L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Similar documents
J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

K: bracket type. L: pole type

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Sheet-Steel Light Fittings Series 6014 / 6414

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Compact Sheet-Steel Light Fittings Series 6114

Linear luminaire with LED Series EXLUX 6002

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire with LED Series EXLUX 6002

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Tank Inspection Lights Series 6122

Compact Sheet-Steel Light Fittings Series 6114/1

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

7 Lighting Technology

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Floodlight LED Series 6525

Linear Luminaire with LED Series EXLUX 6402/2

Compact Sheet-steel Emergency Light Fitting Series 6118/1

LED Linear Luminaire Series EXLUX 6402

Floodlight LED Series 6125

Floodlight LED Series 6525

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Sheet Steel Emergency Light Fitting Series 6018

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVNL LED fitting - zones 2, & 22

Easy and safe installation

Floodlight Series 6121

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Linear fittings EVDL LED fitting - zones 21, & 22

7 Lighting Technology

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

11 Control Panels, Distribution Panels and Components

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

10 Load and Motor Switchgear

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

EX-REPAIR AND MAINTENANCE RECEPTACLES

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Emergency Luminaire with LED Series EXLUX 6409/1

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Operating Instructions

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

7 Lighting Technology

7 Lighting Technology

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Linear fluorescent luminaire LED V-CG-S

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

EX-RECESSED CEILING LIGHT FITTINGS

Linear fittings EVN Fluorescent fitting - zones 2 & 22

7 Lighting Technology

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Operating Instructions

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Floodlight Series 6521/4

EWE. Ex de. Cooling fins

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Safety Switches Series 8537

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Ex UPS standard Series 8265

Linear Luminaire for Fluorescent Lamps

Plug and Socket Devices SolConeX 16 A Series 8570

Lighting series JSNEVW Lighting series JLEDW LEUCHTEN 2011/09

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Lighting series JLZ Lighting series JELZ

A good connection. International approvals.

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

EXEL-L. Detail of the internal side. Transparent polycarbonate

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

EWE. Cooling fins. Ex de

PROTECTA III. Construction Tough glass reinforced polyester body

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

I Ex-safety switches I

Pendant Light Fitting IEC

FHL. Ex d. Body in aluminium

Battery Boxes Series 8316

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Transcription:

Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage: 8W x, 36W x, 8W x, 8W x, 36W x, 8W x. The glass tube stands 4J impact. Enclosure in copper-free aluminium, powder coated external surface, yellow. Electronic ballast, wide voltage range, rapid starting, stable performance, power factor.9. End of lamp life (EOL) rectification effect protection. Catalogue number logic BAY- x Mounting L: pole type X: ceiling type Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp Selection table Type/Ordering code Lamp wattage(w) Weight(kg) Type/Ordering code Lamp wattage(w) Weight(kg) BAY-8 x X 8 x 4.9 BAY-8 x X 8 x 9. BAY-8 x L 8 x.8 BAY-8 x L 8 x 9.6 BAY-36 x X 36 x 7.9 BAY-36 x X 36 x. BAY-36 x L 36 x 8. BAY-36 x L 36 x.6 BAY-8 x X 8 x 9.6 BAY-8 x X 8 x 7. BAY-8 x L 8 x. BAY-8 x L 8 x 7.7 Note: Products above include all the mounting accessories listed in Mounting Accessories & Spare Parts Table (see P/9-). Zones & /4 General Catalogue..

BAY Series Explosion-proof Technical data Explosion-proof light fittings for fluorescent lamp Explosion protection Gas explosion protection Certificates For gas explosion protection Conformity to standards Material Enclosure Glass tube Ballast Wire guard(optional) Exposed fastener Lamp Lamp Wattage(W) Rated voltage Earthing protection Degree of protection Ambient temperature Terminal Cable entries Single lamp Dual lamp Cable gland(optional) II G Ex d IIC T6 Gb LCIE 9 ATEX 346 EN 679-:7; EN 679-:7 IEC 679-:7; IEC 679-:7 BAY- x Copper-free aluminium, powder coated external surface, yellow. Toughened glass, stands 4J impact Electronic ballast Powder-coated carbon steel (white) or stainless steel Stainless steel PHILIPS T8 (supplied with the light fittings) 8 x 8 x 36 x 36 x 8 x 8 x 4V AC /6Hz M (internal & external earth bolt) IP66 - + 3 x. 4mm (L+N+PE) 3 x M x. Plug 4 x M x. Plug DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/. Dimensions Type L Size (mm) L Type L Size (mm) L BAY-8x 9 7 BAY-8x 9 7 BAY-36x 3 8 BAY-36x 3 8 BAY-8x 84 487 BAY-8x 84 487 Dimension drawings (all dimensions in mm) - subject to alteration BAY- x BAY- x General Catalogue.. /

BAY Series Explosion-proof Photometric data 8W x photometric data Rated luminous flux:lm; 8W x photometric data Rated luminous flux:lm; 64 33 33 74 63 334 6 6 33 6 3 6 6 99 37 6 6 7 9 3 7 77 6 7 7 33 7 3 6 8 8 3 37 8 48 3 9 8 3 3 8 4 49 9 4 97 9 4 44 4 86 We can provide lighting design and data by professional lighting software DIALUX based upon stimulated site situation on request. /6 General Catalogue..

BAY Series Explosion-proof Photometric data 36W x photometric data Rated luminous flux:lm; 36W x photometric data Rated luminous flux:lm; 333 8 698 77 33 49 699 3 33 6 3 694 6 48 38 6 88 687 6 48 34 7 63 686 7 36 34 7 9 683 7 8 3 34 8 7 3 67 8 37 3 38 8 3 67 8 4 36 9 4 68 9 4 97 4 64 We can provide lighting design and data by professional lighting software DIALUX based upon stimulated site situation on request. General Catalogue.. /7

BAY Series Explosion-proof Photometric data 8W x photometric data Rated luminous flux:4lm; 8W x photometric data Rated luminous flux:8lm; 8 46 3 93 6 377 87 6 349 9 6 748 6 3 88 6 668 498 7 79 88 7 49 7 8 7 4 3 49 8 43 3 6 8 49 3 48 8 3 7 8 4 46 9 4 984 9 4 447 4 9 We can provide lighting design and data by professional lighting software DIALUX based upon stimulated site situation on request. /8 General Catalogue..

BAY Series Explosion-proof Mounting types for light fittings with single lamp tube As reference to the installation of site X: ceiling type L: pole type (the pole is provided by user) Mounting accessories and spare parts table (light fittings with single lamp tube) Supplied according to the mounting type Mounting Accessories Ordering Weight type Name Qty Illustration code (kg) 363.7 X: ceiling type.connector SX. KSteel wire rope (with hook) Length:.7m(8W),.3m(36W),.6m(8W) SX.3~. G /4 Pipe clamp 364.6 L: pole type 36.6.Connector SX. KSteel wire rope (with hook) SX.3~. Note: Accessories not in the table shall be supplied by user. General Catalogue.. /9

BAY Series Explosion-proof Mounting types for light fittings with dual lamp tube As reference to the installation of site X: ceiling type L: pole type (the pole is provided by user) Mounting accessories and spare parts table (light fittings with dual lamp tube) Supplied according to the mounting type Mounting Accessories Ordering Weight type Name Qty Illustration code (kg) 363.7.Connector SX. X: ceiling type KSteel wire rope (with hook) Length:.7m(8W),.3m(36W),.6m(8W) SX.3. SX3.4 G /4 Pipe clamp 364.6 L: pole type 36.6.Connector SX. KSteel wire rope (with hook) SX.3. SX3.4 Note: Accessories not in the table shall be supplied by user. / General Catalogue..

BAY Series Explosion-proof Power connection and precautions (take 36W x as an example) Open the cover Loosen the tightening bolts on enclosure, screw out cover. (the two lamp tubes inside light fittings have been reliably connected; all lamp tubes are equippd with connecting terminals; correct connection for any terminal enables lamp tube power on). Power connection Screw out the seal plug at all inlet entries; pass cables through proper explosion-proof cable gland; connect the external wires L, N and PE to connecting bolts of internal connecting terminals reliably and ensure the inner electric clearance. After connection, lock the cable entry. Close the cover Check if the power connection is correct, then screw in the cover and screw down the tightening bolts. Lamp replacement and precautions (take 36W x as an example) Open the cover Loosen the tightening bolts on enclosure, screw out cover. Take out the lampwick === =Unscrew the M blots connecting lampwick support and enclosure, draw out the whole lampwick. === =Loosen connector of internal wires, draw out the whole lampwick. Replace the lamp tube == =Take out lamp tube: rotate the lamp tube at 9, then take out the lamp tube from the groove of lamp holder. == =Install the lamp tube: align the pins of lamp tube with groove and press them into the groove, ensuring good contact between lamp tube and lamp holder, then rotate the lamp tube at 9 to lock the lamp tube tightly. General Catalogue.. /