SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

Similar documents
SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

CPAF SERIES CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III Snider Road, Mason, OH Telephone:

HDBI FEATURES. Visit us at for more information. NOTE: HDBI-330 and HDBi-360 housings are not rotatable or reversible.

PBS SERIES FABRICATED STEEL PRESSURE BLOWERS Snider Road, Mason, OH Telephone:

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

Defining Innovation. backward curved FANs

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Turbo Pressure Blowers

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Twin City Fan & Blower

Good Enough Never Is. Plug Fan SERIES 12

Twin City Fan & Blower

SECTION CENTRIFUGAL HVAC FANS

SERIES CAST ALUMINUM PRESSURE BLOWERS

FRP Fans: CLUB Series Performance and Technical Information

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

PEERLESS ELECTRIC INDUSTRIAL FANS

Centrifugal Utility Fans - SFD/SFB

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

VANEAXIAL & TUBEAXIAL FANS

SERIES CAST ALUMINUM PRESSURE BLOWERS

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

BACKWARD INCLINED BI AND BIA INDUSTRIAL SWSI CENTRIFUGAL FANS

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

Vibration Isolators (6) Galvanized Wheel. Sealed Ball Bearing. Standard Duct Size Inlet Ring

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

SECTION AXIAL HVAC FANS

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012

LM & LMF SERIES CAST ALUMINUM VOLUME BLOWERS Snider Road, Mason, OH Telephone: Cat. No. LM-308 Supersedes LM-702

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

& 12" 96" / TABD CATALOG

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

TUBULAR CENTRIFUGAL INLINE FANS

Twin City Fan & Blower

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

Air Moving Solutions. AIRFOIL fans

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

TURBO PRESSURE BLOWERS

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

Twin City Fan & Blower

Industrial Mini Vent Sets

Twin City Fan & Blower

AXIFAN VANEAXIAL FANS

Defining Innovation. INDUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011

Mixed Flow Inline Fan, Model MFSI

BACKWARD CURVED HIGH PRESSURE FANS

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW CATALOG 1260 APRIL 2015

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

Centrifugal Plenum Fan

Fixed Pitch Vane Axial Fan

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD

DESIGN GUIDELINES FANS PAGE 1 of 7

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

QB CENTRIFUGAL FANS I7FAD BULLETIN SOB 108

COMMERCIAL DUTY PLENUM FANS

SECTION HVAC POWER VENTILATORS

Air Moving Solutions. axifan adjustable blade vaneaxial fans

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW

BULLETIN 912-A. February 1999 HIGH PRESSURE BLOWER. Model HPB Direct Drive/Belt Driven

Cyclone Custom Centrifugal Fans

Square Inline Fans with Multi-Directional Discharge

Inline and Roof Mounted Fans

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application

BULLETIN BCHP 100 May High Pressure Backward Curved Fans

Turning Air Into Solutions. BACKWARD CURVED HIGH PRESSURE FANS MODEL BCS

SQUARE INLINE CENTRIFUGAL FANS

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

ARRANGEMENT 4/4F/4H/4V SINGLE-WIDTH ACOUSTAFOIL/PLR FANS

Transcription:

OEM and Industrial Air Handling Specialist SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more information. Cat. No. SQAF-908 Supersedes SQAF-90

A Company That Stands Behind Its Product Since the founding of Cincinnati Fan in 196, the company s mission has been to provide quality products at competitive prices, backed by dependable service. This mission is carried out by specializing in the market for industrial air handling products up to 12 HP. But specialization does not mean the product line is small. Cincinnati Fan offers a wide variety of standard and customized products, production flexibility, and customer responsiveness. Cincinnati Fan has over 10 experienced sales engineers across the U.S. and Canada ready to serve your air handling needs. Cincinnati Fan can provide: Technical evaluation for correct performance conditions. Review of air stream and ambient conditions that require special attention. Selection of proper components to meet required design specifications. Selection of proper accessories. System analysis for proper fan design. Cincinnati Fan operates in a modern facility specifically designed for world class manufacturing enabling us to build most standard products to order, including accessories, and ship within to 1 working days. With support like this, you can be sure your Cincinnati Fan product will be well-built and will provide maximum dependability and longevity. Visit us at www.cincinnatifan.com for more information. SPECIFICATIONS FOR SQAF SERIES Airfoil bladed fans shall be Cincinnati model SQAF, Size, Class, Arrangement. Capacity:, Static Pressure at standard conditions. Operating conditions: F, Ft. Altitude. Wheels shall have airfoil blades and are designed to meet specified conditions for each class. Wheels shall be dynamically balanced to assure smooth operation. Shafts shall be turned, ground and polished steel (or stainless steel). All fans shall be test run at the factory before shipping. Housings shall be continuously welded and supported to prevent housing pulsation at all conditions. Inlet bell shall be designed for smooth air entrance into wheel for maximum efficiency. All bearings shall be grease-lubricated, heavy-duty, self-aligning ball bearing. V-belt drive shall be selected for a minimum of 1.3 times nominal horsepower. Before painting, all steel parts shall be cleaned by detergent wash, phosphatized and painted with machine gray enamel. The following accessories shall be included: (See page for available accessories). 2

EFFICIENCY OF AIRFOIL WHEELS vs. BACKWARD INCLINED WHEEL Airfoil wheels provide the highest efficiency of all centrifugal fan designs. The curve overlays at right comparing an SQAF-220 and SQBI-220 illustrates a % increase in static efficiency for the airfoil design versus the backward inclined design in the normal selection range. This benefit results in lower brake horsepower consumption and a reduction in sound levels of 2-6 dba. SQAF-220 SQBI-220 ADVANTAGES OF DIRECT DRIVE ARRANGEMENT #4 COST Lower initial cost plus lower maintenance cost (no v-belt drives, fan shaft or bearings to replace). RATINGS More ratings available. All sizes offered with two wheel diameters and fan housing widths from 0% to 0% in % increments. COMPACT Requires less space. MOUNTINGS Four discharge positions and two rotations (CW or CCW) plus fans can be mounted horizontally (Maximum 600 pound motor). LESS WEIGHT Requires less supporting structure. CONSTRUCTION Solidly built with continuously welded housings and mounting holes in all support flanges. All fans are mechanically run tested prior to shipment to ensure the balance of the assembled unit. 3

SQAF, ARRANGEMENT #9 FEATURES A F L G H I B E J K C D L G O N P M Q R C A) Heavy-duty, cast iron wheel hub. B) Inlet bell designed for smooth air entrance into wheel for maximum efficiency. C) Inlet and motor side plate braces for added rigidity. D) Slip collar inlet (optional) for ductwork connection. Flanged inlet also available. See page. E) Airfoil blades fabricated of high strength steel to assure long lasting, efficient operation. F) Steel pipe support rods between inlet and motor side plates for extra rigidity and smooth operation. G) Lifting lugs for ease of mounting by hoist or crane in hard to reach areas. H) Heavy duty belt guard, painted safety yellow, standard on arrangement #9. I) Motor mounting base extended so fan can be built in Up Blast Discharge position with motor still on top. J) Inboard bearing inspection opening on 2 sides. K) Steel angle support legs for shipping. Remove after mounting is completed. 4 L) Drive side plate braces for added rigidity. M) Drive side plate can be disconnected to rotate housing in field without removing wheel or disturbing bearings & drives. Also, entire motor/bearing support structure and wheel can be removed from installation without having to disconnect inlet and/or discharge duct work. N) Turned, ground and polished shafting assures smooth operation. A rust preventative coating is applied prior to shipment. O) Four motor adjustment bolts for easy adjustment and alignment of belt tension. P) Heavy-duty, self-aligning, relubricatable, ball bearings in cast iron pillow blocks are standard. Bearings selected for optimal performance depending on fan size and class with an L life of 30,000 hours minimum. Q) Bearing grease lines extend to grease fittings (not shown) outside of bearing base for easy lubrication of fan bearings when needed. R) Bearing base is heavy steel construction with supports to maximize rigidity and assure long equipment life.

OPTIONAL ACCESSORIES Inlet Collar Inlet collar for slip fit connection to duct work. Inlet Flange Flanged inlet for bolted connection to duct work. Flange drilled with our standard hole pattern, see page 23. Outlet flange is standard and drilled per our standard hole pattern, see page 23. Undrilled flanges available at additional cost and extended delivery. Inlet Vane Control Inlet vane offers more efficient flow control compared to outlet damper. Manual control is standard. Automatic control is optional. Requires inlet collar and flange for mounting to fan. Drain 3 4" NPT, Female pipe coupling with plug. Welded to lowest point on inlet side plate. Inlet & Outlet Guards Inlet guard is welded, formed wire. Outlet guard is expanded metal. Guards are in accordance with OSHA. Inspection Door Bolted or quick-release doors positioned as specified on scroll. Rubber gasket standard up to 20 F (121 C). Ceramic fiber gasket standard at temperatures above 20 F (121 C). Outlet Damper Outlet damper provides low cost flow control. Opposed blade manually controlled construction is standard. Also available with automatic controllers. Shaft Seal Teflon shaft seal good to 400 F. (204 C.). Ceramic fiber gasket material with steel cover plate above 400 F. (20 C.).

SPARK-RESISTANT CONSTRUCTION For AMCA Type A or B spark resistant construction, please contact our local Cincinnati Fan sales representative. Type C: Consists of aluminum inlet bell and aluminum plate on drive side of the fan. Maximum Temperature is the same as for high temperature construction below for each arrangement.! WARNING The use of aluminum or aluminum alloys in the presence of steel which has been allowed to rust requires special consideration. Research by the U.S. Bureau of Mines and others has shown that aluminum impellers rubbing on rusty steel may cause high intensity sparking. The use of the above Standard in no way implies a guarantee of safety for any level of spark resistance. Spark-resistant construction also does not protect against ignition of explosive gases caused by catastrophic failure or from any airstream material that may be present in a system. HIGH TEMPERATURE CONSTRUCTION Standard Construction: Arrangement 9 suitable to 300 F. (149 C.) Arrangement 4 suitable to 200 F. (93 C.) 301-400 F. ( -204 C.) Construction: Standard fan with heat slinger. Arrangement 9 only. 401-600 F. (20-316 C.) Construction: Standard fan with heat slinger, high temperature shaft seal, gasketing and paint. Arrangement 9 only. 601-0 F. (31-398 C.) Construction: Standard fan with heat slinger, 316SS fan shaft, high temperature shaft seal, gasketing and paint. Arrangement 9 only. TEMPERATURE RANGE Degrees Degrees F. C. Up to 1 16-200 201-300 301-400 401-00 01-600 601-00 01-0 Up to 80 81-93 94-149 -204 20-260 261-31 316-31 32-398 MAXIMUM RPM REDUCTION FACTOR 0% 2% 4% % 11% 1% 20% 30% AIR TEMP. F 0 40 0 80 0 120 140 160 180 200 20 300 30 400 40 00 0 600 60 00 0 6 TEMPERATURE - ALTITUDE CONVERSIONS ALTITUDE IN FEET ABOVE SEA LEVEL 0 00 2000 3000 4000 000 6000 000 8000 9000 000.8.91.94.98 1.01 1.0 1.09 1.13 1.1 1.22 1.26.94.98 1.02 1.06 1. 1.14 1.19 1 23 1.28 1.32 1.36 1.00 1.04 1.08 1.12 1.16 1.20 1.2 1.30 1.3 1.40 1.4 1.02 1.06 1. 1.14 1.19 1.23 1.28 1.33 1.38 1.43 1.48 1.06 1. 1.14 1.19 1.23 1.28 1.33 1.38 1.43 1.48 1.4 1.09 1.14 1.18 1.23 1.28 1.32 1.38 1.43 1.48 1.3 1.8 1.13 1.18 1.22 1.2 1.32 1.3 1.42 1.48 1.4 1.8 1.6 1.1 1.22 1.26 1.31 1.36 1.42 1.4 1.3 1.9 1.64 1.0 1.21 1.26 1.30 1.36 1.41 1.46 1.2 1.8 1.64 1.0 1. 1.2 1.29 1.34 1.40 1.4 1.1 1. 1.63 1.69 1. 1.81 1.34 1.39 1.4 1.0 1.6 1.62 1.68 1.4 1.82 1.88 1.94 1.43 1.49 1. 1.61 1.6 1.4 1.80 1.8 1.94 2.00 2.08 1.3 1.9 1.6 1.2 1.8 1.8 1.92 2.00 2.0 2.14 2.22 1.62 1.69 1. 1.82 1.89 1.96 2.04 2.12 2.20 2.2 2.3 1.2 1.9 1.86 1.93 2.00 2.08 2.16 2.24 2.33 2.41 2.0 1.81 1.88 1.96 2.03 2.11 2.19 2.28 2.36 2.46 2.4 2.62 1.91 1.98 2.06 2.14 2.22 2.30 2.40 2.49 2.8 2.68 2. 2.00 2.08 2.16 2.24 2.33 2.42 2.0 2.61 2.1 2.80 2.90 2. 2.18 2.26 2.3 2.44 2.4 2.63 2.4 2.84 2.94 3.04 2.19 2.2 2.36 2.46 2. 2.6 2. 2.86 2.9 3.06 3.18 2.28 2.3 2.4 2.6 2.66 2.6 2.8 2.98 3. 3.19 3.31 Fan performance tables are developed using standard air which is 0 F., 29.92" barometric pressure and.0 Ibs. per cubic foot. Density changes resulting from temperature or barometric pressure variations (such as higher altitudes) must be corrected to standard conditions before selecting a fan based on standard performance data. Temperature and/or altitude conversion factors are used in making corrections to standard conditions. EXAMPLE: Select a belt driven SQAF fan to deliver 00 at 8" SP at 200 F., and 000 feet altitude. STEP 1. From the table, conversion factor is 1.63. STEP 2. Correct static pressure is: 1.63 x 8" SP = 13.04" SP at standard conditions. STEP 3. Check CPAF catalog for 00 at 13" SP. We select a belt driven SQAF-220, Class III at 24 RPM and 21.9 BHP. STEP 4. Correct the BHP for the lighter air: 21.9 1.63 = 13.3 BHP. A 1 HP motor will suffice at 200 F., and 000' but not at standard conditions. Special motor insulation may be required due to altitude.

DESIGN SPECIFICATIONS Maximum Shaft and Bearing Speeds for Belt Driven Fans Maximum Wheel Speeds & WR 2 (Lb.-Ft. 2 ) for Direct Drive Fans Maximum Shaft and Bearing Speeds HDAF Wheels SQAF Wheels Class II Class IIP Class III Class II Class IIP Class III Fan Size Class IP Class II Class IIP Subject to change without notice. Class III Wheel WR 2 Max. RPM Wheel WR 2 Max. RPM 120 4040 2.9 000 3. 4624 130 30 4.1 4600.0 421 3460.6 4130.2 3890 160 3. 3900.0 360 180 293 280 12.9 38 18.1 36 200 2380 240 3000 1.9 30 2. 34 220 211 2380 2664 2.3 3200 39.2 29 240 1912 21 2409 4. 2900 66. 2680 20 138 1960 2190 81.2 20 89.6 2480 300 168 190 196 11.2 23 169.0 2180 All maximum safe shaft speeds are independent of temperature. Wheel WR 2 Max. RPM Wheel All wheels are steel with a cast iron hub plate. Wheels are not available in aluminum or stainless steel. For steel wheels up to 1 F (80 C). At temperatures above 1 F (80 C), the maximum safe wheel speeds must be reduced by the Maximum RPM Reduction Factors listed on page 6. WR 2 Approximate Shipping Weights Less Motor & Options Fan Arrangement #4 Arrangement #9 Size All Classes Class IP &II Class IIP Class III 120 128 231 130 149 23 162 369 160 190 38 180 280 13 30 200 330 684 220 380 66 4 240 42 806 893 20 620 4 1134 300 30 1239 1418 Subject to change without notice. Construction Gauges Arrangement #4 Arrangement #9 Arrangement #4 & 9 Steel Wheel Fan Size Class Housing Inlet Bell Motor Base Class Housing Inlet Bell Motor Base Bearing Base Shroud Blades Black Plate Reinf. Plate 120 IP 14 IP 14 1/4" 1/4" 12 16 130 IP 14 IP 14 1/4" 1/4" 12 16 IP 14 IP 14 1/4" 1/4" 12 16 160 180 200 IP IIP III 14 14 14 Gauge & 1/4 IP II & IIP II, IIP & III 14 14 14 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 12 12 12 16 16 16 220 III 14 II, IIP & III 14 1/4" 1/4" 12 16 240 III 14 II, IIP & III 14 1/4" 1/4" 11 16 1/4" 20 III 14 II, IIP & III 14 1/4" 1/4" 11 16 1/4" 1/4" 300 III 14 II & IIP 14 1/4" 1/4" III 1/4" 14 1/4" 1/4" 11 16 1/4" 1/4" Max. RPM Wheel WR 2 Max. RPM Wheel WR 2 Max. RPM! DANGER All fans & blowers shown have rotating parts and pinch points. Severe personal injury can result if operated without guards. Stay away from rotating equipment unless it is disconnected from its power source. Read operating instructions.

MODEL WHEEL FAN 1" SP RPM NO. TYPE WIDTH BHP SQAF-120 10 HDAF 1/2 499.1 10 SQAF 1/2 488.16 10 HDAF 3/4 48.22 10 SQAF 3/4 32.24 10 HDAF FULL 99.29 10 SQAF FULL 9.33 8 DIRECT DRIVE RATING TABLES and BHP at Static Pressure Shown Ratings at 0 F.,.0 Density, Sea Level 2" SP BHP 3" SP BHP 4" SP BHP " SP BHP Minimum Motor Frame Size Required 6" SP BHP Symbol indicates minimum motor frame size is required even though the BHP is available in a smaller motor frame size. SEE PAGE 21. 143T Frame Minimum 300 HDAF 1/2 1431 1.11 129 1.1 113 1.1 99 1.1 808 1.14 442.9 300 SQAF 1/2 134 1.18 123 1.24 1122 1.28 9 1.31 802 1.30 86 1.24 300 HDAF 3/4 2146 1.6 1942 1.2 129 1. 1496 1.6 1212 1.1 664 1.46 300 SQAF 3/4 2062 1.6 189 1.8 1683 1.92 1463 1.96 1203 1.9 89 1.8 300 HDAF FULL 2862 2.22 289 2.29 230 2.34 1994 2.34 1616 2.28 88 1.9 300 SQAF FULL 249 2.3 206 2.4 2244 2.6 191 2.61 1604 2.60 112 2.49 SQAF-130 10 HDAF 1/2 42.24 10 SQAF 1/2 16.26 2.24 10 HDAF 3/4 1113.36 10 SQAF 3/4 3.39 416.36 10 HDAF FULL 1484.48 10 SQAF FULL 1431.2.4 300 HDAF 1/2 194 1.9 198 1.84 164 1.88 1484 1.90 1308 1.90 99 1.86 300 SQAF 1/2 181 1.8 119 1.9 180 2.02 1431 2.0 1264 2. 2 2.08 300 HDAF 3/4 2920 2.69 269 2. 246 2.82 2226 2.86 1962 2.8 1649 2.9 300 SQAF 3/4 26 2.80 28 2.92 231 3.03 214 3.11 189 3.14 1608 3.02 300 HDAF FULL 3893 3.9 396 3.69 3290 3.6 2968 3.81 261 3.81 2198 3.2 300 SQAF FULL 301 3.3 343 3.90 3161 4.04 2862 4.14 229 4.19 2144 4.16 SQAF- 10 HDAF 1/2 1203.36 3.3 10 SQAF 1/2 99.39 668.41 10 HDAF 3/4 1804.4 1160.3 10 SQAF 3/4 1649.9 03.61 10 HDAF FULL 240.2 146.0 10 SQAF FULL 2198.9 133.81 300 HDAF 1/2 286 2.48 203 2.62 2 2. 240 2.8 2246 2.96 206 3.02 300 SQAF 1/2 261 2.2 219 2.88 2363 3.02 2198 3.1 2020 3.24 1822 3.30 300 HDAF 3/4 4284 3.3 404 3.93 3832 4.13 3608 4.30 3368 4.44 31 4.3 300 SQAF 3/4 4006 4.08 38 4.32 344 4.3 329 4.2 3030 4.86 233 4.94 300 HDAF FULL 11 4.9 40.24 1.0 48.3 4491.92 4134 6.04 300 SQAF FULL 342.4 03.6 42 6.04 4396 6.29 4040 6.48 3644 6.9 SQAF-160 10 HDAF 1/2 160.6 1292.61 10 SQAF 1/2 143.62 112.6 464.61 10 HDAF 3/4 20.84 1938.91 10 SQAF 3/4 231.93 1691 1.00 696.92 10 HDAF FULL 3340 1.12 284 1.22 10 SQAF FULL 3086 1.24 224 1.34 928 1.22 300 HDAF 1/2 3838 3.96 3666 4.14 303 4.32 3340 4.49 314 4.64 2998 4.6 300 SQAF 1/2 398 4.36 3430 4.6 3261 4.6 3086 4.9 2903.11 206.23 300 HDAF 3/4.9 00 6.22 24 6.48 011 6.4 461 6.96 449.1 300 SQAF 3/4 39 6.3 14 6.8 4891.1 4629.42 434.66 409.8 300 HDAF FULL 66.93 333 8.29 006 8.6 6681 8.98 6348 9.28 996 9.3 300 SQAF FULL 19 8.1 6860 9.13 622 9.3 613 9.90 80.21 412.46 SQAF-180 10 HDAF 1/2 2169.4 18.84 1.88 10 SQAF 1/2 263 1.09 2248 1.1 1908 1.22 1432 1.18 10 HDAF 3/4 324 1. 281 1.26 222 1.32 10 SQAF 3/4 384 1.63 332 1. 2862 1.83 2148 1. 10 HDAF FULL 4339 1.4 33 1.6 3002 1.6 10 SQAF FULL 12 2.1 4496 2.33 3816 2.44 2864 2.36 300 HDAF 1/2 492.18 4633.42 4483.66 4339.89 4196 6.12 402 6.33 300 SQAF 1/2 628 8.19 44 8.3 288 8.2 12 8.68 4968 8.8 4811 9.02 300 HDAF 3/4 189. 6949 8.13 62 8.49 608 8.84 6294 9.1 609 9.49 300 SQAF 3/4 8442 12.28 8182 12.2 932 12. 690 13.03 43 13.28 21 13.2 300 HDAF FULL 98.36 9266.84 896 11.32 8648 11.9 8392 12.23 8 12.6 300 SQAF FULL 1126 16.3 909 16.0 1.03 24 1.3 993 1.1 9623 18.03 SQAF-200 10 HDAF 1/2 2919 1.13 2603 1.28 220 1.3 120 1.3 10 SQAF 1/2 3441 1.69 3094 1.80 241 1.89 233 1.93 10 HDAF 3/4 438 1.0 390 1.91 336 2.06 280 2.02 10 SQAF 3/4 161 2.4 4642 2.0 4112 2.83 30 2.90 10 HDAF FULL 83 2.2 206 2. 401 2. 3440 2.0 10 SQAF FULL 6882 3.38 6189 3.60 483 3.8 463 3.86 300 HDAF 1/2 634 8.13 6166 8.44 998 8.6 83 9.0 680 9.3 23 9.6 300 HDAF 3/4 91 12.19 9249 12.6 899 13.14 86 13.61 819 14.06 828 14.0 300 HDAF FULL 12689 16.2 12332 16.89 1199 1.2 1164 18.14 1139 18. 146 19.33 Performance shown is for installation AMCA type B Free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream.

NOTE 29 1.13 44 1.0 93 2.2 Partial width wheels are available in % increments from 0% widths to 0% widths. This allows for more direct drive ratings than shown in this catalog. Direct drive fans are less expensive to purchase, less maintenance costs and weigh less. Contact your local Cincinnati Fan sales office for more selections. 81 1.1 842 2.02 1.90 114 1.6 112 2. 1263 3.02 832 2.84 12 2.0 162 3.43 1684 4.03 11 3.9 229 3.33 182 3.02 146 2.89 144 1.60 19 3.30 133 3.26 32 3.16 63 3.01 28 4.3 2319 4.34 216 2.40 2396 4.9 200 4.89 148 4.4 980 4.1 304 6.04 3092.8 288 3.20 3194 6.61 263 6.1 2064 6.33 1306 6.02 280 4.8 284 4.88 23 4.81 1898 4.3 2492.31 224.34 1988.32 1686.23 1341. 928 4.90 4208.2 38.32 346.21 284 6.9 338.9 3381 8.01 2982.9 229.8 2012.64 1392.34 611 9.0 169 9. 4620 9.62 396 9.0 4983.63 409.69 396.63 332.46 2682.19 186 9.9 Additional ratings on bottom page 390 6.2 33 6.69 392 6.84 3418 6.96 322.03 3002.03 324 6.91 464 9.1 4496 9.32 433 9.46 4169 9.8 3998 9.68 3816 9. 3622 9.8 3409 9. 88 9.8 630.04 388.26 12.44 4838.4 404.4 4086.3 6981 13.6 644 13.98 602 14.19 624 14.3 996 14.1 2 14.62 434 14.68 113 14.66 811 13.04 06 13.39 184 13.69 6838 13.92 641 14.0 600 14.06 449 13.82 9309 18.3 8992 18.64 860 18.91 8339 19.1 99 19.3 633 19.0 24 19. 6818 19.4 Additional ratings on bottom page 366 9.94 206.21 042.4 482.66 4692.8 401 11.00 4292 11.09 408 11.12 8049 14.92 809 1.31 63 1.6 308 1.99 039 16.2 61 16.49 6438 16.64 608 16.68 32 19.89 412 20.41 084 20.89 944 21.33 938 21.0 9002 21.99 884 22.19 811 22.20 9

DIRECT DRIVE RATING TABLES (Cont d) and BHP at Static Pressure Shown Ratings at 0 F.,.0 Density, Sea Level MODEL WHEEL FAN 1" SP 2" SP 3" SP 4" SP " SP 6" SP RPM NO. TYPE WIDTH BHP BHP BHP BHP BHP BHP SQAF-220 1 HDAF 1/2 2448.64 180.68 1 SQAF 1/2 3139.0 223 1.12 1 HDAF 3/4 362.96 230 1.02 1 SQAF 3/4 408 1.61 384 1.69 1 HDAF FULL 489 1.28 3160 1.36 1 SQAF FULL 62 2.1 04 2.2 10 HDAF 1/2 4226 1.9 3849 2.20 3439 2.38 291 2.46 10 SQAF 1/2 219 3.6 488 3.4 432 3.8 413 3.96 363 3.94 10 HDAF 3/4 6339 2.96 3 3.30 18 3. 43 3.0 10 SQAF 3/4 828.34 32.60 698.81 6202.93 46.91 10 HDAF FULL 842 3.9 698 4.40 688 4. 833 4.93 10 SQAF FULL 43.12 969.4 9064. 820.91 2.88 SQAF-240 1 HDAF 1/2 340 1.00 26 1.13 1 SQAF 1/2 4319 1.1 302 1.82 238 1.4 1 HDAF 3/4 111 1.0 3982 1.69 1 SQAF 3/4 649 2. 3 2.3 4 2.61 1 HDAF FULL 6814 2.00 3 2.26 1 SQAF FULL 8638 3.43 403 3.63 46 3.49 10 HDAF 1/2 31 3.12 31 3.44 4889 3.1 4406 3.91 38 3.99 10 SQAF 1/2 06.2 6690.9 6314 6.18 911 6.34 48 6.43 490 6.40 10 HDAF 3/4 89 4.68 9.16 333.6 6609.8 6.98 10 SQAF 3/4 84 8.8 034 8.9 940 9.2 886 9.0 818 9.64 360 9.60 10 HDAF FULL 11463 6.24 633 6.88 98.42 8812.82 69.9 10 SQAF FULL 14112 11.44 1339 11.93 1262 12.3 11822 12.6 916 12.8 9814 12.80 SQAF-20 10 HDAF 1/2 8884 6.8 842.20 802.62 81 8.00 08 8.30 6484 8.44 10 SQAF 1/2 16 9.32 944 9. 9316.1 883.1 8402.8 88.96 10 HDAF 3/4 13326.1 1269.9 12041 11.42 1132 12.00 62 12.4 926 12.6 10 SQAF 3/4 120 13.98 1461 14.62 1394 1.23 133 1.6 12604 16.18 1182 16.44 10 HDAF FULL 168 13.6 1690 14.39 1604 1.23 1162 16.00 1410 16.60 12969 16.8 10 SQAF FULL 20334 18.63 1948 19.0 18632 20.31 14 21.01 1680 21. 169 21.92 SQAF-300 10 HDAF 1/2 12304 11.3 11816 11.91 1134 12.0 868 13.06 368 13.8 9820 13.99 10 SQAF 1/2 1398 1.1 1316 16.11 13046 16.68 126 1.21 1203 1.68 112 18.06 10 HDAF 3/4 1846 1.03 124 1.8 101 18.4 16302 19.9 11 20.36 1431 20.99 10 SQAF 3/4 20980 23.2 2024 24.16 1969 2.02 1881 2.82 189 26.36 1328 2. 10 HDAF FULL 24608 22.1 23633 23.83 22690 24.99 2136 26.12 203 2.1 19641 2.99 10 SQAF FULL 293 30.02 2032 32.22 26091 33.36 213 34.42 24146 3.36 234 36.13 MODEL WHEEL FAN " SP 8" SP 9" SP " SP 11" SP RPM NO. TYPE WIDTH BHP BHP BHP BHP BHP SQAF-240 10 SQAF 1/2 4112 6.11 10 SQAF 3/4 616 9.1 10 SQAF FULL 8223 12.23 SQAF-20 10 HDAF 1/2 621 8.19 10 SQAF 1/2 288.98 642.4 38 9.91 10 HDAF 3/4 8431 12.29 10 SQAF 3/4 932 16.4 9813 16.11 80 14.8 10 HDAF FULL 11242 16.38 10 SQAF FULL 146 21.96 13084 21.48 69 19.83 SQAF-300 10 HDAF 1/2 9190 14.2 8400 14.22 186 13.4 10 SQAF 1/2 992 18.34 32 18.46 968 18.3 86 1.94 48 16.80 10 HDAF 3/4 138 21.38 1299 21.32 80 20.1 10 SQAF 3/4 1648 2.1 18 2.69 1448 2.6 13164 26.91 11228 2.20 10 HDAF FULL 18381 28.1 1699 28.43 1433 26.89 10 SQAF FULL 21983 36.68 2044 36.93 1931 36. 12 3.88 1490 33.60 Performance shown is for installation AMCA type B Free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. SQAF-180-180 & SQAF-200, Continued from Page 9. MODEL WHEEL FAN 1" SP 16" SP RPM NO. TYPE WIDTH BHP BHP SQAF-180 300 SQAF 1/2 316 9.68 2864 9.46 300 SQAF 3/4 44 14.2 429 14.16 300 SQAF FULL 6329 19.36 29 18.91 SQAF-200 300 HDAF 1/2 38 11.0 3440.80 300 HDAF 3/4 6 16. 160 16.20 300 HDAF FULL 0 22. 6880 21.60 Minimum Motor Frame Size Required Symbols indicate minimum motor frame size is required even though the BHP is available in a smaller motor frame size. SEE PAGE 21. 182T Frame Minimum 213T Frame Minimum

SQAF-120 Size - 13 /16 All wheels are Class IP, SQAF type. SEE PAGE FOR MAX. WHEEL RPM & WR 2 Maximum Fan RPM = 4040 RPM 0 881 89.04 1286.13 18.24 1838.3 208.1 226.6 243.83 2604 1.00 900.06 1414.1 1692.30 1931.44 2143.9 233. 211.93 26 1.11 0 1233 1231. 12.22 18.36 2034.1 223.68 2422.86 294 1.04 24 1.24 1200 1409 1406.14 1698.28 1936.44 2148.60 2340.8 218.9 2684 1.1 2840 1.3 130 18 182.21 1848.36 200.3 2269.1 242.90 2623 1. 282 1.31 2934 1.3 0 161 18.28 2002.4 22.63 2398.83 21 1.03 234 1.2 2888 1.4 3034 1.0 160 193 1934.38 2160.6 23.6 232.9 269 1.18 283 1.41 3001 1.6 3141 1.89 1800 2113 29.49 2320.69 203.90 261 1.12 2829 1.36 29 1.60 3119 1.8 32 2. 190 2290 228.62 2482.84 26 1.0 281 1.30 296 1. 3 1.80 3243 2.06 334 2.33 20 2466 2461. 264 1.01 28 1.2 2962 1.0 3 1.6 3241 2.03 332 2.31 3498 2.9 220 2642 263.9 28 1.20 2966 1.46 3111 1.3 3249 2.00 339 2.28 30 2. 3626 2.8 2400 2818 2813 1.1 29 1.42 312 1.0 3264 1.98 339 2.2 321 2.6 3642 2.8 39 3.18 20 2994 2988 1.39 3144 1.6 328 1.96 3418 2.26 344 2.6 366 2.8 382 3.19 389 3.1 200 310 3164 1.64 3312 1.9 344 2.2 3 2.6 3696 2.88 3812 3.21 392 3.4 4034 3.88 280 3346 3340 1.93 3480 2.2 36 2. 333 2.90 3849 3.24 3962 3.8 3000 322 316 2.26 360 2.9 34 2.93 3892 3.2 400 3.62 3 3699 3692 2.61 3820 2.96 3939 3.32 3300 38 386 3.00 3990 3.3 Minimum motor frame size is 6 regardless of BHP. 0 881 261 1.18 2909 1.3 300 1. 3184 1.8 3313 1.99 3436 2.21 3 2.44 360 2.6 900 2830 1.30 296 1.0 3114 1.1 324 1.93 334 2.1 3496 2.38 3614 2.62 328 2.86 0 1233 290 1.44 3049 1.6 318 1.8 3316 2. 3441 2.33 362 2. 368 2.82 391 3.0 1200 1409 2988 1.9 3128 1.81 3262 2.04 3390 2.28 314 2.2 3633 2.8 348 3.03 389 3.30 130 18 30 1.6 3214 1.99 334 2.23 341 2.48 392 2.4 3 3.00 3823 3.2 3933 3.4 0 161 313 1.94 330 2.19 343 2.44 38 2.0 36 2.9 392 3.24 3903 3.2 4011 3.81 160 193 326 2.14 3406 2.40 330 2.6 360 2.94 36 3.22 389 3.0 3989 3.80 1800 2113 338 2.3 3 2.64 3631 2.92 349 3.20 3862 3.49 392 3.9 190 2290 3499 2.61 3621 2.90 338 3.19 382 3.48 3963 3.9 20 2466 3619 2.88 33 3.18 381 3.48 3961 3.9 220 2642 343 3.18 38 3.49 3968 3.80 2400 2818 382 3.0 3982 3.82 20 2994 4004 3.8 200 310 Maximum motor frame size is 213T. 0 881 382 2.91 3890 3.16 399 3.41 900 3838 3.11 3946 3.3 0 1233 3901 3.33 400 3.60 1200 1409 3968 3. Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances in the airstream. Check direct drive tables on pages 8 and 9. Arrangement 4 would be more compact, less expensive and require less maintenance. 11

SQAF-130 Size - 1 /16 All wheels are Class IP, SQAF type. SEE PAGE FOR MAX. WHEEL RPM & WR 2 Maximum Fan RPM = 30 RPM 900 86 9.04 116.1 1441.29 160.4 181.62 201.80 221 1.00 2368 1.21 10 60 92.08 1296.21 148.36 164.3 196.2 2130.92 2290 1.13 2440 1.3 1300 122 1148.13 1436.28 166.4 1869.64 202.84 2219 1.06 234 1.28 220 1.2 0 144 132.19 183.3 19.6 198.6 218.98 2318 1.21 246 1.46 2608 1.1 100 163 1.28 136.48 1932.69 29.91 223 1.1 242 1.39 268 1.6 204 1.92 1900 1830 168.39 1892.61 20.84 2241 1.08 239 1.33 240 1.60 268 1.88 2808 2.16 20 2023 18.3 202. 2223 1.02 239 1.28 22 1. 2663 1.83 294 2.13 2919 2.43 2300 221 2031.0 2214.96 234 1.22 222 1.1 2660 1.80 291 2. 291 2.41 303 2.3 200 2408 2208.90 238 1.18 229 1.4 2669 1. 2800 2.08 292 2.40 304 2.3 3160 3.06 200 2601 238 1.13 244 1.43 2686 1.4 2819 2.06 2944 2.39 3063 2.3 318 3.08 3289 3.43 2900 293 261 1.40 2 1.2 2846 2.0 292 2.39 3091 2.4 320 3. 331 3.4 3422 3.84 30 2986 238 1.1 288 2.0 300 2.41 312 2. 3241 3.14 331 3.1 346 3.90 39 4.29 3300 319 291 2.06 304 2.43 310 2.80 3284 3.18 3394 3. 3499 3.9 3601 4.3 3699 4.9 300 331 3091 2.46 321 2.8 3334 3.24 3444 3.64 349 4.0 360 4.4 34 4.90 300 364 3268 2.90 338 3.31 3499 3.3 3604 4.1 30 4.8 3900 3 344 3.40 38 3.83 366 4.2 40 3949 3621 3.9 330 4.40 Minimum motor frame size is 6 regardless of BHP. 900 86 211 1.42 2646 1.6 24 1.89 2896 2.14 3013 2.40 312 2.66 3234 2.94 3338 3.22 10 60 280 1.9 213 1.83 2839 2.08 299 2.34 30 2.61 3186 2.89 3293 3.18 339 3.4 1300 122 26 1. 28 2.03 29 2.29 3029 2. 3143 2.8 322 3.1 338 3.4 3461 3. 0 144 241 1.9 2868 2.2 2989 2.3 3 2.82 321 3.12 332 3.42 3429 3.4 331 4.06 100 163 2833 2.20 29 2.49 30 2.9 3189 3. 3298 3.41 3404 3.3 30 4.06 3606 4.40 1900 1830 2933 2.46 302 2.6 316 3.08 328 3.40 338 3.3 3489 4.0 390 4.41 368 4.6 20 2023 3040 2.4 31 3.0 326 3.40 334 3.3 349 4.08 380 4.43 368 4.9 2300 221 313 3.06 3264 3.40 332 3. 34 4. 38 4.46 36 4.83 200 2408 322 3.41 339 3. 3484 4.13 38 4.0 3683 4.88 200 2601 3396 3.80 300 4.1 3600 4. 3699 4.94 2900 293 32 4.23 362 4.62 322.02 Maximum motor frame size is 21T. 30 2986 368 4.69 900 86 3440 3.1 338 3.81 3634 4.11 10 60 349 3.8 39 4.09 3689 4.40 1300 122 360 4.0 36 4.39 0 144 3629 4.39 324 4.3 100 163 303 4.4 Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances in the airstream. Check direct drive tables on pages 8 and 9. Arrangement 4 would be more compact, less expensive and require less maintenance. 12

SQAF- 16.19 16 9 /16 SEE PAGE FOR MAX. WHEEL RPM & WR 2 All wheels are Class IP, SQAF type. Maximum Fan RPM = 3460 RPM 00 82 619.03 990.1 124.30 140.48 16.6 1823.89 19 1.12 2116 1.36 120 9 4.06 94.20 1338.3 144.6 12. 188 1.00 2036 1.2 213 1.1 0 113 929. 1211.26 1434.4 1628.66 1801.89 198 1.14 23 1.40 2238 1.68 10 1368 84.1 1336.34 140. 121.9 1886 1.03 203 1.30 218 1.8 23 1.8 2000 164 1239.23 1466.44 164.68 1824.93 1980 1.20 2124 1.48 2260 1.8 238 2.09 220 19 1394.32 1601.6 16.82 1934 1.09 2081 1.38 2219 1.68 2349 2.00 242 2.33 200 19 148.44 140.1 1902.99 200 1.28 2189 1.9 2320 1.91 2444 2.2 263 2.60 20 2 103.9 1880.88 2032 1.18 212 1.0 2303 1.83 242 2.1 246 2.3 2660 2.90 3000 2346 188. 2023 1.08 2166 1.41 2298 1. 2422 2. 240 2.46 264 2.84 263 3.23 320 241 2013.98 216 1.32 2302 1.66 242 2.03 24 2.40 268 2.9 266 3.18 280 3.9 300 236 2168 1.22 2312 1.8 2440 1.96 29 2.34 262 2.4 29 3.1 2883 3. 2983 3.99 30 2932 2323 1.0 249 1.89 281 2.29 2694 2.0 2801 3.12 2904 3. 3003 3.99 3099 4.44 4000 312 24 1.82 2606 2.24 222 2.66 2830 3.09 2933 3.3 3032 3.98 312 4.4 3219 4.92 420 3323 2632 2.19 24 2.62 286 3.0 2969 3.3 306 3.99 3162 4.4 323 4.9 3342.4 400 318 28 2.9 2903 3.06 3009 3.3 38 4.01 3203 4.0 3294.00 3382.1 40 314 2942 3.0 302 3.4 314 4.04 3249 4.4 3340.0 3428.8 000 3909 309 3.6 3202 4.0 3300 4.60 3391.12 20 4 322 4.12 332 4.66 3446.21 00 4300 3406 4.4 Minimum motor frame size is 6 regardless of BHP. 00 82 224 1.62 231 1.90 2489 2.18 2601 2.48 209 2.9 2812 3.11 2912 3.44 3009 3.8 120 9 2303 1.8 242 2.0 241 2.3 261 2.68 2 3.01 2860 3.34 298 3.68 303 4.03 0 113 236 1.9 248 2.2 299 2.8 208 2.91 2813 3.2 2914 3.9 3011 3.9 3 4.32 10 1368 2434 2.18 21 2.49 2664 2.82 21 3.16 284 3.2 293 3.88 3069 4.2 3162 4.63 2000 164 208 2.41 2624 2.4 234 3.09 2839 3.4 2940 3.81 3038 4.19 3133 4.8 322 4.98 220 19 289 2.6 201 3.02 2809 3.38 2912 3.6 3012 4.14 38 4.3 3201 4.94 3291.3 200 19 266 2.96 28 3.33 2890 3.1 2991 4. 3088 4.0 3182 4.91 324.33 3363.6 20 2 269 3.2 284 3.66 296 4.06 304 4.4 3169 4.89 3261.32 331.6 3438 6.20 3000 2346 2868 3.62 2969 4.03 3068 4.4 3163 4.88 326.32 3346. 3433 6.22 320 241 291 4.01 3069 4.44 3164 4.88 32.33 334.8 3434 6.2 300 236 3080 4.43 314 4.88 3266.34 33.81 3443 6.28 30 2932 3193 4.90 3283.3 332.84 349 6.33 4000 312 3309.40 339.89 420 3323 3429.9 Maximum motor frame size is 21T. 00 82 32 4.12 3281 4.8 341.61 120 9 314 4.40 3322.1 0 113 3196 4.0 331.48 10 1368 322.02 342.83 2000 164 3313.38 220 19 339. 200 19 3449 6.20 Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances in the airstream. Check direct drive tables on pages 8 and 9. Arrangement 4 would be more compact, less expensive and require less maintenance. 13

SQAF-160 All wheels are Class IP, SQAF type. SEE PAGE FOR MAX. WHEEL RPM & WR 2 Maximum Fan RPM = 3RPM 0 91 69.0 989.24 1212.44 1399.68 164.93 111 1.21 1846 1.1 192 1.82 1800 116 836.11 94.31 129.4 144.80 1632 1.08 1 1.3 190 1.69 2030 2.02 20 139 9.18 1206.41 1392.66 18.94 108 1.24 1846 1.6 194 1.90 2094 2.2 2400 13 111.2 1323.2 149.81 1649 1.11 192 1.43 1923 1. 204 2.13 2163 2.1 200 148 124.38 1444.6 1603.98 148 1.30 1882 1.6 2008 2.02 2126 2.40 2239 2.9 3000 1942 1393.2 168.84 11 1.1 182 1.3 199 1.90 2098 2.29 2212 2.69 2320 3.11 3300 2136 132.0 169 1.04 1834 1.40 1961 1.9 2081 2.18 219 2.60 2303 3.02 240 3.4 3600 2330 162.90 1823 1.28 194 1.6 204 2.08 2188 2.0 2296 2.94 2399 3.39 2499 3.86 3900 224 1811 1.1 192 1.6 206 1.98 2190 2.41 2298 2.86 2401 3.32 200 3.80 29 4.29 4200 219 190 1.44 2083 1.8 2200 2.32 2309 2.8 2411 3.26 2 3. 2604 4.2 2696 4. 400 2913 2090 1. 221 2.23 2326 2.1 2429 3.20 228 3.1 2622 4.22 212 4. 2800.29 4800 3 2229 2.14 234 2.64 243 3.1 22 3.6 2646 4.20 236 4.4 2823.30 2908.8 0 3301 2368 2. 2480 3. 282 3.64 266 4.18 266 4.4 283.31 293.90 3018 6.49 400 349 208 3.0 2614 3.61 211 4.18 2802 4. 2888.34 292.94 00 3690 264 3.9 248 4.18 2841 4.8 2929.38 3012 6.00 6000 3884 286 4.19 2883 4.81 292.43 6300 408 2926 4.8 3018.0 Minimum motor frame size is 6 regardless of BHP. 0 91 2089 2.1 2200 2.0 2306 2.86 2406 3.24 203 3.63 296 4.03 268 4.4 22 4.8 1800 116 214 2.3 224 2.4 238 3.12 24 3.1 22 3.92 2644 4.34 232 4. 2818.21 20 139 220 2.62 2314 3.00 2416 3.40 213 3.81 260 4.24 2698 4.6 28.12 2869.9 2400 13 223 2.90 238 3.30 248 3.2 24 4.1 266 4.9 26.0 2842.2 292 6.00 200 148 2346 3.20 2448 3.63 246 4.0 2640 4.2 230 4.98 2818.46 2903.94 298 6.44 3000 1942 2423 3. 223 3.99 2618 4.4 2 4.92 298.41 2884.90 2968 6.41 3300 2136 206 3.92 2602 4.39 269 4.8 284.3 281.8 29 6.39 303 6.92 3600 2330 29 4.34 268 4.83 2.34 2864.8 2948 6.38 3030 6.92 3900 224 268 4.80 2.31 2864.84 2948 6.38 3030 6.93 4200 219 284.30 281.84 294 6.39 3036 6.96 400 2913 288.8 2968 6.41 4800 3 2990 6.4 Maximum motor frame size is 21T. 0 91 286.31 293.6 3016 6.22 1800 116 2901.6 2981 6.14 20 139 291 6.06 3031 6.4 2400 13 3006 6.49 Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances in the airstream. Check direct drive tables on pages 8 and 9. Arrangement 4 would be more compact, less expensive and require less maintenance. 14

WHEEL Dia. - 19.68" SQAF-180 OUTLET I.D. Size - 1 " x 1 13 /16" Area - 1.96 Sq. Ft. I.D. SEE PAGE FOR MAX. WHEEL RPM & WR 2. 0 6 1800 918 20 1 2400 1224 200 13 3000 130 3300 1683 3600 1836 3900 1989 4200 2142 400 229 4800 2448 0 2602 400 2 00 2908 6000 3061 6300 3214 6600 336 6900 320 200 363 00 3826 800 399 80 4132 8400 428 800 4438 9000 491 9300 444 9600 489 43.03 44.06 634. 2.14 81.20 906.28 99.3 8.48 118.61 1268.6 139.94 140 1.14 140 1.36 1631 1.62 121 1.90 1812 2.22 1903 2. 1993 2.96 2084 3.38 214 3.84 226 4.34 23 4.88 2446.46 23 6.09 262 6. 218.0 2808 8.2 2899 9. 0.16 2.20 843.26 916.33 991.41 6.1 114.62 1224. 130.90 138 1.0 141 1.2 16 1.49 1641 1.4 126 2.02 1812 2.32 1899 2.66 1986 3.03 203 3.44 2160 3.88 2248 4.3 2336 4.89 2424.4 212 6.06 2600 6.1 2689.41 2 8.1 2866 8.9 29 9.9 INLET O.D.* Size - 20 9 /16" Area - 2.31 Sq.Ft. O.D. 8.30 931.3 993.44 9.3 1128.63 1199. 122.88 1346 1.03 1422 1.21 1498 1.40 16 1.62 164 1.86 134 2.13 1814 2.43 189 2. 199 3.11 2063 3.1 214 3.93 2232 4.40 231 4.90 2402.44 2488 6.03 24 6.66 2661.33 24 8.0 2834 8.82 2921 9.64 3009.0 48.48 64. 1120.64 119. 1244.8 1311 1.00 1380 1.16 141 1.33 123 1.2 19 1.4 162 1.9 14 2.24 1823 2.3 1901 2.84 199 3.19 208 3. 2138 3.99 2218 4.44 2299 4.92 2382.4 2466 6.01 20 6.62 2634.2 219.96 2804 8.0 2889 9.49 29.33 3061 11.22 BELT DRIVE RATING TABLES Ratings at 0 F.,.0 Density, Sea Level All wheels are SQAF type. Class II = light face above Class IIP Class IIP = bold face 1213.6 1233.8 1289.98 1346 1.11 1411 1.2 14 1.44 144 1.64 1614 1.8 1686 2.08 18 2.34 1832 2.62 1906 2.93 1981 3.2 20 3.64 2134 4.04 2212 4.48 2290 4.9 2369.4 2448 6.00 229 6.8 2609.21 2691.88 2 8.60 288 9.36 2942.1 302 11.03 3111 11.94 1481 1.3 1493 1.48 134 1.64 190 1.83 1648 2.04 112 2.2 1 2.2 1844 2.80 1912 3. 1982 3.42 204 3. 2126 4.1 2199 4.6 224.00 2348.48 2423.99 2499 6.3 26.12 263. 231 8.42 2809 9.13 2888 9.88 296.69 304 11.4 3128 12.44 3208 13.40 109 2.0 121 2.24 149 2.44 180 2.68 1862 2.94 1921 3.23 1986 3.4 201 3.88 2118 4.2 2186 4.64 226.06 2326.1 2398.99 241 6.0 244.0 2618.64 2693 8.2 268 8.94 2843 9.6 2919.40 2996 11.20 303 12.04 311 12.94 3230 13.88 3308 14.88 200 13 3000 130 3300 1683 3600 1836 3900 1989 4200 2142 400 229 4800 2448 0 2602 400 2 00 2908 6000 3061 6300 3214 6600 336 6900 320 200 363 00 3826 800 399 80 4132 8400 428 800 4438 9000 491 9300 444 9600 489 4200 2142 400 229 4800 2448 0 2602 400 2 00 2908 6000 3061 6300 3214 6600 336 6900 320 200 363 00 3826 800 399 1912 2.90 1923 3.12 1946 3.3 2001 3.6 208 3.9 211 4.32 218 4.69 2243. 2309.3 236.99 2443 6.49 213.01 284.6 26 8.1 228 8. 2801 9.44 284.1 2949.90 3023 11.69 3098 12.3 314 13.42 320 14.3 3326 1.34 3403 16.3 2096 3.8 2 4.11 2129 4.39 2184 4. 2241.13 2298.4 238.9 2423 6.44 2488 6.94 24.4 2621 8.04 2689 8.64 29 9.2 2830 9.93 2902.64 294 11.38 304 12.1 3120 13.01 3194 13.89 3269 14.82 3343 1.9 3418 16.82 3494 1.89 2266 4.91 22.21 2302. 23.96 2413 6.41 240 6.88 229.38 293.91 268 8.48 224 9.08 291 9.3 288.41 292 11.12 299 11.86 3068 12.64 3140 13.4 3212 14.34 328 1.26 338 16.23 3432 1.2 30 18.31 381 19.43 Minimum motor frame size is 6 regardless of BHP. 2414. 242 6.09 264 6.98 269.90 243 6.43 2466 6.82 222.30 28.81 263 8.34 2693 8.91 2 9.2 2822.1 288.83 293 11. 3020 12.30 3088 13. 318 13.92 3228 14.9 3299 1.0 331 16.66 3443 1.66 316 18.2 390 19.83 2.3 28.6 2624 8.22 2680 8.6 236 9.33 293 9.94 281. 2914 11.2 299 11.96 3044 12.1 31 13.0 31 14.34 324 1.22 3313 16.13 3383 1.08 344 18.0 32 19.12 39 20.21 12" SP 13" SP 14" SP 1" SP 16" SP 1" SP 2962.82 294 11.33 298 11.8 3012 12.44 3068 13.14 3124 13.88 3180 14.66 323 1.48 329 16.33 339 1.23 3424 18.1 3489 19.16 34 20.19 30 11.89 3088 12.44 30 13.00 3111 13.6 312 14.2 3208 1.03 3264 1.84 3320 16.69 338 1.8 3436 18.1 300 19.49 36 20.1 3198 13. 32 14.16 3221 14. 3234 1.38 3289 16.19 3344 1.04 3401 1.92 348 18.8 31 19.81 34 20.82 3304 14.1 3316 1.3 332 1.99 3339 16.64 336 1.38 3423 18.26 349 19.1 33 20.13 392 21.13 3419 16. 3430 1.23 3441 1.92 343 18.62 3499 19.49 34 20.44 20 8.33 218 8.6 230 9.19 26 9.4 2832.3 2888.98 2946 11.66 3003 12.36 306 13.11 3131 13.90 3196 14.3 3262 1.60 3329 16.1 3396 1.4 3464 18.48 334 19.1 360 20.9 318 1. 330 18.49 341 19.22 32 19.96 32 20.4 Maximum Motor Frame Size = 24T (Class II) Maximum Motor Frame Size = 26T (Class IIP) 2832 9.31 2843 9.8 284.2 2869.4 2924 11.38 2980 12.0 3036 12.6 3093 13.0 311 14.28 321 1. 329 1.9 3344 16.8 34 1.83 34 18.82 344 19.8 Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. *Inlet O.D. if optional inlet collar is ordered. Check direct drive tables on pages 8, 9 and. Arrangement 4 would be more compact, less expensive and require less maintenance. 1

WHEEL Dia. - 21.6" SQAF-200 SEE PAGE FOR MAX. WHEEL RPM & WR 2. 0 638 1900 808 2300 98 200 1148 30 1319 300 1489 3900 169 4300 1829 400 2000 0 210 00 2340 900 2 6300 2680 600 281 0 3021 00 3191 900 3361 8300 331 800 302 90 382 900 4042 9900 4212 300 4382 00 43 110 423 10 4893 30 1319 300 1489 3900 169 4300 1829 400 2000 0 210 00 2340 900 2 6300 2680 600 281 0 3021 00 3191 900 3361 8300 331 800 302 90 382 900 4042 9900 4212 300 4382 00 43 110 423 10 4893 OUTLET I.D. Size - 1 3 " x 19 /16" Area - 2.3 Sq. Ft. I.D. 34.02 436.0 28.09 620.14 12.21 804.31 896.42 988. 9.4 111.9 1263 1.19 13 1.4 144 1.9 139 2.1 1631 2.6 123 3.01 1814 3.2 1906 4.08 1998 4.0 2090.38 2182 6.12 224 6.93 2366.80 248 8. 249 9.6 2641.86 141 3.39 12 3.6 168 3.9 1824 4.36 1881 4.9 1940.26 2004.6 200 6.31 2138 6.91 2206. 226 8.23 234 8.9 2420 9.3 2493. 26 11.4 2642 12.42 218 13.44 293 14.3 280 1.68 294 16.90 3024 18.20 32 19. 9.1 660.20 29.2 802.3 88.4 94. 33.2 1113.89 119 1.09 129 1.33 1364 1.60 140 1.90 136 2.2 1624 2.64 111 3.08 199 3.6 188 4. 196 4.69 206.34 214 6.04 2243 6.81 2333.6 2422 8. 212 9.3 2602. 2692 11.0 19 4.4 1922 4.88 1940.24 199.2 204 6.23 2112 6.8 21.38 2241 8.02 2308 8.1 23 9.4 2444.2 21 11.08 28 11.96 269 12.91 233 13.92 280 14.99 2882 16.13 29 1.34 3033 18.61 39 19.9 318 21.39 INLET O.D.* Size - 22 9 /16" Area - 2.8 Sq.Ft. O.D. 82.32 812.39 80.4 936.8 0.1 6.86 1 1.03 122 1.23 1301 1.46 139 1.2 148 2.02 138 2.3 1619 2.3 101 3.1 18 3.61 180 4.13 19 4.69 2041.31 212.99 2214 6.2 2301.2 2389 8.38 24 9.32 26.32 263 11.39 242 12.4 206.84 208 6.24 23 6.68 2160.24 221.84 22 8.48 2338 9.1 2403 9.91 240.0 23 11.4 260 12.44 26 13.38 246 14.38 2818 1.44 2891 16.6 296 1. 3039 19.01 3114 20.3 3189 21.6 326 23.24 99.60 991.0 49.83 1112.98 119 1.16 1249 1.36 1320 1.8 1394 1.84 1469 2.13 14 2.4 1622 2.81 1699 3.22 18 3.66 188 4.16 1939 4.0 2020.29 23.94 218 6.64 222.41 23 8.23 2443 9.13 229.08 261 11.12 202 12.22 289 13.40 BELT DRIVE RATING TABLES Ratings at 0 F.,.0 Density, Sea Level All wheels are SQAF type Class II = light face above Class IIP Class IIP = bold face below Class II Class III = italic face below Class IIP 1111.9 111 1. 1208 1.2 121 1.4 1338 1.0 1406 1.9 14 2.23 149 2. 1623 2.90 1698 3.29 14 3.2 181 4.19 1928 4.1 200.28 2086.90 2166 6.8 224.31 2328 8. 24 8.96 2494 9.88 29.86 2664 11.92 249 13.0 283 14.26 13 1.0 1380 1.89 143 2.13 149 2.41 19 2.1 162 3.0 1693 3.42 163 3.82 183 4.26 190 4. 1981.2 206.8 2132 6.4 2208.1 228.88 2362 8.66 2441 9.1 220.42 2600 11.40 2680 12.44 261 13.6 2842 14.4 2924 16.01 16 2.61 183 2.8 1639 3.16 169 3.1 1 3.90 1822 4.32 1889 4.8 19.28 202.82 2098 6.39 211.02 2244.0 2318 8.43 2394 9.21 2469.0 24-9 2622 11.92 200 12.9 28 14.0 286 1.22 2936 16.46 3016 1.8 Minimum motor frame size is 6 regardless of BHP. 2202 6.83 2213.28 222.4 229 8.28 2316 8.93 233 9.61 2431.3 2494 11.13 29 11.9 262 12.86 2692 13.81 260 14.81 2829 1.88 2900 16.99 292 18.16 3044 19.40 311 20.1 3191 22. 326 23.6 3340 2. 2340 8.3 231 8.86 2363 9.39 2409.04 2466.8 223 11.6 282 12.39 2644 13.2 209 14.21 2 1.20 2842 16.26 29 1.38 299 18.6 3049 19.9 3120 21.08 3192 22.44 326 23.88 3338 2.39 241.02 2483.9 2498 11.19 24 11.9 2611 12.9 2668 13.6 22 14.60 289 1.8 28 16.62 2921 1.3 2988 18.89 30 20.13 3124 21.43 3194 22.8 326 24.20 333 2.68 28 11.20 29 11.83 2608 12.46 2638 13.18 2694 14.0 21 14.98 2809 1.9 2868 16.98 2931 18.0 2996 19.22 3062 20.43 3129 21.2 319 23.0 326 24.49 333 2.9 0 210 00 2340 900 2 6300 2680 600 281 0 3021 00 3191 900 3361 8300 331 800 302 90 382 900 4042 9900 4212 300 4382 12" SP 13" SP 14" SP 1" SP 16" SP 1" SP 206 13.09 21 13. 229 14.4 2 1.34 2831 16.31 2888 1.33 2946 18.41 300 19.4 3069 20.4 313 22.00 3201 23.33 3268 24.3 333 26.20 3404 2.4 28 14.38 2822 1.11 2833 1.86 282 16.6 2908 1.6 296 18.3 3022 19.86 3080 21.04 3140 22.28 3204 23.9 320 24.96 3336 26.41 3403 2.93 2922 16.48 2934 1.2 294 18.08 2982 19.0 3039 20.16 309 21.33 313 22. 3211 23.84 322 2.20 333 26.62 3403 28.11 Check direct drive tables on pages 8, 9 and. Arrangement 4 would be more compact, less expensive and require less maintenance. 3019 1.86 3031 18.1 3042 19. 304 20.4 31 21.61 316 22.82 3224 24.09 3282 2.43 3340 26.83 3402 28.30 3113 19.28 312 20.18 3136 21.09 3148 22.01 319 23.08 3236 24.34 3292 2.66 330 2.04 321 21.66 322 22.62 3239 23.60 320 24.9 3303 2.8 339 2.24 Maximum Motor Frame Size = 26T (Class II) Maximum Motor Frame Size = 286T (Class IIP) Maximum Motor Frame Size = 324T (Class III) Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. *Inlet O.D. if optional inlet collar is ordered. 16

WHEEL Dia. - 24" SQAF-220 SEE PAGE FOR MAX. WHEEL RPM & WR 2. 200 89 3000 30 300 1202 4000 134 OUTLET I.D. Size - 19 3 " x 21 " Area - 2.91 Sq. Ft. I.D. 394.08 43.13 2.21 631.31.28 632.36 691.48.61 INLET O.D.* Size - 24 9 /16" Area - 3.29 Sq.Ft. O.D. 26.4.64 8. 86.94 866.84 88.9 911 1.11 961 1.30 BELT DRIVE RATING TABLES Ratings at 0 F.,.0 Density, Sea Level All wheels are SQAF type Class II = light face above Class IIP Class IIP = bold face below Class II Class III = italic face below Class IIP 03 1.34 24 1.1 0 1.69 1224 2.36 1240 2.63 1412 3.60 400 146 000 118 00 1890 6000 2061 09.44 88.61 86.81 946 1.0 822.8 890.99 99 1.23 31 1.0 923 1.14 983 1.3 4 1.64 1113 1.96 1 1.2 1 1.8 1130 2.08 1189 2.43 9 1.93 1 2.22 1206 2. 1263 2.92 126 2.89 1291 3.16 1343 3.4 1396 3.9 1426 3.98 141 4.31 146 4.66 114.08 600 2233 000 240 00 2 8000 249 2 1.34 13 1.6 1182 2.06 1261 2.0 1 1.82 118 2.19 123 2.61 1328 3.09 1180 2.32 1248 2.3 131 3.19 1388 3.0 122 2.81 131 3.26 1384 3. 141 4.30 1322 3.34 1382 3.80 144 4.33 1 4.91 140 4.43 4.96 16. 1624 6.18 166.61 1619 6.19 164 6.82 130.2 800 2920 9000 3092 900 3264 000 3436 1340 2.99 1419 3. 149 4.18 16 4.8 1403 3.62 148 4.22 14 4.88 1630.61 1461 4.2 134 4.90 160.60 1681 6.36 119 4.91 188.9 16 6.33 129.13 16. 1643 6.26 111.04 19.88 1683 6.88 14.64 18 8.48 186 9.40 188 8.28 184 9.11 1906.00 1966.96 00 3608 100 380 10 391 12000 4123 16.64 134 6.49 1813.41 1892 8.42 10 6.42 183.30 1860 8.26 193 9.30 16.20 1830 8.12 190 9.12 1981.20 1802 8.00 18 8.96 1949 9.99 2023 11.11 1848 8.81 1918 9.81 1990.8 2063 12.02 1942.39 2009 11.4 20 12.60 214 13.84 2029 12.00 2094 13.13 2160 14.3 2226 1.6 1200 429 13000 446 1300 4639 14000 48 190 9.2 2049.1 2128 11.99 220 13.3 2014.43 2091 11.66 2169 12.98 2246 14.40 206 11.3 2132 12.63 2208 13.98 2284 1.44 209 12.31 211 13.61 2246 1.00 2321 16.49 2136 13.26 2209 14.9 2283 16.02 23 1. 2214 1.1 2283 16.9 233 18. 242 19.69 2293 1.0 2361 18.3 2428 20.12 249 21.80 400 146 000 118 00 1890 6000 2061 19.06 194.3 1618.9 1643 6.38 118 6.1 132 6.2 146.29 11.9 189.96 184 8.60 1889 9.26 Minimum motor frame size is 143T regardless of BHP. 1992 9.9 2006.69 24 11.32 2118 12.1 2223 13.63 2323 1.14 600 2233 000 240 00 2 8000 249 161 6.84 123.48 16 8.1 1829 8.92 196 8.31 1822 8.8 180 9. 1922.38 1914 9.84 1939.44 196 11.0 2009 11.88 2024 11.43 2049 12.09 204 12.8 2099 13.0 2132 12.99 212 13.9 21 14.4 2202 1.32 223 14. 222 1.0 224 16.3 2299 1.19 2338 16.14 232 1.1 236 18.20 2392 19.11 800 2920 9000 3092 900 3264 000 3436 1884 9.2 1941.61 1999 11. 20 12.9 19 11.24 2030 12.1 208 13.1 2143 14.26 2061 12.81 2114 13.9 2168 14.8 2223 1.9 2142 14.41 2194 1.46 224 16. 2301 1. 222 16.13 220 1.16 2323 18.33 236 19.8 2324 18.06 230 18.9 239 20.13 244 21.43 241 20.04 2442 21.01 2468 22.01 21 23.32 00 3608 100 380 10 391 12000 4123 211 13.69 21 14.8 2238 16.13 2302 1.0 2201 1.43 229 16.6 2318 1.99 238 19.40 2280 1.20 233 18.1 239 19.89 244 21.3 23 19.01 2411 20.3 2469 21.82 226 23.36 2429 20.90 2483 22.29 239 23.8 296 2.38 200 22.81 23 24.2 260 2.80 2662 2.43 268 24.6 2620 26.28 264 2.88 228 29.6 1200 429 13000 446 1300 4639 14000 48 2368 18.9 2434 20.1 200 22.16 26 23.91 2439 20.90 203 22.1 268 24.23 2634 26.04 214 22.93 23 24.8 2634 26.33 2698 28.21 28 24.99 2644 26.0 203 28.2 264 30.43 263 2.0 211 28.86 20 30.4 2829 32.1 219 29.18 26 31.03 2834 32.98 282 31.32 2839 33.24 600 2233 000 240 00 2 8000 249 800 2920 9000 3092 900 3264 000 3436 00 3608 100 380 10 391 12000 4123 1200 429 12" SP 13" SP 14" SP 1" SP 16" SP 2433 1. 244 18.86 2462 19.99 2480 21.0 20 22.06 230 23.09 26 24.1 281 2.2 2633 26.4 268 28.32 238 29.98 291 31.2 2846 33. 22 19.39 239 20.8 24 21.9 268 23.02 290 24.12 261 2.21 2640 26.34 2666 2.0 2696 28. 248 30.39 2800 32.11 283 33.92 2628 22.32 2642 23.61 266 24.92 262 26.23 269 2.38 222 28.6 24 29.8 23 31.04 2808 32.49 213 24.09 22 2.4 241 26.84 26 28.26 26 29.8 2801 30.82 2826 32.11 281 33.43 2809 2.32 2824 28.9 2838 30.29 282 31.81 Maximum Motor Frame Size = 26T (Class II) Maximum Motor Frame Size = 286T (Class IIP) Maximum Motor Frame Size = 324T (Class III) Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. *Inlet O.D. if optional inlet collar is ordered. Check direct drive tables on page. Arrangement 4 would be more compact, less expensive and require less maintenance. 1

WHEEL Dia. - 26.44" SQAF-240 SEE PAGE FOR MAX. WHEEL RPM & WR 2. 3000 82 3600 22 4200 1193 4800 1363 OUTLET I.D. Size - 21 /16" x 23 13 /16" Area - 3.2 Sq. Ft. I.D. 34.09 424.1 49.2 66.3 19.33 0.43 623. 680.3 INLET O.D.* Size - 2 9 /16" Area - 4.14 Sq.Ft. O.D. 6.6 684.6 31.92 81 1.12 8 1.01 802 1.1 82 1.33 868 1. BELT DRIVE RATING TABLES Ratings at 0 F.,.0 Density, Sea Level All wheels are Type SQAF type Class II = light face above Class IIP Class IIP = bold face below Class II Class III = italic face below Class IIP 9 1.61 928 1.82 91 2.03 11 2.83 1124 3.1 1280 4.33 400 134 6000 104 6600 18 200 204 63.2 0.1 8.9 849 1.23 40.93 801 1.1 863 1.4 92 1.8 833 1.36 886 1.63 943 1.9 02 2.32 916 1.82 96 2.13 19 2.48 2 2.88 991 2.31 39 2.6 88 3.04 1140 3.48 1146 3.4 1169 3.9 1213 4.24 1260 4.4 1293 4.8 131.18 133.60 1368 6.09 800 221 8400 2386 9000 26 9600 22 920 1. 990 1.96 61 2.41 1132 2.93 993 2.1 9 2.9 1126 3.08 1193 3.64 62 2.4 1123 3.23 118 3. 1248 4.3 112 3.34 1186 3.86 1246 4.4 1306.09 1192 3.9 1246 4.2 1301.14 1360.83 1309.29 1360.92 1411 6.61 1464.36 1414 6.2 1462.40 111 8.14 161 8.9 200 289 800 3068 11400 3238 12000 3409 1203 3.1 123 4.1 1344 4.90 141.2 1260 4.2 1328 4.9 1396.4 1464 6.60 1313.04 139.8 144 6.60 111.0 136.81 1429 6.61 1491.48 1 8.43 1419 6.9 149.42 140 8.33 1601 9.33 118 8.18 12 9.08 1630.0 1689 11.1 1613 9.8 166.84 119 11.90 12 13.03 12600 39 13200 30 13800 3920 14400 4090 148 6.62 16.61 162 8.0 1698 9.88 133. 1602 8.8 160 9.1 139.94 18 8.49 164 9. 112.4 19 12.01 1620 9.46 1686. 12 11.9 1818 13. 1663.41 12 11.9 190 12.8 18 14.20 149 12.31 1809 13. 1869 14.92 1931 16.38 1828 14.26 1886 1.9 194 1.02 2004 18.6 00 4261 1600 4431 16200 4602 16800 42 168 11.1 1839 12.6 19 14.0 1981 1.69 1809 12.2 188 13.1 194 1.26 201 16.92 184 13.39 191 14.8 1983 16.46 202 18.1 1884 14.2 191 16.04 2018 1.6 208 19.42 1920 1.66 1986 1.23 202 18.90 2118 20.0 1992 1.94 204 19.61 2116 21.40 2181 23.28 2064 20.20 212 21.9 2186 23.82 224 2.80 1400 4943 201 1.43 2086 18.1 2120 19.99 213 21.30 218 22.61 2246 2.2 2308 2.91 400 134 6000 104 6600 18 200 204 1432 6.08 144 6.64 1466.1 1488.6 18.42 11 8.08 184 8.6 1604 9.3 1686 9. 1699.34 112 11.14 Minimum motor frame size is 143T regardless of BHP. 180 11.96 1820 12.8 1908 13.62 1921 14.60 2016 16.39 800 221 8400 2386 9000 26 9600 22 111 8.21 16 8.96 1604 9. 162.66 162 9.99 160.63 1689 11.46 136 12.41 134 11.84 16 12.6 19 13.30 181 14.22 1834 13. 186 14.4 189 1.3 1901 16.22 1933 1.61 1949 16.9 192 1.49 199 18.42 2029 1.0 2042 18.63 2060 19.6 2083 20.68 2120 19.41 2133 20.64 2146 21.89 216 22.99 200 289 800 3068 11400 3238 12000 3409 101 11.60 11 12.66 1803 13.9 186 1.00 184 13.44 1832 14.3 1882 1.2 1933 1.01 1862 1.32 1909 16.49 198 1.4 2006 19.0 193 1.2 1982 18.0 2030 19.82 208 21.22 201 19.39 201 20.4 2098 21.94 214 23.41 2 21.2 2128 22.80 2164 24. 22 2.6 2189 24. 2212 2.26 223 26.4 223 2.92 12600 39 13200 30 13800 3920 14400 4090 1909 16.30 1962 1.68 2016 19.1 204 20.8 198 18.38 203 19.8 2090 21.42 2144 23.08 20 20.1 29 22.06 2161 23.0 2213 2.44 2126 22.1 216 24.30 222 26.02 229 2.84 2193 24.9 2242 26.62 2291 28.3 2342 30.2 228 2.28 2306 29.01 234 30.83 2403 32.4 2319 29.63 236 31.43 2414 33.32 2463 3.31 00 4261 1600 4431 16200 4602 16800 42 2132 22.0 2192 24.33 221 26.2 2311 28.33 2198 24.84 22 26.3 2313 28.6 232 30.90 2266 2.28 2320 29.23 234 31.29 2431 33.0 2331 29.6 2384 31.9 243 33.93 2491 36.19 2394 32.2 2446 34.38 2498 36.60 21 38.93 244 34.81 20 3.00 2 39.30 212 3.40 262 39.6 1400 4943 231 30.2 2431 33.1 2489 3.84 246 38.6 18 800 221 8400 2386 9000 26 9600 22 200 289 800 3068 11400 3238 12000 3409 12600 39 13200 30 13800 3920 14400 4090 00 4261 12" SP 13" SP 14" SP 1" SP 16" SP 220 21.36 2220 22.68 2232 24.02 224 2.3 220 26.4 2292 2. 231 29.03 2338 30.34 239 32.02 2426 33.89 243 3.86 221 3.92 269 40.09 2303 24. 2316 26.19 2329 2.66 234 29.03 2369 30.33 2392 31.6 241 33.0 2438 34.4 2483 36.39 229 38.43 2 40.6 2383 26.8 2396 28.39 2409 29.9 2422 31. 2443 32.94 2466 34.3 2489 3.81 211 3.31 238 38.92 284 41.03 243 30.61 2486 32.2 2499 33.9 21 3.9 23 3.08 260 38.61 283 40.19 248 32.86 261 34.62 24 36.41 Power rating (BHP) does not include drive losses. Performance shown is for installation type B-Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. *Inlet O.D. if optional inlet collar is ordered. Maximum Motor Frame Size = 284T (Class II) Maximum Motor Frame Size = 324T (Class IIP) Maximum Motor Frame Size = 326T (Class III) Check direct drive tables on page. Arrangement 4 would be more compact, less expensive and require less maintenance.