TX100/200-SERIES INSERTION TURBINE. T X / S E R I E S I N S E R T I O N T U R B I N E instru c tions TX101/201 TX115/215

Similar documents
TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

TX101/201 Insertion Turbine Instructions

TX115/215 Hot-tap Insertion Turbine Instructions

TX 115/215 Hot-tap Insertion Turbine Instructions

TX101/201 Insertion Turbine Instructions

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

EX100/200 Series. Insertion Magnetic Flow Meter Instructions. EX11x EX21x. EX15x EX25x PROUDLY MADE IN THE USA

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

SeaMetrics Flow Meters and Flow Computers

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

SES. Stainless Single-Jet Meter Instructions PROUDLY MADE IN THE USA

S-Series. Low Flow Meter Instructions SPX SPT. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

TURBINE METERS - WP Series

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Sidel Therm & CO 2 Counter Instruction & Installation Manual

Signet 2517 Brass Paddlewheel Flow Sensor * *

PSF50 Paddle flow switch

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

EX800-Series. Electromagnetic Flow Sensor Instructions PROUDLY MADE IN THE USA

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

FIXED DEPTH INSERTION METER INSTRUCTIONS

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Shop online at omega.com For latest product manuals: omegamanual.info

MODEL 1100 TURBINE FLOW METER

M SERIES Multi-Jet Cold Water Meter

Model 1100 Turbine Flow Meter

Flow Meter & Control Catalog

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

Hydro-Flow Model 2200 Installation and Operation Guide B

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

Low Profile Insertion Vortex

Hot Tap Insertion Vortex

RUN ACCUM. TOTAL STOP BAT LOW HIGH

PE202. Low Flow Magmeter Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

TURBINE FLOW METER SELECTION GUIDE

Hydro-Flow Model 3100

Compu-Flow. Electromagnetic Insertion Flow Meter. Compu-Flow EXM MAG

TABLE OF CONTENTS GENERAL INFORMATION

+GF+ SIGNET 2517 Adjustable Brass. Flow Sensor. Instruction Manual. Standard Sensor. Hot-Tap Sensor GEORGE FISCHER +GF+

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

EZ-IN Series Turbine Flowmeter

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

flow measurement solutions RIM10 series rotor insertion flowmeters

G2 Industrial Grade Meters

Liquid Turbine Flowmeter

MODEL 200 MULTI-JET FLOW METER

BI-DIRECTIONAL INSERTION METER

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Chapter Page. 1 Introduction Description 1

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

G2 SERIES INDUSTRIAL GRADE METERS

VERIS FLOW MEASUREMENT GROUP

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Turbine Flow Meter Series Turbine Meter USER MANUAL

TURBINE HOUSING. Owner s Manual Includes Aluminum, Brass and Stainless Steel Housings and ANSI Flange Fittings

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

Vortex Plate. Model VP General Specification. Product Features

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

MODEL 900 IMPELLER-TYPE FLOW METER

C.W. COX COMPANY a product line of Perfecto Products, Inc

MFM220 & MFM220DC Plastic-Bodied Magmeter

Positive Displacement Flowmeters GM020 series instruction manual

Model FVP General Specification. Flanged Vortex Plate. Product Features

TURBINE FLOW METER Installation and Operation Guide

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

TURBINE FLOW METER Installation and Operation Guide

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

MODEL 1100 TURBINE METER REPAIR KITS

SIGNET 7002 Vortex Flow Sensor ENGLISH

User s Guide FP-2540/FP Flow Sensors. Shop online at omega.com SM For latest product manuals:

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

INSTALLATION AND OPERATION

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

MODEL 200 MULTI-JET FLOW METER

PRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES

Signet 2552 Metal Magmeter

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Transcription:

INSERTION TURBINE instructions T X 1 0 0 / 2 0 0 - S E R I E S I N S E R T I O N T U R B I N E instru c tions AR CH IV ED TX100/200-SERIES TX101/201 TX115/215

Table of Contents General Information Features, Specifications...Page 1 Installation Piping, Immersion, Positioning the Meter...Page 2 Straight Pipe Recommendations... Page 3 Full Pipe Recommendations...Page 4 Fitting Installation, Meter Installation...Page 5 Proper Depth Setting, Dimension C, Pipe Wall Thickness...Page 6 Set-Up Connection, Calibration, K-Factors...Page 7 Operation Flow Range, Flow Rates...Page 8 Parts List Parts Exploded View...Page 9 Troubleshooting & Repair Troubleshooting, Repair, Rotor Replacement...Back TableS AND DIAGRAMS Features...P a g e 1 Specifications...Page 1 Positioning the Meter...Page 2 Piping...P a g e 2 Straight Pipe Recommendations... Page 3 Full Pipe Recommendations...Page 4 Meter Installation...Page 5 Depth Setting...P a g e 6 Pipe Wall Thickness...P a g e 6 Connection Diagram...P a g e 7 Parts Exploded View...P a g e 9 Parts List...P a g e 9 Rotor Replacement... B a c k

GENERAL INFORMATION The TX100/200-Series are adjustable depth insertion turbines that come in brass or 316 stainless models to fit 3 to 48 pipe. Installation fittings are standard 1-1/2" (101/201) or 2 (115/215) FNPT. Fittings such as saddles and weldolets may be purchased either locally or from Seametrics. Ruby bearings and a non-drag pickoff give these adjustable insertion turbine flow sensors a wide flow range and long life. A sensor detects the passage of miniature magnets in the rotor blades. The resulting square-wave signal can be sent for hundreds of feet without a transmitter, over unshielded cable. This signal can be connected directly to many PLC s and other controls without any additional electronics. FEATURES 3/4 diameter tubing for low insertion force 2 Adapter removes to mount hot-tap machine Full-port 2 ball valve for sensor removal Adapter fitting with 2 NPT threads SPECIFICATIONS* Power Source Sensor Pipe Size Materials Fitting Size Flow Range Accuracy Supply Voltage/Current Type Output Sinking Current External Pull-up Resistor Housing Sensor Body Rotor Shaft/Bearings Isolation Valve Maximum Temperature Maximum Pressure TX115/215 Locking collar Standard If desired, a modular system of electronics can be installed directly on the flow sensor or mounted remotely. The FT415 (battery powered) or FT420 (loop powered) provides digital rate and total display, as well as programmable pulse; the FT420 also provides a 4-20 ma analog output. The AO55 is a blind analog (4-20 ma) transmitter. Programmable pulse for pump pacing is available with the PD10. The hot-tap models (TX115/215) can be installed or serviced without shutting down the line by means of a 2 full-port isolation valve that comes with a nipple for installation on the pipe fitting. In most circumstances, no special tool is required. Modular electronics (optional) rate/total/pulse/4-20 ma blind 4-20 transmitter pulse divider 18 Foot Cable Rugged cast aluminum housing Compression nut for easy adjustment, secure locking Adapter fitting with 1-1/2 NPT threads Rotor housing Removable jewel bearings Rotor Micropowered (-04 Option) 6-40 Vdc/< 2 ma 3.5-16 Vdc/60 µa @ 3.5 Vdc Magnetoresistive Magnetoresistive Current Sinking Pulse Current Sinking Pulse 100 ma max 2 ma max 3-40 Vdc Supply Voltage TX101/115 TX201/215 3-12 (50-300mm) 12-35 (300-890mm) Cast aluminum Brass or 316 SS PVDF standard Nickel-bound tungsten carbide/ruby TX101/201 TX115/215 None Bronze (316SS optional) 1-1/2 NPT 2 NPT 0.5-30 feet/sec (0.15-9.14 meter/sec) +/-1.5% of full scale 200 F (93 C) 200 psi (14 bar) Note: For larger pipe sizes contact factory TX101/201 Insertion Force Cable 0.44 x pressure in pipe #22 AWG 3-con, 18 (6m); 2,000 (650m) maximum cable run Regulatory Mark (Standard Power Only) *Specifications subject to change. Please consult our website for the most current data (www.seametrics.com). Page 1

INSTALLATION An insertion flow sensor measures the velocity of flow at one point in the pipe; flow rate and total can be inferred from this one point. Accuracy is decreased by any factor which makes the flow at the measured point unrepresentative of the entire flow stream. This includes distorted flow patterns caused by upstream fittings too close to the sensor. The worst offenders are fittings that increase the flow on one side of the pipe, such as partially-opened gate or butterfly valves. Fluid moving in a pipe does not flow at the same velocity. Toward the center of the pipe, fluid moves faster than at the wall, and the relationship between the two changes as overall flow rate increases. This change in the velocity profile can result in non-linearity, which means that the K-factor (see page 7) that is correct for one flow rate may be incorrect for another. Recommended depth settings (see page 6) have been carefully chosen to minimize this source of error, and should be followed carefully, especially in the smaller pipe sizes. Piping. For best results, the TX sensor should be installed with at least ten diameters of straight pipe upstream and five downstream. Certain extreme situations such as partially-opened valves are particularly difficult and may require more straight diameters upstream. See Straight Pipe and Full Pipe recommendations on following pages. Immersion. The TX100/200-Series standard sensors are not designed for continuous underwater operation. If your 10 x Dia. FLOW 5 x Dia. meter may experience occasional temporary immersion, as in a flooded vault, a unit modified for immersion should be specified (Option -40). Positioning the Meter. Horizontal is the preferred installation orientation, since it improves low-flow performance slightly and avoids problems with trapped air. Bottom, top, and vertical pipe installaations are all acceptable if required by the piping layout. Fair (unacceptable if air is present) Best Fair (unacceptable if fluid contains sediment) CAUTION: These water meters are not recommended for installation downstream of the boiler feedwater pump where installation fault may expose the meter to boiler pressure and temperature. Maximum recommended temperature is 200ºF. Page 2

INSTALLATION STRAIGHT PIPE RECOMMENDATIONS (X = diameter) 10X 5X Reduced Pipe Two Elbows In Plane 10X 5X Two Elbows, Out Of Plane 20X 5X 20X 5X Expanded Pipe 30X Spiral Flow Propeller Meter 50X Swirling Flow Partially Open Butterfly Valve Page 3

INSTALLATION FULL PIPE RECOMMENDATIONS Possible Problem Better Installation Allows air pockets to form at sensor Possible Problem Better Installation Post-valve cavitation can create air pocket Possible Problem Air can be trapped Ensures full pipe Keeps pipe full at sensor Better Installation Allows air to bleed off Page 4

INSTALLATION TX101/201 INSTALLATION Fitting Installation. TX101/201 sensors come with a 1-1/2 male NPT pipe thread adapter fitting. Any fitting that provides the matching NPT female thread may be used. Installation procedure compensates for fitting height differences. Cut a minimum 1-3/4 hole in the pipe. If possible, measure the wall thickness and write it down for use in depth setting. Then install the threaded fitting (saddle, weldolet, etc.) on the pipe. Meter Installation. Loosen the compression nut so that the adapter slides freely. Pull the meter fully upward and finger-tighten the compression nut. Using a thread sealant, install the adapter in the pipe fitting. Do not overtighten. Now loosen the compression nut, lower the meter to the appropriate depth setting (see diagram and instructions that follow). Caution: Do not allow the meter to fall into the pipe uncontrolled, as this may damage the meter. Be sure flow is in the direction of the arrow on the housing. Tighten compression nut fully. TX115/215 INSTALLATION Hot tap TX meters are designed to be installed and serviced without depressurizing the pipe. Fitting Installation. The TX115/215 sensors have a 2 NPT thread for compatibility with the 2 isolation valve. Any fitting that provides matching NPT female thread may be used. The installation procedure compensates for differences in fitting height. If initial installation is performed on an unpressurized pipe, cut a minimum 1-3/4 hole in the pipe. If possible, measure the wall thickness and write it down for use in depth setting. Then install the threaded fitting (saddle, weldolet, etc.) on the pipe. If it is necessary to do the initial installation under pressure, any standard hot tap drilling machine with 2 NPT adapter, such as a Transmate or a Mueller, can be used. Ordinarily, it is not necessary to use an installation tool, since the small-diameter tube can be controlled by hand at all but the highest pressures. Meter Installation. Remove the sensor unit from the valve assembly. Using a thread sealant, install the valve assembly on the pipe fitting. If the initial installation is a pressure ( hot ) tap, remove the 1-1/2 x 2 adapter bushing at the back of the valve. Thread the tapping machine on, open the valve, and tap using a minimum of 1-3/4 or maximum 1-7/8 cutter. After retracting the machine and closing the valve, reinstall the flow sensor. When the sensor is secure, open the valve and adjust depth setting (see diagram and instructions that follow). Be sure flow is in the direction of the arrow on the housing. Tighten locking collar and compression nut fully. Compression nut Adapter fitting with standard 1-1/2" NPT threads Compression nut Locking collar 2 adapter removes to mount hot-tap machine Full-port 2 ball valve allows sensor removal Standard 2 NPT threads TX115/215 Sensor Removal Page 5

INSTALLATION Table 1: Pipe Wall Thickness PVC/Steel Sch. 40 "D" Proper Depth Setting. It is important for accuracy that the sensor be inserted to the correct depth into the pipe. 1. Please visit www.seametrics.com and select the K-factor Calculator located on the lower left of the homepage to find dimension 'D' (insertion depth setting) above. PVC/Steel Sch. 80 Stainless Steel (10S) Stainless Steel (40S) Copper Tubing (Type L) 2. Measuring from the outside of the pipe to the joint in the housing, as shown in the diagram above, adjust the sensor to Dimension D and hand-tighten compression nut. 3. Align the conduit housing with the centerline of the pipe, as shown. Be sure the arrow on the housing points in the direction of flow. strain relief FLOW 4. Check Dimension D one more time. 5. Tighten the compression nut fully. NOMINAL Pipe Size 3 4 6 8 10 12 14 16 18 20 24 30 36 0.216 0.237 0.280 0.322 0.365 0.406 0.438 0.500 0.562 0.593 0.687 0.300 0.337 0.432 0.500 0.593 0.687 0.750 0.843 0.937 1.031 1.218 0.120 0.120 0.134 0.148 0.165 0.180 0.188 0.188 0.188 0.218 0.250 0.312 0.312 0.216 0.237 0.280 0.322 0.365 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.090 0.110 0.140 0.200 0.250 0.280 Record Your Settings Once you have the meter set up and operational, it is important to record your meter setttings and save them for future reference. K-Factor Insertion Depth (Dim. D) Copper Tubing (Type K) Brass Pipe Duct. Iron (Class 52) 0.109 0.134 0.192 0.271 0.338 0.405 0.219 0.250 0.250 0.312 0.365 0.375 0.280 0.290 0.310 0.330 0.350 0.370 0.390 0.400 0.410 0.420 0.440 0.470 0.530 Page 6

SET-UP Connection. Sensors are supplied with 18 ft. of cable. For sensors with no additional electronics, see diagram for color coding. For sensors with on-board electronics, see the manual accompanying the electronics module. RED (+) 5-24 Vdc WHITE (signal) BLACK (-) Power 18' cable standard Calibration ( K-Factor ). In order to properly process pulses from the flow sensor, a number must be entered into the control to which the sensor is connected. This number, called the K-factor, is the number of pulses the sensor puts out per unit of fluid passing through the pipe. It is normally provided for Seametrics sensors in pulses per gallon (see Table 3, below). These numbers are based on extensive testing, which has shown close agreement between different TX sensors in the same installation. Most K-factor error can be attributed to installation variables, such as depth setting and fitting configuration. It is possible to field calibrate a sensor by catching the fluid in a measured container and comparing with the number of pulses recorded. (To record individual pulses, set the K-factor on the control to 1.00.) This is especially desirable if the installation has less than the recommended length of straight pipe upstream of the sensor. For detailed intructions on field calibration, please refer to the technical bulletin on our website (www.seametrics.com/pdf/lt-13276-a.pdf). Page 7

OPERATION Flow Range. These sensors are designed to operate at flow velocities of 0.5 to 30 feet per second (see Table 4, below). If erratic readings are encountered at low flows, check the chart to see if flow is below minimum for the pipe size. The standard shaft and bearings should have a long life at continuous high flow. TABLE 4: Flow Rates converted from Feet/Sec to Gallons/Minute at various velocities: Schedule 40 pipe Feet / Sec (0.2) (0.5) (1.0) (2.0) (5.0) (10.0) (20.0) (30.0) Nominal pipe size 3" 4" 5" 6" 8" 10" 12" 16" 24" 36" 38" 48" 4.6 7.9 12.5 18 31.2 49.1 70 125 259 600 670 1090 11.5 19.8 31.2 45 78 123 174 275 627 1460 1770 2820 23 39.7 62.4 90 156 246 349 551 1250 2910 3530 5640 46.1 79.4 125 180 312 492 698 1100 2510 5830 7070 11280 115 198 312 450 780 1230 1740 2750 6270 14570 17670 28200 230 397 624 900 1560 2460 3490 5510 12530 29140 35350 56400 461 794 1250 1800 3120 4920 6980 11020 25060 58270 70700 112800 691 1190 1870 2700 4680 7370 10470 16520 37600 87410 106050 170000 Page 8

PARTS LIST 4 1 TX101/201 5 TX 101/201 Parts 1 Upper housing assembly 30475 2 Housing Gasket 26211 2 3 7 8 9 10 11 7 12 13 6 TX115/215 17 18 19 20 3 Lower housing Not Field Replaceable 4 Housing screw assembly 26229 (4 required) 5 Plug, steel 26073 6 Strain relief 07655 7 Sensor w/cable 26310 (Standard - FT420) 29953 (Micropower - FT415) 8 Tube Not Field Replaceable 9 Compression nut 10 Compression Ferrule 26065 11 Adapter fitting 12 Rotor housing O-ring 16454 13 Rotor housing 14a 14b Jewel bearing assembly (for carbide shaft) Jewel Bearing Assembly (for ceramic shaft) 15 Turbine Rotor assembly 16 Rotor repair kit (consists of #15 & #16) 14199 (Brass) 15064 (SS) 30998 (Brass) 30999 (SS) Before Jan 1, 2011 After Jan 1, 2011 25977 (Brass) 33023 (Brass) 25978 (SS) 33024 (SS) 25901 (2 required) 16710 (2 required) TX 115/215 Parts (hot tap) All part numbers are the same except those below 17 Locking Collar 18 Adapter fitting O-ring 26029 Before Jan 1, 2011 After Jan 1, 2011 25946 (Polypro) 33015 (Kynar) 25947 (Kynar) Before Jan 1, 2011 After Jan 1, 2011 25930 (Poly/Carbide) 33087 (Kynar/Carb) 25945 (Kynar/Ceramic) 14190 (Brass) 15170 (SS) 14a 19 Adapter, hot tap 26130 (Brass) 26131 (SS) 14b 16 15 20 Valve assembly (inlcudes Adapter, #20) 14225 (Brass) 15225 (SS) Page 9

TROUBLESHOOTING and REPAIR Troubleshooting Caution! Never attempt to remove a flow sensor when there is pressure in the pipe. Loosen the compression nut slowly to release any trapped pressure. If fluid sprays out when removing the sensor, stop turning and depressurize the pipe. Failure to do so could result in the sensor being thrown from the pipe, resulting in damage or serious injury. The flow sensor has only one moving part, the rotor. If this is turning properly and there is no signal, the Hall-effect sensor is not operating properly. To check the signal, apply 12 Vdc regulated* power to the red (+) and black (-) leads. Set a multimeter to voltage reading. Put the positive multimeter lead on the red wire and the negative lead on the white wire. Slowly turn the rotor. Voltage reading should swing between +12 Volts and 0 Volts as the rotor turns. If it does not, the Hall effect sensor is not working properly. Checking for continuity is not a useful test of these sensors. *NOTE: An unregulated power supply can exceed max voltage of micro powered sensor (gray cable) and damage sensor. Repair All Seametrics flow sensors are repairable, and can be returned to the factory or distributor for repair. Please first obtain a Return Material Authorization (RMA) number. Rotor Replacement.* Rotors are easily field-replaced. Shaft and rotor are a single unit, and are not replaced separately. If replacement is due only to normal shaft wear, bearing replacement is probably not necessary. If the rotor has been damaged by impact, the bearings should also be replaced. Rotor and bearings can be ordered as a kit (see parts listing). Follow these steps: 1. Unscrew the threaded bearing housings to expose the shaft ends. If bearings are being replaced, back them completely out. 2. Remove the rotor. Put the new rotor in its place. 3. Thread in one bearing housing part way, then the other. Take care to start the end of the shaft into the bearing hole before tightening further. 4. Screw in bearing housings until they bottom. Note: Do not use excessive force. 5. Check for free spin. Blowing lightly on the rotor should result in it spinning rapidly and coasting to a smooth stop. Turbine Rotor Shaft Bearing* Housing *Note: Described here is the rotor/shaft/bearing configuration for the carbide shaft model. On ceramic shaft models the shafts are in the screws and the bearings are in the rotor. Follow the same basic procedure above. Seametrics Incorporated 19026 72nd Avenue South Kent, Washington 98032 USA (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 www.seametrics.com LT-65200050-D 1/4/2011