires Figure 4. Circuit Board R7 R8 D5 D4 D7 D6 REV CALIBRATION RESISTORS R4 R R R Q R R R0 R9 7. Place the RUN/STOP switch in Run position or place the FORWARD/STOP/REVERSE switch in FORWARD position (whichever is applicable). 8. Turn the SPEED control pot slowly until the motor rotates. 9. If motor rotation is opposite to that desired, place the switch in STOP position, turn-off the AC input power, and interchange the motor armature leads at the motor connection box. E A K D8 D0 0 D9 R5 R7 C4 0 D R7 R8 E B C R 8 R Q4 8 R4 Q C5 CBB Q5 R0 R9 R 8 R5 R6 R Note: Varistor RV is located on 0V circuit boards only. C R8 R4 SCR K G A MAX SPD C6 RS 7 9 D F 6 NEVER USE LINE SWITCHING TO START AND STOP THE MOTOR. Resulting transients can damage the controller. 0. Models RPR and RPR only: To obtain opposite motor rotation, place the FORWARD/STOP/ REVERSE switch in STOP position and then in REVERSE position.. To obtain top speed, turn the SPEED control pot to 00 on its dial. Maintenance Maintenance consists of keeping the controller clean and dry. Refer to maintenance instructions supplied by the motor manufacturer. If the motor doesn t rotate, check the fuse on the controller front cover. If the fuse is blown, replace it with an exact replacement. SUBSTITUTE FUSES CAN CAUSE CONTROLLER DAMAGE. If the replacement fuse blows, turn-off the AC input power and refer to Table 5. Most controller failures are caused by incorrect connections, overload, or the accumulation of dirt, dust, or moisture. If motor operation becomes faulty, proceed as follows: BE SURE THE AC INPUT POWER IS TURNED-OFF BEFORE WORKING ON THE CONTROLLER. HIGH VOLTAGE IN THE CONTROLLER CAN CAUSE ELECTRIC SHOCK RESULTING IN PERSONAL INJURY OR LOSS OF LIFE.. Check for: a. Blown fuse b. Loose or missing terminal screws c. Unattached wires d. Charred, darkened, or punctured components and wires. If the SPEED control pot feels rough or stiff when rotated, an open or shorted pot is indicated.. Measure the AC input voltage to the controller on Terminals and 4, and compare with controller rating. 5 P-05-BG Doc. No. 85 Boston Gear Ratiotrol Manual

Table 5. Troubleshooting Indication Possible Cause Corrective Action. Controller fuse Wiring faulty, incorrect or Check all external wiring blows when AC grounded. terminating in the controller. input power is Motor shunt field shorted Repair or replace motor. applied to the or grounded. controller. Components shorted. Repair or replace controller.. Controller fuse Motor armature shorted or Repair or replace motor. blows when RUN/ grounded. STOP switch is Shorted SCR SCR or Replace circuit board or SCR. placed in RUN SCR, or circuit board. position.. Controller fuse Loose or corroded Check all terminal connections blows while motor connection, or wiring and wiring between the line, is running. faulty, incorrect or controller, and motor. grounded. Check motor armature current. If current exceeds controller rating, check for a mechanical overload or faulty motor. Also check shunt field current. Low shunt field current causes excessive armature current. Circuit board failure. Replace circuit board. 4. Motor does not Wiring faulty, incorrect, or Check all external wiring rotate. grounded. terminating in the controller. Controller fuse blow. Replace fuse with exact replacement. SPEED control pot failure Replace pot. RUN/STOP OR FORWARD/ Replace switch. STOP/REVERSE switch failure. Controller failure. Repair or replace controller. 5. Motor does not Low line voltage. Check for rated line voltage reach base speed. +/- 0%. Motor overloaded. See Indication. MAX SPD pot R0 Turn R0 clockwise until top misadjusted. speed is reached. Circuit board failure. Replace circuit board. 6. Unstable speed, Wrong calibration resistor(s) See Tables 4 and 5. inadequate regulation, removed. or low torque. Motor faulty. Check motor commutator and brushes. Refer to motor manufacturer s instructions. Circuit board failure. Replace circuit board. Table 6. Parts List Part Part Number Part Number Part Models RP, RPR Models RP, RPR Models RP, RPR Models RP, RPR Circuit Board 605 6055 SCR, SCR, SCR 6749 6749 Fuse, F, 0A 50V 6065 6065 Switch FWD/STOP/REV 679 679 Fuse Holder 6804 6804 Switch RUN/STOP 674 674 Pot, Speed 676 676 Transformer T 60868 60869 6 P-05-BG Doc. No. 85 Boston Gear Ratiotrol Manual

Warranty Boston Gear warrants that products manufactured or sold by it shall be free from defects in material and workmanship. Any products which shall within two () years of delivery, be proved to the Company s satisfaction to have been defective at the time of delivery in these respects will be replaced or repaired by the Company at its option. Freight is the responsibility of the customer. The Company s liability under this limited warranty is limited to such replacement or repair and it shall not be held liable in any form of action for direct or consequential damages to property or person. The foregoing limited warranty is expressly made in lieu of all other warranties whatsoever, express, implied and statutory and including without limitation the implied warranties of merchantability and fitness. No employee, agent, distributor, or other person is authorized to give additional warranties on behalf of Boston Gear, nor to assume for Boston Gear any other liability in connection with any of its products, except an officer of Boston Gear by a signed writing. Boston Gear 4 Hayward Street Quincy, MA 07 67-8-00 Fax: 67-479-68 www.bostongear.com An Altra Industrial Motion Company P-05-BG Doc. No. 85 07/07 Printed in USA