Brochure. Motor protection and control DRAS enclosed direct-on-line starters

Similar documents
Manual motor starter MS116

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Manual motor starter magnetic only MO325

Mini contactors B6, BC6 with 3 pole

Electronic overload relays EF205 and EF370

Manual motor starter MS132

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Manual motor starter MS116

Manual motor starter MS132

Thermal overload relay TF140DU and TF140DU-V1000

Manual motor starter MS132

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starters Overview and benefits

Electronic overload relay EF65, EF96 and EF146

Thermal overload relay TF65 and TF96

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

Panorama. Contactors Motor protection Accessories

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Mini Contactors Applications and Segments

Motor Starting Solutions Open Type Version, in Kit Form

DBL distribution blocks 3x1 pole

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Thermal Overload Relays

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Selective main circuit breakers S 750 series Technical Data

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS50-PE Screw Clamp Terminal Blocks Ground

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZK4-PE PI-Spring Terminal Blocks Ground

ZS4-PE Screw Clamp Terminal Blocks Ground

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS35 Screw Clamp Terminal Blocks Feed-through

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZK6 PI-Spring Terminal Blocks Feed-through

ZP2.5-PE Spring Terminal Block Ground

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

ZS6 Screw Clamp Terminal Blocks Feed-through

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

ZS4-PE Screw Clamp Terminal Blocks Ground

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Short form catalogue Motor protection and control Manual motor starters

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Contactors : Wide band AC / DC operated

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ABB i-bus KNX DG/S x DALI-Gateway Basic

ZP2.5-4P Spring Terminal Block Feed-through

Panorama. Softstarters The complete range

ASL09..S 3-pole Contactors - Spring Terminals

Motor Starter Reverse MSR22-FBP

Product information. ECOSS Electronic compact starter for wound rotor drives

AE 9... AE 40 Contactors NE... Contactor Relays

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

Surge arrester POLIM-H.. ND

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

ZS10 Screw Clamp Terminal Blocks Feed-through

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Data Sheet Manual Motor Starters Ex9SN Series

Surge arrester POLIM-C.. HD

ZS4 Screw Clamp Terminal Blocks Feed-through

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

EMPAC Metal enclosed capacitor bank for wind applications

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands

Surge arrester POLIM-H..SD

Valve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat

AF40... AF96 3-pole contactors Technical data

TriLine PowerModules Overview with Planing Examples

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Transcription:

Brochure Motor protection and control DRS enclosed direct-on-line starters

DRS09 DRS16 enclosed direct-on-line starters 4 to 7.5 kw, protected by thermal overload relays C or DC operated DRS + T16 to be ordered separately 1SBC133003V0014 Description Enclosed direct-on-line (DOL) starters are used for controlling 3-phase asynchronous motors up to 690 V C. Each starter is delivered assembled and wired. It contains: IP65 compact plastic enclosure with double insulation, equipped with: --1 green flush "I" ON button and 1 red protruding "O" OFF/RESET button --2 quarter-turn, quick fastening screws and a base with 6 cable inlets and outlets via knockouts. 1 S or SL 3-pole contactor with holding contact 1 PE and 1 neutral terminal. 3 versions of control supply wiring are available: phase-to-phase, separate supply or phase-to-neutral. T16 thermal overload relay has to be ordered separately and choses according to motor's nominal current (see table below). DRS, DRSL enclosed DOL starters IEC - C-3 Rated control circuit Control supply Type Order code Weight Rated operational voltage wiring power max. Uc Pkg Other control 220 V 400 V 500 V current (1 pce) voltages see 230 V θ 40 C voltage code table 240 V Ue=400 V kw kw kw V 50/60 Hz V DC kg C operated with S 3-pole contactors 2.2 4 4 9 24 - Separate supply DRS09-20S 1SBK104235R2000 0.650 230 - Phase-to-neutral DRS09-26N 1SBK104135R2600 0.650 240 - Phase-to-neutral DRS09-27N 1SBK104135R2700 0.650 400 - Phase-to-phase DRS09-28P 1SBK104035R2800 0.650 415 - Phase-to-phase DRS09-29P 1SBK104035R2900 0.650 3 5.5 5.5 12 24 - Separate supply DRS12-20S 1SBK114235R2000 0.650 230 - Phase-to-neutral DRS12-26N 1SBK114135R2600 0.650 240 - Phase-to-neutral DRS12-27N 1SBK114135R2700 0.650 400 - Phase-to-phase DRS12-28P 1SBK114035R2800 0.650 415 - Phase-to-phase DRS12-29P 1SBK114035R2900 0.650 4 7.5 7.5 15.5 24 - Separate supply DRS16-20S 1SBK124235R2000 0.650 230 - Phase-to-neutral DRS16-26N 1SBK124135R2600 0.650 240 - Phase-to-neutral DRS16-27N 1SBK124135R2700 0.650 400 - Phase-to-phase DRS16-28P 1SBK124035R2800 0.650 415 - Phase-to-phase DRS16-29P 1SBK124035R2900 0.650 DC operated with SL 3-pole contactors 2.2 4 4 9-24 Separate supply DRSL09-81S 1SBK104335R8100 0.700-48 DRSL09-83S 1SBK104335R8300 0.700 3 5.5 5.5 12-24 Separate supply DRSL12-81S 1SBK114335R8100 0.700-48 DRSL12-83S 1SBK114335R8300 0.700 4 7.5 7.5 15.5-24 Separate supply DRSL16-81S 1SBK124335R8100 0.700-48 DRSL16-83S 1SBK124335R8300 0.700 T16 2CDC231009V0013 Empty enclosure with push-button 1SBC133001V0014 T16 thermal overload relays to be ordered separately Setting range Short-circuit protective device Trip class Type Order code Weight (1 pce) kg 0.10 0.13 0.5, Fuse type T 10 T16-0.13 1SZ711201R1005 0.100 0.13 0.17 1.0, Fuse type T T16-0.17 1SZ711201R1008 0.100 0.17 0.23 T16-0.23 1SZ711201R1009 0.100 0.23 0.31 T16-0.31 1SZ711201R1013 0.100 0.31 0.41 2.0, Fuse type gg T16-0.41 1SZ711201R1014 0.100 0.41 0.55 T16-0.55 1SZ711201R1017 0.100 0.55 0.74 4.0, Fuse type gg T16-0.74 1SZ711201R1021 0.100 0.74 1.00 6.0, Fuse type gg T16-1.0 1SZ711201R1023 0.100 1.00 1.30 T16-1.3 1SZ711201R1025 0.100 1.30 1.70 10.0, Fuse type gg T16-1.7 1SZ711201R1028 0.100 1.70 2.30 T16-2.3 1SZ711201R1031 0.100 2.30 3.10 T16-3.1 1SZ711201R1033 0.100 3.10 4.20 20.0, Fuse type gg T16-4.2 1SZ711201R1035 0.100 4.20 5.70 T16-5.7 1SZ711201R1038 0.100 5.70 7.60 35.0, Fuse type gg T16-7.6 1SZ711201R1040 0.100 7.60 10.0 T16-10 1SZ711201R1043 0.104 10.0 13.0 40.0, Fuse type gg T16-13 1SZ711201R1045 0.104 13.0 16.0 T16-16 1SZ711201R1047 0.104 Empty enclosure with push-button - - - 6S-12VRS 1SBN101035R1000 0.394 To be completed with S or SL contactor, T16 thermal overload relay and MCB-10B (1SF611610R2001) contact block. 1SBC133001S0201 BB DRS enclosed direct-on-line starters 1

DRS09 DRS16 and DRSL09 DRSL16 enclosed direct-on-line starters Control supply wiring versions L1 L2 L3 N V 1 L1 3 L2 U 5 L3 DRS..S, DRSL..S DRS..N DRS..P Separate supply Phase-to-neutral Phase-to-phase 1 1 1 I Uc DRS 2 Uc = Us 2 Uc = V 2 Uc = U O R 2 T1 4 T2 6 T3 Wiring diagram RESET M TEST STOP Power circuit 2 1 1/L1 3/L2 96 95 98 97 6/T3 6/T3 5/L3 14 13 1/L1 3/L2 1-phase 6/T3 6/T3 5/L3 14 13 DRS..P DRS..N DRS..S DRS..S DRS..N DRS..P : 5/L3 Us Us N RESET : 3/L2 STOP M I -3-4 95 96 2 1 14 13 + RESET STOP - M I -3-4 2-1+ 14 13 96 95 C local control DRS09... DRS16 + T16 DC local control DRSL09... DRSL16..S + T16 Main dimensions mm, inches 92 3.62" 131.5 5.18" 126.5 4.98" 7.5 0.30" 5.5 0.22" M5 Cable inlets Cable outlet Enclosure top Enclosure back Enclosure bottom 2 x ø 20.5/25.5 mm 2 x ø 20.5 mm 2 x ø 20.5/25.5 mm 2 x ø 0.81/1.00" 2 x ø 0.81" 2 x ø 0.81/1.00" 171.5 6.75" 160 6.30" ø 20.5mm - ø 0.81" for ISO M20 ø 25.5mm - ø 1.00" for ISO M25 DRS09, DRS12, DRS16 DRSL09, DRSL12, DRSL16 5.5 0.22" M5 7.5 0.30" 1SBC133002S0201 2 BB DRS enclosed direct-on-line starters

Voltage code table DRS09... DRS16 and DRSL09... DRSL16 enclosed DOL starters Type DR S16-26N S contactors C coil code 50 Hz 60 Hz SL contactors DC coil code Control supply wiring 20 S 24 V 24 V 81 S 24 V S Separate supply 21 S 42 V 42 V 83 S 48 V 22 S 48 V 48 V 16 N - 120 V N Phase-to-neutral 23 N 110 V 110 V 24 N 115 V 115 V 25 N 220 V 220 V 26 N 230 V 230 V 27 N 240 V 240 V S SL Contactor type C operated DC operated 13 P 380 V 380 V P Phase-to-phase 17 P - 277 V 28 P 400 V 400 V 29 P 415 V 415 V 1SBC133003S0201 BB DRS enclosed direct-on-line starters 3

Contact us BB France Low Voltage Products Division 3, rue Jean Perrin F-69687 Chassieu cedex / France BB STOTZ-KONTKT GmbH Eppelheimer Straße 82 D-69123 Heidelberg / Germany You can find the address of your local sales organisation on the BB home page Note We reserve the right to make technical changes or modify the contents of this document without prior notice. BB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of BB. Copyright 2013 BB - ll rights reserved 1SBC100185C0201 - Printed in France (11.2013 PDF) www.abb.com/lowvoltage